• Title/Summary/Keyword: Measurement criteria

Search Result 983, Processing Time 0.033 seconds

Developments of Evaluation System for Qualitative Performance Measurement in Government-Supported Research Institute by Article Citation Method (피인용 특성 분석을 통한 출연(연) 임무중심형 기관평가의 질적 성과평가 개선 방향)

  • Lee, Moon Young;Yi, Chan Goo
    • Journal of Korea Technology Innovation Society
    • /
    • v.19 no.4
    • /
    • pp.768-798
    • /
    • 2016
  • This study started from the awareness of the issue if the citation index newly introduced to evaluate the quality of papers satisfies the proper timing matter, which is a component of performance indicators for the evaluation of government-funded R&D institutes. Accordingly, the study will propose improvement ways to shift the previous evaluation system to quality evaluation for mission-oriented R&D institutes by analysing and using the periodical characteristics such as citation half-life and immediacy index of papers. As a result, it turned out that the speed of academic change is getting faster in proportion to the dependency on the technological development but that the citation speed in the field of public technology is relatively slower and the speed of knowledge transfer in the fields related to industry is faster. In addition, the citation index among the R&D fields showed no differences, and the minimum period for citation index measurement with validity should be over 6 years. The problems of evaluation for mission-oriented R&D institutes were deducted based on the technical and statistical analysis results of the temporal characteristic of citation necessary for quality evaluation of performance among R&D fields. To solve the problems, policy alternatives for object and valid quality evaluation were proposed from the points of evaluation period and evaluation criteria.

Driver's Status Recognition Using Multiple Wearable Sensors (다중 웨어러블 센서를 활용한 운전자 상태 인식)

  • Shin, Euiseob;Kim, Myong-Guk;Lee, Changook;Kang, Hang-Bong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.6
    • /
    • pp.271-280
    • /
    • 2017
  • In this paper, we propose a new safety system composed of wearable devices, driver's seat belt, and integrating controllers. The wearable device and driver's seat belt capture driver's biological information, while the integrating controller analyzes captured signal to alarm the driver or directly control the car appropriately according to the status of the driver. Previous studies regarding driver's safety from driver's seat, steering wheel, or facial camera to capture driver's physiological signal and facial information had difficulties in gathering accurate and continuous signals because the sensors required the upright posture of the driver. Utilizing wearable sensors, however, our proposed system can obtain continuous and highly accurate signals compared to the previous researches. Our advanced wearable apparatus features a sensor that measures the heart rate, skin conductivity, and skin temperature and applies filters to eliminate the noise generated by the automobile. Moreover, the acceleration sensor and the gyro sensor in our wearable device enable the reduction of the measurement errors. Based on the collected bio-signals, the criteria for identifying the driver's condition were presented. The accredited certification body has verified that the devices has the accuracy of the level of medical care. The laboratory test and the real automobile test demonstrate that our proposed system is good for the measurement of the driver's condition.

Measurement of the Compression Force and Thickness applied during Mammography (유방촬영술에서 압력과 두께 측정)

  • Kweon, Dae-Cheol;Lee, Eun-Mi;Park, Peom
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.29-35
    • /
    • 2003
  • The purpose of this study was to compare the compression force and thickness of the compressed breast between mediolateral oblique and craniocaudal mammography. This population consisted of 204 paired mediolateral oblique and craniocaudal mammography obtained on one mammographic unit by certified mammography technologists during 2 month period. The women examined were $30{\sim}59$ years old with breast implants, the patients were classified into 3 groups according to age, $30{\sim}39$, $40{\sim}49$, and $50{\sim}59$, prior breast cancer, mastectomy or breast deformity were excluded. The digital readout of compressed breast compression force and thickness was recorded. Mammographic positioning was assessed using standard criteria. The mean compression force of the compressed breast on the craniocaudal projection was less than the mean compression force on the mediolateral projection(14 versus 13.88 daN, p<0.05). The mean thickness of the compressed breast for mediolateral projection was 41.46 mm and that for the craniocaudal projection was 39.50 mm(p<0.05). The compressed breast is higher or thicker on mediolateral oblique than on craniocaudal mammography.

  • PDF

Predicting the Concentration of Obesity-related Metabolites via Heart Rate Variability for Korean Premenopausal Obese Women: Multiple Regression Analysis (심박변이도를 통한 폐경 전 한국인 비만 여성의 비만 관련 대사체 농도 예측을 위한 회귀분석)

  • Kim, Jongyeon;Yang, Yo-Chan;Yi, Woon-Sup;Kim, Je-In;Maeng, Tae-Ho;Yoo, Duk-Joo;Shim, Jae-Woo;Cho, Woo-Young;Song, Mi-Yeon;Lee, Jong-Soo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.24 no.4
    • /
    • pp.155-162
    • /
    • 2014
  • Objectives Advanced researches on the relationship between obesity and heart rate variability (HRV), heretofore, focused on characteristics of HRV depending on the state of obesity. However, the previous researches have not quantified predictive power of HRV toward the obesity-related variables, which is rather more meaningful for clinicians who regularly treat obese patients. Hence, we designed a research to investigate whether HRV could predict serum levels of obesity-related metabolites. Methods Ninety obese premenopausal women meeting the inclusion criteria were recruited. The HRV test, blood sampling, and measurement of physical traits were conducted. Multiple regression analysis of the measurement data was carried out, putting obesity-related metabolites (insulin, glucose, triglyceride, hs-CRP, HDL, LDL, total cholesterol) as outcome variables and the others as predictors. To select appropriate predictive variables, the Akaike's Information Criterion (AIC) was applied. Normality and homoskedasticity of residuals for each model were tested to identify if there were any violations of the regression analysis's basic assumption. Logarithm transformation was used for the values of the concentration of metabolites and the HRV. Results The regression model including Total Power (TP) value and BMI had significant predictive power for serum insulin concentration (F(2, 88)=835.7, p<0.001, $R^2=0.95$). The regression coefficient of ln (TP) was -0.1002. However, it was not sure if the HRV could predict concentrations of other metabolites. Conclusions The results suggest that the Total Power (TP) value of the HRV can predict the level of serum insulin. If the BMI could be assumed as being constant, when the TP value is multiplied by n, the predicted change of insulin could be drawn by multiplying $n^{-0.1002}$. The uncertainty of this model can be assumed as approximately 5%.

A Study on the Improvement of Performance Testing System of Domestic Surveying Equipment (국내 측량장비 성능검사제도 개선방안 연구)

  • MIN, Kwan-Sik
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.1
    • /
    • pp.53-63
    • /
    • 2016
  • In this paper, we proposed the improvements for performance test and surveying equipment regulations, standards, methods and procedures, depending on the need of improving the legal system for surveying equipment in a diverse and sophisticated surveying industry. This research was performed first investigating the existing legal systems(Act on the establishment and management of spatial data, Framework act on national standards, ISO 17123, JIS B 7912) with respect to the surveying equipment performance testing and the research for IOS and KOLAS suggested the improvements on the application for the surveying equipment performance testing standard. More exactly, first, two years were presented for the surveying equipment performance testing cycle considering the precise accuracy of the instrument stability, purpose and frequency of use, etc. Second, the abolition of the measurement distance by grade and the upward or cross-grade adjustment of the single prism standards about the light wave rangefinder and total station were suggested for the improvement on survey equipment performance criteria. Third, since the main function of total station is focused on a three-dimensional coordinate measurement due to the improvement of surveying equipment performance testing, it was proposed to use the precision(repeatability) of the coordinate measuring method as an evaluation method.

Additional Improvement and Evaluation of Exhaust Ventilation Systems at Small and Medium Sized Enterprise (중.소규모 사업장의 국소배기장치 설치 실태와 문제점 및 개선방안)

  • Lim, Seong-Keun;Park, Doo-Yong;Kim, Won-Ki;Kim, Soo-Geun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Objectives : The purposes of this study were to evaluate exhaust ventilation systems(EVSs) and to suggest problems and improvements. Methods : For 50 small and medium-sized enterprises, we carried out evaluation of EVSs. We evaluated hoods with smoke tester and measurement of capture velocity. In addition, we used several indicators for performance evaluation designed in this study. Results : 1. Based on the smoke flow pattern and the criteria of occupational health and safety act, 67.8% of hoods were rated 'good' level at smoke test whereas 26.3% were rated 'good' level at measurement of capture velocity. 2. 29.3% of hoods, of which ratio of measured actual air flow at hood(Qah) to required ideal exhaust air flow at hood(Qih) was 1 or more, were rated 'good' level. 3. The % of EVS, of which ratio of measured actual air flow at stack(Qast) to total required ideal exhaust air flow at hood(Qith) was 1 or more, was 29.0%. 4. For the ratio of measured Qast to existing air flow at fan(Qfan), only 5% of EVSs were 1 or more and 26.0% were 0.8 or more but less than 1.0. 5. For the ratio of measured Qast to total measured actual exhaust air flow at hood(Qath), 74.0% were 0.8 or more but less than 1.0. 6. The percentage of EVS, of which ratio of total measured Qath to existing Qfan was 0.8 or more, was 19.0%. 7. The percentage of EVS, of which ratio of total measured Qath to total required ideal exhaust Qith was 1 or more, was 26.0%. 8. For the comprehensive evaluation indicators designed in this study, 29.0% were 0.8 or more. Conclusions : We found that few exhaust local ventilations at small and medium-sized enterprises were rated 'good' level and that most exhaust local ventilations had 'poor' design and installation. Therefore, relevant professional manpower and enterprises have to construct exhaust local ventilation where it is needed, and technical guidance and economic support are needed to improve 'poor' exhaust local ventilation after self-evaluation.

Development of Signal Processing Circuit for Side-absorber of Dual-mode Compton Camera (이중 모드 컴프턴 카메라의 측면 흡수부 제작을 위한 신호처리회로 개발)

  • Seo, Hee;Park, Jin-Hyung;Park, Jong-Hoon;Kim, Young-Su;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.16-24
    • /
    • 2012
  • In the present study, a gamma-ray detector and associated signal processing circuit was developed for a side-absorber of a dual-mode Compton camera. The gamma-ray detector was made by optically coupling a CsI(Tl) scintillation crystal to a silicon photodiode. The developed signal processing circuit consists of two parts, i.e., the slow part for energy measurement and the fast part for timing measurement. In the fast part, there are three components: (1) fast shaper, (2) leading-edge discriminator, and (3) TTL-to-NIM logic converter. AC coupling configuration between the detector and front-end electronics (FEE) was used. Because the noise properties of FEE can significantly affect the overall performance of the detection system, some design criteria were presented. The performance of the developed system was evaluated in terms of energy and timing resolutions. The evaluated energy resolution was 12.0% and 15.6% FWHM for 662 and 511 keV peaks, respectively. The evaluated timing resolution was 59.0 ns. In the conclusion, the methods to improve the performance were discussed because the developed gamma-ray detection system showed the performance that could be applicable but not satisfactory in Compton camera application.

The Usefulness of Liver Fibroscan Test Using Ultrasound Image (초음파영상을 이용한 간탄력도 검사의 유용성)

  • An, Hyun;Lee, Jin-Soo;Im, In-Chul;Yang, Sung-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.205-212
    • /
    • 2017
  • Chronic diffuse hepatopathy is one of the important clinical tasks to reduce mortality and morbidity due to liver cirrhosis, liver failure, and liver cancer. The purpose of this study was to evaluate the criteria for predicting liver and chronic liver disease using Fibroscan based on ultrasound diagnosis. Serum and liver stiffness measurement(kPa) were analyzed in 280 patients and cut-off values of liver stiffness measurement for predicting fatty liver and chronic diffuse hepatopathy were determined using ROC curve analysis. Bilirubin and PT(prothrombin time) were not related to disease prediction(p=0.243, p=0.115). Serum glucose and triglyceride levels were significantly higher in the liver (p<0.05). The cut-off value for predicting chronic diffuse hepatopathy was determined as 10.3 kPa(AUC 0.98, sensitivity 94.94%, specificity 94.93%) in the order of control group, fatty liver and chronic diffuse hepatopathy. Therefore, it will be used as a primary tool for the diagnosis of chronic liver disease patients with quantitative evaluation.

Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe ($8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발)

  • Nam, Min-Woo;Lee, Hee-Jong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.184-190
    • /
    • 2008
  • Various ECT techniques have been applied basically to assess the integrity of steam generator tithing in nuclear power plant. Among these techniques, the bobbin probe technique is applied generally to examine the volumetric flaws such as a crack-like defect and wear which is generally occurred on steam generator tubing, and additionally MRPC probe is used to examine closely tile top of tubesheet and bending regions due to the high possibility of cracking. Dent and bulge also may be formed on tube during installation process and operation of steam generator, but the dent and bulge indications greater than specific size criteria are recorded on examination report because these indications are not considered as flaw. These indications can be easily detected with bobbin probe and approximately sized with profile bobbin probe, but the size and shape can not be accurately verified. Accordingly, in this study, the $8{\times}1$ multi-array EC probe was designed to increase the measurement accuracy of the sectional profiling EC testing of tube. As a result, we would like to propose the application of $8{\times}1$ multi-array EC probe for the measurement of size and shape of profile change on steam generator tube in OPR-1000 nuclear power plant.

A Systematic Review on Accelerometer to Measure Activity of Daily Living of Patients with Stroke (뇌졸중 환자의 일상생활활동 평가도구인 가속도계에 대한 체계적 고찰)

  • Lee, Joo-Hyun;Park, Jin-Hyuck;Kim, Yeonju;Park, Hae Yean;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.5 no.2
    • /
    • pp.57-69
    • /
    • 2016
  • Objective: The purpose of this study was to systematically review the articles using accelerometer to measure activity of daily living of patients with stroke. Methods: Depending on selection criteria, 13 studies were searched for PubMed, EMBASE, and Cochrane library database from February 2014 to March 2014. A total of 331 papers were searched, and 13 of these were selected. Results: In studies of 13 selected, acute, subacute, and chronic patients with stroke were enrolled. The kind of accelerometer was uniaxial, biaxial, and triaxial, activity monitor. Measurement activities were mainly arm activity, walking activity, and attachment sites were also various depending on the measurement activities. A measured variable was the total number of activities, the movement speed of the patients, ratio between affected and non-affected, and motion analysis. The result indicated that significant correlation with the other assessment tools in all studies. Conclusions: Accelerometer will be applied with a tool for measuring activity of daily living of patients with stroke, depending on activities characteristics. Further, we need accelerometer studies to apply with a variety of assessment in clinical practice or community settings.