• Title/Summary/Keyword: Mean Plantar Pressure

Search Result 32, Processing Time 0.023 seconds

Analysis of Plantar Foot Pressure according to Insole Types during Treadmill Gait (트레드밀 보행시 인솔 형태 변화에 따른 족저압력 분석)

  • Woo, Jung-Hwi;Lee, Joong-Sook;Yang, Jeong-Ok;Lee, Bom-Jin;Bae, Kang-Ho;Han, Dong-Wook;Park, Sang-Muk;Bae, Jin-Woo
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.113-122
    • /
    • 2015
  • Objective : The purpose of this study was to analyze the foot-pressure distribution of 2D(2 dimensional form) & 3D(3 dimensional form; a customized arch-fit for posture correction) insoles for assessing their biomechanical functionality. Background : Recently there has been increased interest in both foot health and foot pain patients. Analysis of the plantar pressure was often used to solve the problems of the foot displayed by such people as rheumatoid arthritis patients. Method : Subjects who participated in this study were 17 female university students who had no previous injury experience in lower limbs and a normal gait pattern. The shoe size of all subjects was 240 mm. Two models of insoles of 2D(typical flat insole - 2 dimensional form) and 3D(special production - 3 dimensional form) were selected for the test. Using the Pedar-X system and Pedar-X insoles, 4.0 km/h of walking speed, and a compilation of 50 steps walking stages were used to analyze foot-pressure distribution. Results : Results of the foot-pressure distribution and biomechanical functionality on each insole were as follows; analyses of mean plantar pressure, maximum plantar pressure, maximum vertical GRF, and plantar pressure curve shape all showed overall low plantar pressure and GRF. Conclusion : This can be evaluated as an excellent insole for low levels on the plantar pressure and GRF. Therefore, it is possible to conclude that according to this analysis the 3D Customized Arch-fit Insole was better than 2D insole on the basis of these criteria.

The Effects of Plantar Foot Pressure and Muscular Activity on Treadmill Gait Training in Stroke Patients (트레드밀 보행훈련이 편마비 환자의 족저압과 하지 근활성도에 미치는 영향)

  • Kim, Eun-Jung;Jung, Jae-Min;Kim, Tae-Ho;Bae, Sung-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.3
    • /
    • pp.165-174
    • /
    • 2009
  • Purpose:This study was performed for effects of gait training on treadmill and stable surface which influenced on the lower limbs muscular activity needed in gait, plantar foot pressure with hemiplegic patients caused by cerebrovascular accident. Methods:Two groups of adult hemiplegia(n=20) were allocated randomly in this study: treadmill gait training group and control group. The gait training program was provided to experimental groups for 8 weeks (5 times a week). Measurements of pre and post experiment were plantar foot pressure. For measuring muscular activation rectus femoris, biceps femoris, tibialis anterior, gastrocnemius were detected. Results:The results of this study showed that in comparison of pre and post changes of gait training, the treadmill gait training group has noticeable changes than other groups in activity of rectus femoris and tibialis anterior, the control group revealed statistically significant differences in plantar foot pressure Toe2-5, M1, M3, M5, MF area, activity of gastrocnemius. Conclusion:These results mean gait training resulted by treadmill, stable surface provides effective muscle activation and plantar foot pressure with stroke.

  • PDF

The Plantar Pressure Comparison between the Curved Rear Balance Shoes and Normal Shoes (유선형 후방 밸런스 신발과 일반 신발의 족저압 비교)

  • Kim, Youn-Joung;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.173-180
    • /
    • 2007
  • The purpose of study was to compare plantar pressure during walking wearing the curved rear balance and normal shoes. Twelve university students(height: $177.2{\pm}4.6cm$, weight: $68.4{\pm}5.8kg$, age: $26.2{\pm}1.6yrs.$) who have no known musculoskeletal disorders were recruited as the subjects. Plantar foot pressures were evaluated using the Tekscan's pressure measurement systems while subjects walked upright position wearing the curved rear balance and normal shoes in random order at a speed of 1.3 m/s. The contacting dimension, the mean plantar pressure, and the peak plantar pressure were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). As a result, the curved rear balanced shoes showed as large as 38 up to 50 % of area at the rear side of feet than the normal shoes when measuring the contact area with upright position. In the distribution of average pressure, the curved rear balanced shoes displayed fairly low pressure compared to other normal shoes in general except for one area, which is M2, and especially, the measured pressures at the both rear (M1) and middle (M5) side of feet were low and statically significant. The contact area of the curved rear balanced shoes when walking was significantly larger at the rear (M1) and fore (M6, M7) side of feet. When considering pressure distribution at walking, low pressure was detected at the rear side of feet with the curved rear balanced shoes and at the fore side of feet for other normal shoes. The results showed that the contacting dimension of the curved rear balance shoes that acts between shoes and feet was higher than the corresponding value for the normal shoes in general; therefore it would reduce the pressure to the feet by allowing the each sole of the foot on the ground evenly.

Comparison of plantar pressure and COP parameters in three types of arch support insole during stair descent in elderly with flatfoot (편평족 노인의 계단 하강 보행 시 아치 지지형 인솔 종류에 따른 족저압력 및 균형성 평가)

  • Han, Ki-Hoon;Bae, Kang-Ho;Jung, Ha-gon;Ha, Min-Sung;Choi, Do-Yeol;Lee, Joong-Sook;Yang, Jeong-Ok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.948-955
    • /
    • 2018
  • The purpose of this study was to compare plantar pressure and COP parameters in three types of arch support insole during stair descent in elderly with flatfoot. A total of 14 women elderly were recruited for this study. Pedar-X was used to obtain plantar pressure(peak pressure, mean pressure, and contact area) and COP(distance, displacement, excursion) parameters. One-way ANOVAs were used to compare peak pressure, mean pressure, and contact area, distance of COP, displacement of COP, and excursion of COP. Among the plantar pressure parameters, significant(p<0.05) differences were observed in M3 for the peak pressure, M2, M3, and M4 for the mean pressure, and M2, M3, and M6 for the contact area. Among the COP parameters, distances of COP both in the mediolateral and anteroposterior axes revealed significant(p<0.05) differences. The larger peak pressure values of type A and B insoles were observed as compared to normal insole. The larger peak pressure and shorter COP distance values of type A and B insoles were observed as compared to normal insole.

Comparison of Muscle Activity of Thigh and Plantar Pressure according to the Change in Base of Support during Lunge (런지 시 기저면 변화에 따른 넙다리 근육의 근활성도와 족저압 비교 연구)

  • Lee, Jeon-Hyeong;Lee, Myoung-Hee;Kim, Gi-Chul
    • PNF and Movement
    • /
    • v.15 no.3
    • /
    • pp.343-351
    • /
    • 2017
  • Purpose: This study aimed to suggest effective lunge exercise methods for various purposes by comparing differences in the muscle activity of thigh and plantar pressure according to changes in base of support during lunge exercises. Methods: The subjects were 20 college students who agreed to participate in the experiment. They performed three types of lunges-a basic lunge (BL), wide lunge (WL), and narrow lunge (NL). In a static position during each lunge, the muscle activity of the thigh and plantar pressure were measured. Each movement was maintained for 7 seconds, and the muscle activity for the 3 seconds in the middle was measured and analyzed. The plantar pressure was divided into six areas for analysis. The subjects randomly performed the lunges to prevent the influence of an experimental sequence. Each movement was performed three times, and the mean value of the three measurements was analyzed. Results: The analysis of muscle activities in the thigh during the three lunge movements showed statistically significantly higher muscle activity of biceps femoris in WL and NL than BL. Moreover, the analysis of plantar force showed statistically significant differences between BL and WL and WL and NL on the medial-forefoot and medial-midfoot, as well as between BL and WL and BL and NL on the lateral-midfoot. The analysis of plantar contact pressure exhibited statistically significant differences between BL and NL and WL and NL on the medial-forefoot, as well as a statistically significant difference between WL and NL on the medial-midfoot and lateral-hindfoot. Conclusion: This study suggests that changing the base of support during lunges can be useful to suit the purposes of various rehabilitation programs.

Analyses of Plantar Foot Pressure and Static Balance According to the Type of Insole in the Elderly

  • Bae, Kang-Ho;Shin, Jin-Hyung;Lee, Joong-Sook;Yang, Jeong-Ok;Lee, Bom-Jin;Park, Seung-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.115-126
    • /
    • 2016
  • Objective: The purpose of this study was to investigate plantar foot pressure and static balance according to the type of insole in the elderly. Methods: Thirteen elderly (mean age: $67.08{\pm}2.25years$, mean height: $159.63{\pm}9.64cm$, mean body weight: $61.48{\pm}9.06kg$) who had no previous injury experience in the lower limbs and a normal gait pattern participated in this study. Three models of insoles of the normal, 3D, and triangle types were selected for the test. The Pedar-X system and Pedar-X insoles, 3.3 km/h of walking speed, and a compilation of 20 steps walking stages were used to analyze foot-pressure distribution. Static balance test was conducted using Gaitview AFA-50, and balance (opening eyes, closing eyes) was inspected for 20 s. One-way ANOVA was conducted to test the significance of the results with the three insoles. p-value of less than .05 was considered statistically significant. Results: The mean foot pressure under the forefoot regions was the lowest with the 3D insole during treadmill walking (p<.05). The mean value under the midfoot was the highest with the 3D insole (left: p<.05, right: p<.01). The mean value under the rearfoot was the lowest with the 3D insole (p<.001). The maximum foot pressure value under the foot regions was the lowest on both sides of the forefoot with the 3D insole. A statistically significant difference was seen only in the left foot (p<.01). The maximum value under the midfoot was the highest with the 3D insole (p<.001). No statistically significant difference was detected on the values under the rearfoot. In the case of vertical ground reaction force (GRF), statistically significant difference was seen only in the left side rearfoot (p<.01). However, static balance values (ENV, REC, RMS, Total Length, Sway velocity, and Length/ENV) did not show significant differences by the type of insole. Conclusion: These results show that functional insoles can decrease plantar pressure and GRF under the forefoot and rearfoot. Moreover, functional insoles can dislodge the overload of the rearfoot and forefoot to the midfoot. However, functional insoles do not affect the static balance in the elderly.

Comparative Analysis of Plantar Pressure and Comfort Level in Developed-Domestic and Import Comfort Shoes for Elderly (고령층용 국내 개발 및 수입 컴포트화의 족저압 및 착화감 비교 분석)

  • Kim, Jae-Won;Choi, Jin-Seung;Park, Tae-Hyun;Tack, Gye-Rae;Choi, Kook-Lyeol;Lee, Sung-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.4
    • /
    • pp.442-449
    • /
    • 2013
  • This study was to compare a domestic comfort shoes to the popular import(SAS$^{(R)}$) to gain a better understanding in biomechanical characteristics for shoe design for the elderly. For each shoe type, morphologic dimensions, shock absorption, and flexibility were assessed. From subjects(n = 20, $72.4{\pm}5.5$ years, $67.7{\pm}7.9$ kg), mean peak pressure(MPP) and contact area(CA) at the plantar surface were analyzed. The domestic shoes reflecting anatomic contour of the plantar surfaces of Asians resulted in wider CA(by 30.4 $cm^2$), higher shock absorption(by 2.4%) and stiffness(by 0.5 N/mm) than the import. With the domestic shoes, significantly less MPPs were found at the forefoot(by 42~49%) regions(p < .05) and higher CA was noted additionally at hallux and lessor toes(by 26~63%). More anatomically-contoured insole and favorable mechanical characteristics may help reduce the plantar pressures more effectively and more evenly, especially across the central forefoot and midfoot regions of the plantar surface, especially for the design of the comfort shoes for the elderly.

Analysis of the Gait Characteristics and Usability after Wearable Exoskeleton Robot Gait Training in Incomplete Spinal Cord Injury Patients with Industrial Accidents: A Preliminary Study

  • Bae, Young-Hyeon;Kim, Sung-Shin;Lee, Anna;Fong, Shirley S.M.
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.235-244
    • /
    • 2022
  • Objective: The aim of this study was to investigate of the foot plantar pressure and usability after gait training using the ExoAtlet wearable exoskeleton robot in an incomplete spinal cord injury (SCI) patient. Design: A case study Methods: Six participants with an asymmetry in motor and sensory function completed the gait training using ExoAtlet wearable exoskeleton robot for 15 sessions, five per weeks, 3weeks. They were divided into two groups (low and high strength group) and group differences were evaluated about session at stating of gait, gait distance at final session and foot plantar pressures and useability after training. Results: Low strength group was faster than high strength group on adaptation of robot gait. And high strength group increased faster than low strength group on the gait distance during training. In standing and gait, weaker leg was higher than stronger leg on mean foot plantar pressure in low strength group. And stronger leg was higher than weaker leg on foot plantar pressure in high strength group. The length of the anterior-posterior trajectory of the center of pressure during gait was similar in low strength group, but different in high strength group. useability was positive about ExoAtlet wearable exoskeleton gait after training. Conclusions: ExoAtlet wearable exoskeleton robot gait training was positive about improving gait in all participants regardless of differences in severity of symptoms and gait abnormalities.

Changes in Plantar Pressure and Gait Characteristics in Adults with Asymptomatic Flexible Pes Planus by Different Taping (테이핑 방법에 따른 유연성 평발의 족저압 및 보행 특성 변화)

  • Kim, Jong-Soon
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.167-177
    • /
    • 2022
  • Purpose: Pes planus is a common foot deformity that involves the loss of the medial longitudinal arch. The medial longitudinal arch deformity is usually asymptomatic; however, it can lead to an increased risk of pain and injury. Low-Dye taping is designed to treat plantar heel pain and pes planus. However, low-Dye taping is relatively complex, and a considerable amount of time is required to apply the tape correctly. The purpose of this study was to compare the acute effect of two different types of taping (low-Dye taping and modified Mulligan taping) on arch reformation, plantar pressure, and gait characteristics in participants with asymptomatic flexible pes planus. Methods: Twenty subjects (9 males and 11 females; mean age = 21.95 years) with asymptomatic flexible pes planus voluntarily participated in this study. Arch reformation was evaluated using navicular height measurements. Changes in plantar pressure distribution were measured using BioRecue equipment. Gait parameters were measured using spatiotemporal data collected during consecutive gait cycles using a G-WALK device. One-way analysis of variance was used to compare the three different conditions (i.e., bare foot, low-Dye taping, and modified Mulligan taping) for each variable. Results: Navicular height was significantly increased in subjects who underwent the two types of taping compared to those who experienced the bare foot condition. The plantar pressure was significantly shifted to the posterolateral area after modified Mulligan taping compared with the bare foot condition. There were no significant differences in the gait parameters. Conclusion: The findings of this study indicate that modified Mulligan taping has a similar effect to low-Dye taping, and modified Mulligan taping is a simpler method than low-Dye taping.

Comparative Analysis of Two Pedobarography Systems (두 족저압 측정장비의 비교 분석)

  • Ho Won Kang;Soomin Pyeun;Dae-Yoo Kim;Yun Jae Cho;Min Gyu Kyung;Dong Yeon Lee
    • Journal of Korean Foot and Ankle Society
    • /
    • v.28 no.1
    • /
    • pp.21-26
    • /
    • 2024
  • Purpose: Foot pressure measurement devices are used widely in clinical settings for plantar pressure assessments. Despite the availability of various devices, studies evaluating the inter-device reliability are limited. This study compared plantar pressure measurements obtained from HR Mat (Tekscan Inc.) and EMED-n50 (Novel GmbH). Materials and Methods: The study involved 38 healthy male volunteers. The participants were categorized into two groups based on the Meary's angle in standing foot lateral radiographs: those with normal feet (angles ranging from -4° to 4°) and those with mild flatfeet (angles from -8° to -15°). The static and dynamic plantar pressures of the participants were measured using HR Mat and EMED-n50. The reliability of the contact area and mean force was assessed using the interclass correlation coefficient (ICC). Furthermore, the differences in measurements between the two devices were examined, considering the presence of mild flatfoot. Results: The ICC values for the contact area and mean force ranged from 0.703 to 0.947, indicating good-to-excellent reliability across all areas. EMED-n50 tended to record higher contact areas than HR Mat. The mean force was significantly higher in the forefoot region when measured with EMED-n50, whereas, in the hindfoot region, this difference was observed only during static measurements with HR Mat. Participants with mild flatfeet exhibited significantly higher contact areas in the midfoot region for both devices, with no consistent differences in the other parameters. Conclusion: The contact area and mean force measurements of the HR Mat and EMED-n50 showed high reliability. On the other hand, EMED-n50 tended to record higher contact areas than HR Mat. In cases of mild flatfoot, an increase in contact area within the midfoot region was observed, but no consistent impact on the differences between the two devices was evident.