• 제목/요약/키워드: Measured ASF

검색결과 17건 처리시간 0.026초

비만의 한방치료 효과 및 집단 간 효과차이에 관한 연구 (A Clinical Study about the Effects of oriental medical therapy on obesity and different effects between groups)

  • 이수정;김원일
    • 한방안이비인후피부과학회지
    • /
    • 제25권3호
    • /
    • pp.97-112
    • /
    • 2012
  • Objectives : The purpose of this study were to evaluate the effects of oriental medical therapy on obesity and different effects according to Body Mass Index(BMI), menopause, obesity treatment experience, age, treatment period in patients. Methods : 46 patients were treated from November 2011 to April 2012 in Oriental Obesity Center, Dong-eui Medical Center. They were measured change of body compositions by bioelectrical impedance analysis every 2~3 weeks and 27 patients out of 46 were checked body compositions every 2 weeks. 46 and 27 patients were divided into two or three groups according to BMI, menopause, obesity treatment experience, age, treatment period. We compared before and after treatment body compositions. Results : Body compositions, except edema index were significantly reduced. Abdominal Visceral Fat(AVF) was significantly reduced in Obese group. Body Weight(BW), BMI, Body Fat(BF), Body Fat Percetage(BFP), Abdominal Visceral Fat Level(AVFL), Abdominal Visceral Fat(AVF), Abdominal Subcutaneous Fat(ASF) were significantly reduced in non-menopause group(43 female patients). But in 26 female patients out of 27, there were no significantly differences between groups in menopause. There were no significantly differences between groups in obesity treatment experience. But in 27 patients, BMI and AVF were significantly reduced in non-experience group and AVFL was significantly reduced in experience group. BW, BMI, BF, BFP, VAF, ASF were significantly reduced in younger age group. But in 27 patients, BW and Muscle were significantly reduced in younger age group. BMI, BF, BFP, Edema, AFVL, Abdominal Visceral Fat Area(AVFA), AVF, ASF were significantly reduced in longer treatment period group. Conclusion : The BF, BMI, BF, BFP, Muscle, AVFL, AVFA, AVF, ASF were almost decreased significantly. It resulted that the effects of oriental medical therapy in obesity was positive. And it was meaningful study to know about different effects between groups.

포항 로란-C(9930M) 이용 영일만 dLoran 측정 (dLoran Measurement in Yeongil Bay using the Pohang Loran-C (9930M))

  • 이창복;이종구;이영규;황상욱;이상정;양성훈
    • 한국항해항만학회지
    • /
    • 제38권3호
    • /
    • pp.227-232
    • /
    • 2014
  • dLoran과 ASF 데이터 맵 그리고 로란 데이터 채널은 eLoran 시스템의 중요한 3 요소이다. dLoran은 eLoran 기술의 핵심 기술로 ASF 보정을 통해 항법 정확도를 향상시키는 기술이다. 이러한 dLoran 보정을 통해 항만 접안(HEA)시에 8~20 m 정확도의 항법 성능을 얻을 수 있다. 본 연구에서는 로란 9930M 체인 중에 주국인 포항 송신국의 신호를 이용하여 dLoran 측정을 하였다. 영일만 해상을 대상으로 dLoran 기준국을 포항 호미곶 표지관리소에 설치하고 시험용 수신기를 흥환 해수욕장에 설치하여 dLoran 측정의 유효성을 평가하였다. 그 결과 표지관리소 dLoran 기준국의 TOA 측정 데이터와 흥환 시험국의 이용자 수신기 TOA 측정 데이터의 하루 동안의 차분 데이터는 약 10~30 ns (거리오차: 3~9 m) 이내로 일치하고 있어서 이 dLoran 측정 데이터로 이용자의 ASF 측정값을 보정하면 eLoran의 항만 접안에서의 항법 정확도를 만족할 수 있다.

eLoran 송신국 배치 최적화 방안 연구 (A study on the optimal geometrical placement of eLoran stations in Korea)

  • 이창복;신미영;황상욱;이상정;양성훈
    • 한국항해항만학회지
    • /
    • 제37권1호
    • /
    • pp.35-40
    • /
    • 2013
  • eLoran에서의 항법 성능을 결정하는 주요 오차요인은 수신기의 eLoran 측정치인 TOA 측정치 오차와 수신기와 송신국들 사이의 기하학적인 배치(GDOP)에 의한 오차로 구분할 수 있다. TOA 측정치의 오차 보정을 위해서는 dLoran 기준국에서 측정한 ASF 변동값을 LDC를 통해 이용자에게 제공하면 가능하다. 또한 송신국들의 기하학적 배치에 따른 위치측정 정확도는 DOP로 결정되며 송신국의 최적의 기하적인 배치는 항법 정확도를 향상시킨다. 본 연구에서는 eLoran 구축에 대비하여 우수한 항법 성능을 갖는 데 필요한 eLoran 송신국의 기하학적인 배치를 결정하였고, 최대 6 개까지 송신국을 배치할 경우에 대해 각각의 항법 성능을 평가하였다. 제안된 eLoran 송신국 배치 방안은 항만에서 항법 및 시간주파수 와 관련하여 요구하는 HEA 정확도를 만족하는 eLoran 시스템을 구축할 때에 활용될 수 있다.

실제 eLoran TOA 측정치를 이용한 GPS Aided 오차 보상 기법과 항법 알고리즘의 검증 (Verification of GPS Aided Error Compensation Method and Navigation Algorithm with Raw eLoran Measurements)

  • 송세필;최헌호;김영백;이상정;박찬식
    • 제어로봇시스템학회논문지
    • /
    • 제17권9호
    • /
    • pp.941-946
    • /
    • 2011
  • The Loran-C, a radio navigation system based on TDOA measurements is enhanced to eLoran using TOA measurements instead of TDOA measurements. Many error factors such as PF, SF, ASF, clock errors and unknown biases are included in eLoran TOA measurements. Because these error factors can cause failure in eLoran navigation algorithm, these errors must be compensated for high accuracy eLoran navigation results. Compensation of ASF and unknown biases are difficult to calculate, while the others such as PF and SF are relatively easy to eliminate. In order to compensate all errors in eLoran TOA measurements, a simple GPS aided bias compensation method is suggested in this paper. This method calculates the bias as the difference of TOA measurement and the range between eLoran transmitters and the receiver whose position is determined using GPS. The real data measured in Europe are used for verification of suggested method and navigation algorithm.

NDGPS와 LORAN-C 기반의 항법 방안 연구 (A Navigation Method Based on the NDGPS and LORAN-C)

  • 신미영;박찬식;이창복;서상현;이상정
    • 제어로봇시스템학회논문지
    • /
    • 제12권9호
    • /
    • pp.891-897
    • /
    • 2006
  • The coverage of the NDGPS is nationwide currently and by 2007 more than 2 NDGPS signal will be available in most of Korean peninsula both coastal area and inland. The role of NDGPS beacon is transmitting pseudorange corrections however if range or pseudorange can be measured from NDGPS beacon signal, it might be possible to construct an independent regional navigation system: The range from NDGPS beacon signal can be used as additional measurements to remove GPS shadow area and to improve accuracy and reliability of GPS. Furthermore, by adding Loran-C, a regional radio navigation system without GPS can be possible. In this paper, a feasibility study on the regional positioning system using NDGPS and LORAN-C are given. The results show that the NDGPS and LORAN-C can be used as a ground based regional navigation system if requirements such as synchronization of NDGPS network, dual coverage of NDGPS, navigation algorithm for both NDGPS and LORAN-C measurements and an efficient ASF compensation method are met.

포항 로란-C 송신 신호의 기준위상 오프셋 측정 (Measurement of Reference Phase Offset for the Loran-C Transmitting Signal of Pohang)

  • 이창복;원성호;이종구;김영재;이상정;양성훈
    • 한국항해항만학회지
    • /
    • 제36권6호
    • /
    • pp.475-480
    • /
    • 2012
  • eLoran (enhanced Long Range Navigation)의 구축을 위해서는 로란시스템 설비업그레이드, 시스템 정보데이터 채널추가, dLoran (differential Loran) 사이트, ASF(Additional Secondary Factor) 데이터베이스 등이 필요하다. 특히 eLoran 송신국들의 정확한 UTC (세계협 정시, Coordinated Universal Time) 동기는 eLoran 시스템의 항법성능 향상을 위해 필수적이다. 따라서 송신국들의 정확한 UTC 동기를 위해서는 송신국의 절대 지연시간 측정 및 모니터링이 필요하며, 측정된 송신국 지연시간의 변화량을 보정정보로 이용자에게 제공하여야 한다. 본 연구에서는 포항 LORAN-C 송신국(9930M)을 대상으로 수신지점에서의 TOA(Time of Arrival) 산출을 위한 송신신호의 기준시점을 측정하는 방법을 제시하였고 지연측정 시스템 및 송출신호 위상 모니터링 시스템을 개발하여 포항 송신국의 기준시점을 평가하였다. 측정결과 포항 송신국의 기준점 오프셋은 $-2.23{\mu}s$로 측정되었으며 송신 로란펄스의 위상을 관측한 결과 1 개월간에 약 $0.3{\mu}s$ 정도 흐르는 것이 관측되어 로란의 PNT(Positioning, Navigation and Timing) 활용을 위해 위상 모니터링과 보상이 필수적임을 알 수 있었다.

시판 빵 효모의 발효 특성 및 제빵성에 관한 연구 (A Study on the Fermentative Abilities and Baking Properties of Commercial Yeast)

  • 김원주;한영숙
    • 한국식품조리과학회지
    • /
    • 제20권5호
    • /
    • pp.529-536
    • /
    • 2004
  • 이에 본 연구에서는 시판 국내외산 효모 11종을 구입하여 발효특성 및 제빵성을 비교하여 효모 생산사업의 향상을 위한 기초자료를 제시하고자 하였다. 효모의 $CO_2$ 생성량, 반죽 팽창력, maltose 발효력 등을 측정하였고, 무당ㆍ저당ㆍ고당 반죽에 적용시켜 발효력 측정 및 실제 빵을 제조하여 관능평가를 실시하였다. 또한 배양한 효모의 maltase activity와 freeze tolerance rate를 측정하여 균주 특성을 비교하였다. 이 균주들은 동정하여 다음과 같은 결과를 얻었다. Meissle 발효관을 이용하여 시판 빵효모가 저당반죽에서 3시간 동안 $CO_2$를 생성한 양을 측정한 결과 Y7이 가장 높은 값을 나타냈고, Y5와 Y4가 그 뒤를 이었다. M-Cylinder를 이용하여 측정한 11종의 효모의 반죽 팽창력은 Y7, Y4,. Y5 등의 순으로 $CO_2$ 생성량을 측정한 결과와 일치하여 우수 균주로 Y7을 선별하여 이하의 실험에 이용하였다. ASF 합성배지에서의 maltose 발효 능력은 Y5, Y7, Y4 등의 순으로 나타나 $CO_2$ 생성량, 반죽 팽창력과는 약간의 차이가 있었다. 이때 선별된 Y7에 대해 비교 균주로 국내산 효모 K의 반죽종류에 따른 발효력을 비교한 결과 Y7이 K보다 무당, 저당 반죽에서 더욱 우수한 것으로 나타났다. Y7과 K를 이용하여 바게트(무당빵), 식빵(저당빵), 모닝롤(고당빵)을 제조한 후 빵의 품질을 측정한 결과 바게트에서는 K의 용적이 Y7보다 많이 부풀었으며, 비용적도 조금 더 높았다. 그러나, 식빵에서는 Y7의 용적이 K에 비해 더 많이 부풀었으며, 비용적도 더 높아서 Y7이 식빵 제조에 더 적합한 것으로 보였다. 모닝롤에서는 K와 Y7의 용적, 비용적이 매우 유사하여 두 균주가 모두 모닝롤 제조에 적합한 것으로 생각되었다. 또한 이 빵들을 이용하여 관능평가한 결과 바게트의 전반적인 기호도는 K와 Y7이 동점으로 유의적인 차이를 보이지 않았다. 식빵은 외상의 모든 항목과 색에서 K가 높은 점수를 얻었다. 모닝롤은 외상의 껍질 색, 질, 두 항목에서 K가 더 높은 점수를 얻으며 유의적인 차이를 보였고, 전반적인 기호도에서는 또한 유의적인 차이를 보이지 않았다.