THE POSITIONAL RELATIONSHIP BETWEEN THE MANDIBLE AND THE HYOID BONE IN MANDIBULAR PROTRUSION AFTER ORTHOGNATHIC SURGERY EVALUATED WITH 3-D CT (3-D CT를 이용한 악교정술 전후의 하악과 설골의 위치에 관한 연구)

  • Lee, Sang-Han;Nam, Jeong-Hun;Jung, Chang-Wook;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.3
    • /
    • pp.173-181
    • /
    • 2003
  • Purpose : This study was intended to evaluate the positional relationship between the hyoid bone and the mandible in patients with mandibular protrusion after mandibular set-back surgery by means of 3D-CT. Materials and methods : Preoperative(3 weeks before) and postoperative (6 weeks after) 3D-CT & cephalogram were taken on 32 patients(12 male, 20 female, mean age of 23.2) treated by bilateral sagittal split osteotomy with rigid fixation. The angular measurement on 3D-CT basilar view were deviation of Me & H, long axis angle of left & right cornu majus. The lineal measurement on 3D-CT basilar view were composed of intercondylar line and coordinates(x,y) of Me & H. The angular & lineal measurement of lateral cephalogram were composed of mandibular plane angle, SNA, SNB, ANB, FH-NA & FH-NB, and coordinates(x,y) of B, Pog, Me & H, PAS, Lpw, MPH and IAS. On the frontal cephalogram, deviation of Me were evaluated. Results : The mean mandibular set-back was 8.0mm horizontally and mandibular plane angle was slightly increased. The hyoid bone was displaced postero-inferiorly, the distance between MP(mandibular plane) and H(hyoid bone) was increased and the posterior airway space values (PAS, Lpw, IAS) were decreased. The coordinates Me(x,y), H(x,y) and deviation angle Me'& H' were revealed the strong positive correlation. Conclusion : The results revealed that the horizontal, vertical and transverse relationship of the mandibular and the hyoid bone movements were significantly correlated in patients performed mandibular set-back surgery.

Wireless Vibration Measurement System Using a 3-Axial Accelerometer Sensor (3축 가속도 센서 기반의 무선 진동 측정 시스템)

  • Yoo, Ju-Yeon;Park, Geun-Chul;Jeon, Ah-Young;Kim, Cheol-Han;Kim, Yun-Jin;Ro, Jung-Hoon;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.131-136
    • /
    • 2011
  • In this study, a compact wireless vibration measurement system was developed using a 3-axial accelerometer in order to evaluate the vibration stimulation system. A low power microprocessor chip integrated with 2.4 GHz RF transceiver was used for the wireless data communication. To evaluate the system, the frequencies and accelerations from the vibration stimulation system were measured using an LVDT sensor and a vibration measurement system. The average frequency difference by the measurement system was less than 0.1 Hz, and the standard deviation of frequencies estimated by the LVDT sensor and the accelerometer was below 0.08 Hz. The developed system was applied to access a vibration stimulation system for the future study. The average acceleration difference of the central and peripheral point of the stimulation system was less than 0.0005 g(1 g=9.8 $m/s^2$), and the standard deviation of the acceleration was below 0.004 g, which shows the usefulness of the wireless vibration measurement system.

Design and Estimation of Cordless Transmitter & Receiver for Measurement of Crane Moving Range (크레인의 이동거리 측정을 위한 무선 송수신기 설계 및 평가)

  • Kim, Tae-Soo;Oh, Inn-Yeal;Chun, Joong-Chang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.4
    • /
    • pp.808-814
    • /
    • 2007
  • In this paper, the measurement system of crane moving range is concerned with range recognition technology using phase and magnitude of radio wave. By the proposed technology, we design the radio transmitter and receiver and realize the measurement system, and save the data in disk that is earned from 900Mhz RF signal, middle frequency 450khz of analog signal. As a result of RF measurement, we got 9.3 dBm of RF output and 96 dBc@10khz of phase noise. Range information is earned the data through digital signal processing of IF signal. For the estimation of range measured, we analyze the difference between real range and measurement range, and also suggest the method to remove the measurement error using average processing and amplitude properties. A result is 0.12 and 0.00422 deviation in l0mn-30m and within 5m respectively, and then 2.4E-04 deviation in 4m by using compensation of level characteristics lately.

An $\overline{X}$-Control Chart Based on the Gini′s Mean Difference (지니(Gini)의 평균차이에 기초한 $\overline{X}$-관리도)

  • 남호수;강중철
    • Journal of Korean Society for Quality Management
    • /
    • v.29 no.3
    • /
    • pp.79-85
    • /
    • 2001
  • Estimation of the process deviation is an important problem in statistical process control, especially in the control chart, process capability analysis or measurement system analysis. In this paper we suggest the use of the Gini's mean difference for the estimation of the process deviation when we design the control limits in construction of the control charts. The efficiency of the Gini's mean difference was well explained in Nam, Lee and Jung(2000). In this paper we propose an $\overline{X}$ control chart which use the control limits based on the Gini's mean difference. In various classes of distributions, the proposed control chart shows food performance.

  • PDF

A Study on the Structure of Three Dimentional Spine, Pelvic Deviation and Foot Pressure in Golf Players (골프선수의 3차원적 척추구조, 골반변위 및 족압에 관한 연구)

  • Yang, Dae-Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.2
    • /
    • pp.151-158
    • /
    • 2012
  • The purpose of this study was to investigate variables of significantly difference as the structure of the spine, pelvic deviation and foot pressure between undergraduates and golf player subjects. The subjects of study were composed of 20 male golf players and 20 male undergraduates. Both groups were right handed persons. The measurement tools of this study were Formetric 4D(Diers, Germany) which is a three dimensional measure. The result are the follows: there were a significant difference between golf players and general students of trunk imbalance, pelvic tilt, pelvic torsion, pelvic rotation, surface rotation, lumbar lordotic curve, foot pressure(fore & behind foot), weight distribution(right & left foot). In conclusion, golf players might cause transform of spine and foot pressure due to golf exercise for several years. Such as imbalance affect to induce functional impairment and pain of musculoskeletal system, and appropriate evaluation and treatment were necessary for golf players.

On the Estimation of the Process Deviation Based on the Gini's Mean Difference (지니(Gini)의 평균차이를 이용한 공정산포 추정)

  • 남호수;이병근;정현석
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.58
    • /
    • pp.113-118
    • /
    • 2000
  • Estimation of the process deviation is an important problem in statistical process control, especially in the control chart, process capability analysis or measurement system analysis. In this paper we suggest the use of the Gini's mean difference for the estimation of the c, the measure of the process deviation through a lots of simulations in various types of distributions. The Gini's mean difference uses the differences of all possible pairs of data. This point will improve the efficiency of estimation. In various classes of distributions, the Gini's mean difference shows good performance, in sense of bias of estimates or mean squared errors.

  • PDF

HOT STRIP WIDTH CONTROL METHOD BY USING LOOPER TENSION MEASURING SYSTEM IN FINISHING MILL (열간 사상압연 투퍼장력 측정에의한 열연판폭제어)

  • 홍완기;김필호;문영훈;이준정
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.423-428
    • /
    • 1999
  • A high precision hot strip width control method has been developed in this study by applying interstand looper tension measuring system at finishing mill stands. As with deviation of hot rolled steel strip is closely related to abnormal increase in the interstand strip tension, on-line measuring device of looped tension and data analyzing system was developed in this study. To determine dominant factors that will cause local width shortage, the logged data sets of bar width, bar thickness, looper tension, and strip thickness along the strip length were correlated with the data set of strip width change. With the result of the correlation analysis, existing sequence control logic and parameters for looper actuator were modified for strip width quality and the gains of the looper control were refined for the stable operation during the full passage of rolled strip. The on-line tension measurement and tension feedback control for looper system improved strip travelling stability and reduced strip width deviation in the srip top end region.

  • PDF

Measurement of Joint Aperture Using 3-D Laser Profilometer (3차원 레이저 측정기를 이용한 절리 간극의 측정)

  • 이희석;이연규;이희근
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.309-320
    • /
    • 2000
  • Aperture is an important parameter for determining the hydraulic characteristics of fractured media. In this study the topography of artificial rock joint surface was measured using 3D laser profilometer to analyze the aperture distribution. The initial aperture distribution was determined when the contact area became one percent of total joint surface. The initial aperture distribution of granite joint, with the mean value of 0.78 mm and the standard deviation of 0.34 mm was much different from that of the marble joint, with the mean value of 0.57 mm and the standard deviation of 0.26 mm. Apertures of both granite and marble showed normal distributions. Aperture distribution with the contact area of 25% was also analyzed. Mean value was decreased to one third compared to the initial aperture, but the standard deviation was decreased slightly. To determine the spatial correlation of the aperture distribution variogram analysis was carried out on the initial aperture data. Most experimental variograms were fitted well with exponential model. It is expected that the measured aperture characteristics can be used for stochastic analysis of fluid flow through rock joints.

  • PDF

The Design and Fabrication of CMOS LNA through De-embedded Verification of the Spiral Inductor (나선형 인덕터의 디임베드 검증을 통한 CMOS LNA 설계 및 제작)

  • Lee, Han-Young;Yoo, Young-Kil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2269-2275
    • /
    • 2008
  • This paper examined the simulation results after applying not only spiral inductor's 3D EM simulation but also de-embedding technique to reduce the pad's RF effects. When calculating standard deviation with measurement results not only the gain at 0.5GHz${\sim}$4GHz but also noise figure at 1.8GHz${\sim}$4GHz, the simulation results includes de-embedded inductor' model improved gain deviation by 0.171 and noise figure deviation by 0.151 than the results from simulation with foundry inductor equivalent circuit models.

A Study on Measurement Accuracy of Theodolite System(II) -A Measurement Accuracy for a Height of Scale Bar (데오드라이트 시스템의 측정 정확도에 대한 연구(II) -기준자 측정 높이에 따른 측정 정확도)

  • 윤용식;이동주;정종길
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.37-43
    • /
    • 2004
  • A measurement accuracy of theodolite system may be affected by a measurement environment, a measurement distance change and so on. This study was performed for measuring an accuracy when the height of scale bar is changed 0.05m, 0.5m, 1m and 1.5m under the distance 3m between two theodolites, the distance 4m from the theodolite system to scale bar and the distance 5m from the thodolite system to the horizontal target bar. And we could know that the best height is 0.05m and 1m.