• Title/Summary/Keyword: Measurement element

Search Result 1,351, Processing Time 0.033 seconds

Investigation of Strain Measurements using Digital Image Correlation with a Finite Element Method

  • Zhao, Jian;Zhao, Dong
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.399-404
    • /
    • 2013
  • This article proposes a digital image correlation (DIC) strain measurement method based on a finite element (FE) algorithm. A two-step digital image correlation is presented. In the first step, the gradient-based subpixels technique is used to search the displacements of a region of interest of the specimen, and then the strain fields are obtained by utilizing the finite element method in the second step. Both simulation and experiment processing, including tensile strain deformation, show that the proposed method can achieve nearly the same accuracy as the cubic spline interpolation method in most cases and higher accuracy in some cases, such as the simulations of uniaxial tension with and without noise. The results show that it also has a good noise-robustness. Finally, this method is used in the uniaxial tensile testing for Dahurian Larch wood specimens with or without a hole, and the obtained strain values are close to the results which were obtained from the strain gauge and the cubic spline interpolation method.

Electrical Life Time Constant Estimation of Ceramic Element for Sensor (센서용 세라믹 소체의 전기적 수명지수 산출)

  • Jeong, Joo-Young;Kang, Dong-Sik;Sun, Jong-Ho;Heo, Jong-Cheol;Choo, Young-Bae;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1995-1999
    • /
    • 2009
  • A partial discharge(PD) measurement is a very effective method to assess the insulation condition of high-voltage machines. It is necessary that the life time of the on-line PD measurement sensor is assessed. Therefore, the electrical life time assessment method of ceramic element was reviewed in order to estimate the life time of the on-line PD measurement sensor. The samples were prepared according to the reviewed method and were tested at 8kV, 9kV and 10kV. Based on the obtained results, the life time constant is shown above 59. Also, it is assumed that the estimated life time constant can be used to anticipate the life time and to assess the conformity of the on-line PD measurement sensor.

A Dual-Servo Type VCM for a Nano-Level Measurement System

  • Yoo, Yong-Min;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.50-54
    • /
    • 2007
  • In this paper, a dual-servo type VCM (Voice Coil Motor) for the measuring of nano-level displacement and small thrust is proposed and developed. The shape of VCM for improving the resolution of displacement and ensuring a large displacement are presented. The FEM (finite element method) is utilized to analyze the characteristics of VCM that produces linear driving thrust and satisfies the thrust that the measurement system requires. The Prototype is fabricated and an experiment is performed in order to measure displacement. As a result of simulation and testing, the proposed VCM shows the applicable possibility for a nano-level measurement system.

The Development of Instantaneous Heat Flux Measurement Probe and Calculation of Thermal Stress of Piston by Finite Element Method (순간 열플럭스 측정용 프루브 개발 및 유한요소법에 의한 피스톤 열응력 계산)

  • Lee, J.S.;Woo, J.H.;Lee, E.L.;Jung, I.G.;Lee, H.K.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.267-275
    • /
    • 1998
  • In this study, the instantaneous heat flux measurement probe and the linkage system for the measurement of the instantaneous temperature and heat flux of the DI mono cylinder diesel engine were developed, and these were proved to have a good reliability and sensibility. A 3-D FEM model which consist of full piston to accommodate the eccentric bowl in the piston head, was applied for the analysis of the thermal stress and the temperature distribution. The mean heat flux on the piston head was used as boundary condition for the analysis of piston. The analysis showed that thermal stress concentrate on the bowl and inner surface of pin hall.

  • PDF

Torque Measurement System of Piezoelectric Ultrasonic Motor (압전 초음파 전동기의 토크측정 시스템)

  • Kim, Young-Gyoon;Kim, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1780-1782
    • /
    • 1999
  • The ultrasonic motor used here is the windmill type ultrasonic motor operated by single-phase AC source. A metal-ceramic composite component was used as the stator element to generate ultrasonic vibrations. The windmill type ultrasonic motors has only three components; a stator element of two wind-mill shape slotted metal endcaps, a rotor and a bearing. In this paper we proposed a system for torque measurement of piezoelectric ultrasonic motor.

  • PDF

제너 다이오드를 이용한 공기 유속계측 장치개발

  • 김영재;김희식;조흥근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.496-500
    • /
    • 1996
  • An air flow measurement device is proposed. The thermal characteristic of a semiconductor element is adopted as a cooling parameter of thermal convection rate. The difference between forced convection and natural convection of two Zener diodes results enough difference in temperature. Experiment at various air flow conditions shows the measuring capability of the air flow in a duct. This measuring device has some merits, such as a reliability n hard field condition, simple circuit for signal processing, small volume of the element, less air flow resistance, independance of various ai temperature. The experimental result shows that it is an exact and usefull air flow measurement device.

  • PDF

Proposal of residual stress mitigation in nuclear safety-related austenitic stainless steel TP304 pipe bended by local induction heating process via elastic-plastic finite element analysis

  • Kim, Jong-Sung;Kim, Kyoung-Soo;Oh, Young-Jin;Oh, Chang-Young
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1451-1469
    • /
    • 2019
  • This paper proposes a residual stress mitigation of a nuclear safety-related austenitic stainless steel TP304 pipe bended by local induction heating process via performing elastic-plastic finite element analysis. Residual stress distributions of the pipe bend were calculated by performing finite element analysis. Validity of the finite element analysis procedure was verified via comparing with temperature histories measured by using thermocouples, ultrasonic thickness measurement results, and residual stress measurement results by a hole-drilling method. Parametric finite element stress analysis was performed to investigate effects of the process and geometric shape variables on the residual stresses on inner surfaces of the pipe by applying the verified procedure. As a result of the parametric analysis, it was found that it is difficult to considerably reduce the inner surface residual stresses by changing the existing process and geometric shape variables. So, in order to mitigate the residual stresses, effect of an additional process such as cooling after the bending on the residual stresses was investigated. Finally, it was identified that the additional heating after the bending can significantly reduce the residual stresses while other variables have insignificant effect.

Numerical simulation of compressive to tensile load conversion for determining the tensile strength of ultra-high performance concrete

  • Haeri, Hadi;Mirshekari, Nader;Sarfarazi, Vahab;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.605-617
    • /
    • 2020
  • In this study, the experimental tests for the direct tensile strength measurement of Ultra-High Performance Concrete (UHPC) were numerically modeled by using the discrete element method (circle type element) and Finite Element Method (FEM). The experimental tests used for the laboratory tensile strength measurement is the Compressive-to-Tensile Load Conversion (CTLC) device. In this paper, the failure process including the cracks initiation, propagation and coalescence studied and then the direct tensile strength of the UHPC specimens measured by the novel apparatus i.e., CTLC device. For this purpose, the UHPC member (each containing a central hole) prepared, and situated in the CTLC device which in turn placed in the universal testing machine. The direct tensile strength of the member is measured due to the direct tensile stress which is applied to this specimen by the CTLC device. This novel device transferring the applied compressive load to that of the tensile during the testing process. The UHPC beam specimen of size 150 × 60 × 190 mm and internal hole of 75 × 60 mm was used in this study. The rate of the applied compressive load to CTLC device through the universal testing machine was 0.02 MPa/s. The direct tensile strength of UHPC was found using a new formula based on the present analyses. The numerical simulation given in this study gives the tensile strength and failure behavior of the UHPC very close to those obtained experimentally by the CTLC device implemented in the universal testing machine. The percent variation between experimental results and numerical results was found as nearly 2%. PFC2D simulations of the direct tensile strength measuring specimen and ABAQUS simulation of the tested CTLC specimens both demonstrate the validity and capability of the proposed testing procedure for the direct tensile strength measurement of UHPC specimens.

A Study on the measurement of Table Deflection using Laser Interferometer and It's Inspection using FEA (레이저 간섭계에 의한 테이블의 처짐측정과 FEA에 의한 이의 검증)

  • 이승수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.204-209
    • /
    • 1998
  • The acceleration of the performance of machine tools influences the development of the semi-conductor and optical technology as the development of NC and measurement technology. We can mention that a traction role of the acceleration for the development like that depends on the development of the measurement technics Stylus instrument method, STM, SEM, Laser interferometer method which are used for measuring the quasi-static error of machine tools. Because the measurement has been done to unload condition without considering of mechanical stiffness in the case of machining center as we measure the quasi-static error of machine tools on general studies, people who works on the spot has many problems on the data value. Therefor we will help working more accurately on the spot by measuring, analyzing, displaying the deflection of the table and support shaft when we load on the table and the support shaft of machining center using laser interferometer. Also we try to settle new conception of the measurement method and more accurate grasp of the deflection tendency by verifing the tendency of the error measured through the comparison of the simulated error using ANSYS, a common finite element analysis program, which is able to measure heat deformation, material deformation, and error resulted form this study.

  • PDF

A Study of Residual Stress Measurement in the Weld of Nuclear Materials (원전재료 모재 및 용접부 잔류응력측정 연구)

  • Lee, Kyoung-Soo;Lee, Jeong-Keun;Lee, Seong-Ho;Park, Jae-Hak
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.1
    • /
    • pp.9-16
    • /
    • 2011
  • Primary water stress corrosion cracking (PWSCC) has been found in the weld region of the nuclear power plant. Welding can produce tensile residual stress. Tensile residual stress contributes to the initiation and growth of PWSCC. It is important to estimate weld residual stress accurately to predict or prevent the initiation and growth of PWSCC. This paper shows the results of finite element analysis and measurement experiment for weld residual stress. For the study, four kinds of specimen were fabricated with the materials used in the nuclear power plant. Residual stresses were measured by four kinds of methods of hole drilling, x-ray diffraction, instrumented indentation and sectioning. Through the study, numerical analysis and measurement results were compared and the characteristics of each measurement technique were observed.