• Title/Summary/Keyword: Measurement methods

Search Result 8,176, Processing Time 0.037 seconds

Finite Element Analysis of BLDC Motor Characteristic according to Magnetic Property Measurement Methods (자성 측정 방법에 따른 BLDC 전동기의 전자계 특성해석)

  • Kim, Ji-Hyun;Ha, Kyung-Ho;Kwon, Oh-Yeoul;Cha, Sang-Yoon;Kim, Jae-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.697-698
    • /
    • 2008
  • This paper deals with finite element characteristic analysis of brushless DC motor according to magnetic property measurement methods. Magnetic property data for non-oriented (NO) electrical steel for electric motors are measured by the Epstein test which is considered as the international standards. Data from Epstein test may result in discrepancy from motor characteristic tests due to innate anisotropic property of NO electrical steel. Finite element analysis were performed for a BLDC motor by various measurement methods such as Epstein test, Ring test and single sheet test (SST), and calculated results were compared with considering anisotropic property conditions.

  • PDF

Subjective Assessment of Simulated Heavy Floor Impact Sounds for Alternative Rating Method (현행 중량바닥충격음 평가방법 개선을 위한 주관평가실험)

  • Shin, Hoon;Kim, Sun-Woo;Jang, Gil-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.3
    • /
    • pp.282-287
    • /
    • 2009
  • This study aims to examine the existing single rating index in terms of level reduction limit of heavy-weight floor impact sound. To achieve this goal, sounds which have same loudness according to rating methods were suggested to subjects. And followings are results. 1) The rating method of measurement frequency level average is more suitable than that of other methods which are dependent on specific frequency for rating heavy-weight floor impact sound. 2) Level average for measurement frequency of $31.5\;Hz{\sim}500\;Hz$ is more correspondent to psycho-acoustic response than that of measurement frequency of $63\;Hz{\sim}500\;Hz$ which is for KS F 2863-2, existing rating method.

Comparative study on the specimen thickness measurement using EELS and CBED methods

  • Yoon-Uk Heo
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.8.1-8.7
    • /
    • 2020
  • Two thickness measurement methods using an electron energy loss spectroscopy (EELS) and 10a convergent beam electron diffraction (CBED) were compared in an Fe-18Mn-0.7C alloy. The thin foil specimen was firstly tilted to satisfy 10a two-beam condition. Low loss spectra of EELS and CBED patterns were acquired in scanning transmission electron microscopy (STEM) and TEM-CBED modes under the two-beam condition. The log-ratio method was used for measuring the thin foil thickness. Kossel-Möllenstedt (K-M) fringe of the $13{\ba{1}}$ diffracted disk of austenite was analyzed to evaluate the thickness. The results prove the good coherency between both methods in the thickness range of 72 ~ 113 nm with a difference of less than 5%.

A Survey for Performance Measurement Indicators of Nursing Organizations in Hospitals (병원 간호조직의 성과평가지표에 관한 조사 연구)

  • Lee, Hae-Jong;Kang, Kyeong-Hwa;Jang, Soo-Jung;Kim, In-Sook
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.11 no.4
    • /
    • pp.385-399
    • /
    • 2005
  • Objective: The objective was to extract a preliminary performance measurement indicators of nursing organizations in hospitals using the BSC(Balanced Score Card) developed by Kaplan and Norton, and to analyze the content validity and evaluation methods of the performance measurement indicators with actual nurses in the nursing organization as participants in the study. Methods: The preliminary performance measurement indicators was created through a literature review and had the content validity by a professional. This survey was sent via post to 316 nurse managers and nurses with more than 5 years of experience in seven secondary and tertiary hospitals in the Seoul Gyonggi district. The completed questionnaires were returned by mail. Results: Fourteen indicators for finances, 16 for customer services, 27 for internal business processes, and 13 for learning and growth were selected. Conclusion: Amidst a rapidly changing medical environment, a first step was taken towards developing a performance measurement from various perspectives for nursing organizations in hospitals from various perspectives, rather than just one or a past-oriented perspective. However, as the most important thing is to actually use these indicators, continuous interest in publicity and education must be developed.

  • PDF

On the measurement of characteristics of antennas for indoor digital TV (실내 디지털 TV용 안테나 특성 측정에 관하여)

  • Park, Jin-Taek;Lee, Jong-Ig;Yeo, Junho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2345-2350
    • /
    • 2014
  • In this paper, measurement methods for the characteristics of antennas for indoor digital TV (DTV), having 75-ohm port impedance, are introduced. Reference impedance of typical radio frequency (or microwave) systems and measurement equipments is 50 ohm. However, the reference impedance of antennas for indoor DTV is 75 ohm, and the characteristics of the antennas cannot be measured directly using the measurement equipments. Measurement methods, using test equipments with reference impedance of 50 ohm, for the characteristics(impedance, radiation patterns, and gain) of antennas designed to fit for 75 ohm port are introduced.

On the measurement of characteristics of planar antennas for indoor digital TV (실내 디지털 TV용 평면 안테나 특성 측정에 관하여)

  • Lee, Jong-Ig;Yeo, Junho;Kim, Soo-Min;Yang, Myung-Kyu;Eun, Jang-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.45-46
    • /
    • 2014
  • In this paper, measurement methods for the characteristics of antennas for indoor digital TV (DTV), having 75-ohm port impedance, are introduced. Reference impedance of typical radio frequency (or microwave) systems and measurement equipments is 50 ohm. However, the reference impedance of antennas for indoor DTV is 75 ohm, and the characteristics of the antennas cannot be measured directly using the measurement equipments. Measurement methods, using test equipments with reference impedance of 50 ohm, for the characteristics(impedance, radiation patterns, and gains) of antennas designed to fit for 75 ohm port are introduced.

  • PDF

WIRELESS SENSOR NETWORK BASED BRIDGE MANAGEMENT SYSTEM FOR INFRASTRUCTURE ASSET MANAGEMENT

  • Jung-Yeol Kim;Myung-Jin Chae;Giu Lee;Jae-Woo Park;Moon-Young Cho
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1324-1327
    • /
    • 2009
  • Social infrastructure is the basis of public welfare and should be recognized and managed as important assets. Bridge is one of the most important infrastructures to be managed systematically because the impact of the failure is critical. It is essential to monitor the performance of bridges in order to manage them as an asset. But current analytical methods such as predictive modeling and structural analysis are very complicated and difficult to use in practice. To apply these methods, structural and material condition data collection should be performed in each element of bridge. But it is difficult to collect these detailed data in large numbers and various kinds of bridges. Therefore, it is necessary to collect data of major measurement items and predict the life of bridges roughly with advanced information technologies. When certain measurement items reach predefined limits in the monitoring bridges, precise performance measurement will be done by detailed site measurement. This paper describes the selection of major measurement items that can represent the tendency of bridge life and introduces automated bridge data collection test-bed using wireless sensor network technology. The following will be major parts of this paper: 1) Examining the features of conventional bridge management system and data collection method 2) Mileage concept as a bridge life indicator and measuring method of the indicator 3) Test-bed of automated and real-time based bridge life indicator monitoring system using wireless sensor network

  • PDF

The Effectiveness of the Use of Distance-Evaluation Tools and Methods among Students with Learning-Difficulties from the Teachers' Point of View

  • Almaleki, Deyab A.;Khayat, Wejdan W.;Yally, Taghreed F.;Al-hajjaji, Aysha A.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.5
    • /
    • pp.243-255
    • /
    • 2021
  • This study aimed to identify the effectiveness of the use of distance-evaluation tools and methods among students with learning difficulties from the teachers' point of view, to achieve this goal. A scale was built, and the psychometric characteristics were validated. It consisted, in its final form, of 17 items distributed on four axes, in addition to three open questions. It was applied to a random sample of (149) teachers of students with learning difficulties in Makkah Region. The results showed that teachers' keenness to encourage students with learning difficulties, so that they would not feel frustrated with the distance learning process. It was also evident that teachers did not use achievement portfolios in the evaluation process. In connection with the appropriate evaluation methods, the majority indicated the use of work sheets and visual evaluation methods that rely on audio and visual skills, such as presenting videos, pictures, audio and games, and applying short objective tests. Among the proposals to improve evaluation methods and tools: Individual evaluation, attention to individual treatment, obligating personal attendance of students to school, splitting the required tasks, and not increasing the skills required to be mastered. As for the obstacles that teachers face: Lack of time, difficulty in communicating with students with distance learning difficulties and problems related to the Internet such as interruption, weakness, or lack of availability.

Leak Evaluation for Power Plant Valve Using Multi-Measuring Method

  • Lee, Sang-Guk;Park, Jong-Hyuck;Kim, Young-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.469-476
    • /
    • 2008
  • Condition based maintenance(CBM) for the preventive diagnosis of important equipments related to safety or accident in power plant is essential by using the suitable methods based on actual power plant conditions. To improve the reliability and accuracy of the measured value at the minute leak situation, and also to monitor continuously internal leak condition of power plant valve, the development of a diagnosis and monitoring technique using multi-measuring method should be performed urgently. This study was conducted to estimate the feasibility of multi-measuring method using three different methods such as acoustic emission(AE) method, thermal image measurement and temperature difference$({\Delta}T)$ measurement that are applicable to internal leak diagnosis for the power plant valve. From the experimental results, it was suggested that the multi-measuring method could be an effective way to precisely diagnose and evaluate internal leak situation of valve.

Ship Radiated Noise Measurement Methods and Accuracy Analysis (선박 방사소음의 측정방법 및 정확도 해석)

  • Lee, Phil-Ho;Yoon, Jong-Rak
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.738-748
    • /
    • 2005
  • The ship radiated noise level fluctuates by the difference of interference and reverberation according to measurement methods and environmental conditions. These phenomena cause error of the source level estimation even in the same environment conditions. This paper describes a quantitative analysis and a reduction method for an error value to the source level estimation in spatial and temporal interference environment. The design criteria of the radiated noise measurement array composed of omni-directional hydrophones and the source level accuracy in the deep water range are given. The source level accuracy in the shallow water range is also derived based on the statistical model of the multiple reflection paths. The results are verified using the water tank experiment and the sea trial.