• 제목/요약/키워드: Mean Load

검색결과 970건 처리시간 0.033초

Ergonomic Assessment for Manual Materials Handling of Livestock Feed by Elderly Farmers in Korea

  • Kim, Insoo;Lee, Kyung-Suk;Kim, Kyung-Ran;Chae, Hye-Seon;Kim, Sungwoo
    • 대한인간공학회지
    • /
    • 제34권3호
    • /
    • pp.279-291
    • /
    • 2015
  • Objective: The purpose of the study is to evaluate appropriate weight for aged farmers in manually handling livestock feed in bags using ergonomic methods. Background: In the livestock industry in South Korea, despite the trend of aging of labor manpower, heavy items are still manually handled in many farms. In particular, among stockbreeding works, the handling of feed in bags weighing 25~30kg is reported as a cause of frequent injuries and musculoskeletal system diseases. However, studies on the standard for recommended weight allowed considering the physical characteristics of aged farmers older than 60 years with greatly decreased physical strength and muscle strength are insufficient. Method: To evaluate appropriate weight for handling of heavy livestock feed in bags, physical techniques for measuring recognized levels of physical work loads, the NLE (NIOSH lifting equation) a method that is an observation type technique, and an ergonomic modeling technique to predict compressive force imposed on L5/S1 were used. Subjects who participated in the experiment were organized into two groups of males/females with mean age exceeding 60 years, and lifting tasks were evaluated for nine weight levels. Results: Based on the results of psychophysical measurement, females showed a tendency of more drastic increases compared to males when weight was over 19kg. The results of estimation of regression models for the weight, 18.0 kg ($r^2=0.97$) and 15.3kg ($r^2=0.97$) were evaluated as stable load for males and females, respectively. In addition, both the observation type evaluation and ergonomic model evaluation showed stable loads in a range of 15~18kg. Conclusion: Given the results of the study, the weight of the feed in bags currently distributed to farms can become a cause of not only overexertion but also farm work related disasters such as musculoskeletal disorders and safety accidents. Providing livestock feed in bags weighing not more than 19kg for aged farmers is judged desirable, and managerial improvement for this matter is considered necessary. Application: The results of the present study can be utilized as useful data for institutional improvement of the weight of livestock feed in bags.

Comparison of Relative Thickness of the Iliotibial Band Following Four Self-Stretching Exercises

  • Kim, Hyun-Sook;Yoon, Tae-Lim
    • 한국전문물리치료학회지
    • /
    • 제19권4호
    • /
    • pp.24-31
    • /
    • 2012
  • The aim of this study was to investigate the effectiveness of self-stretching exercises for iliotibial band (ITB) (Side-lying; right hip and knee were flexed to support the pelvis while left hip was extended and adducted, Standing A; side-bending of the trunk on standing with crossed leg, Standing B; same as Standing A, except the hands were clasped overhead and shifted right side, and Standing C; same as Standing B, except moving the arms diagonally downward) to help determine the most effective self-stretching method to stretch ITB. Twenty-one healthy subjects who do not have ITB shortness from Yonsei University (14 men and 7 women) between the ages of 18 to 28 years voluntarily participated. Ultrasound was performed to measure the thickness of the ITB between the long axis of the ITB and the level parallel to the lateral femoral epicondyle during four self-stretching exercises. All data were found to approximate a normal distribution. We used a one-way repeated-measures analysis of variance (ANOVA) to compare the thickness of the ITB among all self-stretching exercises. The level of significance was set at ${\alpha}$=.05. The ANOVA was followed by Bonferroni's correction. The overall mean of ITB thickness was $1.14{\pm}.4$ mm (${\pm}$ standard deviation) in resting status. The change in the ITB thickness in percentages between the tested position of each self-stretching exercises and resting status was significant (p<.05) (Side-lying $26.62{\pm}10.18%$ with 95% confidence interval [CI]=21.99~31.25%; Standing A $29.46{\pm}16.19%$ with 95% CI=22.09~36.84%; Standing B $44.06{\pm}14.82%$ with 95% CI=37.31~50.81%; Standing C $53.76{\pm}12.1%$ with 95% CI=48.25~59.29%). Results indicated significant differences among four self-stretching exercises except Side-lying versus Standing A (p<.01). Based on these findings, the Standing C self-stretching exercise was the most effective in stretching the ITB thickness among four types of ITB self-stretching exercises. Additionally, the Side-lying self-stretching exercise using gravity to stretch the ITB is recommended as a low-load (low-intensity), long-duration stretch.

Shear bond strength of veneering porcelain to zirconia and metal cores

  • Choi, Bu-Kyung;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권3호
    • /
    • pp.129-135
    • /
    • 2009
  • STATEMENT OF PROBLEM. Zirconia-based restorations have the common technical complication of delamination, or porcelain chipping, from the zirconia core. Thus the shear bond strength between the zirconia core and the veneering porcelain requires investigation in order to facilitate the material's clinical use. PURPOSE. The purpose of this study was to evaluate the bonding strength of the porcelain veneer to the zirconia core and to other various metal alloys (high noble metal alloy and base metal alloy). MATERIAL AND METHODS. 15 rectangular ($4\times4\times9mm$) specimens each of zirconia (Cercon), base metal alloy (Tillite), high noble metal alloy (Degudent H) were fabricated for the shear bond strength test. The veneering porcelain recommended by the manufacturer for each type of material was fired to the core in thickness of 3mm. After firing, the specimens were embedded in the PTFE mold, placed on a mounting jig, and subjected to shear force in a universal testing machine. Load was applied at a crosshead speed of 0.5mm/min until fracture. The average shear strength (MPa) was analyzed with the oneway ANOVA and the Tukey's test ($\alpha$= .05). The fractured specimens were examined using SEM and EDX to determine the failure pattern. RESULTS. The mean shear strength ($\pm\;SD$) in MPa was 25.43 ($\pm\;3.12$) in the zirconia group, 35.87 ($\pm\;4.23$) in the base metal group, 38.00 ($\pm\;5.23$) in the high noble metal group. The ANOVA showed a significant difference among groups, and the Tukey' s test presented a significant difference between the zirconia group and the metal group. Microscopic examination showed that the failure primarily occurred near the interface with the residual veneering porcelain remaining on the core. CONCLUSION. There was a significant difference between the metal ceramic and zirconia ceramic group in shear bond strength. There was no significant difference between the base metal alloy and the high noble metal alloy.

고강도 전단철근을 사용한 철근콘크리트 전단벽체-기초계면에서의 전단마찰 거동특성에 대한 해석적 연구 (Analytical Study on Behavior Characteristic of Shear Friction on Reinforced Concrete Shear Wall-Foundation Interface using High-Strength Reinforcing Bar)

  • 천주현;이기호;백장운;박홍근;신현목
    • 콘크리트학회논문집
    • /
    • 제28권4호
    • /
    • pp.473-480
    • /
    • 2016
  • 본 연구에서는 550 MPa급 고강도 철근을 사용한 낮은 형상비를 갖는 철근콘크리트 전단벽체의 벽체-기초 접합부에서의 전단마찰 파괴거동을 평가하기 위한 해석적 방안을 마련하는 것을 목표로 한다. 형상비, 경계면에서의 마찰계수, 배근상세, 각 방향으로의 철근비, 재료물성 등의 다양한 변수를 갖는 총 16개의 실험체를 검증 대상으로 선정하여 저자 등에 의해 개발된 비선형 유한요소해석 프로그램(RCAHEST)에 콘크리트 구조설계기준(2012)과 CEB-FIP Model code 2010을 바탕으로 경계면에서 수정된 전단마찰 구성관계식을 적용하여 해석을 수행하였다. 최대 하중에 대한 실험과 해석으로부터의 결과는 평균과 변동계수가 각각 1.04와 17% 정도로 예측하였고 일부 실험체를 제외하고 파괴모드와 파괴시까지의 전반적인 거동 특성을 적절히 평가하였다. 결과를 종합해 볼 때, 수정된 전단마찰 구성관계식을 적용한 해석프로그램은 해석 결과에 비교적 높은 신뢰도를 확보하고 있는 것으로 판단된다.

Titanium Implant의 Removal Torque에 관한 연구 (A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS)

  • 이준석;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제32권1호
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

마이크로네시아 맹그로브 퇴적물 내 중금속 오염도 평가 (Assessment of Heavy Metal Pollution in Mangrove Sediments of Chuuk and Kosrae, Federated States of Micronesia)

  • 나공태;이미진;노재훈;박흥식;김은수;권문상;김경태
    • Ocean and Polar Research
    • /
    • 제35권4호
    • /
    • pp.453-464
    • /
    • 2013
  • 본 연구에서는 FSM 축과 코스레 맹그로브 퇴적물 내 7개 중금속(Cr, Ni, Cu, Zn, As, Cd 및 Pb)의 오염도를 평가하였다. 맹그로브 퇴적물 내 중금속의 평균농도는 Cr 642 ${\mu}g/g$, Ni 125 ${\mu}g/g$, Cu 46.9 ${\mu}g/g$, Zn 149 ${\mu}g/g$, As 15.6 ${\mu}g/g$, Cd 0.14 ${\mu}g/g$ 및 Pb 8.55 ${\mu}g/g$으로 Cr의 농도가 가장 높았으며 Cd이 가장 낮은 농도로 존재하고 있었다. 축과 코스레 지역을 비교하면 코스레 맹그로브 퇴적물은 Cr과 Ni의 농도가 축에 비해 높았으며, 나머지 원소인 Cu, Zn, As, Cd 및 Pb는 축 맹그로브 퇴적물에서의 농도가 코스레에 비해 높은 것으로 나타났다. 세계의 맹그로브 지역의 퇴적물 내 중금속의 농도와 비교한 축과 코스레 지역에서 채취한 맹그로브 퇴적물 Cr, Ni 및 As의 농도는 인간활동에 의한 인위적인 오염이 존재하는 다른 지역보다 높은 수준으로 나타났으며, Cu, Zn, Cd 및 Pb은 오염되지 않은 지역과 유사한 농도를 나타내었다. EF와 PLI를 이용하여 농축도(오염도) 평가결과에 의하면, As의 농축도는 높으나 나머지 원소는 오히려 배경농도에 비해 결핍된 것을 알 수 있었다.

대불산업단지 도로먼지 내 중금속류 오염 특성: 입도와 자성에 따른 구분 (Characteristics for Heavy Metal Pollution in Road Dust from Daebul Industrial Complex: Classification by Particle Size and Magnetic Separation)

  • 정혜령;최진영;나공태
    • 환경영향평가
    • /
    • 제29권4호
    • /
    • pp.252-271
    • /
    • 2020
  • 본 연구에서는 대불산업단지 내 14개 지점에서 채취한 도로먼지의 입도, 중금속 성분, 자기특성 등 물리 화학적 특성을 파악하고, 오염도 평가를 통해 주변 환경에 미치는 영향에 대한 고찰을 시행하였다. 도로먼지 내 금속농도는 Fe>Zn>Cu>Pb>Cr>Ni>As>Cd>Hg 순이었으며, 중금속류 오염은 연구지역의 주요 산업 및 교통 활동에 영향을 받은 것으로 나타났다. 도로먼지 내 중금속 원소와 입도와의 상관관계 분석결과는 Fe 및 모든 분석된 원소가 서로 유의한 상관관계를 가지며, 입자크기와는 유의한 음의 상관성을 가짐을 보여주었다(p<0.05). 그러나 큰 금속 입자들의 노면 유입으로 인해 일부 금속의 경우 >1000 ㎛의 입자의 중금속류 농도가 가장 높았으며, 이 분율의 단위면적당 오염부하량이 다른 입도분율보다 높았다. 도로먼지에서 자성입자의 분리 후 Cr, Ni, Cu, Zn, Cd, Pb의 농도 수준이 전체의 85(As)-22(Ni)%로 감소함을 알 수 있었다. 연구지역 도로먼지의 평균 중금속 오염도는 3지역 토양환경 우려기준을 초과하지 않아 우려할 수준은 아닌 것으로 나타났으나, 일부 지점의 경우 Zn 농도 기준을 초과해 재 비산이나 비점오염유출 등을 통해 도로먼지가 주변 환경에 미치는 영향과 효과적 관리방법에 대한 더욱 자세한 연구가 필요한 것으로 판단된다.

하천 퇴적물 내 중금속 오염도 평가에 관한 연구 (낙동강 수계 표층 퇴적물을 대상으로) (Contamination Assessment of Heavy Metals in River Sediments (For the Surface Sediments from Nakdong River))

  • 김신;안정민;정강영;이권철;권헌각;신동석;양득석
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.460-473
    • /
    • 2017
  • In order to certificate the contamination assessment of heavy metals in surface sediments from the Nakdong river. Surface sediments were collected of 24 sampling sites (main 14st., tributary 10st.) and analyzed for grain size heavy metals contents. Study area mainly composed of sand (avg. 94.1%) and mean grain size was $1.46{\Phi}$ on average. Heavy metals contents (avg. Al: 12.5%, Zn; 74.4, Cr: 45.3, Li: 26.0, Pb: 17.1, Ni: 10.5, Cu: 7.8, Cd: 0.22 mg/kg) were relatively high contents in the composed of fine sediments. In addition, the results of pearson's correlation coefficient showed that most heavy metals and grain size (silt and clay) were highly correlated. The contents of Zn (6st.) and Ni (1st.) evaluated as moderately polluted, Zn (6st.) evaluated as LEL when compared with sediment quality standard of USEPA and Ontario sediment quality guidelines. Most heavy metals contents were I levels that dose not affected the benthos when compared with sediment pollution evaluation standard of NIER. The results of EX, EF, Igeo and CF showed the contents of Zn, Pb and Cd exceed the background contents and distributing of anthropogenic pollution and evaluated as moderately polluted level. And Nm-08 were relatively high level of contamination in the study area. However as results of PLI (less than 1), all sampling sites were evaluated unpolluted level.

철근(鐵筋)콘크리트 도로교(道路橋) 상부구조(上部構造) 신뢰성(信賴性) 설계규준(設計規準)에 관한 연구(研究) (A Study on Reliability Based Design Criteria for Reinforced Concrete Bridge Superstructures)

  • 조효남
    • 대한토목학회논문집
    • /
    • 제2권3호
    • /
    • pp.87-99
    • /
    • 1982
  • R.C.도로교(道路橋) 상부구조(上部構造)의 신뢰성(信賴性) 설계(設計) 기준(基準) 제안(提案)는 것이 본(本) 연구(硏究)의 주요 내요(內容)이다. T형 및 4각형 단면(斷面)의 저항(抵抗) 불확실량(不確實量)과 교량사하중(橋梁死荷重) 및 교통활하중(交通活荷重)에 대한 불확실량(不確實量) 우리의 현실(現實)을 반영하는 적절(適切)한 값으로 제안(提案)하였다. Cornell의 MFOSM과 Lind Hasofer의 AFOSM을 포함하는 주요 2차(次)모멘트 신뢰성(信賴性) 이론(理論)을 비교(比較) 분석(分析)하므로서 Elllngwood의 반복시행(反復試行) 알고리즘과 대수정규형(對數正規型) 근사공식(近似公式)을 본(本) 연구(硏究)에서 제안(提案)하는 신뢰성(信賴性) 해석(解析) 및 설계기준(設計基準)의 유도에 사용함이 적절(適切)하다는 것을 알 수 있었다. 현행(現行) 도로교(道路橋) 설계규준(設計規準)에 따라 Calibration 하므로서 목표신뢰성지수(目標信賴性指數) ${\beta}_0=3.5$를 우리의 현실(現實)을 반영하는 최적치(最適値)로 선택(選擇)하였다. 상기(上記)한 불확실량(不確實量) 해석(解析) 이론(理論)에 의해 ${\beta}_0=3.5$에 대응(對應)하는 하중(荷重) 및 저항계수(抵抗係數)를 유도하였다. 그리고 현행(現行) WSD 도로교(道路橋) 설계(設計) 규준(規準)을 위해 신뢰성(信賴性) 이론(理論)에 의한 공칭안전율(公稱安全率)과 허용응력(許容應力)을 제안(提案)하였다. 본(本) 연구(硏究)에서 제안(提案)하는 R.C.도로교(道路橋)의 LRFD 신뢰성(信賴性) 설계기준(設計基準) 현행(現行) R.C.표준설계(標準設計) 시방서(示方書)의 규준(規準)에 대응(對應)하는 설계기준(設計基準)으로 도입(導入)함이 바람직하다는 사실(事實) 확인(確認)할 수 있었다.

  • PDF

Dicor와 수종 전장도재간의 전단결합강도 (THE SHEAR BOND STRENGTH BETWEEN DICOR AND SEVERAL VENEERING PORCELAINS)

  • 류경희;이선형
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.165-179
    • /
    • 1993
  • Dicor has not been prescribed routinely, in spite of many advantages, because of esthetic limitations by excessive translucency and external shading. In an attempt to solve these problems, the technique of veneering Dicor by aluminous poreclain has been used and recently Dicor Plus system was developed. The purpose of this study was to evaluate the compatibility between Dicor and several veneering porcelains by measuring the shear bond strength and observing the failure mode and interface appearance with SEM. Total 55 Dicor disks(10.0mm diam. X 3.0mm thickness) were fabricated by lost wax technique and divided into five groups of 11. Veneering porcelains such as Dicor Plus, Vitadur Alpha, Vitadur N, Vivodent, and Ceramco II were built up over the center of the treated Dicor surface using paper tube(5.0mm diam. X 4.0mm height) and fired according to the manufacturesr’instructions. A representative sample from each group was completely embedded in epoxy resin and crosssectioned, and remaining 50 samples were embedded in epoxy resin with the bonded area perpendicular to table base. The shear bond strengths were measured by applying the shear load parallel to Dicor surface close to the bonded area. Failure modes and interface appearances were observed using SEM at 15 and 1000 magnification respectively. The obtained results were as follows : 1. The mean shear bond strengths showed Dicor-Dicor Plus(10.53 MPa); Dicor-Vitadur Alpha(8.84 MPa); Dicor-Vitadur N(7.37 MPa); Dicor-Vivodent(4.28 MPa); Dicor-Ceramco II(0.89 MPa). 2. The shear bond strength of Dicor-CeramcoII was significantly decreased compared with Dicor-Dicor Plus(p<0.01), but had no significant difference compared with Dicor-Vivodent(p>0.01). 3. The shear bond strengths of Dicor-Vitadur Alpha and Dicor-Vitadur N were not significantly different compared with Dicor-Dicor Plus(p>0.01). 4. SEM examination of bond failure modes revealed that Dicor-Dicor plus, Dicor-Vitadur Alpha, Dicor-Vitadur N exhibited cohesive failure within Dicor and Dicor-Vivodent exhibited adhesive failure. And Dicor-Ceramco III exhibited adhesive failure and cohesive failure within CeramcoIII together. 5. SEM examination of interfaces revealed that Dicor-Dicor Plus exhibited the most tight contact and Dicor-Vitadur Alpha, Dicor-Vitadur N exhibited acceptible contacts. But Vivodent exhibited discontinuous gap and Ceramco II exhibited large continuous gap.

  • PDF