• Title/Summary/Keyword: Measurement Unit

Search Result 1,725, Processing Time 0.024 seconds

Analysis of Walking Characteristics according to the Disposition of the Acceleration Measuring Unit for the PNS (개인 항법시스템을 위한 가속도 측정장치의 배치에 따른 보행 특성 분석)

  • Lee, Jun-Ho;Cho, Sung-Yoon;Jin, Yong;Park, Chan-Guk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.439-439
    • /
    • 2000
  • In this paper, the relationship among the vertical acceleration, measuring points and walking patterns is analyzed. To measure acceleration, the acceleration measurement unit and communication board is constructed. It uses MEMS accelerometer ADXL-202 that detects 2-axis acceleration simultaneously. It is shown by the experiment test that the walking pattern is recognized and walking step is detected at easy when acceleration measurement unit is mounted on leg.. This results can be directly utilized in designing the personal navigation system with low-cost inertial sensor.

  • PDF

Analyses of the Basic Inquiry Process in Korean 3-10 Grade Science Textbooks: Focused on Observation and Measurement (우리나라 3-10학년 과학 교과서에 나타난 기초탐구과정 분석: 관찰 및 측정 탐구요소를 중심으로)

  • Park, Bo-Hwa;Kim, Hee-Kyong;Lee, Bong-Woo
    • Journal of The Korean Association For Science Education
    • /
    • v.27 no.5
    • /
    • pp.421-431
    • /
    • 2007
  • The purpose of this study was to examine the characteristics of observation and measurement inquiry process in the Korean science textbooks. For the inquiry process of observation, the higher grade textbooks contained more 'comparative observation' rather than 'simple observation'. Students should express their observation results in written words rather than verbal descriptions in the higher grade. For the inquiry process of measurement, the temperature measurement was the most frequent measurement activity. 'Measurement design' was found more frequently in the lower grade textbooks. The uses of measurement tools were not presented systematically and were presented restrictively when the relevant experiment wanted to use these tools. The higher grade textbooks include 'quantitative measurements' rather than 'qualitative measurements' and 'operation measurement' rather than 'simple measurement'. In the application of measurement results, we had difficulty in finding the activities related with the usage of unit, unit conversion, significant figure, error and uncertainty.

Reliability of 3D-Inertia Measurement Unit Based Shoes in Gait Analysis (관성센서 기반 신발형 보행 분석기의 신뢰성 연구)

  • Joo, Ji-Yong;Kim, Young-Kwan;Park, Jae-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.123-130
    • /
    • 2015
  • Purpose : The purpose of this study was to investigate the reliability of 3D-inertia measurement unit (IMU) based shoes in gait analysis. This was done with respect to the results of the optical motion capturing system and to collect reference gait data of healthy subjects with this device. Methods : The Smart Balance$^{(R)}$ system of 3D-IMU based shoes and Osprey$^{(R)}$ motion capturing cameras were used to collect motion data simultaneously. Forty four healthy subjects consisting of individuals in 20s (N=20), 40s (N=13), and 60s (N=11) participated in this study voluntarily. They performed natural walking on a treadmill for one minute at 4 different target speeds (3, 4, 5, 6 km/h), respectively. Results : Cadence (ICC=.998), step length (ICC=.970), stance phase (ICC=.845), and double-support phase (ICC=.684) from 3D-IMU based shoes were in agreement with results of optical motion system. Gait data of healthy subjects according to different treadmill speeds and ages were matched to previous literature showing increased cadence and reduced step length for elderly subjects. Conclusion : Conclusively, 3D-IMU based shoes in gait analysis were a satisfactory alternative option in measuring linear gait parameters.

A Study on the In-process Measurement of Metallic Surface roughness in Cylindrical Grinding by Diode Laser (원통연삭가공시 반도체 레이저 빔을 이용한 금속표면거칠기의 인프로세스 측정)

  • 김희남
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.03a
    • /
    • pp.1-8
    • /
    • 1995
  • This paper proposed a simple method for measuring surface roughness of ground surface. utilizing non-contact in-process measuring system using the diode laser. The measurement system is consisted of a laser unit with a diode laser and a cylindrical lens a detecting unit with polygon mirror and CCD array sensor. and a signal processing unit with a computer and device. During operation, this measuring system can provide information on surface roughness in the measuring distance with a single sampling and simultanilusly monitor the state of the grind wheel. The experimental results, showed that the increase of the feed rate and the dressing speed an caused increase in the surface roughness and when the surface roughness is 4Rmax-10Rmax, the cutting speed is 1653m/min-1665m/min. the feed rate is 0.2m/min-0.9m/min, the dressing speed is 0.2mm/rev-0.4mm/rev, the stylus method and the in-process method can be obtained the same results. thus under limited working conditions. using the proposed system. the surface roughness of the ground surface during cylindrical grinding can be obtained through the in-process measurement method using the diode laser.

  • PDF

Optimal Placement of Phasor Measurement Unit for Observation Reliability Enhancement

  • TRAN, Van-Khoi;ZHANG, He-sheng;NGUYEN, Van-Nghia
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.996-1006
    • /
    • 2017
  • Phasor Measurement Unit (PMU) placement is a crucial problem for State Estimation (SE) of the power system, which can ensure that the power network is fully observed. Further, the observation reliability problem of the system has been concerned in the operation conditions. In this paper, based on modified weighted adjacent matrix ($A_w$), an optimal placement method is proposed to solve simultaneously two problems involving the optimal PMU placement problem and the observation reliability enhancement problem of the system. The purpose of the proposed method is to achieve both the minimum total cost and the maximum observation reliability, with a focus on increasing the security of observability, strengthening the observation reliability of buses as well as enhancing the effectiveness of redundancy. Simulations on IEEE 14, 24, 30 and 57 bus test systems are presented to justify the methodology. The results of this study show that the proposed method is not only ensuring the power network having the observability effectively but also enhancing significantly the observation reliability. Therefore, it can be a useful tool for SE of the power system.

A Study on the In-Process Measurement of Metallic Surface Roughness in Cylindrical Grinding by Diode Laser (원통연삭가공시 반도체 레이저 빔을 이용한 금속표면거칠기의 인프로세스 측정)

  • 김희남;이주상
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.30-41
    • /
    • 1995
  • This paper proposed a simple method for measuring surface roughness of ground surface. Utilizing non-contact in-process measuring system using the diode laser. The measurement system is consisted of a laser unit with a diode laser and a cylindrical lens, a detecting unit with polygon mirror and CCD array sensor, and a signal processing unit with a computer and device. During operation, this measuring system can provide information on surface roughness in the measuring distance with a single sampling and simultaniously monitor the state of the grind wheel. The experimental results, showed that the Increase of the feed rate and the dressing speed an caused increase in the surface roughness and when the surface roughness is 4Rmax-10Rmax, the cutting speed is 1653m/min-1665m/min, the table speed is 0.2n1/min -0.9m/min, the dressing speed is 0.2mm/rev~0.4mm/rev, the stylus method and the in-process method can be obtained the same results. Thus, under limited working conditions, using the proposed system, the surface roughness of the ground surface during cylindrical grinding can be obtained through the in-process measurement method using the diode laser.

  • PDF

Life Test Design and Evaluation of Inertial Measurement Unit for Guided Weapons (유도무기용 관성측정기 수명 시험 설계 및 평가)

  • Jo, Kyoung Hwan;Moon, Sang Chan;Yun, Suk Chang;Kwon, Seung Bok;Kim, Do Hyung;Yang, Il Young
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.5
    • /
    • pp.94-101
    • /
    • 2022
  • In this paper, we have obtained the acceleration coefficient of the IMU (Inertial Measurement Unit) to prove reliability by analyzing the characteristic of the MEMS IMU installed in guided weapon systems for overseas export and the operating environment of the guided weapon system. Additionally, based on designed life testing, we performed life tests on three the IMUs and demonstrated a target lifetime of 12 years.

Repeatability of the Measurement of Electrical Taste Detection Thresholds in Healthy Young Females

  • Hee Noh;Yeong-Gwan Im;Byung-Gook Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.4
    • /
    • pp.144-151
    • /
    • 2023
  • Purpose: The aim of this study was to assess the repeatability of the electrical measurement of taste detection on different dates and in different sessions in healthy young females. Methods: The sites of electrical stimulation were the tip of the tongue, the posterolateral border of the tongue and the soft palate on the right side unilaterally. The measurements were repeated over three consecutive days, three sessions per day and three times for each session in seventeen healthy females. The repeatability of the measurement was assessed by the intraclass correlation coefficient (ICC). Results: In the dB unit, the ICC of the tip of the tongue and the soft palate was good (61.03 and 66.03, respectively); however, the lateral border of the tongue was a little lower (58.07). In the ㎂ unit, all three test sites had poor ICC. Variability was more significantly associated with the subject factor than with other factors such as trials, sessions and days in dB and ㎂ units. Conclusions: Electrogustometry, which measures electrical taste detection thresholds in the dB unit, is repeatable and acceptable for clinical use in assessing taste function in healthy young females.

A study on progress measurement method of a construction project (건설공사의 진도율 산정 방법에 관한 연구)

  • Park se-Jung;Kim Soo-Yong
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.450-453
    • /
    • 2003
  • It is very important to examine and compare initial plan with earned value repeatedly in construction. For this purpose, progress measurement, which reflects the actual progress correctly, is required and it is necessary that accurate field data should be offered. To measure the progress, the entire project mutt be divided into unit works that have an accurate scope of work, and required information must be distributed to the all parties. Under the circumstances of domestic construction industry which focus on the specifications, progress measurement needs to reflect the information of schedule as well as cost that includes the quantity of unit work and construction expenses. Therefore this research proposes weighted method of progress measurement based on the information of cost and schedule.

  • PDF

Underwater Hybrid Navigation Algorithm Based on an Inertial Sensor and a Doppler Velocity Log Using an Indirect Feedback Kalman Filter (간접 되먹임 필터를 이용한 관성센서 및 초음파 속도센서 기반의 수중 복합항법 알고리듬)

  • 이종무;이판묵;성우제
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.6
    • /
    • pp.83-90
    • /
    • 2003
  • This paper presents an underwater hybrid navigation system for a semi-autonomous underwater vehicle (SAUV). The navigation system consists of an inertial measurement unit (IMU), and a Doppler velocity log (DVL), accompanied by a magnetic compass. The errors of inertial measurement units increase with time, due to the bias errors of gyros and accelerometers. A navigational system model is derived, to include the scale effect and bias errors of the DVL, of which the state equation composed of the navigation states and sensor parameters is 20. The conventional extended Kalman filter was used to propagate the error covariance, update the measurement errors, and correct the state equation when the measurements are available. Simulation was performed with the 6-d.o,f equations of motion of SAUV, using a lawn-mowing survey mode. The hybrid underwater navigation system shows good tracking performance, by updating the error covariance and correcting the system's states with the measurement errors from a DVL, a magnetic compass, and a depth sensor. The error of the estimated position still slowly drifts in the horizontal plane, about 3.5m for 500 seconds, which could be eliminated with the help of additional USBL information.