• 제목/요약/키워드: Measurement locations

검색결과 575건 처리시간 0.025초

APR1400 원자로내부구조물 종합진동평가 측정위치 선정 기준 (Selection Criteria of Measurement Locations for Advanced Power Reactor 1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program)

  • 고도영;김규형;김성환
    • 한국소음진동공학회논문집
    • /
    • 제21권8호
    • /
    • pp.708-713
    • /
    • 2011
  • U.S. nuclear regulatory commission(NRC) regulatory guide(RG) 1.20 requires a comprehensive vibration assessment program(CVAP) for use in verifying the structural integrity of reactor vessel internals(RVI) for flow-induced vibrations prior to commercial operation. The CVAP program consist of vibration and fatigue analysis, a vibration measurement program, an inspection program, and a correlation of their results. One of the main purposes of the analysis program is to select measurement locations, however measurement locations can not be determined by only analysis results, therefore we developed selection criteria of measurement locations for advanced power reactor 1400(APR1400) RVI CVAP, It will be used to select measurement locations and instrument types for APR1400 RVI CVAP.

다수 측정 위치를 갖는 단일 공정의 공정능력지수 (Process capability index for single process with multiple measurement locations)

  • 이도경;이현석
    • 산업경영시스템학회지
    • /
    • 제30권3호
    • /
    • pp.28-36
    • /
    • 2007
  • Process Capability indices (PCIs) have been widely used in manufacturing industries to provide a quantitative measure of process performance. PCIs have been developed to represent process capability more exactly. In the previous studies, only one designated location on each part is measured. But even though in single process, multiple measurement locations on each part are required to calculate the reliable process capability. In this paper, we propose a new process capability index with multiple measurement locations on each part. We showed numerical examples and sensitivity analysis according to the number of measurement locations.

공정능력과 시그마 수준의 표시에 대한 연구 : 다수 위치측정에 대한 공정능력지수 기준 (A Study on Expression of Process Capability and Sigma Level)

  • 이도경
    • 산업경영시스템학회지
    • /
    • 제32권1호
    • /
    • pp.111-116
    • /
    • 2009
  • Process capability indices have been widely used in manufacturing industries to provide a quantitative measure of process performance. PCIs have been developed to represent process capability more exactly. In the previous studies, only one designated location on each part has been measured. But multiple measurement locations on each part are required to calculate the reliable process capability. In this paper, we propose a new process capability index dealing the multiple measurement locations on each part. Also we showed the relationship between the new index and sigma level according to the number of measurement locations.

하천 및 호소수 수질관리를 위한 자동측정망의 설계 (Design of Automatic Monitoring Network for the Water Quality Management of River Basin)

  • 최지용;박원규;이상일
    • 물과 미래
    • /
    • 제29권2호
    • /
    • pp.167-178
    • /
    • 1996
  • 하천 및 호소수 수질의 온라인 계측을 위한 수질자동측정망의 설계에서 측정위치와 항목의 선정은 전체시스템의 성능을 결정짓는 중요한 인자이다. 본 논문에서는 상수원유역의 상시수질감시 및 사전경보 기능을 갖는 측정망의 구축이 측정위치와 항목을 결정하는 방법을 연구하였다. 측정위치를 결정하기 위한 선정기준은 상수취수량과 고정오염원의 위치를 바탕으로 대상지역에 대한 거시적 후보지점을 선정한 뒤, 구체적인 지점은 오염물질 유하거리를 기준으로 단계적으로 결정한다. 측정항목은 유역의 오염특성과 수질오염사고 이력을 참고하되, 경제적인 측면을 고려하여 필수측정항목과 선택항목으로 나누어 위치별로 달리하는 방안을 제시하였다. 제안방법을 낙동강유역에 적용함으로써 측정망 구성과정을 예시하였다.

  • PDF

Beacon-Based Indoor Location Measurement Method to Enhanced Common Chord-Based Trilateration

  • Kwak, Jeonghoon;Sung, Yunsick
    • Journal of Information Processing Systems
    • /
    • 제13권6호
    • /
    • pp.1640-1651
    • /
    • 2017
  • To make an unmanned aerial vehicle (UAVs) fly in indoor environments, the indoor locations of the UAV are required. One of the approaches to calculate the locations of an UAV in indoor environments is enhanced trilateration using one Bluetooth-based beacon and three or more access points (APs). However, the locations of the UAV calculated by the common chord-based trilateration has errors due to the distance errors of the beacon measured at the multiple APs. This paper proposes a method that corrects the errors that occur in the process of applying the common chord-based trilateration to calculate the locations of an UAV. In the experiments, the results of measuring the locations using the proposed method in an indoor environment was compared and verified against the result of measuring the locations using the common chord-based trilateration. The proposed method improved the accuracy of location measurement by 81.2% compared to the common chord-based trilateration.

실측자료에 근거한 동해안 파력 부존량 검토 (Investigation on the Wave Power Resources on the East Coast of Korea Based on Field Measurement Data)

  • 정원무;오상호;이달수;이동영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.630-634
    • /
    • 2007
  • In the past, the use of wave energy has mainly been focused on conversion of large wave energy resources in the far offshore areas. However, with the technological improvement of converting wave energy into electricity, the energy resources at much shallow waters are now considered as a site for possible installation of the devices that obtain energy from the waves. In this respect, the wave energy resources on the east coast of Korea, where the sea is milder than the open ocean, were investigated using the field measurement data obtained at three different locations along the coast. For all the locations, the wave power was greater in winter season, compared to summer season. The estimated wave power varied from 2 to 4.5 kW/m on average, depending on the measurement locations.

  • PDF

APR1400 상부안내구조물 집합체 구조해석 및 측정위치 (Structural Analysis and Measuring Locations of Upper Guide Structure Assembly in APR1400)

  • 고도영;김규형;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.306-311
    • /
    • 2012
  • A reactor vessel internals comprehensive vibration assessment program (RVI CVAP) of an advanced power reactor 1400 (APR1400) is being performed as a non-prototype category-2 type of reactor based on the US Nuclear Regulatory Commission Regulatory Guide (NRC RG) 1.20. The aim of this paper is to present the results of structural response analysis and measuring locations of a upper guide structure (UGS) assembly of the APR1400 reactor. The analysis results of the UGS assembly results show that meet the specified integrity levels of the design acceptance criteria. Also, the measuring locations are set by the analysis results of the UGS assembly and selection criteria of measuring locations prior to this study. These analysis results and measuring locations will be used as fundamental materials to design a measurement system for the APR1400 RVI CVAP.

  • PDF

시각측정시스템의 캘리브레이션 및 측정성능 검토 (Calibration and INvestigation into Measurement Performance of a Visual Sensing System)

  • 김진영;조형석
    • 한국정밀공학회지
    • /
    • 제16권8호
    • /
    • pp.113-121
    • /
    • 1999
  • It is necessary to calibrate measurement systems to enhance its measurement accuracy. The visual sensing system that is presented in our previous work has to be calibrated, too. It is a multiple mirror system for three-dimensional measurement, which is composed of a camera and a series of mirrors. It is important to calibrate the positions and orientations of the mirrors relative to the camera because they have direct influence on the relationship between the image plane and the task space. This paper presents the calibration method for the visual sensing system. To confirm the measurement performance of the implemented system. its measurement accuracy in measuring the locations in three-dimensional space is investigated. A series of experiments for measuring the locations of the circle-shaped marks are performed. Experimental results show that the sensing system can be effectively used for three-dimensional measurement.

  • PDF

원자로 내부배럴집합체 상부면 측정위치 선정 (Selection of Measurement Locations at Inner Barrel Assembly Top Plate in the Reactor)

  • 고도영;김규형;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.734-738
    • /
    • 2012
  • A comprehensive vibration assessment program for the Advanced Power Reactor 1400 reactor vessel internals is established in accordance with the United States Nuclear Regulatory Commission Regulatory Guide 1.20 Revision 3. This paper is related to instruments and measurement locations based on the vibration and stress response analysis results at the inner barrel assembly top plate in the reactor. The analysis results of the inner barrel assembly top plate in the reactor show that the deterministic stress and deformation due to the reactor coolant pump induced pressure pulsations are larger than the random stress and deformation induced by the flow turbulence. The selection of the instruments and measurement locations at Inner barrel assembly top plate in the reactor is essential requirements and very important study process for the vibration and stress measurement program in comprehensive vibration assessment program for the Advanced Power Reactor 1400 reactor vessel internals.

  • PDF

APR1400 내부배럴집합체 상부판 구조해석 및 측정위치 (Structural Analysis and Response Measurement Locations of Inner Barrel Assembly Top Plate in APR1400)

  • 고도영;김규형;김성환
    • 한국소음진동공학회논문집
    • /
    • 제22권5호
    • /
    • pp.474-479
    • /
    • 2012
  • A comprehensive vibration assessment program for the advanced power reactor 1400(APR1400) reactor vessel internals is established in accordance with the united states nuclear regulatory commission regulatory guide 1.20 revision 3. This paper is related to instruments and measurement locations based on the vibration and stress response analysis results of the inner barrel assembly top plate in APR1400. The analysis results of the inner barrel assembly top plate in the reactor show that the deterministic stress and deformation due to the reactor coolant pump induced pressure pulsations are larger than the random stress and deformation induced by the flow turbulence. The selection of the instruments and measurement locations at inner barrel assembly top plate in the reactor is essential requirements and very important study process for the vibration and stress measurement program in comprehensive vibration assessment program for APR1400 reactor vessel internals.