• Title/Summary/Keyword: Mean Velocity

Search Result 2,120, Processing Time 0.03 seconds

Seasonal Variations of $SO_2$Dry Deposition Velocity Obtained by Sonic Anemometer-Thermometer (초음파 풍속온도계를 이용한 $SO_2$건성침착속도의 계절변화 특징)

  • 이종범;박세영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.465-478
    • /
    • 1998
  • In this study, seasonal variations of the dry deposition velocity and deposition flux for the sulfur dioxide were analysed. The field observation was performed during one year (from November 1, 1995 to October 31, 1996) in Chunchon basin. The turbulence data were measured by 3-dimensional sonic anemometer/thermometer, and were estimated by mean meteorological data obtained at two heights (2.5 m and 10 m) of meteorological tower. Also, the estimation methods were evaluated by comparing the turbulence data. The results showed that the estimated dry deposition velocity and turbulence parameter such as uc and sensible heat flux using mean meteorological data were relatively similar to the sonic measurements, but all showed somewhat large differences. The dry deposition velocity was large in summer and small in winter mainly due to canopy resistance (rc). The major factor which affects diurnal variation of the velocity was aerodynamic resistance (rw). The SO2 dry deposition flux was large in winter and small in summer in Chunchon.

  • PDF

Measurement of vertical migration speed of Sound Scattering Layer using an bottom mooring type Acoustic Doppler Current Profiler (해저설치형 음향도플러유향유속계를 이용한 음향산란층의 연직이동속도 측정)

  • Jo, Hyeon-Jeong;Lee, Kyoung-Hoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.449-457
    • /
    • 2010
  • This study shows that the vertical migration speed of sound scattering layers (SSLs), which is distributed in near Funka Bay, were measured by 3D velocity components acquired from a bottom moorng ADCP. While the bottom mooring type has a problem to measure the velocity vectors of sound scattering layer distributed near to surface, both the continuous vertical migration patterns and variability of backscatterers were routinely investigated as well. In addition, the velocity vectors were compared with the vertical migration velocity estimated from echograms of Mean Volume Backscattering Strength, and estimated to produce observational bias due to SSLs which is composed of backscatterers such as euphausiids, nekton, and fishes have swimming ability.

Numerical studies on non-shear and shear flows past a 5:1 rectangular cylinder

  • Zhou, Qiang;Cao, Shuyang;Zhou, Zhiyong
    • Wind and Structures
    • /
    • v.17 no.4
    • /
    • pp.379-397
    • /
    • 2013
  • Large Eddy Simulations (LES) were carried out to investigate the aerodynamic characteristics of a rectangular cylinder with side ratio B/D=5 at Reynolds number Re=22,000 (based on cylinder thickness). Particular attention was devoted to the effects of velocity shear in the oncoming flow. Time-averaged and unsteady flow patterns around the cylinder were studied to enhance understanding of the effects of velocity shear. The simulation results showed that the Strouhal number has no significant variation with oncoming velocity shear, while the peak fluctuation frequency of the drag coefficient becomes identical to that of the lift coefficient with increase in velocity shear. The intermittently-reattached flow that features the aerodynamics of the 5:1 rectangular cylinder in non-shear flow becomes more stably reattached on the high-velocity side, and more stably separated on the low-velocity side. Both the mean and fluctuating drag coefficients increase slightly with increase in velocity shear. The mean and fluctuating lift and moment coefficients increase almost linearly with velocity shear. Lift force acts from the high-velocity side to the low-velocity side, which is similar to that of a circular cylinder but opposite to that of a square cylinder under the same oncoming shear flow.

A Study on The Velocity Distribution in Closed Conduit by Using The Entropy Concept (엔트로피 개념을 이용한 관수로내의 유속분포에 관한 연구)

  • Choo, Tai Ho;Ok, Chi Youl;Kim, Jin Won;Maeng, Seung Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4B
    • /
    • pp.357-363
    • /
    • 2009
  • When yields the mean velocity of the closed conduit which is used generally, it is available to use Darcy Weisbach Friction Loss Head equation. But, it is inconvenient very because Friction Loss coefficient f is the function of Reynolds Number and Relative roughness (${\varepsilon}$/d). So, it is demanded more convenient equation to estimate. In order to prove the reliability and an accuracy of Chiu's velocity equation from the research which sees hereupon, proved agreement very well about measured velocity measurement data by using Laser velocimeter which is a non-insertion velocity measuring equipment from the closed conduit (Laser Doppler Velocimeter: LDV) and an insertion velocity measuring equipment and the Pitot tube which is a supersonic flow meter (Transit-Time Flowmeters). By proving theoretical linear-relation between maximum velocity and mean velocity in laboratory flume without increase and decrease of discharge, the equilibrium state of velocity in the closed conduit which reachs to equilibrium state corresponding to entropy parameter M value has a trend maintaining consistently this state. If entropy M value which is representing one section is determinated, mean velocity can be gotten only by measuring the velocity in the point appearing the maximum velocity. So, it has been proved to estimate simply discharge and it indicates that this method can be a theoretical way, which is the most important in the future, when designing, managing and operating the closed conduit.

Kinematic analysis of skill between flexed and extended type of knee during Jigeo-Cha-Gi in Taekwon-Do (태권도 찍어차기의 무릎편 유형과 구부린 유형의 운동학적 비교분석)

  • Kim, Dong-Kyu;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.25-42
    • /
    • 2005
  • The study was to investigate kinematic difference between flexed and extended type of knee during Jigeo-Cha-Gi in Taekwon-Do. For this subjects participated were consisted of weights of fin (1), bantam (1) and welter class(1) of male 3 national representative level skilled in two type(flexed and extended type) of Jigeo-Cha-Gi. 3D cinematography analysis was performed for motion analysis and Kwon 3D ver. 3.1) was used for 3D coordinates & analysis variables calculation. In Temporal variable there was no significant difference statistically in all phases & total elapsed time between flexed and extended type, but flexed type was delayed more 0.016 sec than extended type. In displacement of COG there was significant difference in level of p<.05 showing longer mean 6.13 cm in case of flexed type than extended type in displacement of COG during all phase and too significant difference in level of p<.01 showing longer mean 4.4 cm in case of flexed type than extended type in displacement of COG in follow through phase. In velocity of COG there was significant difference in level of p<.001 showing higher mean 15.53cm/s in case of flexed type than extended type in velocity of COG(Y direction) during targeting phase and peak velocity(Y) was more fast 8.74 cm/s in extended type than flexed type. In velocity of leading leg in forward direction(Y) there was significant difference in level of p<.05 showing higher thigh mean value in case of flexed type than extended type but showing higher foot mean value in extended type at level of p<.001 than flexed type in velocity of COG(Y direction). In velocity of leading leg in vertical direction(Z) there was no significant difference in the second & third phase in case of vertical velocity level, but momentum transferred efficiently form proximal to distal endpoint. In front-back & right-left orientation angle of trunk there was possibility of more stable Jigeo-Cha-Gi in extended than flexed type by decreasing in right-left orientation angle of trunk. In relative angle of lower leg(hip, knee, ankle) there was significant difference in level of p<.001 showing longer mean 32.74 deg. in case of flexed type than extended type in hip joint during the second phase but maintained insufficient extended knee of mean 168 deg. in targeting phase.

A study on the measurement and characterization of tubulent flow inside an engine cylinder (엔진 실린더내 난류유동 측정과 정량화방법에 관한 연구)

  • 강건용;엄종호;김용선
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.39-47
    • /
    • 1992
  • The engine combustion is one of the most important process affecting performance and emissions. One effective way to improve the engine combustion is to control motion of the charge inside a cylinder by means of optimum induction system design, because the flame speed is mainly determined by the turbulence in a gasoline engine. This paper describes the measurement and characterization of mean velocity and turbulence intensity inside the cylinder of a 4-valve gasoline engine using laser Doppler velocimeter(LDV) under motoring(non-firing) conditions. Since the measured LDV data in each cycle show small cycle variation during compression stroke in the tested engine, the mean velocity and turbulence intensity are calculated by ensemble averaging method neglecting cycle variation effects. In the ensemble averaging method, the effects of the calculation window, in which velocities are assumed as the same crank angle, on mean velocity and turbulence intensity are fully investigated. In addition, the effects of measuring point on the flow characteristics are studied. With large calculation window, the mean velocity is shown to be less sensitive with respect to crank angle and turbulence intensity decrease in its absolute amplitude. When the piston approch to the top dead center of compression, the turbulence intensity is found to be homogeneous in the cylinder.

  • PDF

The Droplet Size Distribution of Fan Spray at Different Surrounding Conditions (팬형분무의 주변조건에 따른 입자분포 변화)

  • Moon, Seok-Su;Choi, Jae-Joon;Bae, Choong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.7 s.262
    • /
    • pp.611-619
    • /
    • 2007
  • In this study, the droplet size distribution of a slit injector at different surrounding conditions, such as air flow and fuel temperature, were investigated. Phase Doppler anemometry (PDA) was utilized to investigate the initial droplet size distribution and the effect of fuel temperature and air flow on droplet size distribution. The entrained air motion was also evaluated by the temporal velocity profile of droplets. When the air flow velocity increased, the small droplets were more entrained to the upper and central parts of the spray and this tendency was confirmed by plotting the temporal velocity profile of droplets. This entrainment of small droplets at high airflow velocities caused relatively small mean droplet size at upper and central parts of the spray and the large mean droplet size at downstream and edge of the spray, compared to that of low airflow velocities. The total mean droplet size, obtained by averaging the size of all droplets measured at all test locations, decreased when the high airflow velocities were applied. The increased fuel temperature, with an airflow velocity of 10m/s, caused reduced droplet size at all test locations. However, the decreased value of mean droplet size at high fuel temperatures was relatively higher at upper parts of the spray, compared to downstream, as a result of enhanced entrainment of small droplets to upper parts of the spray.

A STUDY ON THE MANDIBULAR MOVEMENTS OF TMD PATIENTS (두개하악장애 환자의 하악운동에 관한 연구)

  • Heo, Seong-Joo;Kim, Kwang-Nam;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.103-119
    • /
    • 1994
  • The purpose of this study was to evaluate the mandibular movements of TMD patients comparing to normal persons. Sirognathograph was used to measure five parameters of mandibular movements of twenty normal persons and eight TMD patients. Five parameters were (1) Maximum opening during maximum opening and closing, (2) Mean velocity during maximum opening and closing, (3) Maximum opening during unilateral chewing, (4) Mean velocity during unilateral chewing, (5) Consistency of mandibular movement during unilateral chewing. Based on above results, new Mandibular Movement Index(M.M.I.) was formulated and compared to Helkimo's Clinical Dysfunction Index by measuring two indices before treatment and 2 weeks, 4 weeks, 6 weeks, 8 weeks after treatment. The conclusions were as follows: 1, The amounts of maximum opening and mean velocity during maximum opening and closing of TMD patients were less than those of normal persons(p<0.01). 2. The amounts of maximum opening and mean velocity during unilateral chewing of TMD patients were less than those of normal persons(p<0.05) (P<0.01). 3. Although TMD patients showed limited mandibular movements during unilateral chewing, the consistency of mandibular movements was better than that of normal persons(p<0.05). 4. Both mandibular movement index and Helkimo's Clinical Dysfunction Index, were useful in diagnosing TMD patients.

  • PDF

The Effects of Hip Extension Velocity on the Relative Onset Time of the Gluteus Maximus in Relation to the Hamstring (고관절 신전속도가 슬괵근에 대한 대둔근의 상대적 근수축 개시시간에 미치는 영향)

  • Chang, Young-Jin;Ko, Eun-Hye;Roh, Jung-Suk;Cynn, Heon-Seock;Kim, Tack-Hoon
    • Physical Therapy Korea
    • /
    • v.13 no.2
    • /
    • pp.70-76
    • /
    • 2006
  • The purpose of this study was to investigate the effects of hip extension velocity (7.5 degree/second, 30 degree/second) on the relative onset time of the gluteus maximus in relation to the hamstring during hip extension in prone position. Thirteen healthy male subjects (mean age=22.6 years [SD=1.8], mean weight=73.4 kg [SD=10.3], mean height=176.1 cm [SD=6.3]) voluntarily participated in this study. Electromyographic data was collected on the gluteus maximus and hamstring to determine onset time. Statistical analyses were performed with the paired t-test. The results showed that the onset time of the hamstring was significantly faster than that of the gluteus maximus in both fast and slow hip extension velocity. The gluteus maximus began contraction .079 seconds later following the contraction of the hamstring. The onset time of the hamstring was significantly faster in fast hip extension velocity compared with slow hip extension velocity. In conclusion, it was determined that the onset time of the gluteus maximus was faster with fast hip extension velocity compared with slow hip extension velocity. There was a statistically significant difference between the onset times of the gluteus maximus and hamstring in relation to the two velocities (p<.05). Further study is needed to examine whether the velocity of hip extension can influence the onset time in a similar fashion in patients with low back pain.

  • PDF

Development of a Current-Type Electromagnetic Flowmeter to Obtain the Liquid Mean Velocity in Two-Phase Slug Flow (슬러그류 액상속도 측정용 전류형식 전자기유량계 개발)

  • Kang, Deok-Hong;Ahn, Yeh-Chan;Kim, Jong-Rok;Oh, Byung-Do;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1951-1956
    • /
    • 2004
  • The transient nature and complex flow geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et $al.^{(1)}$). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. To do this, the velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for the simulated slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are required for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

  • PDF