• Title/Summary/Keyword: Measurement Table

Search Result 453, Processing Time 0.026 seconds

Finite Element Model Updating and System Identification of Reinforced Concrete Specimen (철근콘크리트 실험체의 시스템 식별과 유한요소 모델 수정)

  • Kim, H.J.;Yu, E.J.;Kim, H.G.;Chang, K.K.;Lee, S.H.;Cho, S.H.;Chung, L.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.725-731
    • /
    • 2008
  • This paper focused on the application of finite element model updating technique to evaluate the structural properties of the reinforced concrete specimen using the data collected from shaking table tests. The specimen was subjected to six El Centre (NS, 1942) ground motion histories with different peak ground acceleration (PGA) ranging from 0.06 g to 0.50 g. For model updating, flexural stiffness values of structural members (walls and slabs) were chosen as the updating parameters so that the converged results have direct physical interpretations. Initial values for finite element model were determined from the member dimensions and material properties. Frequency response functions (i.e. transfer functions), natural frequencies and mode shapes were obtained using the acceleration measurement at each floor and given ground acceleration history. The weighting factors were used to account for the relative confidence in different types of Inputs for updating (j.e. transfer function and natural frequencies) The constraints based on upper/lower bound of parameters and sensitivity-based constraints were implemented to the updating procedure in this study using standard bounded variable least-squares(BVLS) method. The veracity of the updated finite element model was investigated by comparing the predicted and measured responses. The results indicated that the updated model replicates the dynamic behavior of the specimens reasonably well. At each stage of shaking, severity of damage that results from cracking of the reinforced concrete member was quantified from the updated parameters (i.e. flexural stiffness values).

사업 포트폴리오의 기술시너지 효과 : 50대 재벌의 패널자료분석

  • 김태유;박경민
    • Journal of Technology Innovation
    • /
    • v.5 no.1
    • /
    • pp.15-43
    • /
    • 1997
  • This paper investigates empirically the relationship between various business portfolio properties (particularly technological properties) and chaebol's performance using data on the 50largest chaebols in Korea. In addition to the traditional indexes to measure diversification such as entropy index, we calculated inter-industry technological similarity using R'||'&'||'D expenditure data by industry and 1990 Input-output Table in korea, and obtained chaebol-level technological relatedness and internal transaction proportion from chaebols' business profile, inter-inustry technological similarity and 1990 input-output table. We applied factor analysis on 13 business portfolio property indexes and showed that they could be grouped into 3 dimensions. diversification scope, inter-business relatedness and degree of vertical integration. In this paper, using 50 largest chaebols' financial data (1989-1994), we analyzed empirically the effect of business portfolio properties on ROS(Return On Sales) which is conventional index for firm performance and on TFP(Total Factor Productivity) growth which is a pure measure of firm performance. To utilize the advantage of panel data, FEM(Fixed Effect Model) and REM(Random Effect Model) were used. The empirical result shows that the entropy index as a measurement of inter-business relatedness in not significant but technological relatedness index is significant. OLS estimates on pooled data were considerably different from FEM or REM estimates on panel data. By introducing interaction effect among the three variables for business portfolio properties, we obtained three findings. First, only VI(Vertical integration) has a significant positive correlation with ROS. Second, when using TFP growth as an dependent variable, both TR(Technological Relatedness) and VI are significant and positively related to the dependent variable. Third, the interaction term between TR and VI is significant and negatively affects TFP growth, meaning that TR and VI are substitutes. These results suggest strategic directions on restructuring business portfolio. As VI is increased, chaebols will get more profit. A higher level of either TR or VI will increase TFP growth rate, but increase in both TR and VI will have a negative effect on TFP growth. To summarize, certain business portfolio properties such as VI and TR can be considered "resources" themselves since they can affect profit rate and productivity growth. VI and TR have a synergy effect of change in profit rate and productivity growth. VI increases ROS and productivity growth, while TR increases productivity growth representing a technological synergy effect.t.

  • PDF

Comparing Efficiency of Numerical Cadastral Surveying Using Total Station and RTK-GPS (토탈스테이션과 RTK-GPS 측량을 이용한 수치지적측량의 작업효율성 비교)

  • Hong, Sung-Eon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.3
    • /
    • pp.87-96
    • /
    • 2007
  • In the numerical cadastral surveying field, the cadastral surveying would be measured with the Total Station surveying (electronic plane table surveying) system that consist the Total Station for surveying and the computing system for recording and editing the measured coordinates data by the TS. This study would suggest the advanced method, which is used on the RTK-GPS instead of TS for surveying and the computing system for handling the coordinates data and mapping. As a result of this study, although the measurement accuracy of the RTK-GPS and TS surveying make no greate difference, the suggested method reduces the cost of time and work force with the TS surveying. Besides, the new survey method would be more efficient due to directly handling the data and mapping in the field.

  • PDF

A Study on the Facility Accessibility of the Wheelchaired Persons for the Concept of Universal Design (휠체어 사용자의 Universal Access를 위한 시설 접근성 연구)

  • Jin, Sangeun;Yoo, Youngmi;Lee, Junhee;Park, Wongu
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.54-61
    • /
    • 2018
  • Objective: The current study aimed to investigate the accessibility and usability of the disabled person while using the everyday facility. Background: The national laws regulated accommodation of persons with disabilities, but our knowledge on the practical usefulness of the laws and acceptance by the users is still far from complete. Method: Compliance with laws was checked throughout the actual measurement of 87 engineering designs in the facilities of a national university, and the practical usability of the facilities was investigated by in-depth interviews with eight disabled persons. New design solutions were developed by the anthropometric methodology for better accommodation. The target-specific anthropometry database such as sitting knee height with wheelchair was employed. Results: First, the statistic showed that 28.7% of facility designs comply with the law, 29.9% of facility designs doesn't comply with the law, and 41.4% of facility designs doesn't have related law or regulation. Second, the law of table height(71cm in current) can accommodate only 49.3% of wheelchaired population. The following test for 95% accommodation revealed that the table with 80cm high is required. Third, the current law in the door width(90cm) can only accommodate 82.6% of disabled persons, so the new design solution was calculated and suggested that 100cm in the door width is necessary for 99% accommodation of disabled persons. Conclusion: Even with the laws and regulations for the disabilities it was clear that the accessibility and usability of the disabled persons in everyday facilities was still limited. An investigation for the new solutions about a wide range of facilities is necessary for better practical accessibility and usability of the handicapped persons. Application: The results of current study can be a basement of developing a new guideline or regulation of the facility design for the disabled persons.

A Energy Theft Traceback Protocol in a Smart Grid Environment (스마트 그리드 환경에서 에너지 도둑 추적 프로토콜)

  • Jeong, Eun-Hee;Lee, Byung-Kwan;Ahn, Hui-Hak
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.6
    • /
    • pp.534-543
    • /
    • 2015
  • This paper proposes an Energy Theft Traceback Protocol(ETTP) based on Logging and Marking that can trace Energy Theft back in Smart Grid Environment. The ETTP consists of the following three phases. First, it classifies Energy Theft Type into Measurement Rejection and Data Fabrication by generating an Energy Theft Tree. Second, it detects an Energy Theft by using the Energy Theft Tree. Finally, it trace an Energy Theft back by using the Logging Table of a Router and the Marking Information of a Packet. The result of its simulation shows that the Detection Ratio of Energy Theft is estimated at 92% and the Success Ratio of Energy Theft Traceback at 93%. Therefore, the ETTP not only reduces such risk factors as Forgery and Tampering about Billing information but also provides safe and reliable Smart Grid environment.

A Study on the Effectiveness of Information Retrieval (정보검색효율에 관한 연구)

  • Yoon Koo-ho
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.8
    • /
    • pp.73-101
    • /
    • 1981
  • Retrieval effectiveness is the principal criterion for measuring the performance of an information retrieval system. The effectiveness of a retrieval system depends primarily on the extent to which it can retrieve wanted documents without retrieving unwanted ones. So, ultimately, effectiveness is a function of the relevant and nonrelevant documents retrieved. Consequently, 'relevance' of information to the user's request has become one of the most fundamental concept encountered in the theory of information retrieval. Although there is at present no consensus as to how this notion should be defined, relevance has been widely used as a meaningful quantity and an adequate criterion for measures of the evaluation of retrieval effectiveness. The recall and precision among various parameters based on the 'two-by-two' table (or, contingency table) were major considerations in this paper, because it is assumed that recall and precision are sufficient for the measurement of effectiveness. Accordingly, different concepts of 'relevance' and 'pertinence' of documents to user requests and their proper usages were investigated even though the two terms have unfortunately been used rather loosely in the literature. In addition, a number of variables affecting the recall and precision values were discussed. Some conclusions derived from this study are as follows: Any notion of retrieval effectiveness is based on 'relevance' which itself is extremely difficult to define. Recall and precision are valuable concepts in the study of any information retrieval system. They are, however, not the only criteria by which a system may be judged. The recall-precision curve represents the average performance of any given system, and this may vary quite considerably in particular situations. Therefore, it is possible to some extent to vary the indexing policy, the indexing policy, the indexing language, or the search methodology to improve the performance of the system in terms of recall and precision. The 'inverse relationship' between average recall and precision could be accepted as the 'fundamental law of retrieval', and it should certainly be used as an aid to evaluation. Finally, there is a limit to the performance(in terms of effectiveness) achievable by an information retrieval system. That is : "Perfect retrieval is impossible."

  • PDF

The Clinical Application of Sound-Protection

  • Tomohiko, Kamio
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1976.06a
    • /
    • pp.87.1-87
    • /
    • 1976
  • Bekesy measured the sound transformation system of the middle ear 49 years ago. According to his reports, a ratio between the size of ear drum and the size of oval window is 17 : 1, and the lever function of the ossicles is physiologically 1.3 : 1. Therefore, the hearing might be aggravated to 27.5㏈ in the case of the vanishment of 3 ossicles. In 1952, Wullstein reported 5 types of tympanop-lasty and the fourth type among them was especially named for the sound-protection. The oval window is only exposed by the sound pressure and the round window is not exposed. According to the application by this idea, the post-operative hearing might be improved until 27.5㏈. Mean while, in 1942, Onchi verified through his experiment that the results of Bekesy's measurement was not completely conformed to Onchi result. Bekesy measured the sound pressure on the stapes plate of the oval window, on the other hand, Onchi measured the sound pressure on the surface of the perilymph of the oval window after removing the stapes plate(Fig. 1).(Figure omitted) The difference of their experiment is recognized that the impedance of the stapes plate exists or not (Fig. 1). Both Audiogrums are compared as Fig. 2. The result of IV type of tympanoplasty is success ful in 54% as the Table 1. (Table Omitted) The reason of unsatisfactory is caused by the thick and unmovable window-membrane and by the closing of air passage to the round window. The closing of the air passage to the round window is occurred by the adhesion between the grafting membrane and the surface of promontorium. In order to preserve this adhesion, I produce to transplantate the mucous membrane of the lip to the bone surface of tympanic cavity after removing the granulation tissue of the tympanic cavity and to form a membranous canal for the sake of air passage (Fig. 3). (Figure Omitted) The post-operative hearing by this method is shown as Fig. 4, 5. In other words, the post-operative sound pressure entered into the cochlea directly, by way of the oval window only, not by way of the round window, as a theorie of the sound protection. (Figure omitted)

  • PDF

Modeling and experimental verification of phase-control active tuned mass dampers applied to MDOF structures

  • Yong-An Lai;Pei-Tzu Chang;Yan-Liang Kuo
    • Smart Structures and Systems
    • /
    • v.32 no.5
    • /
    • pp.281-295
    • /
    • 2023
  • The purpose of this study is to demonstrate and verify the application of phase-control absolute-acceleration-feedback active tuned mass dampers (PCA-ATMD) to multiple-degree-of-freedom (MDOF) building structures. In addition, servo speed control technique has been developed as a replacement for force control in order to mitigate the negative effects caused by friction and inertia. The essence of the proposed PCA-ATMD is to achieve a 90° phase lag for a structure by implementing the desired control force so that the PCA-ATMD can receive the maximum power flow with which to effectively mitigate the structural vibration. An MDOF building structure with a PCA-ATMD and a real-time filter forming a complete system is modeled using a state-space representation and is presented in detail. The feedback measurement for the phase control algorithm of the MDOF structure is compact, with only the absolute acceleration of one structural floor and ATMD's velocity relative to the structure required. A discrete-time direct output-feedback optimization method is introduced to the PCA-ATMD to ensure that the control system is optimized and stable. Numerical simulation and shaking table experiments are conducted on a three-story steel shear building structure to verify the performance of the PCA-ATMD. The results indicate that the absolute acceleration of the structure is well suppressed whether considering peak or root-mean-square responses. The experiment also demonstrates that the control of the PCA-ATMD can be decentralized, so that it is convenient to apply and maintain to real high-rise building structures.

Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images (3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Choi Seong-Ho;Kim Chong-Kwan;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF

Efficiency Evaluation of CT Simulator QA Phantom (전산화 단층촬영 모의치료기 정도관리 팬텀의 유용성 평가)

  • Hwang, Se-Ha;Min, Je-Sun;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Purpose: The purpose is to evaluate efficiency of the CT simulator QA phantom manufactured for daily QA. Materials and Methods: We made holes ($1{\times}100{\times}1\;mm$) to verify accuracy between image and real measurement in polystyrene phantom and made 1 mm holes to verify table movement accuracy at superior and inferior 100 mm to the center of the phantom and inserted radiopacity material. To evaluate laser alignment, we made cross mark on the right and left side at phantom and to evaluate CT number accuracy we made 3 cylindrical holes and inserted equivalence material of bone, water, air in them. After CT scanning the phantom, We evaluated accuracy between image and real measurement, accuracy of table movement, laser, and CT number using exposed image. Results: It was measured that the accuracy between image and real measurement was ${\pm}0.3\;mm$, table movement accuracy was ${\pm}0.3\;mm$, laser accuracy was ${\pm}0.5\;mm$ from 7th January to 7th March in 2008 as within the reference point ${\pm}1\;mm$. In the CT number accuracy of bone was ${\pm}10\;HU$, air was ${\pm}5\;HU$, water was ${\pm}5\;HU$ as within the reference point is ${\pm}10\;HU$. Conclusion: We was able to perform CT simulator QA and laser equipment QA more conveniently and fast using manufactured phantom at the same time. We will be able to make more accurate treatment plan that added to QA procedures using images at previous daily QA.

  • PDF