• Title/Summary/Keyword: Measure energy

Search Result 1,935, Processing Time 0.026 seconds

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Research on the Methods and Proper Provisions for Rotational Irrigation (윤환관개방법과 적정시설 연구)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2191-2205
    • /
    • 1971
  • In this research, Nong-rim No. 6 was adopted as a test variety of rice. Rice seedlings were transplanted on June 14, 1970. Roots were settled into soil on June 20 and a total number of days irrigated of $21cm{\times}21cm$ and an area of $9.9m^2$ for a test plot were accepted, planting 70 stumps of rice in a test plot. The soil in test plots are classified by soil test as oam, and its chemical contents are as shown in Table 3. Irrigation water was secured by pumping from the Sudun stream that originates at the Suho reservoir. Accordingly, the qualities of irrigation. water are considered to be the same as those of water stored in the Suho reservoir. There were 54 days of intermittent rainfalls in total during the whole 110-day period of irrigation. As a result, it is likely that the growth of rice plants was influenced by rainfall at a comparatively great degree. In order to measure the amounts of water consumption, infiltrometers, measuring devices for the decreases of water depths and lycimeters were provided. As a result of measurements, an average daily rate of infiltration was observed to be 14mm/day. It is expected from this research that the effect of increased yield will be secured by supplying optimum amounts of water for irrigation on proper times, and that the amounts of water consumption for irrigation can be saved by applying suitable irrigation methods. The test results obtained are summarized as follows: 1. Yields produced in the test plots of continuous irrigation are lower than those in the test plots of rotational irrigation, i.e., yields produced at the test plots irrigatied once in a period of 8 days are higher by 27% in average than those produced at test plots of continuous irrigation. 2. The amounts of irrigation water for test plots, which have a clay layer of 9cm in thickness and vynil diaphragm without holes, are saved by about 52% in comparison with ordinary test plots. 3. Ears are sprouted 5 days earlier at continuous irrigation plots as compared with other test plots. 4. It seems that there are growing stages of rice plants such as those of forming and sprouting of ears, in which the amounts of irrigation water are consumed more in comparison with the other stages. Therefore, it may be possible to increase of decrease the amount of irrigation water, according to the growing stage of rice plant, so as to save irrigation water.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Changes in blood pressure and determinants of blood pressure level and change in Korean adolescents (성장기 청소년의 혈압변화와 결정요인)

  • Suh, Il;Nam, Chung-Mo;Jee, Sun-Ha;Kim, Suk-Il;Kim, Young-Ok;Kim, Sung-Soon;Shim, Won-Heum;Kim, Chun-Bae;Lee, Kang-Hee;Ha, Jong-Won;Kang, Hyung-Gon;Oh, Kyung-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.308-326
    • /
    • 1997
  • Many studies have led to the notion that essential hypertension in adults is the result of a process that starts early in life: investigation of blood pressure(BP) in children and adolescents can therefore contribute to knowledge of the etiology of the condition. A unique longitudinal study on BP in Korea, known as Kangwha Children's Blood Pressure(KCBP) Study was initiated in 1986 to investigate changes in BP in children. This study is a part of the KCBP study. The purposes of this study are to show changes in BP and to determine factors affecting to BP level and change in Korean adolescents during age period 12 to 16 years. A total of 710 students(335 males, 375 females) who were in the first grade at junior high school(12 years old) in 1992 in Kangwha County, Korea have been followed to measure BP and related factors(anthropometric, serologic and dietary factors) annually up to 1996. A total of 562 students(242 males, 320 females) completed all five annual examinations. The main results are as follows: 1. For males, mean systolic and diastolic BP at age 12 and 16 years old were 108.7 mmHg and 118.1 mmHg(systolic), and 69.5 mmHg and 73.4 mmHg(diastolic), respectively. BP level was the highest when students were at 15 years old. For females, mean systolic and diastolic BP at age 12 and 16 years were 114.4 mmHg and 113.5 mmHg(systolic) and 75.2 mmHg and 72.1 mmHg(diastolic), respectively. BP level reached the highest point when they were 13-14 years old. 2. Anthropometric variables(height, weight and body mass index, etc) increased constantly during the study period for males. However, the rate of increase was decreased for females after age 15 years. Serum total cholesterol decreased and triglyceride increased according to age for males, but they did not show any significant trend fer females. Total fat intake increased at age 16 years compared with that at age 14 years. Compositions of carbohydrate, protein and fat among total energy intake were 66.2:12.0:19.4, 64.1:12.1:21.8 at age 14 and 16 years, respectively. 3. Most of anthropometric measures, especially, height, body mass index(BMI) and triceps skinfold thickness showed a significant correlation with BP level in both sexes. When BMI was adjusted, serum total cholesterol showed a significant negative correlation with systolic BP at age 12 years in males, but at age 14 years the direction of correlation changed to positive. In females serum total cholesterol was negatively correlated with diastolic BP at age 15 and 16 years. Triglyceride and creatinine showed positive correlation with systolic and diastolic BP in males, but they did not show any correlation in females. There was no consistent findings between nutrient intake and BP level. However, protein intake correlated positively with diastolic BP level in males. 4. Blood pressure change was positively associated with changes in BMI and serum total cholesterol in both sexes. Change in creatinine was associated with BP change positively in males and negatively in females. Students whose sodium intake was high showed higher systolic and diastolic BP in males, and students whose total fat intake was high maintained lower level of BP in females. The major determinants on BP change was BMI in both sexes.

  • PDF