• Title/Summary/Keyword: Measure height

Search Result 781, Processing Time 0.03 seconds

Development of Kid Height Measurement Application based on Image using Computer Vision (컴퓨터 비전을 이용한 이미지 기반 아이 키 측정 애플리케이션 개발)

  • Yun, Da-Yeong;Moon, Mi-Kyeong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.117-124
    • /
    • 2021
  • Among growth disorders, 'Short Stature' can be improved through rapid diagnosis and treatment, and for that, it is important to detect early'Short Stature'. It is recommended to measure the height steadily for early detection of 'Short Stature' and checking the kid's growth process, but existing height measurement methods have problems such as time and space limitations, cost occurrence, and difficulty in keeping records. So in this paper, we proposed an 'Development of Kid Height Measurement Application based on Image using computer vision' method using smart phones, a medium that is highly accessible to people. In images taken through a smartphone camera, the kid's height is measured using algorithms from OpenCV, a computer vision library, and the measured heights were printed on the screen through 'a comparison graph with the standard height by gender and age' and 'list by date', made possible to check the kid's growth process. It is expected to measure height anytime, anywhere without time and space limitations and costs through this proposed method, and it is expected to help early detection of 'Short Stature' and other disorder through steady height measurement and confirmation of growth process.

Research on Influence Factors on Pulmonary Functions in Korean-Chinese Children

  • Kim, Dae-Seon;Yu, Seung-Do;Cha, Jung-Hoon;Na, Jin-Gyun
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.192-195
    • /
    • 2003
  • To identify the difference between Korean-Chinese and Korean children's variation of pulmonary function with personal factors (suck as age, height, and weight), we performed pulmonary function test (PFT) and measured personal factors of 200 Korean-Chinese children participants from two elementary schools of Beijing and Melons city in China. Regression analysis was utilized to determine which personal factors were significantly correlated with PFT measure (FVC and FEV$_1$). We compared the regression model from this study with those of other studies of Korean children. Similar to other studies, we found that the most important variable, influencing PFT measure, was height, whereas addition of either age or weight in the regression virtually did not increase the accuracy. As the result of comparison of the regression model from this study with those of other studies of Korean children, variation in FVC or FEV$_1$ with height were similar.

  • PDF

Snow-Falling Measurement System monitoring the Height of Snow using the Photo Coupler (포토카플러를 이용한 눈(snow)높이 감지 강설 계측시스템)

  • 최만용;박해원;박정학;김원태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.517-520
    • /
    • 2003
  • The snow-fatting measurement system including the snow sensor applying the photo-coupler is investigated in this study and using this snow sensor the height of snow fallen is measured. To measure the snow depth, five photo sensors are arranged with 5 mm distance. The snow-falling measurement system, which is measuring the motor revolution controlled with stepping motor, is mounted above the snow surface. From this work, it is feasible to measure quantitatively the snow on real time. Its software implements a proven method to achieve valid measurements also under difficult conditions as future study. In cases where the snow sensor is applieded to the prediction of snow in the meteorological observation system and the snow removing system, it is recommend the GRS-Option in order to improve the quality of snow measurements for better compensation.

  • PDF

Consideration on the Experimental Measurement of Flaw Height of Welds by Ultrasonic Testing (초음파(超音波) 탐상법(探傷法)에 의(依)한 용접부(熔接部)의 결함(缺陷)높이 측정(測定)에 관한 연구(硏究))

  • Ahn, Il-Young;Yin, Tong-Kyu;Han, Eung-Kyo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.2 no.1
    • /
    • pp.10-16
    • /
    • 1982
  • This study was carried out to measure the flaw height of welds in consideration of the effective probe angle in ultrasonic oblique detection. Specimens with inserted artificial flaws were made and flaw heights were estimated from detecting these specimens. Two different methods were applied to estimate flaw heights. From the result of the experiment, flaw height could be measured within the accuracy of 15% percent error and the difference between the probe distance method and beam path method is about 5% relatively small. It is considered that the results obtained this experimental study could be helpful informal ions for measuring flaw height.

  • PDF

Plyometrics and vibration: no clear winner on efficacy

  • Hubbard, R. Jeremy;Petrofsky, Jerrold S.;Lohman, Everett;Berk, Lee;Thorpe, Donna
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.2
    • /
    • pp.86-92
    • /
    • 2014
  • Objective: Whole body vibration (WBV) and plyometrics are common training techniques which increase strength, blood flow, and lower body force and power. The effects these techniques have on sedentary population is unknown. It is our aim to assess the effectiveness of WBV and plyometrics on sedentary population. Design: Experimental study. Methods: Twenty-seven sedentary subjects were assigned to either the control group, jumping only group, or jumping with vibration group. Jump height (myotest or vertec), velocity, force, blood lactates, and rating of perceived exertion (RPE). Subjects were measured on the initial, seventh, and eighteenth visits. Control group attended measurements only. Jumping only and jumping with vibration groups performed jumping from a vibrating platform to a surface 7 1/2 inches higher for 3 bouts of 20 seconds. Each subject in jumping only and jumping with vibration groups attended three times per week for six weeks. Vibration was set at 40 Hz and 2-4 mm of displacement. Results: There was no significant change among groups in force, velocity, vertec height, and myotest height. However there was a significant increase in vertec height from initial to final measure (p<0.05) for jumping with vibration group. RPE was significantly higher between control group and jumping with vibration group after intervention (p<0.05). Conclusions: WBV with vibration increased jump height. Jumping with vibration group experienced increased exertion than for controls. WBV with plyometrics had no effect on force, velocity, blood lactates, or calculated jump height. Further studies controlling for initial measure of blood lactates and using an external focus may be necessary to elicit velocity, force and jump height changes.

A Laboratory Study on the suitable standard height for the lavatory in public spaces (공공용 세면대의 적정 높이 기준에 대한 실험연구)

  • 신경주
    • Journal of the Korean housing association
    • /
    • v.11 no.2
    • /
    • pp.63-73
    • /
    • 2000
  • The purpose of this study was to find a suitable standard height of the lavatory in public spaces through the review of relevant regulations, questionnaire survey, lab works, and experiment to measure lavatory heights. The results of the study were as follows: First, the heights of the current public lavatory were ranged from 68cm to 89cm, and the heights to the faucet were from 71cm to 91cm. The recent lavatory was more likely to be higher in heights. Secondly, the suitable height for public lavatory was ranged from 55% to 65% of the heights of the participants put on shoes. Thirdly, 90cm lavatory in height was considered to be more suitable to use for the majority than was 83cm lavatory. Fourth, the author suggest that the suitable y(lavatory height)=77.818 + 0.117x(put on shoes heights). This study suggested that adopting 95% range, the most suitable height of public lavatory is more than 90cm high for the people whose heights are more than 150cm.

  • PDF

An Image-Based Remote Snow Height Measurement System using a USN (이미지 및 USN 기반 원격 적설량 측정 시스템)

  • Lee, Hyung-Bong;Moon, Jung-Ho;Chung, Tae-Yun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.2
    • /
    • pp.76-85
    • /
    • 2011
  • In conventional methods for measuring snow height, a graduated pole is installed on ground in an area of interest and the snow height is manually read from the pole. Recently, automated snow height measurement systems have been introduced to improve the conventional methods. The automated measurement systems, however, are quite expensive since they use the reflection of ultrasonic waves or laser beams. In addition, it is not easy to move the location of the automated measure systems. This paper proposes a snow height measurement system equipped with image sensors and wireless communication capability via a USN and the Internet. The proposed system has a resolution of 5 cm and easy to deploy without difficulties, which can be usefully used to monitor unforseen local snowfalls.

Dress and conditional posture for anthropometric measure of women in old age (노년 여성의 인체측정시 착의조건 및 자세)

  • 성화경;김인순
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.7
    • /
    • pp.1239-1246
    • /
    • 2001
  • This study has analyzed the length, and angle measurements under different conditions supposing that there is a difference in the anthropometric measure of women in old age. As a result, the measurements of chest breath, bust depth, and bust height has decreased when not wearing a brassiere. Also, the neck angle has decreased when straightening oneself, while the angle from the posterior waist to back increased. The elderly Women appear to have a difference in the measurement in accordance with the posture and dress conditions.

  • PDF

An Analysis on Upper Extremity and Trunk EMG of Elderly for Table Height Using Electronic Bed (고령자의 전동침대 사용 시 테이블 높이에 따른 상지와 체간의 근활성도 분석)

  • Lee, Myoung-Hee;Lee, Sang-Yeol
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.3
    • /
    • pp.443-448
    • /
    • 2013
  • PURPOSE: In recent years, senior friendly device is growing rapidly because of population aging The study was designed to investigate the effects of table height of electronic bed on upper extremity and trunk EMG in elderly. METHODS: Thirty right-handed elderly without history of neurological and musculoskeletal dysfunction were participated in this study. Three heights of the table (3/3 height, 2/3 height, and 1/3 height between top of the shoulder and olecranon) were provided. During the eating performance, surface electromyography (EMG) was used to measure muscle activity, and electrodes were attached to the deltoid middle fiber, serratus anterior, suprapinatus, upper trapezius, rhomboideus, cervical part of longissimus, thoracic part of longissimus, lumbar part of longissimus on right. One way ANOVA was conducted for the statistical analysis. RESULTS: There were significant differences in deltoid middle fiber, suprapinatus, upper trapezius, rhomboideus, lumbar part of longissimus in the 3 different height of table (p<.05). The deltoid middle fiber, suprapinatus, upper trapezius, and lumbar part of longissimus were significantly increased in higher table than lower table(p<.05). And the rhomboideus was significantly decreased in higher table than lower table(p<.05). CONCLUSION: This study demonstrates that different height of table affect upper extremity and trunk muscle activity. The table height of olecranon is the best for elderly.

Prediction of Sludge-Water Interface Height Change in Batch Column (Batch Column에서의 슬러지계면층 높이변화 예측)

  • Park, Suk Gyun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.156-163
    • /
    • 2006
  • While sludge is settling in batch column, sludge concentration becomes high. Because the characteristic of sludge settling changes in function of time due to the sludge concentration change, the sludge settling velocity changes too. Also, because the sludge settling characteristic is influenced by a physical characteristic of sludge and a column height etc, it is difficult to exactly measure the sludge settling characteristic. Although the sludge volume indexes, SVI, SSVI and $SSVI_{3.5}$, are used to predict sludge settling characteristic, these indexes are not reliable values. Because the previously established models for sludge settling velocity predict the sludge settling velocity only, it is difficult to predict sluge-water interface height by using those models. The purpose of this experiment is to establish the empirical model which predicts the sludge interface height change with respect to the sludge physical characteristic and the settling condition.