• Title/Summary/Keyword: Mean Temperature

Search Result 3,912, Processing Time 0.032 seconds

An Experimental Study on the Lift-off Characteristics of the Triple Flame with Concentration Gradient (농도구배가 삼지화염의 부상특성에 미치는 영향에 관한 실험적 연구)

  • Seo, Jeong-Il;Kim, Nam-Il;Oh, Kwang-Chul;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.7-14
    • /
    • 2004
  • The lift-off characteristics of the triple flame have been studied experimentally with various mean velocities and concentration gradients using a multi-slot burner, which can control the concentration gradient and the mean velocity independently, Lift-off height, axial maximum velocity, flame temperature, and some other characteristics were examined for methane and propane flame, It was found that minimum values of the lift-off heights exist at a certain concentration gradient for constant mean velocity, and this result implies that the propagation velocity has a maximum value at this condition, OH radical distribution was measured with LIF method and velocity variation along streamline was measured with PlV system. In addition maximum temperature along streamline was measured with CARS system. The intensity of the diffusion flame affects on the propagation velocity of triple flame in the region of very weak concentration gradient.

  • PDF

Field Measurements of Indoor Air Quality in Apartment Units at Medium-size Cities (중소도시 공동주택의 실내공기질(새집증후군) 실측에 관한 연구)

  • Yoon, JaeOck
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.81-86
    • /
    • 2010
  • The main sources of the new house syndrome(sometimes it called sick building syndrome) are a concentration of formaldehyde (HCHO) and a concentration of total volatile organic compounds(TVOC). I had field measurements of indoor air quality in the apartment unit at medium-size cities(Y city, C city). I measured indoor air temperature, HCHO concentration in 16 units, TVOC concentration in 6 units and air tightness in 7 units. And I measured outdoor air quality, HCHO concentration and TVOC concentration. Mean concentration of HCHO was $357{\mu}g/m^3$(2006 standard=$120{\mu}g/m^3$), mean concentration of TVOC was $3,092{\mu}g/m^3$ and mean effective air leakage area was 193 cm2. There was a close relation between the indoor air temperature and HCHO concentration, between the indoor air temperature and TVOC concentration. Air tightness also had relation.

Parameter estimation of mean field annealing technique for optimal boundary smoothing (최적의 Boundary Smoothing을 위한 Mean Field Annealing 기법의 파라미터 추정에 관한 연구)

  • Kwa
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.1
    • /
    • pp.185-192
    • /
    • 1997
  • We propose a method of paramete estimation using order-of-magnitude analysis for optimal boundary smoothing in Mean Field Annealing(MFA) technique in this paper. We previously proposed two boundary smoothing methods for consistent object representation in the previous paper, one is using a constratined regulaization(CR) method and the other is using a MFA method. The CR method causes unnecessary smoothing effects at corners. On the other hand, the MFA method method smooths our the noise without losing sharpness of corners. The MFA algorithm is influenced by several parameters such as standard deviation of the noise, the relativemagnitude of prior ter, initial temperature and final temperature. We propose a general parameter esimation method for optimal boundary smoothing using order-of-magnitude analysis to be used for consistent object representation in this paper. In addition, we prove the effectiveness of our parameter estimation and also show the temperature parameter sensitivities of the algorithm.

  • PDF

Paleoclimate Reconstruction for Chungbu Mountainous Region Using Tree-ring Chronology (아한대 침엽수류 연륜연대기를 이용한 중부산간지역의 고기후복원)

  • 최종남;유근배;박원규
    • The Korean Journal of Quaternary Research
    • /
    • v.6 no.1
    • /
    • pp.21-32
    • /
    • 1992
  • The paleoclimate of the Chungbu Mountainous Region, Mts. Seorak and Sobaek, was estimated by means of dendroclimatic methodology, The annual growth value of tree-rings is deeply interrelated with the mean temperature of April-May and July-August. The mean temperature of April-May of the reconstruction period(1635-1911), observation period(1912-1989), and the whole period(1635-1989) is 13.58$^{\circ}C$, 13.69$^{\circ}C$, and 13.6$0^{\circ}C$, respectively. That of July-August is $24.50^{\circ}C$, $24.62^{\circ}C$, and $24.58^{\circ}C$ respectively. The reconstructed mean temperature data for April-May and for July-August reveal 13.2 and 12.9 year cycles.

  • PDF

A Study on the Effects of Temperature Rise of Irrigation Water Passed Through the Warm Water Pool. (온수지에 의한 관개용수의 수온상승 효과에 관한 연구)

  • 연규석;최예환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.1
    • /
    • pp.4323-4337
    • /
    • 1977
  • The study was to estimate the effect of the rise of water temperature in the warm water pool and to make contribution to the establishment of reducing to a damage of cool water as well as to the planning for warm water pool. This observation was performed in Wudu warm water pool located at Wudu-Dong of Chuncheon for two years from 1975 to 1976. The results were showed as follows; 1. The daily variation of water temperature was the least for inset (No.1; 0.6$^{\circ}C$) the second for middle overflow (No2: 3$^{\circ}C$, No.3; 2.3$^{\circ}C$) and another for outflet (No.4; 3.6$^{\circ}C$, No.5; 3.8$^{\circ}C$) And the highest reaching time of water temperature in each block was later about 1 hour than the time at which air temperature happend in the daytime. So, the variation of water temperature was sensitive to the variation of air temperature 2. The monthly variation of water temperature at each measuring point was plotted to be increased with increase in air temperature till August (Mean monthly rising degree; No.1; 1.15$^{\circ}C$, No.2; 1.7$^{\circ}C$, No.3; 1.73$^{\circ}C$, No.4; 2.08$^{\circ}C$, No.5; 2.0$^{\circ}C$), and expressed gradually descended influence upon water temperature after August. 3. The mean temperature of inflow folwed in warm Water pool was 7.5∼12.5$^{\circ}C$, and outflow temperature was described as 13.4∼22.5$^{\circ}C$ to be climbed. And So, the rising interval of water temperature was shown as 6.7∼10.4$^{\circ}C$. 4. The correlation between the rising of water temperature and the weather condition was found out highly significant. As the result, their correlation coefficents of water temperature depending on mean air temperature, ground temperature, wind velocity and relative humidity were to be 0.93, 0.90, - 0.83 and 0.71 respectively. But there was no confrimation of the correlation on the clouds, sunlight time, volume of evaporation, and heat capacity of horizontal place. 5. The water temperature of balance during the period of rice growing in Chuncheon district was shown as table 10, and the mean of whole period was calculated as about 23.7$^{\circ}C$. 6. The observed value of the outflow temperature passed through the warm water pool was higher than that of computed, the mean difference between two value was marked as 1.15$^{\circ}C$ for blockl, 1.18$^{\circ}C$ for block2, and 0.47$^{\circ}C$ for block3, respectivly. Therefore, the ratio on the rising degree between the observed and computed were shown as 53%, 44%, and 18%, mean 38% through each block warm water pool (referring item $\circled9$ of table 11,12, and 13). Accordingly, formula (4) in order to fit for each block warm water pool was transfromed as follow; {{{{ { theta }_{w } - { theta }_{ 0} =[1-exp LEFT { { 1-(1+2 varphi )} over {cp } CDOT { A} over { q} RIGHT } ] TIMES ( { theta }_{w } - { theta }_{ 0}) TIMES C }}}} Here, correction coefficinent was computed 1.38, and being substituted 1.38 for C in preceding formula, the expected water temperature will be calculated to be able to irrigate the rice paddy. As the result, we can apply the coefficient in order to plan and to construct a new warm water pool.

  • PDF

An Experimental study on the human's physiological in Smart Textile Materials by Using Medical Infrared Thermo graphic Imaging (적외선 체열 영상 진단법을 이용한 스마트 섬유소재와 휴대폰 통화량에 따른 인체 생리반응 연구)

  • Lee Tae-il;Lee Su-jeong;Lee Kyung-mi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.7 s.144
    • /
    • pp.918-925
    • /
    • 2005
  • The following are the results from the infrared body temperature image test to verify the changes in facial temperature according to call duration with a cellular phone. As for the body temperatures, it appears to be the mean value at the upper central point of phone's battery among 7 different points that are measured, and to be the highest at srernocleido-mastoid and scapular trapezius muscle triangle zone$(34.25^{\circ}C\; and\;34.05^{\circ}C\;each)$. The changes of body temperature according to the time duration shows that the body temperature rises according to the length of phone use because of the heat emitted from the battery. As for the temperature changes according to blocking materials, the one without processing appears to be higher in the mean temperature compared to the others that are processed, NSS(Nano Silver Silk) and NSG(Nano Silver Silk Gold) appear to be the lowest in the temperature to show the best blocking property. As for the temperature changes according to measuring points, it appears to be the highest at P4, P5 with all materials, and one with NSG to be the lowest at Pl, P2, P3, and one with NSS to be the lowest at P3, P4, P5, P6, which is due to the thermal conduction of Au and Ag. And the mean temperature at each point appears to be different according to the materials. Therefore, the study conducted with human participants requires a proper particle size of it which would not penetrate cellular tissues and a proper binder and binding treatment for it, to prevent the physical fatigues and the potential diseases. However, it is highly required for back-up researches to verify various aspects in applying nano silver to textile products.

Study on Meteorological Factors affecting Estimation of Chinese Cabbage Yield (배추 생산량 추정에 영향을 미치는 기상요소 연구)

  • Kim, Yong Seok;Shim, Kyo Moon;Jung, Myung Pyo;Choi, In Tae
    • Journal of Climate Change Research
    • /
    • v.6 no.4
    • /
    • pp.277-281
    • /
    • 2015
  • A Chinese cabbage is one of important vegetables which accounts for more than 60 percent of leaf vegetable. However, cultivation area and yield of Chinese cabbage are steadily decreasing recently. Because meteorological changes destabilize the balance of Chinese cabbage, we need to study on meteorological factors affecting estimation of Chinese cabbage yield. So we conducted a panel analysis using mean temperature, maximum temperature, minimum temperature, precipitation and sunshine's duration from August to November for estimation of Chinese cabbage yield. As the results, we found that if the mean temperature of September increase by $1^{\circ}C$ the amount of production of Chinese cabbage per unit area was increased by 348.6 kg/10a. We also found that the mean temperature of October increased by 174.8 kg/10a, that of November 148 kg/10a, the difference between the maxium temperature and the minimum temperature of October equals 443.3 kg/10a. However, we found that the difference between the maximum temperature and the minimum temperature of November decreased 274.1 kg/10a.

Comparison of Rectal Temperature with Axillary and Tympanic Temperature (신생아의 직장체온과 고막 및 액와체온과의 비교)

  • Hwang Jin-Soon;Sohng Kyeong-Yae
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.4 no.2
    • /
    • pp.351-358
    • /
    • 1997
  • Body temperature should be measured accurately to assess neonate's condition for proper care. Temperatures measured in rectal, axillary and tympanic site were compared in 129 normal neonates to find out proper nursing time for measuring temperature and the validity of fever detection. The results were as follows : 1. Mean temperatures of axillary and tympanic site($36.85^{\circ}C,\;37.12^{\circ}C$) were significantly lower than those of rectal site($37.19^{\circ}C$). 2. Mean nursing time for measuring body temperature was significantly higher and lower in axillary and tympanic temperatures(159.49 seconds, 11.07 seconds) than in rectal temperature(105.62 seconds). 3. Tympanic and axillary temperatures were significantly correlated with rectal temperature (r=0.85, r=0.78) and the significant correlation was demonstrated between tympanic and axillary temperatures(r=0.76). 4. Sensitivity, specificity, positive and negative predictive values were 0.87, 0.90, 0.72, 0.96 for detecting fever respectively. The above findings indicated that the tympanic thermometer offers a useful alternative to conventional methods.

  • PDF

The Current Distribution and Habitat Preferences of Hibernating Myotis formosus in Korea

  • Kim, Sun-Sook;Choi, Yu-Seong;Kim, Bong-Hyeon;Yoo, Jeong-Chil
    • Journal of Ecology and Environment
    • /
    • v.32 no.3
    • /
    • pp.191-195
    • /
    • 2009
  • We monitored 38 hibernation sites of Myotis formosus in South Korea and recorded the number of bats occupying each site and assessed the micro-climate at the sites during four winters from 2005 to 2009 at. The mean rock temperature of the bat roosting sites was $13.2{\pm}1.4^{\circ}C$ and the mean body temperature of the hibernating bats was $13.3{\pm}1.3^{\circ}C$. The number of hibernating bats was negatively related to the size of the entrance and positively related to the minimum ambient temperature and humidity in the site interior. More bats hibernated in roosts with smaller entrances and higher minimum ambient temperatures, and more bats selected sites presenting a narrow temperature range. This study showed that the internal environments of hibernacula of M. formosus were highly stable despite dramatic variation in the external environment.

Heat Transfer Model for Soil Irradiated by Infrared (적외선 조사된 토양에 대한 열전달 모델)

  • 강화석;이귀현;강위수;오재헌
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.449-455
    • /
    • 1996
  • The temperature distributions at various soil depths were predicted by heat transfer model during and after infrared irradiation on sand loam or loam soil. At each soil depth, predicted and measured temperature distributions were compared with using the mean relative percentage deviation and standard error. The mean relative percentage deviation was less than 10% between predicted and measured temperature distributions at each soil depth. Thus, it was concluded that the temperature distribution at each soil depth could be predicted satisfactorily by heat transfer model. Also, it is expected that these predicted temperature distributions can be used as basic information for determining the working speed of weeder and the size when the real weeder is constructed.

  • PDF