The first KREDOS-EPR intercomparison exercise using alanine pellet dosimeter in South Korea |
Park, Byeong Ryong
(National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences)
Kim, Jae Seok (National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences) Yoo, Jaeryong (National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences) Ha, Wi-Ho (National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences) Jang, Seongjae (National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences) Kang, Yeong-Rok (Research Center, Dongnam Institute of Radiological and Medical Sciences) Kim, HyoJin (Research Center, Dongnam Institute of Radiological and Medical Sciences) Jang, Han-Ki (Radiation Technology & Research Center, Korean Association for Radiation Application) Han, Ki-Tek (Radiation Technology & Research Center, Korean Association for Radiation Application) Min, Jeho (Radiation Technology & Research Center, Korean Association for Radiation Application) Choi, Hoon (Radiation Health Institute, Korea Hydro and Nuclear Power Co., Ltd.) Kim, Jeongin (Radiation Health Institute, Korea Hydro and Nuclear Power Co., Ltd.) Lee, Jungil (Radiation Safety Management Division, Korea Atomic Energy Research Institute) Kim, Hyoungtaek (Radiation Safety Management Division, Korea Atomic Energy Research Institute) Kim, Jang-Lyul (Radiation Safety Management Division, Korea Atomic Energy Research Institute) |
1 | International Organization for Standardization (ISO), Radiological Protection-Minimum Criteria for Electron Paramagnetic Resonance (EPR) Spectroscopy for Retrospective Dosimetry of Ionizingradiation - Part 1: General Principle. ISO 13304-1, 2011. |
2 | International Atomic Energy Agency (IAEA), Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies, 2011. |
3 | M. Desrosiers, D.A. Schauer, Electron paramagnetic resonance (EPR) biodosimetry, Nucl. Instrum. Methods Phys. Res. B 184 (2001) 219-228, https://doi.org/10.1016/S0168-583X(01)00614-0. DOI |
4 | C. Bassinet, F. Trompier, I. Clairland, Radiation accident dosimetry on electronic components by OSL, Health Phys. 98 (2010) 440-445. DOI |
5 | R. Grun, Electron spin resonance dating and the evolution of modern humans, Archaeometry 33 (1991) 153-199, https://doi.org/10.1111/j.1475-4754.1991.tb00696.x. DOI |
6 | Committee European de Normalisation(CEN), Detection of Irradiated Food Containing Bone, Method by ESR Spectroscopy, European Committee for Standardization EN 1786, 1996. |
7 | Committee European de Normalisation(CEN), Detection of Irradiated Food Containing Cellulose, Method by ESR Spectroscopy, European Committee for Standardization EN 1787, 2000. |
8 | Committee European de Normalisation(CEN), Detection of Irradiated Food Containing Crystalline Sugar, Method by ESR Spectroscopy, European Committee for Standardization EN 13708, 2001. |
9 | International Atomic Energy Agency (IAEA), Use of Electron Paramagnetic Resonance Dosimetry with Tooth Enamel for Retrospective Dose Assessment. IAEA-TECDOC-1331, 2002. |
10 | V.G. Skvortsov, A.I. Ivannikov, V.F. Stepanenko, A.F. Tsyb, L.G. Khamidova, A.E. Kondrashov, D.D. Tikunov, Application of EPR retrospective dosimetry for large-scale accidental situation, Appl. Radiat. Isot. 52 (2000) 1275-1282, https://doi.org/10.1016/S0969-8043(00)00083-X. DOI |
11 | N. Nakamura, C. Miyazawa, M. Akiyama, S. Sawada, A. Awa, A close correlation between electron spin resonance (ESR) dosimetry from tooth enamel and cytogenetic dosimetry from lymphocytes of Hiroshima atomic-bomb survivors, Int. J. Radiat. Biol. 73 (1988) 619-627, https://doi.org/10.1080/095530098141870. DOI |
12 | Abbas Noori, Mojtaba Mostajaboddavati, Farhood Ziaie, Retrospective dosimetry using fingernail electron paramagnetic resonance response, Nucl. Eng. Technol. 50 (2018) 526-530, https://doi.org/10.1016/j.net.2018.01.014. DOI |
13 | V. CHUMAK, et al., The first International Intercomparison of EPR-dosimetry with teeth: first results, Appl. Radiat. Isot. 47 (1996) 1281-1286, https://doi.org/10.1016/S0969-8043(96)00231-X. DOI |
14 | V. Gancheva, N.D. Yordanov, F. Callens, G. Vanhaelewyn, J. Raffi, E. Bortolin, S. Onori, E. Malinen, E. Sagstuen, S. Fabisiak, Z. Peimel-Stuglik, An international intercomparison on ''self-calibrated'' alanine EPR dosimeters, Radiat. Phys. Chem. 77 (2008) 357-364, https://doi.org/10.1016/j.radphyschem.2007.06.004. DOI |
15 | C. De Angelis, V. De Coste, P. Fattibene, S. Onori, E. Petetti, Use of alanine for dosimetry intercomparisons among Italian radiotherapy centers, Appl. Radiat. Isot. 62 (2005) 261-265, https://doi.org/10.1016/j.apradiso.2004.08.019. DOI |
16 | E. Haskell, G. Kenner, R. Hayes, S. Sholom, V. Chumak, AN EPR intercomparison using teeth irradiated prior to crushing, Radiat. Meas. 27 (1997) 419-424, https://doi.org/10.1016/S1350-4487(96)00131-X. DOI |
17 | A. Wieser, et al., The second international intercomparison on EPR tooth dosimetry, Radiat. Meas. 32 (2000) 549-557, https://doi.org/10.1016/S1350-4487(00)00060-3. DOI |
18 | A. Wieser, et al., The 3rd international intercomparison on EPR tooth dosimetry: Part 1, general analysis, Appl. Radiat. Isot. 62 (2005) 163-171, https://doi.org/10.1016/j.apradiso.2004.08.027. DOI |
19 | P. Fattibene, et al., The 4th international comparison on EPR dosimetry with tooth enamel Part 1: report on the results, Radiat. Meas. 46 (2011) 765-771, https://doi.org/10.1016/j.radmeas.2011.05.001. DOI |
20 | P. Fattibene, et al., EPR dosimetry intercomparison using smart phone touch screen glass, Radiat. Environ. Biophys. 53 (2014) 311-320, https://doi.org/10.1007/s00411-014-0533-x. DOI |
21 | V. Nagy, Accuracy consideration in EPR dosimetry, Appl. Radiat. Isot. 52 (2000) 1039-1050, https://doi.org/10.1016/S0969-8043(00)00052-X. DOI |
22 | International Organization for Standardization (ISO), Practice for Use of an Alanine-EPR Dosimetry System. ISO/ASTM 51607, 2013. |
23 | International Organization for Standardization (ISO), Conformity Assessment - General Requirements for Proficiency Testing. ISO/IEC 17043, 2010. |
24 | R.B. Hayes, E.H. Haskell, G.H. Kenner, A mathematical approach to optimal selection of dose values in the additive dose method of EPR dosimetry, Radiat. Meas. 27 (1997) 315-323, https://doi.org/10.1016/S1350-4487(96)00117-5. DOI |
![]() |