A study on the OMM error compensation considering the thermally induced errors

열변형 오차를 고려한 기상측정 오차 보정에 관한 연구

  • Published : 2002.05.01

Abstract

Improvement of measuring accuracy is an essential part of quality control manufacturing process. The OMM is less than the CMM in measure accuracy but the OMM system is more efficient, easier to use than other measurement system. About 40~70% of the machine tool errors are induced by the thermal errors. Therefore, a key requirement for improving the measuring accuracy is to reduce the geometric and thermal errors. Thermal errors are measured by a ball bar system and predicted by the thermal error modeling. Furthermore, using the pre-defined thermal error map approach compensates the geometric accuracy of the OMM. Appropriate experiments are performed using ball-bar system, temperature measuring devices and touch-type probe. Compensated results are compared with those obtained using CMM to verify the proposed methods.

Keywords