• Title/Summary/Keyword: Measurement accuracy

Search Result 3,985, Processing Time 0.038 seconds

Design and Implementation of a DSP-Based Multi-Channel Power Measurement System

  • Jeon Jeong-Chay;Oh Hun
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.214-220
    • /
    • 2005
  • In order to improve energy efficiency and solve power disturbances, power components measurement for both the supply and demand side of a power system must be implemented before appropriate action on the power problems can be taken. This paper presents a DSP (Digital Signal Processor)-based multi-channel (voltage 8-channel and current 10-channel) power measurement system that can simultaneously measure and analyze power components for both supply and demand. Voltage 8-channel and current 10-channel measurement is made through voltage and current sensors connected to the developed system, and power components such as reactive power, power factor and harmonics are calculated and measured by the DSP. The measured data are stored in a personal computer (PC) and a commercial program is then used for measurement data analysis and display. After voltage and current measurement accuracy revision using YOKOGAWA 2558, the developed system was tested using a programmable ac power source. The test results showed the accuracy of the developed system to be about 0.3 percent. Also, a simultaneous measurement field test of the developed system was implemented by application to the supply and demand side of the three-phase power system.

Flexible camera series network for deformation measurement of large scale structures

  • Yu, Qifeng;Guan, Banglei;Shang, Yang;Liu, Xiaolin;Li, Zhang
    • Smart Structures and Systems
    • /
    • v.24 no.5
    • /
    • pp.587-595
    • /
    • 2019
  • Deformation measurement of large scale structures, such as the ground beds of high-rise buildings, tunnels, bridge, and railways, are important for insuring service quality and safety. The pose-relay videometrics method and displacement-relay videometrics method have already presented to measure the pose of non-intervisible objects and vertical subsidence of unstable areas, respectively. Both methods combine the cameras and cooperative markers to form the camera series networks. Based on these two networks, we propose two novel videometrics methods with closed-loop camera series network for deformation measurement of large scale structures. The closed-loop camera series network offers "closed-loop constraints" for the camera series network: the deformation of the reference points observed by different measurement stations is identical. The closed-loop constraints improve the measurement accuracy using camera series network. Furthermore, multiple closed-loops and the flexible combination of camera series network are introduced to facilitate more complex deformation measurement tasks. Simulated results show that the closed-loop constraints can enhance the measurement accuracy of camera series network effectively.

Effect of Cone Angle of a Seven-Hole Probe on the Accuracy Flow Measurement (7공 프로브의 원추각이 유동 측정 정확도에 미치는 영향에 대한 연구)

  • Lee, Yong-Jin;Park, Jung-Shin;Nho, Young-Cheol;Jeon, Chang-Soo;Kwak, Jae-Su
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.5
    • /
    • pp.5-11
    • /
    • 2011
  • In this study, the effect of cone angle of seven-hole probe on the accuracy of measured flow angle and velocity has been investigated. The seven-hole probe consisted of seven 1mm OD stainless inner tubes and one 3mm ID stainless tube. Six cone angles of $45^{\circ}$, $60^{\circ}$, $75^{\circ}$, $90^{\circ}$, $105^{\circ}$ and $120^{\circ}$ were tested. Calibrations of the seven-hole probes were conducted within ${\pm}60^{\circ}$ range with the interval of $5^{\circ}$. Analysis results show that the effect on the cone angle was not significant on the accuracy of the measured flow angle, pressure, and velocity. However, the data reduction method had more effect on the measurement accuracy.

Hybrid TDOA/AOA Localization Algorithm for GPS Jammers (GPS 전파교란원 위치 추정을 위한 TDOA/AOA 복합 기법 설계)

  • Lim, Deok Won;Kang, Jae Min;Heo, Moon Beom
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.1
    • /
    • pp.101-105
    • /
    • 2014
  • For a localization system, the TDOA (Time Difference of Arrival) measurement and AOA (Angle of Arrival) measurement are often used for estimating target's positions. Although it is known that the accuracy of TDOA based localization is superior to that of AOA based one, it may have a poor vertical accuracy in bad geometrical conditions. This paper, therefore, proposes a localization algorithm in which the vertical position is estimated by AOA measurements and the horizontal one is estimated by TDOA measurement in order to achieve high 3D-location accuracy. And this algorithm is applied to a GPS jammer localization systems because it has a large value of the DOP (Dilution of Precision) when the jammer is located far away from the system. Simulation results demonstrate that the proposed hybrid TDOA/AOA location algorithm gives much higher location accuracy than TDOA or AOA only location.

TEST AND PERFORMANCE ANALYSIS METHODS OF LOW EARTH ORBIT GPS RECEIVER (지구저궤도 GPS 수신기의 시험 및 성능 분석 방법)

  • Chung Dae-Won;Lee Sang-Jeong
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.3
    • /
    • pp.259-268
    • /
    • 2006
  • The use of GPS receiver at outer space becomes common in low earth orbit. Recently most of satellites use GPS receiver as navigation solution for finding satellite position. However, the accuracy of navigation solution acquiring directly from GPS receiver is not enough in satellite application such as map generation. Post-processing concepts such as Precise Orbit Determination (POD) are recently applied to satellite data processing to improve satellite position accuracy. The POD uses raw measurement data instead of navigation solution of GPS receiver. The performance of raw measurement data depends on raw measurement data accuracy and tracking loop algorithm of GPS receiver. In this paper, a method for evaluating performance of raw measurement data is suggested. Test environment and procedure of the low earth orbit satellite acquiring for navigation solution of GPS receiver and navigation solution of POD are described. In addition, accuracy on navigation solution of GPS receiver, raw measurement data, and navigation solution of POD are analyzed. The proposed method can be applicable to general low earth orbit satellite.

Assessing the accuracy of electric energy monitoring system (전기 에너지 모니터링 시스템의 신뢰성 평가 방안)

  • You, Young Hag;Leem, Choon Seong;Choi, Dae Soon
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.53-60
    • /
    • 2018
  • In order to manage energy efficiency by analyzing the amount of energy, it would determine the nature of the factors involved in the energy utilization. Therefore, accurate measurement of the energy consumption data is an important factor in the energy management. In this study, we are aware of the importance of the data measurement, and proposes the accuracy assessment of electric energy monitoring system. According to conventional statistical methods it is proceeded as follows; i)the measurement error value would be determined by a random variable, ii) setting the confidence interval to consider the distribution of the statistic and determines the confidence level of the measurement accuracy. And using the t-distribution CDF is used to facilitate even small sample data.

Evaluating the Accuracy of Blood Pressure Measurement in General Hospital Nurses (종합병원 간호사의 혈압측정의 정확성 평가)

  • Kim Jong-Sook;Kim Sang-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.1
    • /
    • pp.7-15
    • /
    • 2000
  • To assess the accuracy of blood pressure measurement in general hospital nurses, 276 nurses at four hospital in Kyungju city and Pohang city were observed during the study period 20 December 1998 to 29 December 1998. The nurses measuring the blood pressure of simulated patient's were checked by the researcher or 20 items, that are recommended for consideration when doing a blood pressure measurement. Of the six items in the preparation step for measuring blood pressure, the accuracy of 'patients shouldn't talk during the procedure' had the lowest frequency(27.1%) and the other five items were above 80%. Of the ten items on blood pressure measuring technique, the accuracy of the frequency for 'inflating the cuff until the radial or brachial artery pulse is no longer palpable and then adding 30mmHg' was 0%, 'waiting $30{\sim}60$ seconds before reinflating the cuff' was alse 0%, 'rapidly deflating the cuff', 0.3%, 'rapidly and steadily inflating the cuff to the maximal level as per above-mentioned initial systolic pressure assessment step', 0.7%, 'reading the pressure to the nearest 2mmHg mark on the manometer', 10.8%, the remaining items were above 70%. Of the four items on blood pressure recording, the accuracy of 'recording the cuff size' had a frequency of 0.3%, 'recording the patient's position such as sitting, standing or lying position', 10.8%, 'recording the arm or leg which was used for measuring the blood pressure', 53.6%, and 'recording systolic/diastolic pressure', 100%. The variables significantly related to the accuracy of the blood pressure measurement were age, career position at hospital, and qualification education for blood pressure measurement(p<0.01). In the multiple regression analysis, position and qualification education were significant variables(p<0.01). In conclusion, the accuracy of blood pressure measurement was very low, thus, qualification education for blood pressure measurement should be done immediately to improve the accuracy of measurement by nurses in general hospitals.

  • PDF

An Analysis of Performance Error of High Precision Measuring Instrument (진원도 측정기의 오차특성에 관한 연구)

  • 한응교;노병옥;허민석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.862-874
    • /
    • 1989
  • A phase evil method and spectrum analysis were instrument error which is originated from measurement system and the form error of standard specimens. An instrument with a rotating table supported by an air bearing is calibrated using standard specimens. The phase of standard specimens was measured 12 times on the rotating table with rotating 30 in turn and its measurement magnification was set by 100000 times. As a result of data analysis of all the observations, read out at each of 144 orientations(per 2.5) from recorded datafiles, the error of the performance of the instrument and those of the standard specimens are evaluated and a systematic deviation of the instrument is determined. In the particular instrument used in the present experiment, the deviation of the instrument is determined with the accuracy of 15nm and those of standard specimens with the accuracy of 23, 13 n, respectively. The reproducibility of the instrument is investigated, too. If the instrument is calibrated by using the above standard specimens, then the accuracy of the measurement of roundness error can be improved to about 15nm.

Rotational Accuracy Measurement of Scroll Compressor with D-type Sectional Shaft

  • Park, Sang-Shin;Kim, Gyu-Ha;Lee, Jin-Kab
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.125-127
    • /
    • 2002
  • This paper presents the measurement process of the rotational accuracy and the comparison with the theoretical results in the main bearing of scroll compressor. The main bearing is cylindrical oil proceeding bearing, but there are straightly cut used for oil supply. Therefore the roundness error is not a negligible quantity compared with the rotational accuracy. For this reason, three-point method is used in the experiment. The result of three-point method coincides with the theoretical value. So if the theory in this paper is used to the bearing design of scroll compressor, the efforts for testing and designing can be reduced.

  • PDF

A study on the OMM error compensation considering the thermally induced errors (열변형 오차를 고려한 기상측정 오차 보정에 관한 연구)

  • 박규백;송길홍;조명우;권혁동;서태일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.399-404
    • /
    • 2002
  • Improvement of measuring accuracy is an essential part of quality control manufacturing process. The OMM is less than the CMM in measure accuracy but the OMM system is more efficient, easier to use than other measurement system. About 40~70% of the machine tool errors are induced by the thermal errors. Therefore, a key requirement for improving the measuring accuracy is to reduce the geometric and thermal errors. Thermal errors are measured by a ball bar system and predicted by the thermal error modeling. Furthermore, using the pre-defined thermal error map approach compensates the geometric accuracy of the OMM. Appropriate experiments are performed using ball-bar system, temperature measuring devices and touch-type probe. Compensated results are compared with those obtained using CMM to verify the proposed methods.

  • PDF