• Title/Summary/Keyword: Mean low flow

Search Result 450, Processing Time 0.023 seconds

Development of Swirl Disc Nozzles for Knapsack Sprayers (배부식 방제기를 위한 디스크형 노즐 개발)

  • Gwak H.H.;Kim Y.J.;Rhee J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.153-160
    • /
    • 2006
  • This study was performed to evaluate some geometrical characteristics of disc type swirl nozzles and to develop nozzles having improved spraying performance for knapsack sprayers. Considered geometrical characteristics of the nozzles were disc thickness, orifice diameter, swirl chamber diameter and shape of the swirl chamber (nozzle chamber). 3 types of nozzle cores were compared. Main results of this study were as follows. 1. Spraying angle (A) was increased with decreasing disc thickness (x), and with increasing orifice diameter (y) or spraying pressure (z). The equation was as a follow. $$A=3.95\frac{1}{x}+73.50\sqrt{y}+18.97\sqrt{z}-60.16$$ 2. Spraying flow rate (F) was increased with decreasing disc thickness (x), and with increasing orifice diameter (y) or spraying pressure (z). The equation was as a follow. $$F=-89.95x+611.09y+620.49\sqrt{z}-868.20$$ 3. Mean spraying droplet size (V) was decreased with decreasing disc thickness (x), with increasing orifice diameter (y) in low spraying pressure, with decreasing orifice diameter (y) in high spraying pressure, and with increasing spraying pressure (z). $$V=148.77x^4-746.85x^3+1311.76x^2-917.31x$$ 4. The spray pattern was compared using CV values. The CV value of the nozzle core type 1 was 26.7% in spraying pressure $3\;kgf/cm^2$, the CV value of the core type 2 was 23.6% in spraying pressure $2\;kgf/cm^2$, the CV value of the core type 3 was 20.6% in spraying pressure $1\;kgf/cm^2$. 5. Minimum spraying pressure was improved from $1.5\;kgf/cm^2\;to\;1.0\;kgf/cm^2$ by changes of nozzle core shape.

A Novel Water Surface Detection Method Based on Correlation Analysis for Rectangular Control Area (직사각형 검사영역의 상관도 분석을 통한 수면위치 탐색 방법)

  • Lee, Chan Joo;Seo, Myoung Bae;Kim, Dong Gu;Kwon, Sung Il
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.12
    • /
    • pp.1227-1241
    • /
    • 2012
  • In this study, a novel water surface detection method was proposed. In the method water surface is detected by analysis on correlation coefficients obtained from rectangular control areas of the same vertical position in two successive images including both water surface and staff gauge. Four methods respectively based on threshold, peak, slope and variance ratio, are used to identify water surface from vertical distribution of correlation coefficient. In addition, swaying correction algorithm and statistical filtering are applied to minimize outliers caused by positional image mismatch. Images taken from 28 different sites during low flow were tested to evaluate the method. Mean relative error to eye measurement was approximately from 3.4 to 5.7 cm. As long as water surface moves, this method can be used to improve image stage gauge by supplementing the previous water surface detection method.

Spatial Characterization of Water Pollution in the Urban Stream Watershed (Gap Stream), Korea (도시하천(갑천) 유역에서 수질오염의 공간적 특성)

  • Lee, Heung-Soo;Hur, Jin;Jeong, Seon-A;Hwang, Soon-Jin;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.943-951
    • /
    • 2006
  • Spatial distribution of water pollution in the Gap Stream was investigated from October to November, 2005. Sampling was conducted three times including effluents discharged from a wastewater treatment plant (WWTP) and a dam reservoir during the low-flow period. As a typical urban stream, total nitrogen and inorganic nitrogen concentrations increased toward downstream. Ammonia concentration was the highest in the treated water of the wastewater treatment plant and the lowest nitrate concentration was found in the effluent of the dam reservoir. A part of soluble reactive phosphorous (SRP) in total phosphorous was 22~54% in the upstream reach of WWTP in the Gap Stream whereas 68~73% in the downstream reach. Mean chlorophyll-a concentration ranged from 1.6 to $11.0{\mu}g/L$ and it tends to increase toward downstream except for WWTP effluent. As expected, untreated wastewater and WWTP effluent were suggested as the major sources of water pollution in the Gap Stream. In this study, the water pollution of the Gap Stream is a significant undergoing typical eutrophication, caused by excessive phosphorus and nitrogen nutrients from WWTP located in the watershed. As a result, the critical factor for the water pollution was evaluated to dissolved inorganic nitrogen and phosphorus nutrients. Particularly, SRP is a most important for the eutrophication. It suggest that may occur in the most urban streams of Korean peninsula. Therefore, because the necessity of water pollution management in the urban stream, inorganic N and P nutrients should be included as an essential component of water quality criteria in the advanced water quality project of Korean Government by enforcing of water quality assessment and total maximum daily loads (TMDLs).

Simultaneous Determination of Haloperidol and Its Metabolite, Reduced Haloperidol, in Plasma by Gas Chromatography Using Nitrogen Phosphorous Selective Detection (Gas Chromatography-Nitrogen Phosphorous Selective Detection을 이용한 혈장중 Haloperidol 및 대사체인 Reduced Haloperidol의 동시정량)

  • Park, Kyoung-Ho;Lee, Min-Hwa;Shim, Chang-Koo;Lee, Myung-Gull;Park, Jong-Sei
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.3
    • /
    • pp.197-204
    • /
    • 1992
  • A gas chromatographic method using nitrogen phosphorous selective detection was developed for simultaneous determination of haloperidol and its metabolite, reduced haloperidol, in human plasma. Combelen was used as internal standard, The method involved extraction and trimethylsilylation followed by the injection of $2-4\;{\mu}l$ of benzene layer, which was used to dissolve the trimethylsilylated derivatives of haloperidol and reduced haloperidol, onto SE-54 column [5% phenyl methyl silica fused capillary column, $16m{\times}0.22\;mm$ $(I.D.){\times}0.33\;{\mu}m$ (coated thickness)]. The temperature of column oven was programmed from $200^{\circ}C\;to\;300^{\circ}C$ at the increase rate of $10^{\circ}C/min and also the temperatures of injector and detector were set at $300^{\circ}C$. Helium was used as carrier gas and its flow rate was maintained at 30 ml/min. The detection was conducted with nitrogen phosphorous selective detector. The retention times for combelen, reduced haloperidol and haloperidol were found to be 9.14, 9.75 and 9.99 min, respectively. The detection limits for haloperidol and reduced haloperidol in human plasma were both 0.2 ng/ml. The coefficients of variation of the intra-assay were generally low (below 9.8%). The mean absolute recoveries of added haloperidol and reduced haloperidol from plasma were 72% and 84%, respectively. No interferences from endogenous substances were found.

  • PDF

Population Genetic Structure of Potentilla discolor Bunge, Rosaceae in Korea (한국내 솜양지꽃의 집단 유전 구조)

  • Huh, Man-Kyu
    • Journal of Life Science
    • /
    • v.16 no.6
    • /
    • pp.898-903
    • /
    • 2006
  • The genetic diversity and population structure of fifteen Potentilla discolor Bunge populations in Korea were determined using genetic variations at 19 allozyme loci. Fourteen of the 19 loci (73.7%) showed detectable polymorphism. Genetic diversity at the species level and at the population level was high ($H_{ES}\;=\;0.215$, $H_{EP}\;=\;0.196$, respectively), whereas the extent of the population divergence was relatively low $(G_{ST}\;=\;0.069)$. Total genetic diversity values $(H_T)$ varied between 0.0 and 0.656, giving an average overall polymorphic loci of 0.292. The interlocus variation of genetic diversity within populations $(H_S)$ was high (0.274). On a per locus basis, the proportion of total genetic variation due to differences among populations $(G_{ST})$ ranged from 0.010 for Pgm-2 to 0.261 for Pgd-2 with a mean of 0.069, indicating that about 6.9% of the total allozyme variation was among populations. Wide geographic ranges, perennial herbaceous nature and the persistence of multiple generations are associated with the high level of genetic variation in P. discolor. The estimate of gene flow based on $G_{ST}$ was high among Korean populations of P. discolor (Nm = 3.36).

Study on Evaporation Heat Transfer of R-l34a, R-407C, and R-410A in the Oblong Shell and Plate Heat Exchanger (오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 증발 열전달에 관한 실험적 연구)

  • 박재홍;김영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.845-854
    • /
    • 2004
  • The evaporation heat transfer coefficient for R-l34a, R-407C (a mixture of 23wt% R-32, 25 wt% R-125, and 52 wt% R-l34a) and R-410A (a mixture of 50 wt% R-32 and 50 wt% R-125) flowing in the oblong shell and plate heat exchanger were investigated experimentally in this study. Four vertical counterflow channels were formed in the exchanger by four plates of commercial geometry with a corrugated sinusoid shape of a chevron angle of 45 degree. The effects of the mean vapor quality, mass flux, heat flux, and saturation temperature of different refrigerants on the evaporation heat transfer were explored in detail. Similar to the case of a Plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. It is found that the evaporation heat transfer coefficient in the plates is much higher than that in circular pipes. The present data show that the evaporation heat transfer coefficients of all refrigerants increase with the vapor quality. At a higher mass flux h, is higher than for the entire range of the vapor quality. Raising the imposed wall heat flux was found to slightly improve h$_{r}$, while h$_{r}$ is found to be lower at a higher refrigerant saturation temperature. A comparison of the performance of the various refrigerants reveals that R-410A has the highest heat transfer performance followed by R-l34a, and R-407C had the lowest performance of the refrigerants tested. Based on the present data, empirical correlations of the evaporation heat transfer coefficient were proposed.sed.

Genetic Diversity and Population Structure of Potentilla freyniana in Korea (한국내 세잎양지꽃의 유전적 다양성과 집단구조)

  • Huh, Man-Kyu
    • Journal of Life Science
    • /
    • v.17 no.7 s.87
    • /
    • pp.877-881
    • /
    • 2007
  • The genetic diversity and population structure of Potentilla freyniana in Korea were determined using genetic variations at 19 allozyme loci. Thirteen of the 19 loci (68.4%) showed detectable polymorphism. Genetic diversity at the population level was high ($H_{EP}$ = 0.270). Total genetic diversity values ($H_T$) varied between 0.190 and 0.584, giving an average overall polymorphic loci of 0.371. The interlocus variation of genetic diversity within populations ($H_S$) was high (0.354). On a per locus basis, the proportion of total genetic variation due to differences among populations ($G_{ST}$) ranged from 0.008 for Fe-2 to 0.310 for Gpi with a mean of 0.065, indicating that about 6.5% of the total allozyme variation was among populations. Wide geographic ranges, perennial herbaceous nature and the persistence of multiple generations are associated with the high level of genetic variation in P. freyniana. The estimate of gene flow based on $G_{ST}$, was high among Korean populations of P. freyniana (Nm =3.57). Although P. freyniana usually propagated by asexually-produced ramets, I could not rule out the possibility that sexual reproduction occurred at a low rate because each ramet may produce terminal flowers.

A Study on Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon with a Low Tilt Angle (낮은 경사각을 갖는 밀폐형 2상 열사이폰의 열전달 특성에 관한 연구)

  • 김철주;강환국;김윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • In lots of application to heat exchanger systems, closed two-phase thermosyphons are tilted from a horizontal. If the tilt angle, especially, is less than 30$^{\circ}$, the operational performances of thermosyphon are highly dependent on tilt angle. The present study was conducted to better understand such operational behaviors as mech-anni는 of phase change, and flow patterns inside a tilted thermosyphon. For experiment, an ethanol thermosyphon with a 35% of fill charge rate was designed and manufactured, using a copper tube with a diameter 19mm and a length 1500mm. Through a series of test, the tilt angle was kept constant at each of 4 different values in the range 10~25deg. and the heat supply to the evaporator was stepwisely increased up to 30㎾/$m^2$. When a steady state was established to the thermosyphon for each step of thermal loads, the wall temperature distribution and vapor temperature at the condenser were measured. The wall temperature distributions demonstrated a formation of dry patch in the top end zone of the evaporator, with a values of temperature 20~4$0^{\circ}C$ higher than the wetted surface for a moderate heat flux q≒20㎾/$m^2$. Inspite of the presence of hot dry patch, however, the mean values of boiling heat transfer coefficient at the evaporator wall were still in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times higher than the predicted values obtained from Nusselt's film condensation theory on tilted plate. Using those two expressions, a correlation was formulated as a function of heat flux and tilt angle, to determine the total thermal resistance of a tilted thermosyphon. The correlation formula showed a good agreement with the experimental data within 20%.

  • PDF

Assessment of genetic diversity of Prangos fedtschenkoi (Apiaceae) and its conservation status based on ISSR markers

  • Mustafina, Feruza U.;Kim, Eun Hye;Son, Sung-Won;Turginov, Orzimat T.;Chang, Kae Sun;Choi, Kyung
    • Korean Journal of Plant Taxonomy
    • /
    • v.47 no.1
    • /
    • pp.11-22
    • /
    • 2017
  • Prangos fedtschenkoi (Regel et Schmalh.) Korovin (Apiaceae) is an endemic species for mountainous Middle Asia, which is both a rare and useful plant. Organic extractions from this species are being used in pharmaceutics and cosmetology. In recent years, P. fedtschenkoi distribution area has considerably decreased, presumably, resulting from human activities such as agriculture, construction works, overgrazing and collection from wild for pharmaceutic purposes. Six populations were found in Uzbekistan and their genetic divergence and differentiation were studied with 10 inter-simple sequence repeat (ISSR) markers, selected out of 101. Totally 166 amplified ISSR fragments (loci) were revealed, of which 164 were polymorphic. Relatively moderate level of polymorphism was found at population level with polymorphic bands ranging from 27.71% to 47.59%. Mean P = 39.05%, $N_a=1.40$, $N_e=1.25$, S.I. = 0.21, and $H_e=0.14$ were revealed for all loci across six populations. AMOVA showed higher variation among populations (62%) than within them (38%). The Bayesian model determined 5 clusters, or genetic groups. The posteriori distribution of the Theta II estimator detected full model identifying high inbreeding, intensified by low gene flow (Nm = 0.3954). Mantel test confined population 6 as distinct cluster corresponding to geographic remoteness (R = 0.5137, $p{\leq}0.005$). Results were used as the bases for developing conserve measures to restore populations.

Production & Performance Assessment of Composite Material Flexible Propeller (복합재료 유연 프로펠러의 제작 및 성능 평가)

  • Lee, Sang-Gab;Byun, Joon-Hyung;Paik, Bu-Geun;Hyun, Beom-Soo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.6
    • /
    • pp.667-674
    • /
    • 2009
  • The researches on the development of composite material underwater vehicle propeller have been actively attempted for the reduction of radiation noise with outstanding damping effects. Composite material propellers have almost been designed and produced by the foreign experts, and it is difficult to obtain the related informations about their flow, vibration, material characteristics because they are treated as the secrets with close relationship to the military technology, especially in the case of underwater vehicles. For the security of domestic manufacture of composite material propeller and the comparison and examination of its performance and radiation noise characteristics with those of German CONTUR composite material propeller, two propellers were self-produced according to the fiber weaving and array using compressible molding process and their self performances and radiation noise characteristics were measured. The mean fluctuations of blade tip of self-produced composite material propeller were increased and the radiation noises in the low frequency band were reduced compared to those of CONTUR, which could be estimated as the change of material characteristics and also be thought to be used for the future research informations.