• 제목/요약/키워드: Measurement Reliability

검색결과 2,383건 처리시간 0.033초

작업환경측정 신뢰성평가제도 개선방안에 관한 연구 (tudy on the Improvement of Reliability Assessment of Work Environment Measurement in Korea)

  • 황규석
    • 한국산업보건학회지
    • /
    • 제29권1호
    • /
    • pp.50-56
    • /
    • 2019
  • Objective: The aim of this study is to analyze the reliability assessment of work environment measurement, and to propose ways of improving the system. Methods: We have reviewed reports and articles on the reliability assessment written by KOSHA and academia in order to analyze problems related with the system and propose the alternatives. Results: There are three ways to improve the system of the reliability assessment. First of all, it is necessary to perform the reliability assessment by measuring the work environment when workers raise questions about the results so we can make workers trust these results of the reliability assessment. Secondly, we should inspect the workplace at first, not the work environment service provider, so we can increase the employer's recognition of his duty to practice the work environment measurement. Thirdly, the technical committee is needed for technical issues related with the work environment measurement. Conclusions: Above all, it is crucial to get the workers' interest and trust to improve the work environment measurement. The reliability assessment should support the meaning and value of the work environment measurement by practicing the reliability assessment whenever workers have a demand for this and operating the technical committee.

발목관절 복합체의 가동범위 측정을 위한 중립위치와 측정방법의 신뢰도 (Reliability of the Joint Neutral Position and Measurement Methods of the Ankle Joint Complex Range of Motion)

  • 홍완성;김기원
    • The Journal of Korean Physical Therapy
    • /
    • 제23권4호
    • /
    • pp.45-51
    • /
    • 2011
  • Purpose: To determine the correct measurement methods of the ankle joint complex range of motion for measuring the neutral position and evaluate the rater reliability. In addition, the impact of training on the rater reliability was also assessed. Methods: The subjects were eleven healthy women, who were evaluated by two physical therapists and one physical therapist recorded the results of the study. Standard goniometer was used as the measurement tool. The ankle and subtalar joint neutral position and the active range of motion of the ankle and subtalar joint were measured. Intra-rater reliability and inter-rater reliability measures were analyzed with intraclass correlation coefficients. Results: Intra-rater reliability and inter-rater reliability ranged from high to medium for the neutral position of the ankle joint complex. Intra-rater reliability for dorsiflexion and plantarflexion measurements was medium, while the inter-rater reliability was high. The range of motion of the subtalar joint was measured, and the intra-rater reliability and inter-rater reliability were low and medium, respectively Also, the intra-rater reliability was increased with formal training of the measurement techniques. Intra-rater reliability was reduced in case the raters had not undertaken the training. Conclusion: In summary, the results obtained with the measurement tools and joint measurement of position, indicate the consistency of repeated measurements made by the same observers. Under the same circumstances along with repetition of the same measurement technique during training caused an increase in the rater reliability of formally trained raters.

줄자를 이용한 하지부피 측정시 부위별 검사자간, 검사자내 신뢰도 측정 (Intertester and Intratester Reliability of Tape Measurement on Lower Extremities)

  • 김성중;양회송;이충휘
    • 한국전문물리치료학회지
    • /
    • 제7권1호
    • /
    • pp.38-45
    • /
    • 2000
  • Tape measurement for evaluating edema is frequently used by clinicians. The primary purpose of this study is to determine the intertester and intratester reliability of tape measurement carried out by two physical therapists on lower extremities. The intertester and intratester reliability of six anatomical landmarks measurements were determined in six healthy subjects. The measurements were taken in five sessions by each tester. The intraclass correlation coefficients (2,1) were between .87 and .99 for intertester reliability. Intratester reliability was .93 and .99 for A tester and .82 and .99 for B tester. The average range of variation was .13 to .54 in six landmarks. The reliability of six volume measurements was very high. These results support the use tape measurement as a reliable tool for measuring limb girth.

  • PDF

Reliability and Validity of Measurement Using Smartphone-Based Goniometer of Tibial External Rotation Angle in Standing Knee Flexion

  • Jeon, In-Cheol;Kwon, Oh-Yun;Weon, Jong-Hyuck;Ha, Sung-Min;Kim, Si-Hyun
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.60-68
    • /
    • 2013
  • The purpose of this study was to assess the intra-rater test-retest reliability of tibial external rotation angle measurement using a smartphone-based photographic goniometer, DrGoniometer (DrG) compared to a three-dimensional motion analysis system (Vicon). The current study showed an interchangeable method using DrG to measure the tibial external rotation angle in standing knee flexion at $90^{\circ}$. Twelve healthy subjects participated in this study. A rest session was conducted 30 minutes later for within-day reliability and five days later for between-day intra-rater test-retest reliability. To assess the validity of the measurement using DrG, we used a three dimensional motion analysis system as a gold standard to measure the angle of tibial external rotation. Intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) values were used to determine the within- and between- day intra-rater test-retest reliability of using DrG and a three dimensional motion analysis system. To assess validity, Pearson correlation coefficients were used for two measurement techniques. The measurement for tibial external rotation had high intra-rater test-retest reliability of within-day (ICC=.88) and between-day (ICC=.83) reliability using DrG and of within-day (ICC=.93) and between-day (ICC=.77) reliability using a three-dimentional motion analysis system. Tibial external rotation angle measurement using DrG was highly correlated with those of the three-dimensional motion analysis system (r=.86). These results represented that the tibial external rotation angle measurement using DrG showed acceptable reliability and validity compared with the use of three-dimensional motion analysis system.

줄자 및 사진촬영 측정을 이용한 어깨뼈 벌림 측정에 대한 신뢰도 연구 (A Reliability Study of Tape and Photography Measurement Techniques for Scapular Position)

  • 김문환;윤성준;하성민
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.74-80
    • /
    • 2013
  • The purpose of this study was to determine the reliability of distance measurements from the medial border of the scapula to the spinous process of the thoracic vertebrae when obtained using tape and photography measurements. The study included 20 healthy subjects (10 males, 10 females); for a total of 40 scapula measurements. The distance measurements made using tape or photography methods were conducted with the subject in a standing position. Repeated tape and photography measurements were conducted in two sessions on different days by two examiners to assess the inter-rater and intra-rater reliability of the two methods. The reliability of scapular distance measured using tape and photography methods was tested using intraclass correlation coefficients (ICC(3,1)) and the standard error of measurement (SEM). The inter-rater reliability of the tape measurement method was excellent (ICC=.77) and the intra-rater reliability was fair to good (ICC=.74). The inter-rater and intra-rater reliabilities of the photography measurement method were excellent (ICC=.76 and .76 respectively). Our results suggest that photography measurement is an objective and qualitative measurement tool for scapular distance measurements.

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

  • Min, Hye-jin;Yoon, Tae-lim
    • 한국전문물리치료학회지
    • /
    • 제26권3호
    • /
    • pp.76-83
    • /
    • 2019
  • Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen's kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

국내 작업환경 측정결과 신뢰성 향상을 위한 제도 고찰 (A Review of a System for Improving the Reliability of Domestic Measurement Results regarding the Work Environment)

  • 김기연;강태선;이승길;박해동;정지연
    • 한국산업보건학회지
    • /
    • 제27권2호
    • /
    • pp.87-96
    • /
    • 2017
  • Objectives: Improvement of the reliability of work environment measurement results is one of the principal subjects to be resolved in the field of industrial hygiene. Thus, this study was conducted in order to review domestic programs for enhancing the reliability of work environment measurement results and propose a more efficient management plan for workplace monitoring. Materials and Methods: The current domestic programs reviewed in this study are the quality control system and evaluation system for industrial hygiene laboratories, the reliability system accompanied by KOSHA (the Korea Occupational Safety and Health Agency), the system of permissible exposure limits and observed inspection system for permissible exposure limits. Their contents and data were analyzed by reviewing articles, reports, and guidelines related to reliability improvement for work environment measurement results. Results: As a result of the literature review, all the domestic programs investigated in this study had both merits and demerits in terms of considering the reliability of work environment measurement results. In particular, the fact that preliminary notification is provided to the head of a workplace before implementation would be an obstacle for elevating the reliability of work environment measurement results. Conclusions: Based on the review results obtained from this study, it is proposed that on-site measurement without preliminary notification should be considered for a more efficient inspection system that would enhance the reliability of workplace monitoring.

원전 배관의 두께 측정 데이터에 대한 신뢰도 분석 방법 및 적용 (Method and Application for Reliability Analysis of Measurement Data in Nuclear Power Plant)

  • 윤훈;황경모;이효승;문승재
    • Corrosion Science and Technology
    • /
    • 제14권1호
    • /
    • pp.33-39
    • /
    • 2015
  • Pipe wall-thinning by flow-accelerated corrosion and various types of erosion is significant damage in secondary system piping of nuclear power plants(NPPs). All NPPs in Korea have management programs to ensure pipe integrity from degradation mechanisms. Ultrasonic test(UT) is widely used for pipe wall thickness measurement. Numerous UT measurements have been performed during scheduled outages. Wall-thinning rates are determined conservatively according to several evaluation methods developed by Electric Power Research Institute(EPRI). The issue of reliability caused by measurement error should be considered in the process of evaluation. The reliability analysis method was developed for single and multiple measurement data in the previous researches. This paper describes the application results of reliability analysis method to real measurement data during scheduled outage and proved its benefits.

측정 품질과 신뢰도 향상을 위한 교정주기 분석 프로그램의 개발 및 응용 (Development and Application of Calibration Interval Analysis Program for Measurement Quality and Reliability Improvement)

  • 박병선;안웅환;조중재
    • 품질경영학회지
    • /
    • 제34권1호
    • /
    • pp.54-72
    • /
    • 2006
  • In recent years, the widespread application of quality management and measurement reliability has put increasing emphasis on procedures for periodic instrument calibration. By optimizing calibration intervals, unnecessary calibrations can be minimized, thereby reducing costs. Moreover, optimizing intervals will improve compliance with regulatory directives while ensuring maximal compliance with reliability targets. In this paper, we present Calibration Interval Analysis Program developed using several establishment methodologies of calibration interval for measurement quality and reliability improvement. Also, we perform calibration interval analysis for some measurement instruments and analyse its results.

신뢰도 측정을 통한 효과적인 웹 사이트 구축 방안에 관한 연구 (A Study on Effective Web Site Implementation using Reliability Measurement)

  • 권영직;최군;권동훈
    • 한국멀티미디어학회논문지
    • /
    • 제14권6호
    • /
    • pp.802-812
    • /
    • 2011
  • 본 논문에서는 문헌연구를 통하여 효과적인 웹 사이트 구축을 위한 신뢰도 요인 7개를 도출하였고, 이를 토대로 웹 사이트의 신뢰도 측정도구인 "Xenu"와 "Yslow"를 이용하여 실증적으로 웹 사이트의 신뢰도를 측정하였다. 실험한 웹 사이트의 수는 국내, 외 12개를 선정하였다. 이들 12개의 웹 사이트에 대하여 신뢰도를 측정한 결과 7개의 측정요인 별로 신뢰도 수준은 다양하게 나타났으며, 효과적인 웹 사이트 구축을 위해서 이들 7개의 측정요인별로 대안을 제시하여 두었다.