• 제목/요약/키워드: Measurement development

검색결과 6,824건 처리시간 0.043초

Development of magnetic field measurement system for AMS cyclotron

  • Ho Namgoong;Hyojeong Choi;Mitra Ghergherehchi;Donghyup Ha;Mustafa Mumyapan;Jong-Seo Chai;Jongchul Lee;Hoseung Song
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.3114-3120
    • /
    • 2023
  • A high-accuracy magnetic field measurement device based on a cyclotron is being developed for accelerator mass spectrometry (AMS). In this study, a magnetic field measurement device consisting of a Hall probe sensor, piezo-motor, and step motor was developed to measure the magnetic field of the AMS cyclotron magnet. The Hall probe sensor was calibrated to achieve positional accuracy by using polar coordinates. The measurement results between the ratchet gear and piezo-motor, which are the instruments used for driving the measurement device, were analyzed. The measurement result of the device with a piezo-motor exhibits a difference of 5 Gauss (0.04%) as compared with the simulation result.

광대역 교류 자기센서 특성 시험장치 설계에 관한 연구 (A Study on the System Design for Measuring the Property of Broadband AC Magnetic Sensors)

  • 정현주;양창섭;정우진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.685-686
    • /
    • 2015
  • This paper describes design results of the measurement system to test the properties of broadband AC magnetic field sensors used in weapon system. This measurement system consists of 3-axis helmholtz coil, signal generator, signal amplifier, sensor data acquisition unit and measurement & analysis controller including the operating software. This system is able to measure various properties of AC magnetic field sensor such as sensitivity, linearity and dynamic response in the frequency of 1 Hz to 10 kHz. The performance of this system was verified by measuring and analyzing the property of a MAG 639, standard magnetic field sensor of bartington instruments, with this developed system.

  • PDF

Investigation of an Infrared Temperature Measurement System for Thermal Safety Verification of Plasma Skin Treatment Devices

  • Choi, Jong-ryul;Kim, Wookeun;Kang, Bongkeun;Song, Tae-Ha;Baek, Hee Gyu;Han, Yeong Gil;Park, Jungmoon;Seo, Soowon
    • Current Optics and Photonics
    • /
    • 제1권5호
    • /
    • pp.500-504
    • /
    • 2017
  • In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.

CDGPS의 요동 측정 결과를 이용한 Spotlight SAR 영상 형성에 관한 연구 (A Study on Spotlight SAR Image Formation by using Motion Measurement Results of CDGPS)

  • 황정훈;고영창;김소연;권경일;윤상호;김형석;신현익
    • 한국군사과학기술학회지
    • /
    • 제21권2호
    • /
    • pp.166-172
    • /
    • 2018
  • To develop and evaluate the real-time SAR(Synthetic Aperture Radar) motion measurement system, true antenna phase center(APC) positions during SAT(Synthetic Aperture Time) are needed. In this paper, CDGPS(Carrier phase Differential Global Positioning System) post processing method is proposed to get the true APC position for spotlight SAR image formation. The CDGPS position is smoothed to remove high frequency noise which exists inherently in the carrier phase measurement. This paper shows smoothed CDGPS data is enough to provide the true APC for high-quality SAR image formation through motion measurement result, phase error estimation and IRF(Impulse Response Function) analysis.

소형 무인 로봇의 소음 측정법 개발 및 측정 장소에 따른 상관성 분석 (Noise Measurement Method Development and Correlation Analysis According to Measurement Location of Small Unmanned Robot)

  • 옥진규;박은주;박민수;이명천
    • 한국군사과학기술학회지
    • /
    • 제20권5호
    • /
    • pp.633-638
    • /
    • 2017
  • The small unmanned robot developed in this paper can perform tasks such as surveillance and reconnaissance in the battle field. The noise generated during the operation of the robot may expose the operation area. Therefore, in this study, we developed a method to quantitatively measure the noise of the developed small unmanned ground robot. The criteria for noise measurement in indoor and outdoor are presented. It was used for statistical verification method to verify the reliability of the developed noise measurement method. The noise was measured at different places, and the correlation was analyzed. Thus, we proposed a method to predict the noise level in the operation area where the robot is operated by the noise test data measured during the development process.

Vision-based Automatic System for Non-contact Measurement of Morphometric Characteristics of Flatfish

  • Jeong, Seong-Jae;Yang, Yong-Su;Lee, Kyounghoon;Kang, Jun-Gu;Lee, Dong-Gil
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1194-1201
    • /
    • 2013
  • This paper introduces a vision-based automatic system (VAMS) for non-contact measurement of morphometric characteristics of flatfish, such as total length (TL), body width (BW), height (H), and weight (W). The H and W are simply measured by a laser displacement and a load cell, respectively. The TL and BW are measured by a proposed morphological image processing algorithm. The proposed algorithm cans measurement, when the tail of flatfish is deformed, and when it is randomly oriented. In the experiment, the average and maximum measurement errors were recorded, and standard deviations and coefficients of variation (CVs) for the measurements were calculated. From those results, when flatfish the TL measurements had an average of 266.844 mm, a standard deviation of 0.351 mm, a CV of 0.131%, and a maximum error of 0.87 mm with straightened flatfish ($TL_A$ : 267 mm, $BW_A$ : 141 mm), and when flatfish of different sizes were measured, the errors in the TL and BW measurements were both about 0.2 %. Using a single conveyor, the VAMS can process up to 900 fishes per hour. Moreover, it can measure morphometric characteristics of flatfish with a TL of up to 500 mm.

레이저 간섭계에 의한 테이블의 처짐측정과 FEA에 의한 이의 검증 (A Study on the measurement of Table Deflection using Laser Interferometer and It's Inspection using FEA)

  • 이승수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 추계학술대회 논문집
    • /
    • pp.204-209
    • /
    • 1998
  • The acceleration of the performance of machine tools influences the development of the semi-conductor and optical technology as the development of NC and measurement technology. We can mention that a traction role of the acceleration for the development like that depends on the development of the measurement technics Stylus instrument method, STM, SEM, Laser interferometer method which are used for measuring the quasi-static error of machine tools. Because the measurement has been done to unload condition without considering of mechanical stiffness in the case of machining center as we measure the quasi-static error of machine tools on general studies, people who works on the spot has many problems on the data value. Therefor we will help working more accurately on the spot by measuring, analyzing, displaying the deflection of the table and support shaft when we load on the table and the support shaft of machining center using laser interferometer. Also we try to settle new conception of the measurement method and more accurate grasp of the deflection tendency by verifing the tendency of the error measured through the comparison of the simulated error using ANSYS, a common finite element analysis program, which is able to measure heat deformation, material deformation, and error resulted form this study.

  • PDF

FM 방송 기반 멀티스태틱 PCL 시스템 원형 배열 안테나 보정을 위한 Array Manifold 측정 및 검증 (Array Manifold Measurement and Verification for UCA Calibration in Multistatic PCL System based on FM Broadcasting)

  • 박준식;심홍석;안준일;송규하
    • 한국군사과학기술학회지
    • /
    • 제24권2호
    • /
    • pp.165-174
    • /
    • 2021
  • This study describes a method of measurement and verification of array manifold of uniform circular array antenna applicable to multistatic Passive Coherent Location(PCL) system using FM broadcasting. In an environment of outdoor test where FM broadcast signals are scattered, array manifold measurement methods using network analyzer and multi-channel digital receiver are introduced. Also, the descriptions and solutions for the test limits of each measurement method and the considerations affecting the measurement accuracy are presented. In addition, to verify the validity of the measured array manifold, the gain and phase difference were compared with the array manifold data obtained by EM simulation, and the effectiveness and accuracy of the measured array manifolds were compared and analyzed by estimating the direction of arrival of the FM broadcast signal received from the multistatic PCL system.

일반병동 간호사의 간호역량평가 도구 개발 (A Measurement Scale Development of Nursing Competence for Nurses Working in General Wards)

  • 강윤숙;이숙정;김인자;안금희
    • 간호행정학회지
    • /
    • 제14권3호
    • /
    • pp.219-228
    • /
    • 2008
  • Purpose: The purpose of this study was to develop a measurement scale of nursing competence for nurses working in general wards, and to test the validity and reliability of the scale. Method: A methodological study design was used, consisting of 3 steps as conceptual framework decision, measurement items development, and testing of validity and reliability. In order to verify content validity, 16 experts reviewed the concept of each competences and measurement items. The developed measurement items were tested from 301 nurses in one hospital. Factor analysis and item analysis were applied to establish the scale's construct validity and reliability. Result: The final scale consists of nine dimensions with 70 items. The overall scale reliability had a Cronbach's alpha of 0.98, and the demensions Cronbach's alpha ranged from 0.88 to 0.95. The factor loading of construct validity was from 0.40 to 0.83. The explained variance from the 9 extracted factors was 70.93% of the total variance, and final factors were labeled as critical thinking, resources management and professional development, ability of ward management, application of nursing process, ethical accountability, respectful consideration, patient centered approach, crisis management, and leadership. Conclusion: This measurement scale can be utilized to evaluate nursing competence for nurses working in general wards.

  • PDF

탠덤 비행체의 선구탄두 기폭 충격 측정 시스템 구현 (Explosion Shock Measurement System of the Precursor Warhead for the Tandem Projectile)

  • 최동혁;안지연;김유범;손중탁;이욱준;박현수
    • 한국군사과학기술학회지
    • /
    • 제24권5호
    • /
    • pp.503-510
    • /
    • 2021
  • This paper presents a system that measures the acceleration of the shock caused by the explosion of the precursor warhead for the tandem projectile. The proposed system, which is implemented based on the MIL-STD-810G, Method 517.1, consists of a miniaturized shock measurement device, a cable, accelerometers, and a trigger circuit. The shock measurement device has a size of ¢102 × 171 mm and cable has a length of 3 m. The operational confirmation test is conducted by implementing the measurement system. The Analysis of shock data(accelerometer output data) is carried out using Shock Response Spectrum(SRS), pseudo velocity and plot of acceleration time transient. Through measurement analysis, one can predict the damage of electronics in projectile when precursor warhead is exploded.