• 제목/요약/키워드: Measurement Techniques

검색결과 1,890건 처리시간 0.028초

Ultrafine Particle의 독성, 측정방법 및 관리 (Ultrafine Particle Toxicities, Current Measurement Techniques and Controls)

  • 이수길;김성수
    • 한국산업보건학회지
    • /
    • 제20권3호
    • /
    • pp.203-215
    • /
    • 2010
  • This study is an overview of toxicities and measurement techniques of ultrafine particles (UFPs), and their exposure controls. UFPs are ubiquitous in many working situations. Exposure to UFPs is possibly causing adverse health symptoms including cardio-respiratory disease to humans. In order to measure exposure levels of airborne UFPs, there are current available measurement guidelines, instruments and other techniques (i.e. contour mapping, control banding). However, these risk assessment techniques including measurement techniques, controls and guidelines are dependent on background levels, metrics (e.g. size, mass, number, surface area, composition), environmental conditions and controls. There are no standardized measurement methods available and no generic and specific occupational exposure standards for UFPs. It is thought that there needs to be more effort to develop Regulations and Exposure Standards for generic UFPs should be based on more exposure data, health surveys, toxicological data and epidemiological data. A carefully considered hierarchy of controls can also reduce the maximum amount of airborne UFPs being emitted from diverse sources in industries.

하천유량 측정기법에 관한 연구 (A Study on the River Discharge Measurement Techniques)

  • 김성원;지홍기
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

The Use of Advanced Optical Measurement Methods for the Mechanical Analysis of Shear Deficient Prestressed Concrete Members

  • Wilder, K. De;Roeck, G. De;Vandewalle, L.
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권2호
    • /
    • pp.189-203
    • /
    • 2016
  • This paper investigates on the use of advanced optical measurement methods, i.e. 3D coordinate measurement machines (3D CMM) and stereo-vision digital image correlation (3D DIC), for the mechanical analysis of shear deficient prestressed concrete members. Firstly, the experimental program is elaborated. Secondly, the working principle, experimental setup and corresponding accuracy and precision of the considered optical measurement techniques are reported. A novel way to apply synthesised strain sensor patterns for DIC is introduced. Thirdly, the experimental results are reported and an analysis is made of the structural behaviour based on the gathered experimental data. Both techniques yielded useful and complete data in comparison to traditional mechanical measurement techniques and allowed for the assessment of the mechanical behaviour of the reported test specimens. The identified structural behaviour presented in this paper can be used to optimize design procedure for shear-critical structural concrete members.

Comparison of Different Techniques for Measurement of Cold Work in Mild Steel

  • Badgujar, B.P.;Jha, S.K.;Goswami, G.L.
    • 비파괴검사학회지
    • /
    • 제23권6호
    • /
    • pp.616-621
    • /
    • 2003
  • There are various Non-Destructive Evaluation (NDE) techniques used for measurement of residual stresses in material, such as magnetic methods, X-ray diffraction, Ultrasonic velocity measurement etc. The capabilities, applications and limitations of these techniques for evaluation of cold work/plastic deformation were studied and compared. Mild steel plates were subjected to different degree of cold deformation and were analyzed by Magneto-mechanical Acoustic Emission (MAE), Barkhausen Noise (BN) and magnetic properties (hysteresis loop parameters analysis). Further, these specimens were analyzed by X-ray diffraction and ultrasonic velocity measurements. The microhardness measurement and microstructure studies of these cold worked plates were also carried out. The results of all these studies and comparison of different techniques are discussed in this paper.

대기중 이산화황 관측 방법들의 실측 비교 연구 (An Intercomparison of Atmospheric SO$_{2}$ Measurement Techniques)

  • 김경렬;이동수;이강웅
    • 한국대기환경학회지
    • /
    • 제12권5호
    • /
    • pp.587-591
    • /
    • 1996
  • An intercomparison experiment was implemented to assess the uncertainties and precisions om atmospheric SO$_{2}$ measurement techiques including a pulsed fluorescence (P-F), a diffusion-scrubber /ion chromatography (D-I), and a mist-chamber/ion chromatography (M-I). Each of those three techniques was investigated by researchers at Seoul National University, Yonsei University, and Hankuk University of Foreign Studies, respectively. The concentrations of atmospheric SO$_{2}$ were determined concurrently using three independent measurement techniques at the Seoul National University campus, Korea during Nov.22 to Dec.2, 1995. While the results from the P-F and D-I techinques showed the very close agreements (within +-5%) throughout the experiment period, M-I technique showed systematically smaller values (up to 30%) than the other two techniques. Although sources of larger discrepancy between different techniques were mot identified, the lower SO$_{2}$ values of the M-I method may be related to the errors associated with sample collection effciency, mass flow rate measurements, and standardization of ion chromatography.

  • PDF

시분해 레이저 유도 백열법을 이용한 에틸렌 확산 화염에서의 매연 일차입자크기 측정에 관한 연구 (Study on Soot Primary Particle Size Measurement in Ethylene Diffusion Flame by Time-Resolved Laser-Induced Incandescence)

  • 김규보;조승완;이종호;정동수;장영준;전충환
    • 대한기계학회논문집B
    • /
    • 제30권10호
    • /
    • pp.973-981
    • /
    • 2006
  • Recently there is an increasing interest in particulate matter emission because of new emission regulations, health awareness and environmental problems. It requires to improve particulate measurement techniques as well as to reduce soot emissions from combustion systems. As mentioned above, it is demanded that reduction techniques together with measurement techniques of exhausted particulate matters in combustion systems such as vehicles. However, measurement techniques of particulate matters should be prior to reduction techniques of that because it is able to know an increase and a decrease of exhausted particulate matters when measured particulate matters. Therefore, in this study, we report the measurement of soot primary-particle size using time-resolved laser induced incandescence (TIRE-LII) technique in laminar ethylene diffusion flame. As an optical method, laser induced incandescence is one of well known methods to get information for spatial and temporal soot volume fraction and soot primary particle size. Furthermore, TIRE-LII is able to measure soot primary particle size that is decided to solve the decay ate of signal S $(t_1)$ and S $(t_2)$ at two detection time. In laminar ethylene diffusion flame, visual flame height is 40 mm from burner tip and measurement points are height of 15, 20, 27.5, 30 mm above burner tip along radial direction. As increasing the height of the flame from burne. tip, primary particle size was increased to HAB(Height Above Burner tip)=20mm, and then decreased from HAB=27.5 mm to 30 mm. This results show the growth and oxidation processes for soot particles formed by combustion.

A comparative analysis of structural damage detection techniques by wavelet, kurtosis and pseudofractal methods

  • Pakrashi, Vikram;O'Connor, Alan;Basu, Biswajit
    • Structural Engineering and Mechanics
    • /
    • 제32권4호
    • /
    • pp.489-500
    • /
    • 2009
  • The aim of this paper is to compare wavelet, kurtosis and pseudofractal based techniques for structural health monitoring in the presence of measurement noise. A detailed comparison and assessment of these techniques have been carried out in this paper through numerical experiments for the calibration of damage extent of a simply supported beam with an open crack serving as an illustrative example. The numerical experiments are deemed critical due to limited amount of experimental data available in the field of singularity based detection of damage. A continuous detectibility map has been proposed for comparing various techniques qualitatively. Efficiency surfaces have been constructed for wavelet, kurtosis and pseudofractal based calibration of damage extent as a function of damage location and measurement noise level. Levels of noise have been identified for each technique where a sudden drop of calibration efficiency is observed marking the onset of damage masking regime by measurement noise.

첨단 유동가시화 기법들과 Blue Ocean 전략 (Advanced Flow Visualization Technologies and Blue Ocean Strategy)

  • 이상준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.145-146
    • /
    • 2006
  • Recently, the next-generation advanced flow visualization techniques such as holographic PIV, dynamic PIV, echo-PIV, micro/nano-PIV, and X-ray PIV have been introduced. These advanced measurement techniques have a big potential as the core technology for analyzing outmost thermo-fluid flows in future. These would be indispensable in solving complicated thermo-fluid flow problems not only in the industrial fields such as automotive, space, electronics, aero- and hydro-dynamics, steel, and information engineering, but also in the research fields of medical science, bio-medical engineering, environmental and energy engineering etc. Especially, NT (Nano Technology) and BT (Bio Technology) strongly demand these advanced measurement techniques, because it is impossible for conventional measurement methods to observe most complicated nano- and bio-fluidic phenomena. In this presentation, the basic principle of these high-tech flow visualization techniques and their practical applications which cannot be resolved by conventional methods, such as blood flows in a micro-tube, in vivo analysis of micro-circulation, and flow around a living body will be introduced as a blue ocean strategy.

  • PDF

Precise Comparison of Two-dimensional Dopant Profiles Measured by Low-voltage Scanning Electron Microscopy and Electron Holography Techniques

  • Hyun, Moon-Seop;Yoo, Jung-Ho;Kwak, Noh-Yeal;Kim, Won;Rhee, Choong-Kyun;Yang, Jun-Mo
    • Applied Microscopy
    • /
    • 제42권3호
    • /
    • pp.158-163
    • /
    • 2012
  • Detailed comparison of low-voltage scanning electron microscopy and electron holography techniques for two-dimensional (2D) dopant profiling was carried out with using the same multilayered p-n junction specimen. The dopant profiles obtained from two methods are in good agreement with each other. It demonstrates that reliability of dopant profile measurement can be increased through precise comparison of 2D profiles obtained from various microscopic techniques.

임펠러 출구에서의 비정상 유동 측정 기법 (Measurement Techniques on Unsteady Flow at Impeller Exit)

  • 신유환;김광호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.123-128
    • /
    • 1998
  • This study presents the measurement techniques on the periodic fluctuating flow such as the discharge flow of a centrifugal impeller in unstable operating region. During rotating stall, the flow at the exit of a centrifugal compressor impeller fluctuates periodically with lower frequency than that of the blade passing. To observe the blade-to-blade flow characteristics during rotating stall, the phases of all the sampled data sets should be adjusted to those of the reference signals with two processes, in these processes, DPLEAT (Double Phase-Locked Ensemble Averaging Technique) can be used. From these measurement and data processing techniques, the characteristics not only on the blade-to-blade flow with high frequency, but also on the periodic rotating stall flow with low frequency at the centrifugal impeller exit can be clearly observed.

  • PDF