• 제목/요약/키워드: Measurement

검색결과 46,792건 처리시간 0.064초

다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교 (Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure)

  • 송효숙;전태국;최은정;김미정
    • 기본간호학회지
    • /
    • 제8권3호
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

한국산업의 계측투자실태분석 (An Analysis on the status of Measurement Investment in Korean Industry)

  • 김동진;남경희
    • 품질경영학회지
    • /
    • 제20권2호
    • /
    • pp.76-93
    • /
    • 1992
  • The purpose of this study, by surveying the status of firms, measurement-related investment and the defect rate, is to analyze the effect of measurement-related investment and to propose a scheme of efficient measurement-related investment which reduces the defect rate. For this project we obtain the data of the status of the measurement-related investment and the defect rate of 928 firms in Korean manufacturing industry by mailing survey. One of our results shows that the firms which have measurement standard laboratory, i.e, which invest in measurement-related area comparatively high, have the defect rate about 0.8% lower than those firms which don't have measurement standard laboratory. Also we find that the small-and-middle size firms have worse measurement-related facility than the large firms and the firms in the heavy-chemical industry have higher measurement-related investment effect than the firms in the light industry.

  • PDF

KTX 주행안정성 평가를 위한 진동가속도 계측데이터의 신호처리에 관한 연구 (A Study on The Measurement System of Acceleration Data To Estimate Operating KTX High Speed Train)

  • 강태원;김유승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1020-1023
    • /
    • 2009
  • A purpose of this study measure the acceleration of operating KTX high speed train to find out something wrong to obtain reliable the acceleration measurement data. The existing measurement system come about a difference between measurement data of running off the track with the acceleration measurement data of operating KTX high speed train. Therefore, the measurement system needs make up for the weak points in the current system. This study analyze existing measurement system and the acceleration measurement data to introduce the synchronization of the existing measurement system and the acceleration measurement and will be reasonable to this sampling through field test.

  • PDF

개선 구산 계측함수에 의한 디지털 계측시스템의 정밀도 향상 (Accuracy Improvement of Digital Measurement System by Modified Piecewise Measuring Functions)

  • 홍성훈;강문성
    • 제어로봇시스템학회논문지
    • /
    • 제7권2호
    • /
    • pp.138-145
    • /
    • 2001
  • Measurement errors in a digital measurement systems are mainly due to the consisting elements accuracies and the circuit parameters changes following the environment variations such as temperature. Further, systems non-linearity makes the measurement accuracy worse, and accordingly a linearization method should be considered to avoid this worsening. In this study, a temperature error-correction method and linearization methods are proposed and a digital temperature measurement system utilizing these methods is realized. And the proposed measurement methods are observed to increase the measurement accuracy of the digital measurement system.

  • PDF

Research on a Method for the Optical Measurement of the Rifling Angle of Artillery Based on Angle Error Correction

  • Zhang, Ye;Zheng, Yang
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.500-508
    • /
    • 2020
  • The rifling angle of artillery is an important parameter, and its determination plays a key role in the stability, hit rate, accuracy and service life of artillery. In this study, we propose an optical measurement method for the rifling angle based on angle error correction. The method is based on the principle of geometrical optics imaging, where the rifling on the inner wall of the artillery barrel is imaged on a CCD camera target surface by an optical system. When the measurement system moves in the barrel, the rifling image rotates accordingly. According to the relationship between the rotation angle of the rifling image and the travel distance of the measurement system, different types of rifling equations are established. Solving equations of the rifling angle are deduced according to the definition of the rifling angle. Furthermore, we added an angle error correction function to the method that is based on the theory of dynamic optics. This function can measure and correct the angle error caused by the posture change of the measurement system. Thus, the rifling angle measurement accuracy is effectively improved. Finally, we simulated and analyzed the influence of parameter changes of the measurement system on rifling angle measurement accuracy. The simulation results show that the rifling angle measurement method has high measurement accuracy, and the method can be applied to different types of rifling angle measurements. The method provides the theoretical basis for the development of a high-precision rifling measurement system in the future.

한의학 임상연구에서의 심박변이도 검사 활용현황과 측정조건에 대한 고찰 (Review on Current Status of Use and Measurement Condition of Heart Rate Variability in Clinical Study of Korean Medicine)

  • 김상호
    • Journal of Acupuncture Research
    • /
    • 제29권5호
    • /
    • pp.127-137
    • /
    • 2012
  • Objectives : The purpose of this study is to review on current status of use and measurement condition of heart rate variability(HRV) by reviewing clinical studies published in journal of Korean medicine registered Korea citraion index(KCI). Methods : One hundred twenty articles were found by searching the representative Korean databases. At first analysis was performed by current status of use(journal, academic field of corresponing author, purpose of study, disease of subject, HRV measurement devices, intervention methods and tests compared to HRV). At second analysis was performed by measurement condition(uncontrolled study, relaxation before measurement, measurement position, measurement place, measurement time period and restriction of smoking, alcohol, caffeine, meal). Results : The analysis showed that department of acupuncture & moxibustion, department of oriental neuropsychiatry are major part in journal & academic field. The purpose of study were classified under studies to verify therapeutic effect on normal subject(39%), to verify therapeutic effect on the patients(8%), to investigate characteristics of the patients(34%) and to be compared with other test(19%). Disease of subject & measurement devices in article were so various. Major intervention methods were acupuncture(61.4%), mind-body intervention(19.2%). Studies that measurement condition were not controlled were relax time(24%), measurement position(19%), measurement place(26%), measurement time period(91%) and restriction of smoking, alcohol, caffeine, meal(49%). Conclusions : This study showed that current status of use of HRV is widespread in Korean medicine but more controlled measurement conditon are needed to get more reliable result from clinical studies and to improve diagnosis and treatment of Korean medicine.

중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구 (Comparison of Size between direct-measurement and 3D body scanning)

  • 차수정
    • 패션비즈니스
    • /
    • 제16권1호
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

Antenna Measurement on Cylindrical Surface in Fresnel Region Using Direct Far-Field Measurement System

  • Oh, Soon-Soo;Kim, Joung-Myoun;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • 제29권2호
    • /
    • pp.135-142
    • /
    • 2007
  • The small anechoic chambers built by many small-/medium-sized companies and universities present difficulties in testing electrically large antennas because the chamber size cannot satisfy the far-field criterion of large antennas. In this paper, a method for Fresnel-region measurement on a cylindrical surface with variation of the measurement height is proposed and verified by both calculations and experiments. We implement the proposed method using a direct far-field measurement system by adding a few supporting structures. The results show good accuracy.

  • PDF

접지된 Shield Plate를 이용한 집적회로의 배선용량 측정 (Direct Measurement of the VLSI Interconnection Line Capacitances Using a Grounded Shield Plate)

  • 강래구;전성오;신윤승
    • 대한전자공학회논문지
    • /
    • 제25권3호
    • /
    • pp.302-307
    • /
    • 1988
  • A noble interconnection line capacitance measurement method to be able to remove the measurement errors from the probe pad to substrate stray capacitance has been proposed and verified. The measurement errors in the capacitance measurement, which usually be involved from the probe pad to substrate stray capacitance, can easily be removed by isolating the metal probe pad from the substrate with a grounded shield plate between the probe pad the substrate. The measurement results by using this improved capacitance measurement method were compared with the calculations by two-dimensional computer simulations.

  • PDF

Loop Selective Direction Measurement for Distance Protection

  • Steynberg, Gustav;Koch, Geyhard
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.423-426
    • /
    • 2006
  • Distance relays achieve selective tripping by measurement of all short circuit fault conditions inside set reaches. The direction of the fault, forward or reverse is commonly determined with a dedicated measurement to ensure selectivity under all conditions. For the direction decision (measurement) a number of alternatives are available. This paper describes a loop selective direction measurement and illustrates by means of a typical fault why this is superior to a non loop selective direction measurement such as that based on negative sequence quantities.