• Title/Summary/Keyword: Mean frequency

Search Result 4,521, Processing Time 0.03 seconds

A Study on the Sleep/Activity pattern in Normal Early Infants using NCASA (Nursing Child Assessment Sleep/Activity Record) (NCASA(Nursing Child Assessment Sleep/Activity Record)를 이용한 초기 영아의 수면/활동 양상 연구)

  • Park, Hae-Sun;Lee, Yeong-Eun
    • Korean Parent-Child Health Journal
    • /
    • v.3 no.1
    • /
    • pp.46-59
    • /
    • 2000
  • The purpose of this study is to determine whether the NCASA (Nursing Child Assessment Sleep/Activity Record) would be suitable to evaluate and to provide the basic resources for a Korean model of sleep/activity patterns during the first 6 months Korean infants' lives and to provide a basis for nursing intervention for mothers of early infants. The subjects of this study were 94 normal infants from birth to 6 months of age who visited the postpartum care center and two general hospitals located in Pusan from February 1 to April 28, 2000. The method of data collection was through convenient sampling. The instrument of this study was the NCASA translated by the Korean parent Child Health Academic Association. The collected data were analysed by mean, standard deviation, frequency percentage and ANOVA, Post Hoc test by use of SPSS/PC. The conclusions obtained from this study are summarized as follows: 1. The mean amount of daytime sleep was 8.06 hours. The mean amount of nighttime sleep was 6.31 hours. The mean amount of total daily sleep was 14.37 hours. The mean of the longest sleep period was 5.20 hours. The mean regularity of daytime sleep was 25.84%. The mean regularity of nighttime sleep was 77.69%. The mean regularity of total daily sleep was 42.60%. The mean frequency of nighttime wakenings was 2.33 times. 2. The mean amount of daytime activity was 8.25 hours. The mean amount of nighttime activity was 1.39 hours. The mean amount of daily total activity was 9.64 hours. The mean of the longest activity period was 3.80 hours The mean frequency of daytime feeding was 5.69 times. The mean frequency of nighttime feeding was 2.08 times. The mean frequency of total daily feeding was 7.74 times. The mean frequency regularity of feeding was 54.62%. The mean frequency of wakenings was 5.14 times. The mean frequency of crying was 1.90 times. 3. According to an analysis of sleep patterns based on an infant's age, there were some significant differences in the following factors: amount of daytime sleep(p<.001), amount of night time sleep(p<.05), amount of total daily sleep (p<.001), longest sleep period(p<.001), regularity of daytime sleep(p<.001), regularity of nighttime sleep(p<.01), regularity of total daily sleep(p<.001), frequency of nighttime wakenings(p<.001). 4. According to an analysis of activity patterns based on an infant's age, there were some significant differences in the following factors: amount of daytime activity(p<.001), amount of nighttime activity(p<.01), amount of total daily activity(p<.001), longest activity period(p<.05), frequency of nighttime feeding(p<.01), frequency of wakenings(p<.001). 5. The mean amount of a mother's day time was 16.30 hours. The mean amount of a mother's night time was 7.70 hours. In conclusion, the initial irregular sleeping and activity patterns of the early infant became regurized as the infant grew older and estabilished firmer patterns of sleeping and of activity.

  • PDF

Relationship between Endurance Times and Frequency Parameters in Surface EMG during Isotonic Contraction Exercises (등장성 수축운동시 표피근전도의 주파수파라미터와 근지구력시간과의 상관성)

  • Lee, Sangsik;Go, Jaewook;Jang, Jeehun;Park, Wonyeop;Lee, Kiyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.135-140
    • /
    • 2012
  • Previous investigators have shown that the frequency compression is related to the muscle fatigue and the decreasing conduction velocity of muscle fibers. The aim of the present study was to investigate the relationship between endurance times and frequency parameters such as mean power frequency and median frequency in the surface EMG signal during isotonic contractions. Eight healthy subjects performed voluntary isotonic contractions of biceps Brachii muscle until their endurance times which were determined when the subject could no longer follow the contraction cycle. The regressive slopes of mean power frequency and median frequency were used to describe the frequency compression of the surface EMG signal, and to test the predictability of endurance time. As results of experiment, significant correlations were found between endurance time and the regressive slopes of mean power frequency and mean frequency computed over 50%Tend of endurance time.

A New Mean Frequency Extension Method in Doppler System (초음파 도플러 시스템에서 새로운 평균 주파수 확장 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.183-190
    • /
    • 1995
  • The use of ultrasound pulsed Doppler systems has become increasingly popular due to the advantages of easy measurements of blood velocity, volume blood blow, and irregularities of the circulatory system. However, the 2-D Doppler systems have several problems, such as range ambiguity, low signal to noise ratio, and slow frame rate. The mean frequency aliasing problem originating from the pulse repetition frequency is one of major limitations in pulsed Doppler systems. A conventional approach to resolve this problem is tracking the mean frequency close to and beyond the Nyquist frequency along the temporal axis. In this paper, a new concept of tracking the mean frequency along the spatial axis is proposed. The proposed technique is fault tolerant by nature and more suitable for multi gate and 2-D Doppler system than conventional methods.

  • PDF

A Study on the Sleep/Activity pattern in New Born Baby (신생아의 수면/활동 양상에 관한 연구)

  • Lee, Yung-Eun;Lee, Hwa-Ja;Kim, Young-Hae;Baek, Kyung-Sun;Jung, Haang-Mee;Park, Hae-Sun
    • Korean Parent-Child Health Journal
    • /
    • v.3 no.1
    • /
    • pp.60-72
    • /
    • 2000
  • Studies are needed to determine the standard norms for sleep/activity patterns in new born baby and there have been no established reports of discrepancy of sleep/activity patterns in new born baby among various races. The purpose of this study is to determine whether the NCASA(Nursing Child Assessment Sleep Activity Record) would be suitable to evaluate and to provide the basic resources for a Korean model of sleep/activity patterns during the new born baby, and to provide a basis for nursing intervention for mothers of new born baby. The subjects of this study were 38 normal new born baby who visited the postpartum care center and two general hospitals located in pusan from January 1 to April 28, 2000. They all agreed to participate in this study. The method of data collection was through convenient sampling. Data were collected through questionnaires including demographic data, birth hi story, and general informations concerning the infant, mother and family. The instrument of this study was the NCASA translated by the Korean parent Child Health Academic Association. The collected data were analysed by mean. standard deviation, frequency, and percentage by use of SPSS/PC. The conclusions obtained from this study are summarized as follows: 1. The mean amount of daytime sleep was 10.23 hours. The mean amount of nighttime sleep was 5.53 hours. The mean amount of total daily sleep was 15.77 hours. The mean of the longest sleep period was 4.49 hours. The mean regularity of daytime sleep was 49.69%. The mean regularity of nighttime sleep was 66.98%. The mean regularity of total daily sleep was 55.81%. The mean frequency of nighttime wakenings was 3.09 times. 2. The mean amount of daytime awake periods was 6.12 hours. The mean amount of nighttime awake periods was 2.11 hours. The mean amount of daily total awake periods was 8.23 hours. The mean of the longest awake periods was 3.76 hours. 3. The mean frequency of daytime feeding was 5.71 times. The mean frequency of nighttime feeding was 2.65 times. The mean frequency of total daily feeding was 8.36 times. The mean frequency regularity of feeding was 62.50%. 4. The mean amount of a mother's day time was 16.36 hours. The mean amount of a mother's night time was 7.64 hours. In conclusion, The new born baby slept more during the daytime compare than nighttime and more active during the daytime. On the other hand. although nighttime sleeping the length of the mother was normal, but sleep was interrupted by the infant over 3 times on average. Therefore this research study will contribute to nursing practice and nursing research by its implication through postnatal educational nursing programs at hospital and nursing intervention programs that would help individual caring of early infant mothers at home.

  • PDF

NUMERICAL STUDY OF MODULATED TAYLOR-COUETTE FLOW (진동하는 Taylor-Couette 유동에 대한 수치적 연구)

  • Kang, Chang-Woo;Yang, Kyung-Soo;Mutabazi, Innocent
    • Journal of computational fluids engineering
    • /
    • v.15 no.4
    • /
    • pp.32-39
    • /
    • 2010
  • In this study, we consider Taylor-Couette flow with the outer cylinder at rest and the inner one oscillating with a mean angular velocity. Varying the mean angular velocity, amplitude and frequency of the oscillation, we investigate the characteristics of modulated Taylor vortices. At a constant mean angular velocity, Taylor vortices intensify as the amplitude increases and frequency decreases. The axial wavenumber is calculated by spectral analysis. When the frequency varies, the axial wavenumber does not change at a constant mean angular velocity and amplitude. But, the axial wavenumber increases, as the mean angular velocity increases.

Least Mean Square Estimator for Motor Frequency Measurement Based on Linear Hall Sensor (선형 홀센서 기반의 모터 회전속도 측정을 위한 평균 최소 자승 추정기)

  • Choi, Ga-Hyoung;Ra, Won-Sang;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.866-874
    • /
    • 2008
  • Motor frequency can be measured by a hall sensor. Among the many hall sensors, a linear type hall sensor is good at high accuracy frequency measuring problem. However, in general, this linear type hall sensor has DC offset which can vary along sensor's operating voltage change. Therefore, In motor frequency measurement problem using the linear hall sensor, it needs an estimator that can estimate frequency and DC offset simultaneously. In this paper, we propose the least mean square estimator to estimate motor frequency. To verify its performance, we compare the LMS estimator with a commercial analog tachometer. Experimental results shows the proposed LMS estimator works well in varying frequency and stationary DC offset.

Relationship Between the Mean and Median in a Skewed Frequency Distribution

  • Shin, Mi-Young;Cho, Tae Kyoung
    • Communications for Statistical Applications and Methods
    • /
    • v.11 no.3
    • /
    • pp.513-518
    • /
    • 2004
  • The well-known mode-mean-median inequality for the unimodal population distribution does not always hold for the frequency distribution. But many elementary statistics text books just mention that the relative location of the mean and median can be used to determine whether a distribution is positively or negatively skewed. In this paper we introduce the method generating data that is positively skewed but mean

Predicting Personal Credit Rating with Incomplete Data Sets Using Frequency Matrix technique (Frequency Matrix 기법을 이용한 결측치 자료로부터의 개인신용예측)

  • Bae, Jae-Kwon;Kim, Jin-Hwa;Hwang, Kook-Jae
    • Journal of Information Technology Applications and Management
    • /
    • v.13 no.4
    • /
    • pp.273-290
    • /
    • 2006
  • This study suggests a frequency matrix technique to predict personal credit rate more efficiently using incomplete data sets. At first this study test on multiple discriminant analysis and logistic regression analysis for predicting personal credit rate with incomplete data sets. Missing values are predicted with mean imputation method and regression imputation method here. An artificial neural network and frequency matrix technique are also tested on their performance in predicting personal credit rating. A data set of 8,234 customers in 2004 on personal credit information of Bank A are collected for the test. The performance of frequency matrix technique is compared with that of other methods. The results from the experiments show that the performance of frequency matrix technique is superior to that of all other models such as MDA-mean, Logit-mean, MDA-regression, Logit-regression, and artificial neural networks.

  • PDF

A study on the Sleep/Activity pattern of normal neonate in Kangwon area (강원도 지역 신생아 수면/활동 양상에 관한 연구)

  • Kwon, Mi-Kyung;Lee, Kyung-Min;Choi, Seon-Jeong;Choi, Sang-Soon
    • Korean Parent-Child Health Journal
    • /
    • v.3 no.2
    • /
    • pp.18-24
    • /
    • 2000
  • The purpose of this research is to investigate Sleep/Activity pattern of normal neonate in Kangwon area. The subjects of this research were 23 normal neonate who visited pediatric clinic of kangneung general hospital from Jun 15, 1999 to August 10, 2000. The instrument of this research was the NCASA. The results of this research were as follows: 1. The mean time of daytime sleep was 8.21 hours. The mean time of nighttime sleep was 5.70 hours. The mean time of total daily sleep was 13.92 hours. The mean time of longest sleep period was 5.02 hours. The mean time of regularity of sleep were daytime 46.59%, nighttime 74.43%, total daily sleep 55.88%. The mean frequency of nighttime wakening was 2.03 times. 2. The each mean time of activity were daytime 7.72 hours, nighttime 2.28 hours, daily total activity 9.99 hours. The mean time of the longest activity period was 6.16 hours. The mean times of feeding frequency were daytime feeding 4.53, nighttime feeding 1.92, total daily feeding 6.45. The mean of regularity of feeding frequency was 65.71%.

  • PDF

Incomplete Relationship between Dominant Power of Electrogastrography and Gastric Myoelectrical Activity in Patients with Functional Dyspepsia

  • Han, Sook-Young;Yoon, Sang-Hyub;Kim, Jin-Sung;Rhyu, Bong-Ha;Rhyu, Ki-Won
    • The Journal of Korean Medicine
    • /
    • v.24 no.4
    • /
    • pp.92-101
    • /
    • 2003
  • Background & Aims : The aim of this study was to investigate the change of dominant power with observation of gastric myoelectrical activity and its parameter linkage in electrogastrography. Methods : Electrogastrography was performed on a total of 123 subjects (113 patients with functional dyspepsia, 10 healthy controls) for 30 min in fasting state and 50 min in postprandial state. Average myoelectrical activity per frequency and accumulated electrical activity of 5 min duration in each bradygastria, normogastria, and tachygastria were measured at the moment of frequency switchover of slow wave. Assumed parameter linkages were also investigated among dominant frequency, % of normal regularity, and dominant power (or power ratio). Results : Average myoelectrical activity per frequency was highest in bradygastria (mean 1.10-1.47 Volt/s), next highest in normogastria (mean 0.50-0.82 Volt/s), and lowest in tachygastria (mean 0.44-0.47 Volt/s). Average accumulated myoelectrical activity was highest in normogastria (mean 114.90-126.29 Volt/ss), next highest in tachygastria (mean 71.02-90.00 Volt/ss), and lowest in bradygastria (mean 12.93-51.94 Volt/ss). Significance of parameter linkages were noted in dominant frequency (p< 0.01) and in % of normal regularity (p< 0.01), but not in dominant power in case of frequency shift from bradygastria to normogastria (p=0.376). Conclusion : Dominant power is not a parameter that reflects the gastric myoelectrical activity related with only gastric contraction. Bradygastric dominant power does not follow the inter-parameter linkage of electrogastrography for gastric motility assessment.

  • PDF