• 제목/요약/키워드: Measurement of Effectiveness

검색결과 1,303건 처리시간 0.032초

시맨틱 검색 시스템의 구현과 평가에 관한 연구 (A Study on the Implementation and Evaluation of a Semantic Search System)

  • 한동일;권혁인;최호준
    • 한국IT서비스학회지
    • /
    • 제7권3호
    • /
    • pp.253-269
    • /
    • 2008
  • In this paper, we present an application called Semantic Search which is built on different supporting technologies and is designed to improve traditional web searching. The Semantic Search is becoming crucial challenges on semantic web. The assessment and the implementation of the research on Semantic Search is not full-fledged whereas its research is highly interested. Also there exists only little research that offers a commercial use Semantic Search System that should be taken into the account in measuring the effectiveness of a Semantic Search System. This paper proposes an implementation and evaluation for the Semantic Search System. Firstly, we built Semantic Search System which includes a case of development and it's procedure. Secondly, We presented the measurement of our Semantic Search System's effectiveness. Finally, the evaluation offers useful implications to the researchers and practitioners to improve the research level to the commercial use.

Evaluation of strength characteristics of cement-stabilized soil using the electrical resistivity measurement

  • Kean Thai Chhun;Chan-Young Yune
    • Geomechanics and Engineering
    • /
    • 제33권3호
    • /
    • pp.261-269
    • /
    • 2023
  • In this study, the compressive strength of cement stabilized soil was predicted using the electrical resistivity measurement. The effects of the water to cement (w/c) ratio and recovered Carbon Black (rCB) contents were examined. A series of electrical resistivity and compressive strength tests were conducted on two types of stabilized soil after 28 days of curing. Multiple nonlinear regression (MNLR) analysis was used to evaluate the relationship between the compressive strength and the electrical resistivity in terms of the rCB, Cu (uniformity coefficient), and w/c ratio. The results showed that the w/c ratio and Cu have a strong influence on the compressive strength and electrical resistivity of the cement stabilized soil compared to the rCB content. The use of a small amount of rCB led to a decrease in the void space in the specimen and was attributed to the increase strength and decrease electrical resistivity. A high w/c ratio also induced a low electrical resistivity and compressive strength, whereas 3% rCB in the cemented soil provided the optimum strength for all w/c ratios. Finally, a prediction equation for the compressive strength using the electrical resistivity measurement was suggested based on its reliability, time effectiveness, non-destructiveness, and cost-effectiveness.

공급사슬관리 관점에서의 전략적 항만성과측정 (The Strategic Performance Measurement of Sea Port: Supply Chain Management Perspectives)

  • 박명섭
    • 무역상무연구
    • /
    • 제38권
    • /
    • pp.229-262
    • /
    • 2008
  • With the introduction of supply chain management concept, the nature of a firm is fundamentally changed. Control is no longer based on direct control of the business processes, but rather based on integration across member organizations in the supply chain. Firms are trying to achieve a competitive edge by managing their supply chain performance to gain advantages in cost and service differentiation. The supply chain elements of a sea port involves ILSP (Inbound Logistics Service Provider) at the input side and OLSP (Outbound Logistics Service Provider) at the output side. The goal of sea port is to satisfy the needs of different parties, both upstream and downstream, in the chain with greater effectiveness and efficiency than it's competitors. In this context, the purpose of this paper is to derive conceptualization of the SCP (Supply Chain Performance) in the sea port from literature review on the previous researches and to tackle their theoretical and practical implications. The paper deals with conceptualizing SCP in sea port using the SCOR (Supply Chain Operation Reference) model. It incorporates both the effectiveness and efficiency aspects of performance measurement. And it also recognizes customer related reasons for measuring performance.

  • PDF

진동 파워흐름 측정을 통한 SUV용 엔진 마운트의 에너지 전달 기여도 분석에 관한 연구 (A Study on the Transmitted Energy Contribution Analysis of SUV Engine Mount by Vibration Power Flow Measurement)

  • 김수곤;이상권;김성종
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.400-410
    • /
    • 2008
  • Reduction of structure-borne noise in the compartment of a car is an important task in automotive engineering. Many methods which analyze noise transfer path have been generally used for structure-borne noise. These methods are useful in solving particular problem but do not quantify the effectiveness of vibration isolation for each isolator of a vehicle. To quantify the effectiveness of vibration isolation, the vibrational power flow measurement has been used for a simple isolation system or a laboratory based isolation system. This paper identifies the transfer path of booming noise in a SUV. The powertrain used for test has a in-line 4cylinder engine and 5-shift auto-transmission. This powertrain is transversely supported by four isolators. We calculated the energy flow throughout four isolator by the measurement of power flow and the contribution of energy flow at each isolator.

압력감응페인트를 이용한 확대/축소 유로에서의 막냉각 효율 측정 (Measurement of the Film Cooling Effectiveness using Pressure Sensitive Paint on Convergent/Divergent Channel)

  • 박승덕;이기선;김성하;김학봉;곽재수;김춘택;양계병
    • 한국유체기계학회 논문집
    • /
    • 제11권6호
    • /
    • pp.31-37
    • /
    • 2008
  • Film cooling effectiveness on the convergent or divergent channel was measured by pressure sensitive paint technique. The channel convergent or divergent angle was changed from $-5^{\circ}$ to $10^{\circ}$ and the tested blowing ratios were 0.5, 1 and 2. Results showed that the film cooling effectiveness on the convergent channel was not much affected by the convergent angle. With divergent film cooled surface, the film cooling effectiveness near the injection hole decreased as the divergent angle increases. However, the film cooling effectiveness at far downstream from the hole showed opposite trend. For the non-film cooled surface inclined case, the film cooling effectiveness was not much affected by the divergent angle.

사각홀에서 막냉각 효율 및 열전달계수의 측정 (Measurement of Film Cooling Effectiveness and Heat Transfer of Rectangular-Shaped Film Cooling Holes)

  • 이윤석;이동호
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.365-376
    • /
    • 2002
  • An experimental study has been conducted to measure the local film-cooling effectiveness and the heat transfer coefficient for a single row of rectangular-shaped holes. four different cooling hole shapes such ai a straight rectangular hole, a rectangular hole with laterally expanded exit, a circular hole and a two-dimensional slot are tested. A technique using thermochromic liquid crystals determine adiabatic film cooling effectiveness values and heat transfer coefficients on the test surface. Both film cooling effectiveness and heat transfer coefficient are measured for various blowing rates and compared with the results of the cylindrical ho1es and the two-dimensional slot. The flow patterns downstream of holes are calculated numerically using a cummercial package. The results show that the rectangular hopes provide better peformance than the cylindrical holes. For the rectangular holes with expanded exit, the penetration is reduced significantly, and the higher and more uniform cooling Peformance is obtained even at relatively high blowing rates.

Design of a Stress Measurement System for State Recognition of Game Addicts

  • Park, Myeong-Chul;Jung, Hyon-Chel;Kim, Tae-Sun
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권6호
    • /
    • pp.87-93
    • /
    • 2017
  • In this paper, we design a small low power single channel ECG(Electrocardiogram) system of Chest Belt type with fiber-type electrodes to measure emotional state change of game addict. HRV(Heart Rate Variability) is analyzed through heart rate signal measurement and the psychological stress state is judged by using it. And it verifies its effectiveness through prototype. First, we design HR measurement module through low power MCU(Micro Controller Unit) and implement prototype level measurement system. The results showed that the difference between the addiction group and the general group was confirmed and that the system was effective. The result of this study can be used for health management such as reduction of stress of the user through music and breathing that lowers the stress by detecting the stress state of the general person or the chronic ill person.

Compensation of errors caused by resonance vibration of measurement system in impact force measurement

  • Usui, Y.;Miyazawa, S.;Sawai, N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.593-596
    • /
    • 1994
  • When a force impulse acting on a massive and plex object is measured with a dynamometer, be resonant vibration of the measurement system often leads to serious inaccuracies. A more accurate measurement is obtained when the transfer function ,of the object-dynamometer system is used to compensate for the error in the dynamometer's output signal. The natural frequency and the damping coefficient of the transfer function are estimated by analyzing the waveform of the free damped vibration period after the loading of the force has ended. The residue of the system is determined such that the compensated force spectrum becomes smooth within a neighborhood of the natural frequency. The effectiveness of this signal processing method is experimentally tested on a hammer impulse, under the assumption that the hammer's high resonant frequency accurately models the problems encountered in force impact measurement. The compensation method is used to derive a improved estimate of the hammer impulse.

  • PDF

Analysis, Modeling and Compensation of Dynamic Imbalance Error for a Magnetically Suspended Sensitive Gyroscope

  • Xin, Chaojun;Cai, Yuanwen;Ren, Yuan;Fan, Yahong;Xu, Guofeng;Lei, Xu
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.529-536
    • /
    • 2016
  • Magnetically suspended sensitive gyroscopes (MSSGs) provide an interesting alternative for achieving precious attitude angular measurement. To effectively reduce the measurement error caused by dynamic imbalance, this paper proposes a novel compensation method based on analysis and modeling of the error for a MSSG. Firstly, the angular velocity measurement principle of the MSSG is described. Then the analytical model of dynamic imbalance error has been established by solving the complex coefficient differential dynamic equations of the rotor. The generation mechanism and changing regularity of the dynamic imbalance error have been revealed. Next, a compensation method is designed to compensate the dynamic imbalance error and improve the measurement accuracy of the MSSG. The common issues caused by dynamic imbalance can be effectively resolved by the proposed method in gyroscopes with a levitating rotor. Comparative simulation results before and after compensation have verified the effectiveness and superiority of the proposed compensation method.

Liquid level measurement system using capacitive sensor and optical sensor

  • Shim, Joonhwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권7호
    • /
    • pp.778-783
    • /
    • 2013
  • Measurement of liquid level in storage and processing vessels, tanks, wells, reservoirs and hoppers is commonly needed. The several different ways to measure the liquid level of oil or water tank have been provided such as an electrostatic capacity, a supersonic waves and an optical science etc. In the study, we have constructed the stable and efficient measurement system to measure the level of liquid at real-time and to get accurate measurement of the maximum and minimum level of the tank. For this purpose, we suggest double sensing methods by adopting both capacitive and optical sensing. The experimental results, presented in this paper, illustrate the effectiveness of the proposed method under different sensing methods.