• Title/Summary/Keyword: Measurement

Search Result 46,743, Processing Time 0.059 seconds

Downlink Signal Measurement Algorithm for WCDMA/HSPA/HSPA+

  • Kwon, Bit-Na;Lee, Eui-Hak;Hong, Dae-Ki;Kang, Sung-Jin;Kang, Min-Goo;Song, Hyoung-Kyu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.8
    • /
    • pp.3040-3053
    • /
    • 2015
  • Wideband code division multiple access (WCDMA), high speed packet access (HSPA) and HSPA+ are third generation partnership project (3GPP) standards. These systems are the major wireless communication standards. In order to test the performance of WCDMA/HSPA/HSPA+ signal in a base station, the measurement hardware is required to the evaluation of the transmitted signals. In this paper, the algorithm for the performance measurement of the WCDMA/HSPA/HSPA+ is proposed. Also, the performance of the measurement algorithm is used to evaluate the generated signal by the WCDMA/HSPA/HSPA+ signal generator. Generally, the algorithm of normal modems cannot be applied to the measurement system because the signal measurement equipment needs to guarantee the high accuracy. So, the WCDMA/HSPA/HSPA+ signal measurement algorithm for the accurate measurement is proposed. By the simulation, it is confirmed that the proposed measurement algorithm has good performance compared with the specification. Therefore, the proposed algorithm can be usefully applied to verify the performance of the measurement using the simulation.

Investigation of the super-resolution methods for vision based structural measurement

  • Wu, Lijun;Cai, Zhouwei;Lin, Chenghao;Chen, Zhicong;Cheng, Shuying;Lin, Peijie
    • Smart Structures and Systems
    • /
    • v.30 no.3
    • /
    • pp.287-301
    • /
    • 2022
  • The machine-vision based structural displacement measurement methods are widely used due to its flexible deployment and non-contact measurement characteristics. The accuracy of vision measurement is directly related to the image resolution. In the field of computer vision, super-resolution reconstruction is an emerging method to improve image resolution. Particularly, the deep-learning based image super-resolution methods have shown great potential for improving image resolution and thus the machine-vision based measurement. In this article, we firstly review the latest progress of several deep learning based super-resolution models, together with the public benchmark datasets and the performance evaluation index. Secondly, we construct a binocular visual measurement platform to measure the distances of the adjacent corners on a chessboard that is universally used as a target when measuring the structure displacement via machine-vision based approaches. And then, several typical deep learning based super resolution algorithms are employed to improve the visual measurement performance. Experimental results show that super-resolution reconstruction technology can improve the accuracy of distance measurement of adjacent corners. According to the experimental results, one can find that the measurement accuracy improvement of the super resolution algorithms is not consistent with the existing quantitative performance evaluation index. Lastly, the current challenges and future trends of super resolution algorithms for visual measurement applications are pointed out.

Development of an Investigation Method for Variation Factors of Measurement Processes (측정 프로세스의 변동 요인 조사 방법 개발)

  • Choi, In-Soo;Kang, Chang Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.2
    • /
    • pp.72-81
    • /
    • 2016
  • There can be included a variety of uncertainties in all measurement results whether we can perceive or not on the causes. These uncertainties may end up in lowering the reliability of measurement results and also deteriorate the level of quality. For the purpose, we tried to combine the strengths of measurement uncertainty and measurement system analysis together to present a practical flowchart so as to verify those potential variation factors in general measurement processes. As a case study, we did an experiment and gathered data on the length between two holes of an engine cylinder head which is a core part for vehicles with a coordinate measuring machine and estimated nine uncertainty factors of it. Consequently, it was identified that the four primary factors among the nine which were related to the measurement standard, random errors or spread of the repeat measurements, differences between the coefficients of thermal expansion and the environment especially had been the influence around the laboratory. Since it is impossible to analyze the equipment and appraisal variations respectively through the only measurement uncertainty, we have used the measurement system analysis following the flowchart. Showing the result of being just about 0.5% lower for the appraisal variation, and the equipment variation occupied about 7% for the total Gage R&R. Through this research, we have come to a conclusion that much more detail analysis on variation factors can be possible to be identified in measurement processes by using the developed flowchart which is composed of measurement uncertainty and measurement system analysis. Therefore, we expect engineers who are involved in quality and measurements to utilize this developed method.

Uncertainty Assessment of Gas Flow Measurement Using Multi-Point Pitot Tubes (다점 피토관을 이용한 기체 유량 측정의 불확도 평가)

  • Yang, Inyoung;Lee, Bo-Hwa
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.5-10
    • /
    • 2016
  • Gas flow measurement in a closed duct was performed using multi-point Pitot tubes. Measurement uncertainty was assessed for this measurement method. The method was applied for the measurement of air flow into a gas turbine engine in an altitude engine test facility. 46 Pitot tubes, 15 total temperature Kiel probes and 9 static pressure tabs were installed in the engine inlet duct of inner diameter of 264 mm. Five tests were done in an airflow range of 2~10 kg/s. The flow was compressible and the Reynolds numbers were between 450,000 and 2,220,000. The measurement uncertainty was the highest as 6.1% for the lowest flow rate, and lowest as 0.8% for the highest flow rate. This is because the difference between the total and static pressures, which is also related to the flow velocity, becomes almost zero for low flow rate cases. It was found that this measurement method can be used only when the flow velocity is relatively high, e.g., 50 m/s. Static pressure was the most influencing parameter on the flow rate measurement uncertainty. Temperature measurement uncertainty was not very important. Measurement of boundary layer was found to be important for this type of flow rate measurement method. But measurement of flow non-uniformity was not very important provided that the non-uniformity has random behavior in the duct.

Design and Verification of Far-field measurement system for W-band Millimeter-wave Antenna (밀리미터파(W대역) 안테나 측정을 위한 원-전계 측정 시스템 설계 및 검증)

  • Baek, Jong-Gyun;Hwang, In-June;Cho, Chi-Hyun;Joo, Joung-Myoung;Joo, Ji-Han;Park, Jong-Kuk;Kim, Jaesik;Kim, Sosu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.43-50
    • /
    • 2022
  • In this paper, we designed and verified a Far-field measurement system for measuring the performance of an antenna operating in millimeter wave(W-band). For the antenna test, a measurement system should be selected according to the type of antenna, measurement items, measurement environment and period, etc. In the case of near-field measurement, it takes a lot of time because the number of measurement items increases when the antenna has multiple channels or various beams. Such an antenna can reduce the measurement time through Far-field measurement, and only necessary measurement items can be measured. Therefore, this study secured precise alignment of the far-field measurement system using a high-power laser and improved the measurement accuracy by applying a double amplifier system. The designed system was built in the anechoic chamber and verified by comparison with the verified Near-field measurement system.

Improvement of Work Environment Measurement in Construction Industry by Survey (설문조사를 통한 건설업 작업환경측정제도 개선방안에 관한 연구)

  • Woo Je, Lee;Won, Choi;Ki Youn, Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.456-464
    • /
    • 2022
  • Objectives: The Purpose of this study is to improve work environment measurement in construction industry by survey. Especially, this study focused on the defferences between construction staffs(safety manger, health manager) and work environment measurement institution workers. Methods: Survey targets are construction staffs(safety manger, health manager) and work environment measurement institution workers. Respondent was selected by respective councils and conferences. A questionnaire consisting of items on general characteristics and the improvement of work environment measurement in construction industry. Results: Total of 134 people(39 safety managers, 27 health managers, 68 work environment measurement institution workers) responded to survey. Overall, current work environment measurement was deemed unsuitable for construction industry. There was a significant difference between construction staff and work environment institution workers in some question. On the other hand, there was no noticeable significant difference in general characteristics. Conclusions: As a result of survey, current work environment measurement was deemed unsuitable for construction industry in terms of measurement method, measurement timing, and actual site improvement. In addition, there is a statistically significant differences in response between construction staff and work environment measurement institution workers, so it is necessary to reflect both opinions in order to improve work environment measurement in construction industry.

Reliability and Validity of Angle of Trunk Rotation Measurement Using Smartphone and 3D Printing Technology in Scoliosis

  • Geum-Dong Shin;Seong-gil Kim;Kyoung Kim
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.6
    • /
    • pp.283-291
    • /
    • 2022
  • Purpose: The purpose of this study was to compare and analyze the method of measuring the angle of the trunk rotation using a smartphone with 3D smartphone holder compared to a scoliometer, which is a measuring tool used as a method for diagnosing scoliosis in scoliosis patients. Methods: Angle of trunk rotation was measured in 21 subjects diagnosed with scoliosis. scoliometer measurement method, a smartphone measurement method with a 3D smartphone holder, a smartphone blind measurement method with a 3D smartphone holder, a smartphone measurement method without a smartphone holder, a smartphone blind measurement method without a smartphone holder, and a total of five measurement methods were repeated three times for comparison and analysis. Results: The smartphone measurement method with a 3D smartphone holder has excellent intra-rater reliability of angle of trunk rotation (Rater A; ICC3, 2≥0.993, Rater B; ICC3, 2≥0.992). The smartphone blind measurement method with a 3D smartphone holder has excellent inter-rater reliability of angle of trunk rotation (ICC2, 2≥0.968). The scoliometer measurement method had the highest validity (r=0.976) with the smartphone measurement method with a 3D smartphone holder, and the blind measurement method without a smartphone holder had the lowest validity (r=0.886). Conclusion: These findings, the angle of trunk rotation measured by the smartphone measurement method with a 3D smartphone holder in scoliosis patients showed high reliability and validity compared to the scoliometer measurement method.

The Study for Apical Pulse Measurement Technique Through Hospitalized Children (입원한 영유아의 심첨 맥박 측정 방법에 관한 연구)

  • Cho Kyung Mi;Kim Eun Joo
    • Child Health Nursing Research
    • /
    • v.5 no.1
    • /
    • pp.48-58
    • /
    • 1999
  • The purpose of this study was to determine the most accurate technique measuring the apical pulse rate, using three counting duration 15, 30 and 60 seconds, and two methods start ‘0’ and start ‘1’. The instrument used in the study was the EKG monitor, stethoscope and stopwatch. Data was analyzed by utilizing SPSSWIN program. General characteristics of the subjects were analyzed by frequency, percentile, mean, SD. The subject of this research is made up of 46 children and 20 nurses. The children were infants, & under the age of 5. They were hospitalised in PICU & NICU in 2 tertiary hospitals in seoul from Jan. 1. 1998 to Sep. 10. 1998. The measurement of starting 1 & measurement of starting ‘0’ used the T-test to find out the measurement error. Apical pulse duration of 15, 30, 60 seconds were used to find out measurement error, the measurement error depend on experience of Nurse were analyzed by using ANOVA. The result of this study are as follows. 1. When comparing the starting poin of apical pulse 0&1, starting with 1 the measurement error is less, but not statiscally significant. 2. When counting the apical pulse by 15, 30,60 sec. ; 60 seconds counting duration was more accurate, but not statistically significant. 3. The mean of measure error ; Group under 100/min, is 10.33 ; from 100 re 119/min, is 8.30 ; from 120 to 139/min, is 4.76 ; from 140 to 159/min, is 6.09 ; above 160, is 17.83. The differences of these groups are statistically significant. When 60sec were counted, under 140/min the mean of measurement error is 3.4. Also when 30 seconds were counted from 140/min to 159/min the measurement error is 7.14, above 160/min the measurement error is 16.4. That measurement mean is the smallest than the other durations. During the 15 sec. count the measurement error was the largest of them all. 4. By the experience of the nurses, the apical pulse count measurement error was discovered. Under a year experience this measurement error was the largest(11.09), 1 year to under 3 years, the error is the smallest(4.86). 3 year to under 6 years the error is 8.33, 5 years above the error is 6.11 but this is not statistical significant. Under a year experience when counting 15, 30, 60 seconds the error is the largest. The group of the nurses from a year to under 3 years, the measurement error is the smallest of all the groups. The result of the study is to determine the technique measuring the apical pulse rate, Hargest (1974), starting point ‘0’ is not proved. When the pulse rate increases the 30 sec measurement rate is accurate. Under 140/min the 60 sec measurement rate is the most accurate. Depending on the nurses experiences, there is a variable difference to the apical pulse rate measurement. Especially new nurses training courses should enforce the children’s pulse rate count and the basic vital signs.

  • PDF

Statistical Study on the Measurement Assurance Program in Environmental Pollution Measurement Activities -The Round-Robin Test about Water Pollution- (水質汚染物質의 共同試料分析調査)

  • 李載昌;申漢豊;李樂榮
    • Journal of the Korean Statistical Society
    • /
    • v.9 no.2
    • /
    • pp.194-212
    • /
    • 1980
  • This report describes a preliminary study necessary to implement Measurement Assurance Program (MAP). The purpose of the study is to improve the measurement reliability of the laboratories which take environmental pollution measurement. We carried out the interlaboratory test or "Round-Robin" test program in which seven laboratories participated in order to obtain more reliable data about water pollution.pollution.

  • PDF

Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test (엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석)

  • Yang, In-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.