• 제목/요약/키워드: Measurement Noise

Search Result 3,212, Processing Time 0.032 seconds

Analysis of Channel Noise and Impedance Characteristics for High-Speed Power-Line Communication (고속 전력선 통신을 위한 전력선채널 잡음 및 임피던스 특성 분석)

  • 김정훈;김선효;김상태;이영철;신철재
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.37-40
    • /
    • 2001
  • Subject of this paper is analysis of channel noise and impedance characteristics for high speed power line communication to concerned noise of transmission line and impedance in the frequency range up to 30MHz. Parameters of transmission line was inducted from experimentally power line channel measurement. Moreover, Analysis of compared based on measurement of channel characters with simulation test for appear characters.

  • PDF

Luminance measurement at low levels for detecting Mura

  • Jensen, Jens Joergen;Stentebjerg, Rene Bolvig;Frausing, Jack
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.991-994
    • /
    • 2009
  • This paper reports of camera detection of Mura. The type, location, size, orientation and amplitude are found. As the luminance variation in Mura is down to less than app. 0.3 %, measurement apparatus, techniques and algorithms are developed to measure low noise data and to extract the Mura from data with the residual noise in the same magnitude as the Mura.

  • PDF

MLS for Building Acoustics Measurement (건축음향을 위한 MLS 측정방법)

  • Borjabad, Roberto
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.386-393
    • /
    • 1996
  • The paper describes how a Maximum Length Sequence(MLS) and correlation technique in the form of Hadamard transformation may be applied for the measurement of airborne sound reduction. It is shown that in most cases, the values obtained by the MLS technique will be equal to the expected values obtained by the classical method. However, due to the correlation process involved, the MLS method will be much less sensitive to disturbances from extraneous noise. The described method has been implemented in an RTA acoustic analyser.

  • PDF

The Selection of Measurement Positions for BEM Based NAH Using a Non-conformal Hologram to Reduce the Reconstruction Error

  • Oey, Agustinus;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1018-1021
    • /
    • 2007
  • This paper explores the use of BEM based NAH to reconstruct the surface vibration of a plate in a rectangular finite cavity, in which the distances between sensors and the nearest points on the source surface are not equal. In such circumstances, different degree of information on propagating and non-propagating wave components will be detected by sensors at different positions, as well as the influence of measurement noise will vary significantly from the nearest points of measurement to the farthest ones. On the other hand, the condition number of the vibro-acoustic transfer function matrix relating normal surface velocities and field pressures will becomes high, numerically indicating an increase of linear dependency between rows of transfer function matrix. The combination of poor measurement and high condition number will result inaccurate reconstruction. Therefore, one approach to be investigated in this work is to select the measurement positions in such ways that reduce measurement redundancy, as it indicated by the condition number. The improvement is found to be significant in the numerical simulations utilizing two different criterions, spanning from over-determined to under-determined cases, and in the validation experiment.

  • PDF

A Study on the Measurement of Small Partial Discharges in a Low-voltage Induction Motor (저압 유도전동기에서 미소 부분방전 측정에 관한 연구)

  • Kil, Gyung-Suk;Song, Jae-Yong;Seo, Hwang-Dong;Hwang, Don-Ha;Kang, Dong-Sik;Kim, Yong-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.10
    • /
    • pp.960-964
    • /
    • 2005
  • In this paper, we dealt with a partial discharge(PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage electric and electronic devices. The PD measurement system Is composed of a coupling network, a low noise amplifier, and associated electronics. h shielded box Is adopted to make a better measurement environment against around noise. A low cut-off frequency of the coupling network estimated by a sinusoidal wave input was 125 kHz (-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 10 mV/pC. In an application test oil a low-voltage three phase Induction motor (5 HP), we could detect 0.53 pC level of partial discharge at the applied voltage of AC 650 $V_{peak}$.

An Advanced Phase Angle Measurement Algorithm And Error Analysis (개선된 위상 측정 알고리즘과 오차 해석)

  • 송영석;김재철;최인규;박종식
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.3
    • /
    • pp.25-32
    • /
    • 2004
  • An advanced algorithm for measurement of phase angle between two sinusoidal signals is proposed in this paper. This algorithm uses discrete sample data of two input signals for calculation of phase angle and amplitude. And the key parameters of the measurement algorithm are described by analytical express, so the calculation of phase angle is simplified. In this paper it is proved that harmonic distortion of the input sinusoidal signals does not affect the measurement value of phase angle by using the proposed algorithm when a whole cycle is sampled. And measurement error by the white Gaussian noise is very small compared by other algorithms.

Analysis of Measurement Accuracy Based on Confidences for Narrow-Band Underwater Acoustic Measurement (협대역 수중음향측정을 위한 신뢰도 기반의 측정정확도 분석)

  • 도경철;최재용;이용곤
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.16-22
    • /
    • 2000
  • In order to predict the performance and the usefulness of the narrow-band underwater acoustic measurement system at design stage, whose error variance is not clearly described, in this study a boundary equation to estimate the measurement accuracy is proposed based on the confidency as SNR variation. The boundary is presented as a function of SNR and the number of samples. In this paper, the measurement performance for narrow-band signal is simulated by the proposed boundary equation and the results are reviewed in the biased noise condition and separately in the background noise rejected condition.

  • PDF

Acquisition Model for 3D Shape Measurement Data

  • Park, Jong-Sik;Jang, Wang-Jin;Lee, Seong-Beom;Park, Chan-Seok
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.16-21
    • /
    • 2008
  • The demand for three-dimensional (3D) shape measurements is increasing in a variety of fields, including the manufacture of molds and dies. The most popular technology for 3D shape measurement is the coordinate measuring machine (CMM) with a contact trigger probe. Although a CMM provides a high degree of accuracy, it is inefficient due to its long measuring time. It also has difficulty measuring soft objects that can be deformed by the touch of the contact probe. In addition, a CMM cannot digitize areas that are difficult to reach, and cannot capture very minute details on the surface of complex parts. For these reasons, optical non-contact measurement techniques are receiving more attention since they eliminate most of the problems associated with contact methods. Laser scanning is emerging as one of the more promising non-contact measurement techniques. This paper describes various acquisition considerations for laser scanning, including the accuracy of the 3D scan data, which depends on the charge-coupled device (CCD) gain and noise. The CCD gain and noise of a 3D laser scanner are varied while keeping the other conditions constant, and the measurement results are compared to the dimensions of a standard model. The experimental results show that a considerable time savings and an optimum degree of accuracy are possible by selecting the proper CCD gain and noise.

Translation-invariant Wavelet Denoising Method Based on a New Thresholding Function for Underwater Acoustic Measurement (수중 음향 측정을 위한 새로운 임계치 함수에 의한 TI 웨이블렛 잡음제거 기법)

  • Choi, Jae-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1149-1157
    • /
    • 2006
  • Donoho et al. suggested a wavelet thresholding denoising method based on discrete wavelet transform. This paper proposes an improved denoising method using a new thresholding function based on translation-invariant wavelet for underwater acoustic measurement. The conventional wavelet thresholding denoising method causes Pseudo-Gibbs phenomena near singularities due to the lack of translation-invariant of the wavelet basis. To suppress Pseudo-Gibbs phenomena, a denoising method combining a new thresholding function based on the translation-invariant wavelet transform is proposed in this paper. The new thresholding function is a modified hard-thresholding to each node according to the discriminated threshold so as to reject unknown external noise and white gaussian noise. The experimental results show that the proposed method can effectively eliminate noise, extract characteristic information of radiated noise signals.

A Study of Response Characteristics for the Interior Impulse Noise based on Interpreted Models (해석 모델 기반의 실내 충격소음 응답특성에 관한 연구)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.22-28
    • /
    • 2014
  • This study is compare to model-based analysis and experimental data of the response characteristic of interior impulse noise. Interior impulse noise and the pressure response characteristics of the building structure on its analysis are presented the impulse pressure acting on the rear wall 90 N-sec. The force acting on the wall $CFD^{{+}{+}}$ which are compared measurement and simulation analysis. Results of simulation and measurement data were shown. In this study, a high dimension of the degree of virtual space in the numerical space of the lesser degree in order to calculate folding method was applied. The results of this study contribute safety evaluation and model development for the interior impulse noise that affects the basic data for the interior impulse noise model validate for the physical quantity prediction.