• Title/Summary/Keyword: Measurement Protocols

Search Result 108, Processing Time 0.028 seconds

Determination of Quality Factors for Cylindrical Ionization Chambers in kV X-rays: Review of IAEA Dosimetry Protocol and Monte Carlo Calculations and Measurements for N23333 and N30001 Chambers (kV X-선에서 원통형전리함의 선질인자 결정에 관한 연구: IAEA 프로토클 고찰과 N23333, N30001 전리함에 대한 몬테칼로 계산 및 측정)

  • Lee Kang Kyoo;Lim Chunil;Chang Sei Kyung;Moon Sun Rock;Jeong Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.53-61
    • /
    • 2005
  • The quality factors for cylindrical ionization chambers for kV X-rays were determined by Monte Carlo calculation and measurement. In this study, the X-rays of 60-300 kV beam (lSO-4037) installed in KFDA and specified in energy spectra and beam qualities, and the chambers of PTW N23333 and N30001 were investigated. In calculations, the $R_{\mu}\;and\;R_{Q,Q_{0}}$ in IAEA dosimetry protocols were determined from the air kerma and the cavity dose obtained by theoretical and Monte Carlo calculations. It is shown that the N30001 chamber has a flat response of $\pm1.7\%$ in $110\~300kV$ region, while the response range of two chambers were shown to $\pm3\~4\%$ in $80\~250kV$ region. From this work we have discussed dosimetry protocol for the kV X-rays and we have found that the estimation of energy dependency is more important to apply dosimetry protocol for kV X-rays.

  • PDF

Further Modifications to the Mobile Nylon Bag Technique to Determine Nutrient Digestibility for Swine

  • Thacker, P.A.;Qiao, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.8
    • /
    • pp.1149-1156
    • /
    • 2001
  • Previous studies conducted with swine have reported that the mobile nylon bag technique (MNBT) does not always accurately predict in vivo nutrient digestibilities. Therefore, in this study, the MNBT was modified so that nutrient digestibilities would more closely resemble those from conventional (Con) digestibility studies obtained using the indicator method. A total of 19 feeds were tested including five cereal grains, five legumes, three high protein sources and six mixed diets. The principle changes to the MNBT included the use of a fecal collection harness which minimized the number of bags lost. In addition, previous protocols involved pooling of bags within pig while in the present experiment all bags were analyzed separately to increase the precision of the test. Finally, chemical analyses were done using the entire nylon bag plus residue rather than opening.the bags and scraping out the contents. With the exception of the barley sample (p=0.01), dry matter digestibility (DMD) coefficients obtained with the MNBT were not significantly different from those obtained with the indicator method. The linear regression equation relating the MNBT to the indicator method was Con DMD=-O.77+1.02 MNBT DMD ($r^2=0.93$: p<0.0001). There was no significant (p>0.05) difference in gross energy digestibility (GED) coefficients determined using the MNBT or the indicator method for any of the 19 feeds. The regression line equation relating the MNBT to the indicator method was Con GED=-5.68+1.06 MNBT GED ($r^2=0.94$: p<0.0001). The MNBT was less effective in predicting in vivo crude protein digestibility (CPD) than it was in predicting dry matter and energy digestibility. Differences greater than five percentage units were observed for two of the legumes, Kabuli chickpeas (p=0.02) and the extruded pea-canola seed mixture (p=0.01) as well as for three of the mixed diets including the unheated hulled barley-based diet (p=0.01), the unheated hulless-barley based diet (p=0.08) and the barley-soybean meal based diet (p=0.008). The regression equation relating the MNBT to the indicator method was Con CPD=5.75 + 0.90 MNBT CPO ($r^2=0.76$; p<0.0001). This study indicates that the modified MNBT can be used for the rapid determination of dry matter and energy digestibility in a wide variety of ingredients. For the measurement of crude protein digestibility, the technique produces results similar to conventional digestibility studies for cereal grains and high protein feeds but tends to overestimate protein digestibility for legumes and mixed diets.

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

Implementation of RTP/RTCP for Teleconferencing System and Analysis of Quality-of-Service using Audio Data Transmission (영상회의 시스템을 위한 RTP/RTCP 구현 및 오디오 데이터 전송을 위용한 QoS 분석)

  • Kang, Min-Gyu;Hwang, Seung-Koo;Kim, Dong-Kyoo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.12
    • /
    • pp.3047-3062
    • /
    • 1998
  • This paper deseribes the desihn and the implementation of the Realtime Transport Protocol(RTP)/ Rdaltime Control Protocol(RTCP) (RFC 1889,1890) that is used to transmit the audio/video data to any destination and to feedback the Quality of Service (QoS) information of the received media data to the sender, in the teleconferencing systems proposed by ITU-T. These protocols are implemented with multi thead technique and run on top of UDP/IP-Multicast through the socket interface as the underlying protocol. The upper layer is impelmented such that in can be accessed by the H245 comference control protocol. The RTP packetizes the digitized audio/video data from the encoder info a fixed format, and multieast to the participants. The RTCP monitors RTP packets and extracts the QoS values from it such as round-trip delay, jiter and packet loss to form RTCP packets and non periokically sends them to the sender site. In this Paper, we also descritx the study of measurement and analysis for QoS factors that observed on performing teleconferencing system over Internet. The results from this experiment is indicate that RTT and Jitter value are acceptable even entwork load is high. However, it appears that packet loss rate is high in daytime and most losses periods have length one or two.

  • PDF

Performance Evaluation of Traffic Adaptive Sleep based MAC in Clustered Wireless Sensor Networks (클러스터 기반 무선 센서 망에서 트래픽 적응적 수면시간 기반 MAC 프로토콜 성능 분석)

  • Xiong, Hongyu;So, Won-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.5
    • /
    • pp.107-116
    • /
    • 2011
  • In this paper, a traffic adaptive sleep based medium access control (TAS-MAC) protocol for wireless sensor networks (WSNs) is proposed. The protocol aims for WSNs which consist of clustered sensor nodes and is based on TDMA-like schema. It is a typical schedule based mechanism which is adopted in previous protocols such as LEACH and Bit-Map Assisted MAC. The proposed MAC, however, considers unexpected long silent period in which sensor nodes have no data input and events do not happen in monitoring environment. With the simple traffic measurement, the TAS-MAC eliminates scheduling phases consuming energy in previous centralized approaches. A frame structure of the protocol includes three periods, investigation (I), transmission (T), and sleep-period (S). Through the I-period, TAS-MAC aggregates current traffic information from each end node and dynamically decide the length of sleep period to avoid energy waste in long silent period. In spite of the energy efficiency of this approach, the delay of data might increase. Thus, we propose an advanced version of TAS-MAC as well, each node in cluster sends one or more data packets to cluster head during the T-period of a frame. Through simulation, the performance in terms of energy consumption and transmission delay is evaluated. By comparing to BMA-MAC, the results indicate the proposed protocol is more energy efficient with tolerable expense in latency, especially in variable traffic situation.

The first KREDOS-EPR intercomparison exercise using alanine pellet dosimeter in South Korea

  • Park, Byeong Ryong;Kim, Jae Seok;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Kang, Yeong-Rok;Kim, HyoJin;Jang, Han-Ki;Han, Ki-Tek;Min, Jeho;Choi, Hoon;Kim, Jeongin;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2379-2386
    • /
    • 2020
  • This paper presents the results of the first intercomparison exercise performed by the Korea retrospective dosimetry (KREDOS) working group using electron paramagnetic resonance (EPR) spectroscopy. The intercomparison employed the alanine dosimeter, which is commonly used as the standard dosimeter in EPR methods. Four laboratories participated in the dose assessment of blind samples, and one laboratory carried out irradiation of blind samples. Two types of alanine dosimeters (Bruker and Magnettech) with different geometries were used. Both dosimeters were blindly irradiated at three dose levels (0.60, 2.70, and 8.00 Gy) and four samples per dose were distributed to the participating laboratories. Assessments of blind doses by the laboratories were performed using their own measurement protocols. One laboratory did not participate in the measurements of Magnettech alanine dosimeter samples. Intercomparison results were analyzed by calculating the relative bias, En value, and z-score. The results reported by participating laboratories were overall satisfactory for doses of 2.70 and 8.00 Gy but were considerably overestimated with a relative bias range of 10-95% for 0.60 Gy, which is lower than the minimum detectable dose (MDD) of the alanine dosimeter. After the first intercomparison, participating laboratories are working to improve their alanine-EPR dosimetry systems through continuous meetings and are preparing a second intercomparison exercise for other materials.

Analysis of Network Traffic with Urban Area Characteristics for Mobile Network Traffic Model (이동통신 네트워크 트래픽 모델을 위한 도시 지역 이동통신 트래픽 특성 분석)

  • Yoon, Young-Hyun
    • The KIPS Transactions:PartC
    • /
    • v.10C no.4
    • /
    • pp.471-478
    • /
    • 2003
  • Traditionally,, analysis, simulation and measurement have all been used to evaluate the performance of network protocols and functional entities that support mobile wireless service. Simulation methods are useful for testing the complex systems which have the very complicate interactions between components. To develop a mobile call simulator which is used to examine, validate, and predict the performance of mobile wireless call procedures must have the teletraffic model, which is to describe the mobile communication environments. Mobile teletraffic model is consists of 2 sub-models, traffic source and network traffic model. In this paper, we analyzed the network traffic data which are gathered from selected Base Stations (BSs) to define the mobile teletraffic model. We defined 4 types of cell location-Residential, Commercial, Industrial, and Afforest zone. We selected some Base Stations (BSs) which are represented cell location types in Seoul city, and gathered real data from them And then, we present the call rate per hour, cail distribution pattern per day, busy hours, loose hours, the maximum number of call, and the minimum number of calls based on defined cell location types. Those parameters are very important to test the mobile communication system´s performance and reliability and are very useful for defining the mobile network traffic model or for working the existed mobile simulation programs as input parameters.

Relief of Chronic Posterior Neck Pain Depending on the Type of Forest Therapy: Comparison of the Therapeutic Effect of Forest Bathing Alone Versus Forest Bathing With Exercise

  • Kang, Boram;Kim, Taikon;Kim, Mi Jung;Lee, Kyu Hoon;Choi, Seungyoung;Lee, Dong Hun;Kim, Hyo Ryoung;MA, Byol Jun;Park, Seen Young;Lee, Sung Jae;Park, Si-Bog
    • Annals of Rehabilitation Medicine
    • /
    • v.39 no.6
    • /
    • pp.957-963
    • /
    • 2015
  • Objective To compare the pain-reducing effect of forest bathing alone versus forest bathing in combination with stretching and strengthening exercises in patients with chronic posterior neck pain. Methods Sixty-four subjects with posterior neck pain that had lasted more than 3 months were enrolled. They were randomly divided into a forest bathing alone (FBA) group and a forest bathing with exercise (FBE) group; each group included 32 subjects. All subjects from both groups walked every morning in the forest for about 2 hours for 5 days. In the afternoon, the FBE group did a stretching and strengthening exercise for about 4 hours; the FBA group had free time in the woods. Visual analog scale (VAS) on one day, VAS over the previous week, neck disability index (NDI), EuroQol 5D-3L VAS (EQ VAS) and index (EQ index), McGill pain questionnaire (MPQ), the number of trigger points in the posterior neck region (TRPs), and the range of motion of the cervical spine were evaluated on the first and last day of the program and compared between the two groups. Results The number of TRPs were significantly reduced in the FBE group compared with the FBA group (p=0.013). However, the other scales showed no significant difference between the two groups. Conclusion When patients with chronic posterior neck pain underwent a short-term forest bathing (less than 7 days) program, FBE was more effective in the reduction of the number of TRPs than FBA. However, all other pain measurement scales we evaluated showed no statistically significant difference between the two protocols.

Implementation and Evaluation of ECG Authentication System Using Wearable Device (웨어러블 디바이스를 활용한 ECG 인증 시스템 구현 및 평가)

  • Heo, Jae-Wook;Jin, Sun-Woo;Jun, Moon-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.1-6
    • /
    • 2019
  • As mobile technologies such as Internet of Things (IoT)-based smart homes and financial technologies (FinTech) are developed, authentication by smart devices is used everywhere. As a result, presence-based biometric authentication using smart devices has become a new mainstream in knowledge-based authentication methods like the existing passwords. The electrocardiogram (ECG) is less prone to forgery, and high-level personal identification is its unique feature from among various biometric authentication methods, such as the pulse, fingerprints, the face, and the iris. Biometric authentication using an ECG is receiving a great deal of attention due to its uses in healthcare and FinTech. In this study, we implemented an ECG authentication system that allows users to easily measure and authenticate their ECG waveforms using a miniaturized wearable device, rather than a large and expensive measurement device. The implemented ECG authentication system identifies ECG features through P-Q-R-S-T feature point identification, and was user-certified under the proposed authentication protocols. Finally, assessment of measurements in a majority of adult males showed a relatively low false acceptance rate of 1.73%, and a low false rejection rate of 4.14%, in a stable normal state. In a high-activity state, the false acceptance rate was 13.72%, and the false rejection rate was 21.68%. In a high-heart rate state, the false acceptance rate was 10.48%, and the false rejection rate was 11.21%.

The Effect of Applying Various Tools to the Stiffness and Muscle Tone of Hamstring Muscles (다양한 도구의 적용이 뒤넙다리근의 뻣뻣함과 근 긴장도에 미치는 영향)

  • Hwang, Sunghyun;Kim, Taeho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.223-230
    • /
    • 2020
  • Purpose : The purpose of this study was to examine the effects of tools (i., extracorporeal shock wave therapy, massage gun, and foam roller) on range of motion, muscle tone and pain threshold among patients with hamstring stiffness. Methods : Fourteen participants with hamstrings stiffness were recruited. Interventions were performed 6 times, and each session was for 30 seconds using the three tools. The range of motion, muscle tone, and pain threshold were measured. The order of the use of the three tools was randomly determined. The foam roller was made to move from the bottom of the hip crease to the upper part of the back of the hamstring. Additionally, velocity 5 vibration stimulation was performed on the hamstring using a massage gun. Moreover, vibration stimulation was performed on the hamstring with extracorporeal shock wave therapy 5 minutes, 5 Hz, and 1,500 strokes. The flexibility of the posterior thigh muscle was based on maintaining the knee and hip joints in a 90 ° bend in the supine position. The joint angle of the knee was measured, when the knee was actively extended, at the maximum point where the posterior thigh muscle was stretched. The elasticity of the posterior thigh muscle was measured while the subject was prone and in a relaxed state without any force. Measurements were made at the muscle abdominal area of the semitendinosus muscle of the posterior femur, and the area to be measured was marked with a pen. The measurement of the tenderness threshold of the posterior femur was measured using a tenderness meter(Commander Algometer, J-Tech, USA). The force value at the point at which the pressure sensation change to pain was measured after applying vertical pressure to the posterior femur muscle, which was the halfway point between the ischial tuberosity and the popliteal surface of the subject lying on their stomach. Results : The extracorporeal shock wave therapy increased stiffness and, muscle tone, and caused changes in the pain threshold, whereas the other two tools had no effect on these indices. Conclusion : Extracorporeal shock wave therapy has important effects on range of motion and muscle stiffness and can be used in warmup protocols.