• Title/Summary/Keyword: Measurement and verification

Search Result 907, Processing Time 0.028 seconds

Development of a Measurement and Verification Scheme for Efficient Lighting Program (고효율조명기기 프로그램 성과의 계량 및 검증 기법의 개발)

  • Cho, Ki-Seon;Park, Jong-Jin;Rhee, Chang-Ho;Kim, Hoi-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.795-797
    • /
    • 2005
  • This paper describes a measurement & verification scheme for the high efferent lighting program in Demand Side Management (DSM), which was Introduced in the beginning of the 1980's in Korea With the dramatic changes in the circumstance of power industry in Korea. It is required the reviewing for the existing process of DSM programs and the development of the new process methods/standards on the evaluation of DSM programs. To design an accurate evaluation scheme for the high efficient lighting program. In this paper, we develop an evaluation prototype for the high efficient lighting program using measurements and stipulated factors. The proposed scheme is tested by practical measurements and modified stipulated factors Results from the case studios show the proposed scheme could provide the practical performance evaluation results with promising accuracy.

  • PDF

Verification of the Global Numerical Weather Prediction Using SYNOP Surface Observation Data (SYNOP 지상관측자료를 활용한 수치모델 전구 예측성 검증)

  • Lee, Eun-Hee;Choi, In-Jin;Kim, Ki-Byung;Kang, Jeon-Ho;Lee, Juwon;Lee, Eunjeong;Seol, Kyung-Hee
    • Atmosphere
    • /
    • v.27 no.2
    • /
    • pp.235-249
    • /
    • 2017
  • This paper describes methodology verifying near-surface predictability of numerical weather prediction models against the surface synoptic weather station network (SYNOP) observation. As verification variables, temperature, wind, humidity-related variables, total cloud cover, and surface pressure are included in this tool. Quality controlled SYNOP observation through the pre-processing for data assimilation is used. To consider the difference of topographic height between observation and model grid points, vertical inter/extrapolation is applied for temperature, humidity, and surface pressure verification. This verification algorithm is applied for verifying medium-range forecasts by a global forecasting model developed by Korea Institute of Atmospheric Prediction Systems to measure the near-surface predictability of the model and to evaluate the capability of the developed verification tool. It is found that the verification of near-surface prediction against SYNOP observation shows consistency with verification of upper atmosphere against global radiosonde observation, suggesting reliability of those data and demonstrating importance of verification against in-situ measurement as well. Although verifying modeled total cloud cover with observation might have limitation due to the different definition between the model and observation, it is also capable to diagnose the relative bias of model predictability such as a regional reliability and diurnal evolution of the bias.

A Study on On-line 5 Degrees of Freedom Error Measurement using Laser Optical System (레이져 광학장치를 이용한 온라인 5 자유도 오차측정에 관한연구)

  • 김진상;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.375-378
    • /
    • 1995
  • Although laser interferometer measurement system has the advantage of range and accuracy, the traditional error measurement methods for geometric errors(two straightness and three angular errors) of a machine tool measures error components one at a time. It may also create an optical path difference and affect the measurement accuracy. In order to identify and compensate for geometric error of a moving body, an on-line measurement system for simultaneous detection of the five error components of a moving axis is required. An on-line measurement system with 5 degrees of freedom was developed for geometric error detection. Performance verification of the system was performed on an error generating mechanism. Experimental results show the feasibility of this system for identifying geometric errors of a side of machine tool.

  • PDF

A Study on the Analysis for the Strength of Bailey Panel Bridge (장간조립교 주요 부재의 강도 분석 연구)

  • Lee, Jong-Woo;Yoo, Sam-Hyun;Kim, In-Soo;Kim, Tae-Yang;Choi, Hyun-Ho;Yoon, Woo-Seob;Kim, Young-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.15-21
    • /
    • 2011
  • In this paper, the results of experimental analysis for the chemical composition and strengh verification of Bailey Panel Bridge have been presented. Some of main sections of bailey bridge colllected from military engineer troops were prepared for the chemical composition and strengh verification. The composition test and strength verification were conducted by using the optical microscope and Scanning Electron Microscope(SEM), Automatic Control Spark Emission Spectrometer(OBLF), X-ray Fluorescence Spectroscopy(XRF) and Instron measurement. The results showed that currently used sections of bailey bridge passed the strength verification and could be operated in drill of troops and battle fields.

Performance verification of Ka-Band Array Antenna using Near-Field Test Method (근접전계 시험 기법을 활용한 Ka-대역 배열안테나 성능 검증)

  • Kim, Youngwan;Kwon, Junbeom;Kang, Yeonduk;Park, Jongkuk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.105-111
    • /
    • 2019
  • In this paper, a performance analysis of waveguide broad-wall slot array antenna for millimeter-wave seeker in Ka-band was performed as using near-field measurement. The measurement of slot array antenna was conducted in both far-field and near-field. And the validation of near-field test in millimeter band was confirmed. It was confirmed that the beam pattern characteristics including beam width and side lobe level of the slot array antenna that performed the verification were the same. Differenced in the side lobe level of azimuth and elevation beam pattern were verified to be less than 1dB. Additionally, the new antenna aperture distribution was extracted as using back-projection method modifying the near-field data and then introduced the method conducting performance analysis of array antenna.

Verification of Long-distance Vision-based Displacement Measurement System (장거리 영상기반 변위계측 시스템 검증)

  • Kim, Hong-Jin;Heo, Suk-Jae;Shin, Seung-Hoon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.47-54
    • /
    • 2018
  • The purpose of this study is to verify the long - range measurement performance for practical field application of VDMS. The reliability of the VDMS was verified by comparison with the existing monitoring sensor, GPS, Accelerometer and LDS. It showed the ability to accurately measure the dynamic displacement by tracking a motion of free vibration of target. And using the PSD function of measured data, the results in the frequency domain were also analyzed. We judged that VDMS is able to identify the higher system mode and has sufficient reliability. Based on the reliability verification, we conducted tests for long-distance applicability for actual application of VDMS. The distance from the stationary target model structure was increased by 50m interval, and the maximum distance was set to 400m. From the distance of 150m, the image obtained by the commercial camcorder has an error in the analysis, so the measured displacement comparison was performed between the LDS and the refractor telescope measurement results. In the measurement results of the displacement area of VDMS, the data validity was deteriorated due to the data shift by the external force and the quality degradation of the enlarged image. However, even under the condition that the effectiveness of the displacement measurement data of VDMS is low, the first mode characteristic included in the free vibration of the object is clearly measured. If the influence from the external environment is controlled and stable data is collected, It is judged that reliability of long-distance VDMS can be secured.

Calibration of Borehole Roughness Measurement System for Large Diameter Drilled Shafts in Water (수중에서 적용가능한 대구경 현장타설말뚝의 굴착공 벽면거칠기 측정장치의 보정에 관한 연구)

  • Park, Bong-Geun;Nam, Moon-S.;Choi, Yong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.8
    • /
    • pp.5-21
    • /
    • 2009
  • Based on recent studies on rock socketed drilled shafts, it was found that the side resistance of rock socketed drilled shafts is affected by unconfined compressive strength of rock, socket roughness, rock types and joints, and initial normal stress. Especially, the socket roughness is affected by rock types and joints, drilling methods, and diameters. Since existing roughness measurement systems could be conducted only in the air, a new roughness measurement system, which can measure rock socket roughness in the air and also in the water, is needed. However, the development of new roughness measurement system fur civil engineers has been faced with difficulties of electrical applications. In this study, the laboratory verification system far BKS-LRPS (Backyoung-KyungSung Laser Roughness Profiling System) was developed, which can be applied both in the water and air. Based on the laboratory verification, it was found that the improved BKS-LRPS could define effective measurement distances for the conditions reflecting the apparatus and in-situ situations.

A Study on FTA-related Administrative Efficiency Measures for Verifying the Origin (FTA 원산지검증행정의 효율화 방안에 대한 연구)

  • Chung, Jae-Wan
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.55
    • /
    • pp.243-264
    • /
    • 2012
  • This study is aimed to analyze problems related to FTA country of origin of goods verification which is increasing from 2006 and thereby to grope for solution of such problems and seek adequate FTA performance administration. It is found, through comparative analysis and statistics of last 8 FTAs so far Korea has concluded that there are major problems such as excessive verification processing due to complicated country of origin regulation etc. This paper suggests following policies of country of origin administration ; (1) Simplification of FTA country of origin rules (2) reciprocal cooperation between each country's Customs Authorities based on trust (3) rational measurement against corresponding country's Customs Authorities' misbehavior (4) enhancement of transparency in relation to processing rule of country of origin verification (5) securing FTA country of origin verification experts. For these improvements, upcoming FTA shall rule country of origin reasonably, simplification and transparency of rule is needed for established FTAs in relation to FTA performance administration with corresponding countries. Also it is necessary to revise FTA preferential tariff law and its related laws, and carry forward policies in accordance with medium and long term plan.

  • PDF

Verification on the Measurement Uncertainty for Surface Roughness (표면거칠기측정에 대한 측정불확도 추정방법)

  • Kim, Chang-Soon;Park, Min-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.40-45
    • /
    • 2010
  • Evaluation of uncertainty is an ongoing process that can consume time and resources. It can also require the service of someone who is familiar with data analysis techniques. Therefore, it is important for laboratory personnel who are approaching uncertainty analysis for the first time to be aware of the resources required. International inclination of measurement filed to guarantee the traceability and confidence of measurement results discards the error concept and instead analyzes the measurement uncertainty. In this paper, we analyzed the elements of measurement uncertainty on surface roughness test which are the important things in mechanical parts test. Repeat the test by 3 men, the measurement uncertainty could be calculated.

A Study of Real Time Verification System or Radiation Therapy (방사선치료 위치 실시간 검증시스템에 관한 연구)

  • Kim, Y.J.;Ji, Y.H.;Lee, D.H.;Lee, D.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.164-167
    • /
    • 1997
  • The treatment setup of patients during irradiation is an important aspect in relation to the success of radiotherapy. Imaging with the treatment beam is a widely used method or verification of the radiation field position relative to the target area, prior to or during irradiation. In this paper, Real time digital radiography system was implemented or verification of local error between simulation plan and radiation therapy machine. Portal image can be acquired by CCD camera, image board and pentium PC after therapy Radiation was converted into light by a metal/fluorescent Screen. The resulting image quality is comparable to film, so the imaging system represents a promising alternative to film as a method of verifying patient positioning in radiotherapy. Edge detection and field size measurement were also implemented and detected automatically for verification of treatment position. Field edge was added to the original image or checking the anatomical treatment verification by therapy technicians. By means of therapy efficiency improvement and decrease of Radiation side effects with these techniques, Exact Radiation treatments are expected.

  • PDF