• 제목/요약/키워드: Measurement Method of Interval Length

검색결과 21건 처리시간 0.024초

He-Ne 레이저의 간섭을 이용한 고정밀 리니어 스케일의 제작에 관한 연구 (A Study on the Manufacturing of High Precision Linear Scale Using He-Ne Laser Interference)

  • 한응교;전병욱;이명호;박두원;노병옥
    • 한국정밀공학회지
    • /
    • 제8권3호
    • /
    • pp.82-92
    • /
    • 1991
  • A study on the manufacturing of High Precision Linear Scalr using He-Ne Laser interference Of late, along with the advancement of precision machining technology, the requirement of super precision measurement increases as time goes on, and the accuracy of standard scale which is a basis of precision measurement has been cognized as a criterion of industrial development in a nationl. In this paper, we described on technology by which we could carve scale lines thru optical method under the condition of laboratory by using the coherence of He-Ne two-mode stabilized laser and in turn, put it to practical use as linear scale for the measurement of length. Hence in this research in the case of setting scale interval to 20 ${\mu}m$, we employed super precision scale-carving device associated with Ar laser and acousto optic modulator in lieu of flashing lamp scale-carving device, and we obtained as experimental result superior linear scales carved within the accuracy of ${\pm}$0.3${\mu}m$.

  • PDF

영상처리를 이용한 공간 교통정보 측정 (Measurement of Spatial Traffic Information by Image Processing)

  • 권영탁;소영성
    • 융합신호처리학회논문지
    • /
    • 제2권2호
    • /
    • pp.28-38
    • /
    • 2001
  • 교통정보는 크게 지점정보와 공간정보로 나눌 수 있다. 지점정보는 한 지점에서의 차량의 유무 판정을 통해 얻을 수 있는 정보이며, 공간정보는 일정 공간을 관찰해야만 얻을 수 있는 고급 교통정보이다. 영상처리를 이용해 공간정보를 측정하기 위해서는 차량의 전역 추적을 필요로 하는데 전역 추적에 기반한 영상검지기는 비디오 입력, 차량 탐지, 차량 추적, 교통정보 측정의 네 부분으로 나눌 수 있다. 기존의 연구들은 비디오 입력시 자동 아이리스를 사용하여 급격한 밝기변화에 대응치 못하는 단점이 있고 차량 탐지시 기존의 배경생성 방법들은 정체가 심한 교차로에서 매우 좋지 않은 결과를 보인다. 또한 대부분의 연구에서 교통정보 측정을 지점 정보로만 국한하였다. 본 연구에서는 자동 아이리스의 단점 개선을 위해 사용자 제어 아이리스 방법을 제안하였고, 복잡한 교차로에서도 배경생성을 견고히 할 수 있는 장면차이 기반 배경생성 방법을 제안하였다. 또한 통행량/시간/속도는 물론 대기행렬 길이, 회전/직진 교통류의 공간 교통정보를 측정하는 방법을 제안하였고 실제 실험을 해 본 결과 95%∼100%의 정확도를 보였다.

  • PDF

자력검층을 이용한 파일 심도 예측 (Pile Depth Prediction by Magnetic Logging)

  • 김진후
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.231-236
    • /
    • 2000
  • In order to predict depth of the pile forward modeling and inversion of magnetic logging data was conducted by using a finite line of dipoles model. The horizontal component as well as the vertical component of magnetic fields can be measured in the borehole, and the magnetic anomalies can be obtained by subtracting the Earth's magnetic field from the measurement. The magnetic anomalies of the pile are considered as vector sum of induced magnetization due to the Earth's magnetic field and remnant magnetization possessed by steel strings in the pile. The magnetic anomalies are used as input data for inversion from which the length, the magnetic moment per unit length, and the dip angle of the pile can be obtained. From the inversion of synthetic noisy data, and the data obtained from the field model test it is found that the driving depth of the pile can be determined as close to the order of measuring interval (5∼10㎝). It is also found that the resultant magnetic anomalies due to an individual steel string in the pile are almost same as those due to a group of steel strings located at the center of the pile. The magnetic logging method also can be used for locating reinforced bars, pipes, and steel casings.

  • PDF

시간 측정범위 향상을 위한 펄스 트레인 입력 방식의 field-programmable gate array 기반 시간-디지털 변환기 (Field-Programmable Gate Array-based Time-to-Digital Converter using Pulse-train Input Method for Large Dynamic Range)

  • 김도형;임한상
    • 전자공학회논문지
    • /
    • 제52권6호
    • /
    • pp.137-143
    • /
    • 2015
  • Field-programmable gate array (FPGA) 기반 시간-디지털 변환기 (time-to-digital converter: TDC)는 구조가 단순하고, 빠른 변환속도를 갖는 딜레이 라인 (delay-line) 방식을 주로 사용한다. 하지만 딜레이 라인 방식 TDC의 시간 측정범위를 늘리기 위해서는 딜레이 라인의 길이가 길어지므로 사용되는 소자가 많아지고, 비선형성으로 인한 오차가 증가하는 단점이 있다. 따라서 본 논문은 동일한 길이의 딜레이 라인에 펄스 트레인 (pulse-train)을 입력하여 시간 측정범위를 향상시키고, 리소스를 효율적으로 사용하는 방식을 제안한다. 펄스 트레인 입력 방식의 TDC는 긴 시간을 측정하기 위하여 시작신호의 입력과 동시에 4-천이 (transition) 펄스 트레인이 딜레이 라인에 입력된다. 그리고 동기회로 (synchronizer) 대신 천이 상태 검출부를 설계하여 중지신호 입력 시 사용된 천이를 판별하고, 준안정 상태 (meta-stable state)를 피하면서 딜레이 라인의 길이를 줄이는 구조를 갖는다. 제안한 TDC는 72개의 딜레이 셀 (delay cell)을 사용하였고, 파인부 (fine interpolator)의 성능 측정 결과, 시간 측정범위는 5070 ps, 평균 분해능은 20.53 ps, 최대 비선형성은 1.46 LSB였으며, 시간 측정범위는 계단 (step) 파형을 입력신호로 사용하는 기존 방식 대비 약 343 % 향상되었다.

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • 제21권6호
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

전화를 이용한 퇴원환자 만족도 조사 (The Measurement Of Postdischarge Patient Satisfaction Using Telephone Interview)

  • 송정흡
    • 한국의료질향상학회지
    • /
    • 제4권1호
    • /
    • pp.104-114
    • /
    • 1997
  • Background : Hospitals(Health care providers) are under tremendous pressure to meet consumer demands in order to compete in the rapidly changing health care arena. Through evaluating patient satisfaction, hospitals(health care providers) can learn what the consumer Wants from the health care system. Timely feedback is necessary. The purpose of this study is to evaluate patients' hospital experience and satisfaction using telephone interview and to study the usefulness for telephone interview at assessing patient satisfaction. Method : The 846 patients who were discharged from September 17, 1996 to October 11, 1996 were targeted were telephoned. The informations gathered telephone survey were processed by computer and analyzed for the patient satisfaction, contributing factors. Result : The 846 patients who were discharged from September 17, 1996 to October 11, 1996 were called and 197 patients(23.3%) were successful interviewed. 51.3 percent of respondents were male and mean age is 39 years mean LOS(length of stay) is 13 days and 110(56.1%) patients were admitted by outpatients clinic. The mean calling-time is 5.5 minutes. There is no significant difference between interviewers(telemarketer) in patients satisfaction. Seven telephone interviews are possible by interview a day. There in no significant difference between groups in patients satisfaction in length of stay, path of admission, the interval between discharge and interview. 97.5 percent of respondents were satisfied with telephone interview and 81.7% were satisfied with overall satisfaction and 79.4 % of respondents were good response in interviewers' conclusion. Of six variables that were found to be correlated with telephone interview and eight variables correlated with overall hospital satisfaction, a multiple logistic regression analysis revealed that two most important variables which are significantly correlated with telephone interview are to meet doctors, not ask tediously then three variables which are with overall satisfaction are doctors explain, subject response, convenient facilities. Conclusion : The patients interviewed are satisfied with telephone interview. Telephone interview is good method for assessing patient satisfaction, making high levels of patient satisfaction and for hospital marketing.

  • PDF

3차원 음향홀로그래픽을 이용한 음원위치 추정에 관한 연구 (A Study Absolute Position Estimation of Sound Source)

  • 김천덕;심동연;장비;이채봉;차경환
    • 한국음향학회지
    • /
    • 제16권5호
    • /
    • pp.76-82
    • /
    • 1997
  • 본 논문은 음원의 절대위치를 정확하게 추정할 수 있는 음향홀로그래픽법에 관하여 계산기상의 시뮬레이션 및 측정시스템을 이용한 실험과결과에 대하여 서술한다. 이 연구에서는 원거리 음장을 만족하도록 측정면을 설정하여 7개의 마이크로폰을 직선으로 배열한다. 음원의 측정은 음원면에 근접한 위치에 한 개의 기준 마이크로폰을 설치하고 측정면의 마이크로폰들을 등간격으로 스캐닝하면서 각지점의 음을 동시 기록한다. 수음한 기준음과 측정음간의 크로스 스펙트럼 알고리즘에 의하여 음원의 절대위치를 측정한다. 그리고 각 마이크로폰의 위상차는 기준 마이크로폰을 대상으로 위상보상 하였으며, 측정시의 시간지연은 제 1열 측정시점을 기준으로 시간보상을 행하였다. 측정면에 설정한 마이크로폰들의 최적 간격은 수치 시뮬레이션에 의하여 정한다. 음원신호는 정현파를 이용하고 S/N비를 30dB의 조건하에서 각각 실험을 행하였다. 시뮬레이션과 실험에서 결정한 최적 마이크로폰 간격은 2KHz인 정현파 음원을 기준으로 하여 공간상의 나이키스트 조건을 만족하도록 설정하였다. 무향실에서 측정한 실험결고, 500Hz 와 1KHz의 신호원에 대한 음원이 2KHz인 경우의 추정된 3차원 홀로그램의 주극폭이 각각 87%와 30%씩 감소하였고, 그 결과 수치 시뮬레이션의 타당성을 확인할 수 있었다. 그러므로 본 연구에서 제안하는 3차원 음향 홀로그래픽법을 이용한 음원위치 추정에 관한 연구의 유용성을 검증하였다.

  • PDF

치근형 골내 임플란트의 초기 1년간 치조골 소실 및 골 밀도 변화에 관한 연구 (ALVEOLAR BONE LOSS & BONE DENSITY CHANCES DURING THE FIRST YEAR A COMPARATIVE STUDY ON FOUR TYPES OF ROOT-FORM ENDOSSEOUS DENTAL IMPLANT SYSTEMS)

  • 정영철;한종현;이근우
    • 대한치과보철학회지
    • /
    • 제32권3호
    • /
    • pp.455-469
    • /
    • 1994
  • Regular radiographic examination has been considered an essential diagnositic method for osseointegrated dental implantation. This study investigated marginal bone loss through the measurement on periapical radiographs and changes in bone density through digital subtraction image radiographic method around 88 endoseous root-form dental implants in 43 human subjects. Four types of endosseous dental implants were investigated : Standard series, Mini series and Hex-lock system of Steri-Oss Dental implant system, and $Br{\aa}nemark$-type implant from 3i dental implant system, in a 3 month interval for a total period of 12 months. The results were as follows : 1. Rapid bone loss occurred in the first 3 months in all 4 groups, and the bone level stabilized at the first thread of the implant fixtures. Amount of bone loss for 12 months showed correlation with the length of the polished neck portion. 2. Most of the implant systems showed resorption of alveolar bone up to the polished neck portion although a long polished neck could delay the resolution. 3. Alveolar bone loss apical to the polished neck portion stabilized at the first thread of the fixtures with no correlation to either the time of exposure of the polished neck or types of implant systems. 4. No changes in bone density around the implant threads were observed throughout the experimental period. Bone density decreased at the marginal bone, and increased at the newly-formed alveolar crest. These results indicate that most of the alveolar bone loss occur within the first 12 months after installation of endosseous root-form dental implants resulting in the exposure of polished neck portions, and the bone level stabilizes thereafter at the first thread portions of the implant fixtures. The experimental period of 12 months seems insufficient for observing changes in bone density, and a long-term observation should be needed.

  • PDF

고속철도차량의 공력소음 측정 시험법 개발 (Development of aerodynamic noise measurement method for high-speed trains)

  • 정민승;김재환;장형석;김종환;정철웅;이권기
    • 한국음향학회지
    • /
    • 제43권1호
    • /
    • pp.131-137
    • /
    • 2024
  • 고속으로 주행하는 열차의 주변 유동에 의해 발생하는 공력소음은 실외소음과 실내소음에 모두 영향을 미친다. 본 연구는 열차표면의 압력섭동데이터를 통해 공력소음을 측정하고 실내소음에 영향을 미치는 성분을 정량적으로 평가하기 위한 시험법을 개발하고 분석하는 것이다. 실내소음을 정확히 평가하기 위해서는 취득한 표면 압력섭동 데이터에서 혼재되어 있는 압축성 압력섭동과 비압축성 압력섭동을 각각 분리하여 평가하는 것이 중요하다. 이는 두 압력섭동의 소음 전달 특성이 다르기 때문이다. 먼저 마이크로폰의 설치 길이와 간격을 결정하여 표면 압력섭동 데이터를 취득하였고, 파수-주파수 분석을 수행하여 비압축성 압력섭동과 압축성 압력섭동을 분리하여 음압 스펙트럼을 취득하였다. 마지막으로 전두부와 후두부에서 측정한 시험 결과값을 비교한 결과 전두부 표면 압력섭동이 후두부 압력섭동보다 더 큼을 확인하였다.

가상기지국을 활용한 지적기준점 관측 정확도 분석 -진주시 일원을 중심으로- (Accuracy Analysis of Cadastral Control Points Surveying using VRS case by Jinju city parts)

  • 최현;김규철
    • 한국측량학회지
    • /
    • 제30권4호
    • /
    • pp.413-422
    • /
    • 2012
  • 1960년대 GPS가 개발되어 2000년도 미국에서 SA(Selective Availability)를 해제함에 따라 본격적인 상용화가 시작되며 현재에 이르렀다. 개발을 거듭해온 GPS의 관측 방식 중 실시간 이동측량방식은 항상 2대의 수신기가 필요하며 기준국과 이동국의 거리가 멀어짐에 따라 정확도가 떨어지는 문제점이 발생한다. 이러한 개선방안으로 가상기지국 방식이 도입되었다. 가상기지국은 여러 개의 GPS상의 관측소 자료로부터 이동국 인근에 가상점을 생성시켜 이동국의 정밀한 위치를 결정하는 방식이므로 신뢰성과 이동성이 높다. 또한 현재의 지적기준점은 방위각법, 배각법, 다각망도선법 등의 방법으로 관측하여 사용하고 있으며, 측량성과가 서로 다른 기지점의 성과차, 도선의 길이에 대한 제약, 관측시의 여러 오차들로 인하여 문제점들이 많이 발생하고 있다. 따라서 본 연구에서는 상시관측소 데이터를 이용하여 지적기준점에 대하여 가상기지국 방식을 통한 데이터를 비교 분석하였다. 관측결과, 지적기준점을 관측한 토털스테이션을 사용하여 배각법으로 관측한 성과와 VRS-RTK로 관측한 성과를 비교한 결과 X축 평균오차 -0.08m, Y축 평균오차 +0.07m, 평균거리오차 0.11m로 나타났다.