• 제목/요약/키워드: Measurement Uncertainty Analysis

검색결과 328건 처리시간 0.023초

엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석 (Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test)

  • 양인영
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

표면거칠기측정에 대한 측정불확도 추정방법 (Verification on the Measurement Uncertainty for Surface Roughness)

  • 김창순;박민원
    • 한국정밀공학회지
    • /
    • 제27권4호
    • /
    • pp.40-45
    • /
    • 2010
  • Evaluation of uncertainty is an ongoing process that can consume time and resources. It can also require the service of someone who is familiar with data analysis techniques. Therefore, it is important for laboratory personnel who are approaching uncertainty analysis for the first time to be aware of the resources required. International inclination of measurement filed to guarantee the traceability and confidence of measurement results discards the error concept and instead analyzes the measurement uncertainty. In this paper, we analyzed the elements of measurement uncertainty on surface roughness test which are the important things in mechanical parts test. Repeat the test by 3 men, the measurement uncertainty could be calculated.

3차원 좌표 측정기 성능 시험법에 대한 측정 불확도 해석 (Measurement Uncertainty Analysis of Performance Test for Coordinate Measuring Machine)

  • 이승표;강형주;하성규
    • 한국정밀공학회지
    • /
    • 제26권4호
    • /
    • pp.91-99
    • /
    • 2009
  • Because of both precise measurement and efficient quality control, coordinate measuring machines(CMMs) have been widely used in the industry. The purpose of this paper is to present a method to estimate the CMM measurement uncertainty using design of experiments. A factorial design is applied to carry out the performance test proposed by ISO 10360 and to investigate CMM measurement errors associated to orientation and length of the length bar. In order to assess the measurement uncertainty for the performance test, an analysis of the uncertainty components that make up the uncertainty budget has been carried out. The procedure for evaluating the uncertainty of it follows GUM ("Guide to the expression of uncertainty in measurement"). The results show that the proposed method is suitable to investigate CMM performance and determine the contribution of machine variables to measurement uncertainty.

측정불확도의 개념과 GUM (The Concept of Measurement Uncertainty and the GUM)

  • 이종화
    • 대한화학회지
    • /
    • 제67권5호
    • /
    • pp.319-332
    • /
    • 2023
  • Guide to the Expression of Uncertainty in Measurement (GUM)가 발간된 1993년부터 측정불확도는 측정학의 핵심 개념으로 여겨져 왔으며 적절한 불확도 평가의 중요성은 꾸준히 높아지고 있다. 하지만 측정불확도의 개념과 GUM에 대해 충분히 정확하고 상세하게 설명하는 국문 자료는 거의 없는 실정이다. 본 총설은 측정불확도 개념과 GUM의 수학적, 역사적, 철학적 배경을 상세하게 설명하며 화학 분야 불확도 평가의 특수성을 논한다.

버어리종 담배 중 질산성 질소에 대한 측정불확도 (Uncertainty of Measurement in Nitrate Analysis from Burley Leaf Tobacco)

  • 이정민;이경구;한상빈
    • 한국연초학회지
    • /
    • 제27권2호
    • /
    • pp.226-234
    • /
    • 2005
  • The uncertainty of measurement in nitrate from burley leaf tobacco by continuous-flow analysis method was evaluated following internationally accepted guidelines. The sources of uncertainty associated with the analysis of nitrate were weight of standard and sample, purity of standard, dilution of standard solution, calibration curve, water content, etc. The calculation of uncertainty based on the GUM(Guide to the Expression of Uncertainty in Measurement) and EURACHEM/CITAC Guide. An expanded uncertainty was obtained by multiplying the combined standard uncertainty with a coverage factor (k) calculated from the effective degree of freedom. The concentration of nitrate from burley leaf tobacco was $2.09\%$ and the expanded uncertainty by multiplying by the coverage factor(k, 2.20) was $0.13\%\;at\;a\;95\%$ confidence level.

유량계 교정장치의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Flowmeter Calibrator)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

차량 사고 분석에서 측정의 불확실성 (Uncertainty of Measurements in the Analysis of Vehicle Accidents)

  • 한인환;박승범
    • 대한교통학회지
    • /
    • 제28권3호
    • /
    • pp.119-130
    • /
    • 2010
  • 교통사고의 재구성 해석은 도로와 사고흔적, 자동차 손상 등 다양한 자료들을 분석함으로서 이루어진다. 대부분의 자료들은 사고 해석에서 변수로 작용하며, 측정으로부터 구해지는 자료들은 조사자와 도구, 주어진 환경 등에 의해 측정 오차가 발생된다. 따라서 사고해석에서는 측정 오차에서 비롯되는 불확실성이 항상 존재한다. 본 연구는 불확실성이 존재할 가능성이 매우 높은 도로 기하구조와 타이어 흔적 등 길이와 마찰계수 등에 대해 반복 측정 실험을 함으로서 교통 사고해석에서의 불확실성을 정량화하였다. 또한 자동차 충돌 변형량의 사진 계측에 대한 불확실성에 대해서도 해석 결과를 제시하였다. 이러한 통계학적 분포들은 사고 재구성 불확실성을 추정하기 위해 입력 계수의 적절한 범위를 결정하는 것을 도울 수 있다.

고정밀 이송기구의 위치결정정밀도에 대한 측정불확도 요소 분석 (Measurement Uncertainty Analysis of Positioning Accuracy for High Precision Feed Mechanism)

  • 이정훈;윤상환;박민원
    • 한국정밀공학회지
    • /
    • 제29권5호
    • /
    • pp.494-499
    • /
    • 2012
  • Reliable results can't be derived without the notion of measurement uncertainty. The reason is that the measured value includes a lot of uncertain factors. Finding the factor that affect the measurement of parameter is important for estimation of measurement uncertainty. In this paper, the evaluation of uncertainty analysis about positioning accuracy measurements of high precision feed mechanism is presented to evaluate the important factors of uncertainty.

GUM 기반 측정불확도의 평가 및 적용에 의한 품질개선 (A Study on Quality Improvement by Evaluation and Application of GUM-based Measurement Uncertainty)

  • 최인수;허선
    • 품질경영학회지
    • /
    • 제51권3호
    • /
    • pp.419-434
    • /
    • 2023
  • Purpose: Measurement results obtained under non-ideal measurement environment conditions may contain uncertain factors. As a result, the reliability of measurement results may be deteriorated. In this study, we tried to find ways to improve quality by evaluating and applying measurement uncertainty based on GUM. Methods: In the flatness measurement of semiconductor parts, uncertainty factors that could occur under actual environmental conditions of workers were derived, and measurement uncertainties were calculated, and methods for minimizing the main factors affecting the measurement results were analyzed. Results: Depending on the part and the coordinate measuring machine, it was shown that the effect of dispersion caused by repeated measurements as type A uncertainty and the effect of the calibration results of equipment as type B uncertainty have the main influence. Conclusion: Depending on the uncertainty factors of type A and type B and the influence of the total expanded uncertainty, the central value and confidence interval of the initial measurement results showed fluctuations. It is considered that analysis and measures for the main uncertainty factors are needed as quality improvement in the industrial field.

버어리종 담배중 암모니아성 질소에 대한 불확도 측정 (Uncertainty Evaluation of Ammonia Determination in Burley Tobacco)

  • 이정민;이경구;한상빈
    • 한국연초학회지
    • /
    • 제27권1호
    • /
    • pp.107-114
    • /
    • 2005
  • The uncertainty of measurement in quantitative analysis of ammonia by continuous-flow analysis method was evaluated following internationally accepted guidelines. The sources of uncertainty associated with the analysis of ammonia were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the reproducibility of analysis and the determination of water content in tobacco, etc. In calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier's catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the volume measurement of 1 mL and 2 mL, the purity of ammonia reference material in the preparation of standard solution, the reproducibility of analysis and the determination of water content of tobacco. The uncertainty in the addition of extraction solution, the sample weighing, the volume measurement of 50 mL and 100 mL, and the calibration curve of standard solution contributed relatively little to the overall uncertainty. The expanded uncertainty of ammonia determination in burley tobacco at $95\%$ level of confidence was $0.00997\%$.