• Title/Summary/Keyword: Measurement Error Factors

Search Result 242, Processing Time 0.028 seconds

A Study on Measurement Error Factors of Theodolite System (데오도라이트 시스템의 측정 오차 요인에 관한 연구)

  • 박홍철;윤용식;최석원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.272-275
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is 0.5 mm or better for distance 0 ~ 100 m. And the system is used for the measurement of a product for middle and large scale. This study was performed for finding the measurement error factors of the system. We could know that the main error factors are temperature, illumination and expertness. And we could find the measurement errors are $\pm$ 0.045 mm at temperature conditions is 2$0^{\circ}C$ and $\pm$ 0.012 mm at illumination condition is 300 lux. Also the results had significant differences by combinations of operator's expertness.

  • PDF

A Study on Measurement Error Factors of Theodolite System (데오도라이트 시스템의 측정 오차 요인에 대한 연구)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.4
    • /
    • pp.36-42
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is ${\pm}0.5mm$or better for distance 0~100m. And the system is used for the measurement of a product of middle and large scale. This study is performed for the measurement error factors of the system. We could know that the main measurement error factors are temperature, illumination and skill. Also, we performed the study for the effect according to the height difference of scale bar.

Analysis of power line phasor measurement error (Power line phasor 측정 오차 해석 연구)

  • Kim, Byoung-Il;Chang, Tae-Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.367-368
    • /
    • 2006
  • This paper presents an analytic derivation of phase measurement error. The analysis derives the measurement error caused by the finite-bit quantization of both input signals and twiddle factors used in the recursive implementation of the phasor measurement algorithm. The derivation is based on the statistical exploration of the error dynamic equations. The effect of frequency deviation and the number of DFT points are also included in the study. The analysis results are verified with the data obtained from the computer simulation by widely varying the values of error causing factors.

  • PDF

Considerations for error factors in four measurement systems determined in JEITA standard ED2523 (Measuring methods for matrix reflective LCD modules)

  • Narutaki, Yozo;Sakai, Eiji;Shimizu, Shinji;Tsuda, Keisuke;Uehara, Masao;Uehara, Toshinori;Katoh, Shinsuke;Yoda, Yuji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1362-1365
    • /
    • 2008
  • ED-2523 (Measuring methods for matr ix reflective LCD modules) was published by JEITA (Japan Electronics and Information Technology Industries Association) in 2001. Since then, round robin tests had been done and the accuracy of measurement values had been discussed. In this paper, considerations for error factors in four measurement systems are showed.

  • PDF

The enhancement of 3-dimensional positioning accuracy by measuring error factors for CNC machine tools (공작기계의 오차요소 측정을 통한 3차원 위치정밀도 향상)

  • 손진욱;서석환;정세용;이응석;위현곤
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.260-265
    • /
    • 1994
  • Efforts have been devoted to developing rapid and accurate methods for measuring the errors of machine tools. The method os measurement and calibration of machine tool errors should be general and efficient. The objective of this study is to show in detail the full sequence from the measurement of errors factors to the verification of the positioning accuracy after compensation for the volumetric error. In this paper, we described the steps in measuring the volumetric error parameters, a general error model composed of error parameters, temperature, and the desired position. The validity of the error calibration methods proposed in this paper was tested using a vertical 3-axis CNC machine with a laser interferometer and a ball bar.

  • PDF

Disturbance Observer-based Current Measurement Offset Error Compensation in Vector-controlled SPMSM Drives (표면 부착형 동기 전동기 벡터 제어에서의 외란 관측기 기반 전류 측정 오프셋 오차 보상 방법)

  • Lee, Sang-Min;Lee, Kibok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.402-409
    • /
    • 2022
  • In vector-controlled drive systems, the current measurement offset error causes unwanted torque ripple, resulting in speed and torque control performance degradation. The current measurement offset error is caused by various factors, including thermal drift. This study proposes a simple DC offset error compensation method for a surface permanent magnet motor based on a disturbance observer. The disturbance observer is designed in the stationary reference frame. The proposed method uses only the measured current and machine parameters without additional hardware. The effect of parameter variations is analyzed, and the performance of the current measurement offset error compensation method is validated using simulation and experimental results.

A Review on the Job Stress Measurements in Nuclear Power Plant Workers for Human Error Prevention

  • Kim, Seon Soo;Luo, Meiling;Oh, Yeon Ju;Lee, Yong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.47-58
    • /
    • 2013
  • Objective: The aim of this study is to review the job stress measurement for applying in nuclear power plants(NPPs). Background: The standard and guideline to evaluate and manage the job stress is insufficient in NPPs. Although job stress might have a negative effect on task performance particularly it can be related with human error in NPPs. Method/Results: This paper considered the objective and subjective stress measurements. One of the questionnaire(Korean Occupational Stress Scale) and the experiment method was investigated to apply in NPPs. KOSS was analyzed about the inter item consistency and correlation with the workload, and relative importance. In the objective evaluation considered the experiment method for the physical and mental job stress and analyzed from the phased point of view. Conclusion/Application: The measurement and criteria to evaluate job stress for operators must be complemented on the job characters and environments in NPPs. This study may support to confirm and manage the job stress in NPPs. The study of more specific methodology on job stress in NPPs is required on the basis of this paper.

Multivariable Bayesian curve-fitting under functional measurement error model

  • Hwang, Jinseub;Kim, Dal Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.6
    • /
    • pp.1645-1651
    • /
    • 2016
  • A lot of data, particularly in the medical field, contain variables that have a measurement error such as blood pressure and body mass index. On the other hand, recently smoothing methods are often used to solve a complex scientific problem. In this paper, we study a Bayesian curve-fitting under functional measurement error model. Especially, we extend our previous model by incorporating covariates free of measurement error. In this paper, we consider penalized splines for non-linear pattern. We employ a hierarchical Bayesian framework based on Markov Chain Monte Carlo methodology for fitting the model and estimating parameters. For application we use the data from the fifth wave (2012) of the Korea National Health and Nutrition Examination Survey data, a national population-based data. To examine the convergence of MCMC sampling, potential scale reduction factors are used and we also confirm a model selection criteria to check the performance.

Development of Computer Aided Measurement and Compensation System for Linear Pitch Error Correction in CNC Machine Tools Implementing a New Optimal Correction Algorithm (CNC 공작기계 선형피치오차의 최적 보정알고리즘을 구현하는 자동 측정 및 보정 시스템의 개발)

  • 이석원;박희재;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.69-77
    • /
    • 1998
  • Linear displacement accuracy is one of the most important factors that determine machine tool accuracy The laser interferometer has been usually recommended for the measurement of linear displacement accuracy. In this paper, microcomputer aided measurement and compensation system has been developed for the pitch error in a CNC machine tool. For accurate pitch error calculation. the analysis code for the pitch error has been also implemented according to the international standards (ISO). The PC based automatic compensation system for the pitch error is also implemented. A new algorithm for calculating optimum value for pitch error compensation is proposed, minimizing the deviation at each target points. The development system has been applied to a practical CNC maching center and the performance has been demonstrated.

  • PDF

Geometric Error Analysis of Contact Type Three Points Supporting Method for Inner Diameter Measurement (접촉식 3점지지법에 의한 내경측정의 기하학적 오차 해석)

  • Kim, Min-Ho;Kim, Tae-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.5
    • /
    • pp.69-76
    • /
    • 2008
  • Inner diameter of bearing race is automatically measured by complete inspection system after grinding process. Contact type three points supporting method is widely applied to automatic inner diameter measurement because of its excellent stability. However, the geometric consideration regarding three points supporting method is not sufficient. In this study, the error equation from geometric error analysis of three points supporting method is found. The effect of factors in the error equation is also investigated. The error equation is linear for difference of diameter in sample and master on range of tolerance. An error becomes more and more larger, when the distance of two supporting balls or the diameter of supporting ball are increased. In the result, some considerations are proposed for measurement of inner diameter by the three points supporting method.