• Title/Summary/Keyword: Mean drop size

Search Result 86, Processing Time 0.026 seconds

Development and Basic Performance Characterization of Neutralized Fabric Filter (제전사여과포의 개발 및 기초성능 규명)

  • 박영옥;구철오;임정환;김홍룡;손재익;이영우
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.57-64
    • /
    • 1998
  • A neutralized fabric filter of which major raw materials were polyester and stainless steel fibers was developed and its physiochemical properties and basic filter characteristics were investigated. Four finds of dusts generated in the typical domestic industry were used, which were coke dust from a steel manufacturing process, cement dust from a cement manufacturing process, flu ash from a fluidized-bed combustor, and incinerator ash from a waste plastics incinerator. The physicochemical properties of the neutralized fabric filter were analyzed in terms of changes in tensile strength and initial elastic modulus under $SO_2$ and $NO_2$ atmospheres, mean flow pore pressure, bubble point pore diameter, mean flow pore diameter, and pore size distribution. In addition, the pressure drop, dust penetration, and figure of merit for the fabric filter were investigated in a bench-scale filter testing unit. The pressure drop increased as the filtration velocity and dust loading increased, and its increasing shape depended on the type of dust. The dust penetration rapidly decreased as the dust loading increased irrespective of the type of dust. The figures of merit for the fabric filters increased in the early stage of filtration and then showed rapid decreases followed maintaining a constant level.

  • PDF

An Experiment on Particle Collection and Gas Removal in a 2-Stage Electrostatic Wet Scrubber (2단 정전식 세정집진기의 집진 및 가스제거 특성)

  • Yeo, Kuk-Hyun;Yoo, Kyung-Hoon;Son, Seung-Woo;Kim, Yoon-Shin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.745-752
    • /
    • 2006
  • DOS and NaCl aerosol particles were used to determine collection efficiencies of a 2-stage electrostatic wet scrubber with respect to particle size. The DOS and NaCl aerosols have geometric mean diameters of 0.1-3.0 urn, geometric standard deviations of $1.1{\sim}1.8$ and total number concentrations of $450{\sim}2,400\;particles/cm^3$. The tested operating variables for the electrostatic wet scrubber included air velocity and water injection rate. It was shown from the experimental results that particle collection efficiencies increased in the submicron particle size range when different polarities were applied on the water nozzle and corona wire, respectively. This increase in the collection efficiency is attributed to strong electrostatic attraction between the negative water droplets and positive submicron particles. The collection efficiencies also increased when water injection rate was increased or air velocity was decreased. Meanwhile, the pressure drop across the wet scrubber decreased by 90% compared with the existing mechanical wet scrubber. Finally, ammonia gas was used to determine gas removal efficiencies. It was observed that the gas removal efficiencies increased when the air velocity was decreased or the water injection rate was increased.

An Experimental Study on the Characteristic of Sprays and Spray Flames by Twin-Fluid Atomizer (2유체 분사노즐을 이용한 분무 및 연소특성에 관한 실험적 연구)

  • 백민수;오상헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.548-558
    • /
    • 1995
  • An experimental investigation has been conducted to study the spray and combustion characteristics using the air-assisted twin fluid atomizer. Axial mean and fluctuating velocity components as well as drop-size distributions in non-reaction spray were measured with a nonintrusive phase doppler technique. Droplet number density distributions were also visualized using high speed CCD camera. Locations of spray and flame boundaries are obtained by direct photographic method. It is confirmed that at the fixed fuel flow rate, the increase of the atomizing air flow causes improvements on both spray and combustion characteristics under stable flame conditions. Internal group combustion modes where flame is located inside the spray boundary are observed to exist in the upstream region of higher droplet number density.

Analysis of Turbulent Gas-Particle Suspension Flows in a Venturi (固體粒子 가 浮上된 벤츄리管 流動 의 解析)

  • 성형진;정명균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.133-140
    • /
    • 1984
  • A "two-fluid" equation model has been applied for predicting gas-solid suspension flows through a Venturi tube. In the "two-fluid"equation model, the bulk motion of the particles is considered as a continuum whose governing equation is obtained by averaging the conservation equations over a volume and expressing the equations in differential forms. Closure of the time-mean equations is achieved by modeling the turbulent correlations with an extended mixing-length theory. Proposed closure model is found to aptly simulate the dependency of the static pressure drop on the particle size, flow rate and the loading ratio.d the loading ratio.

The Effect of Bluff-Body Shapes on the Drop Size and Flame Temperature (Bluff-Body형상이 연료액적크기와 화염온도에 미치는 영향)

  • Hwang, Sang-Ho;Cha, Keun-Jong;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.937-942
    • /
    • 2000
  • The characteristics of spray combustion and dropsize of spray through twin-fluid atomizer was experimentally investigated. The distribution of flame temperature have an effect on the generation of NOx. To investigate there effects, flame temperature with different spray shape was observed. The spray shape was varied by various bluff-bodys. Mean temperature were measured by thermocouple respectively, and NOx concentration was measure by NOx analyser. Distribution of droplet sizes were measured by PMAS. The result showed that the flame with wide distribution has lower temperature and lower NOx emission compared with narrow.

  • PDF

An Experimental Study on the Drop Distribution and the Combustion Characteristics with different Bluff-body Geometries (보염기 형상에 따른 연료액적분포와 연소특성에 관한 실험적 연구)

  • Hwang, S.H.;Kim, D.J.
    • Journal of ILASS-Korea
    • /
    • v.9 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • This work was performed to investigate the distribution of the fuel droplet size around the bluff-body and the combustion characteristics. The geometry of the bluff-body influenced the spray shape and the combustion characteristics. Diameters of the bluff-body in this experiment are 6, 8, and 10 mm and the impingement $angles({\theta})\;are\;30^{\circ},\;60^{\circ},\;and\;90^{\circ}$. The measurement points were at the distances of 20 and 30 mm axially from the nozzle. The SMD and Rosin-Rammler distribution was acquired by image processing technique (PMAS), and the mean temperatures were measured by thermocouple. The results obtained are as follows; In the condition of ${\theta}=60^{\circ}$, the values of SMD are not greatly varied compared to the other conditions. As the impingement angle of bluff-body was increased, the high temperature region was wider along radial direction. When the air-fuel ratio was increased, the CO concentration was decreased.

  • PDF

The Effect of Viscosity on the Spray Characteristics of Pressure Swirl Atomizer (스월분무특성에 미치는 점성의 영향)

  • Yoon, S.J.;Cho, D.J.
    • Journal of ILASS-Korea
    • /
    • v.4 no.4
    • /
    • pp.24-29
    • /
    • 1999
  • In the pressure swirl atomizer, the liquid is injected through tangential passages into a swirl chamber, from which it emerges with both tangential and axial velocity components to form a thin conical sheet at the nozzle exit. This sheet rapidly attenuates, finally disintegrating into ligaments and then drops. The purpose of this study is to measure the spray characteristics according to variation of viscosity of the spray produced by the pressure swirl atomizer. The nozzle tested here were especially designed for this investigation. The discharge coefficient is determined by measuring the volume flow rate with a flow meter and the cone angle of the liquid sheets issuing from the nozzle is obtained from series of photographs of the sheet for various liquid viscosity and injection pressure. And mean drop size is measured by image processing method. It is found that the geometrical characteristics of the nozzle and the variation of viscosity were the influential parameters to determine the spray characteristics such as the cone angle, discharge coefficients and SMD.

  • PDF

An Experiment on Particle Collection Characteristics of a Duct-type Wet Scrubber (덕트형 세정집진기의 입자포집 특성실험)

  • Yoo, Kyung-Hoon;Yeo, Kuk-Hyun;Son, Seung-Woo;Hwang, Kwang-Ho;Jung, Jin-Won;Kim, Yoon-Shin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1795-1800
    • /
    • 2004
  • DOS and NaCl aerosol particles with geometric mean diameter of $0.1{\sim}3.0{\mu}m$ geometric standard deviation of $1.1{\sim}1.8$ and total number concentration of $450{\sim}400$ $particles/cm^3$ were used to determine collection efficiencies of a duct-type wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. It was also seen that the collection efficiency of the Duct-type wet scrubber is mainly governed by the mechanism of inertial impaction.

  • PDF

An Experimental Study on the Superheated Liquid Jet (과열액체제트의 미립화에 관한 실험적 연구)

  • Lee J. G.;Lee S. Y.;Kim I. G.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.1
    • /
    • pp.89-102
    • /
    • 1987
  • Experiments have been carried out to study the atomisation characteristics of superheated liquid(water) jet injected into the atmosphere through a single-hole nozzle. In present experi-mental range, superheated liquid jet has been observed to be atomised in two-phase effluent type; that is, spray formed by the bubble nucleation in the nozzle. In case of liquid injection through a long nozzle (L/D=29.09), the critical superheat for occurrence of two-phase effluent atomisa-tion can be determined from sudden change of spray angle. Sauter mean diameter of the spray droplets decreases as the degree of superheat increases. For the short nozzle (L/D=7.27), mean diameter increases with the injection pressure, while it decreases for the long nozzle; however for the long nozzle the effect of injection pressure is not significant compared with the short nozzle. For the short nozzle the uniformity of drop size distribution increases with increasing the degree of superheat, but for the long nozzle the effect of superheat on the uniformity is not appreciable.

  • PDF

Source parameters of earthquakes occurred in the Korean Peninsula (한반도 발생 지진의 지진원 상수)

  • 김성균;김병철
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.3-11
    • /
    • 2002
  • Source parameters for forty nine recent earthquakes occurred in and around Korean Peninsula are determined and the relations among them are studied. The corner frequency and seismic moment are estimated from three different methods. The spectral fitting of the source displacement spectrum with the $\omega$-square source model of Brune(1970) and Snoke(1987)'s method are applied to all events and empirical Green's function method for two events are adopted. The source parameters determined in this study show different values depending on the adopted method and on the stations of which seismograms are recorded. It is interpreted that the disagreements principally originate from insufficient consideration of source radiation pattern and attenuation and amplification according to path direction. The corner frequencies and seismic moments are averaged to exclude the directional effects and other source parameters are estimated from the mean corner frequency and seismic moment. The static stress drops estimated in this study tend to be independent of seismic moment or magnitude for events above a certain size. For earthquakes with the size less than about 3.0$\times$10$^{21}$dyne-cm(nearly same as M$_{L}$=3.7), the stress drop tends to decrease with the decreasing moment. This fact suggests a breakdown of scaling law of source parameters below the threshold magnitude. The moment magnitudes calculated from source parameters appear to be slightly larger than the Richter's local magnitudes in the range above M$_{L}$=3.5.3.5.

  • PDF