• Title/Summary/Keyword: Mean Load

Search Result 981, Processing Time 0.023 seconds

Comparative Analysis of Muscle Activities for Upper Extremity During Resistance Exercises Using Variable and Elastic Loads (가변부하 및 탄성부하를 이용한 저항성 기구 운동 시 발현되는 상지근육의 근 활동치 비교분석)

  • Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.37-44
    • /
    • 2006
  • The purposes of this study were to analyze and compare EMG activities of the pectoralis major, biceps brachii, triceps brachii, and brachioradialis muscles during biceps curls using a VRT device and an elastic tubing. Fifteen male college students were recruited as subjects and they performed 10-RM and 20-RM biceps curls. For each load and device condition, the mean and peak normalized EMG levels during different phases of a biceps curl were computed. For each load and phase, paired t-test (p.05) was used to find the significant difference between two devices. ANOVA with repeated measures was also used to find the significant difference among phases in terms of EMG values for each muscle. For each load and device condition, the peak and mean EMG levels during different phases of a biceps curl were computed The significant differences between devices were found in biceps brachii for EA, MD, LD phases, and triceps brachii muscles for all phases, respectively. However, no differences were found among phases for any muscle. This indicated that elastic band could have a similar characteristics of VRT. High antagonistic muscle activity as a function of injury prevention which found particularly in VRT device may suggest that elastic tubing can be a safer training device than VRT. This also imply that elastic tubing could be very effective as a home exercise tool for rehabilitation patients and elderly people.

Effect of Wave Load on the Member Force of Steel Structure of Floating Buildings

  • Lee, Young-Wook;Park, Tae-Jun
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1431-1439
    • /
    • 2018
  • For floating buildings may fl oat on the water for a long time, they are constantly affected by various environmental loads such as wind and wave loads. In this study to find the wave effect on the floating building, five models are designed using steel moment resisting frame. It is assumed that the lower part of the floating building is a reinforced concrete pontoon, while the upper part is a three-story steel frame. To analyze floating buildings affected by wind and wave loads, hydro-dynamic and substructure analysis are performed. As input loads, this study set limits that the mean wind velocity is 35 m/s and the significant wave height is 0.5 m for the residential building. From the hydrodynamic analysis, the time-history acceleration of building is obtained and transformed into a base ground input for a substructure analysis of the superstructure of the building. Finally the mean of the maximum from 30 dynamic analysis of the floating buildings are used to be compared with the results of the same model on the ground. It was shown that the dynamic results with wind and wave loads are not always lesser than the static results which are calculated with static equivalent wind load for a building that is located on the ground.

Evaluation of full-order method for extreme wind effect estimation considering directionality

  • Luo, Ying;Huang, Guoqing;Han, Yan;Cai, C.S.
    • Wind and Structures
    • /
    • v.32 no.3
    • /
    • pp.193-204
    • /
    • 2021
  • The estimation of the extreme wind load (effect) under a mean recurrence interval (MRI) is an important task in the wind-resistant design for the structure. It can be predicted by either first-order method or full-order method, depending on the accuracy and complexity requirement. Although the first-order method with the consideration of wind directionality has been proposed, less work has been done on the full-order method, especially with the wind directionality. In this study, the full-order method considering the wind directionality is proposed based on multivariate joint probability distribution. Meanwhile, considering two wind directions, the difference of the corresponding results based on the first-order method and full-order method is analyzed. Finally, based on the measured wind speed data, the discrepancy between these two methods is investigated. Results show that the difference between two approaches is not obvious under larger MRIs while the underestimation caused by the first-order method can be larger than 15% under smaller MRIs. Overall, the first-order method is sufficient to estimate the extreme wind load (effect).

The elbow is the load-bearing joint during arm swing

  • Bokku Kang;Gu-Hee Jung;Erica Kholinne;In-Ho Jeon;Jae-Man Kwak
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.2
    • /
    • pp.126-130
    • /
    • 2023
  • Background: Arm swing plays a role in gait by accommodating forward movement through trunk balance. This study evaluates the biomechanical characteristics of arm swing during gait. Methods: The study performed computational musculoskeletal modeling based on motion tracking in 15 participants without musculoskeletal or gait disorder. A three-dimensional (3D) motion tracking system using three Azure Kinect (Microsoft) modules was used to obtain information in the 3D location of shoulder and elbow joints. Computational modeling using AnyBody Modeling System was performed to calculate the joint moment and range of motion (ROM) during arm swing. Results: Mean ROM of the dominant elbow was 29.7°±10.2° and 14.2°±3.2° in flexion-extension and pronation-supination, respectively. Mean joint moment of the dominant elbow was 56.4±12.7 Nm, 25.6±5.2 Nm, and 19.8±4.6 Nm in flexion-extension, rotation, and abduction-adduction, respectively. Conclusions: The elbow bears the load created by gravity and muscle contracture in dynamic arm swing movement.

A Study on Failure Analysis of Low Pressure Turbine Blade Subject to Fatigue Load (피로하중을 받은 저압 터빈 블레이드의 파손해석에 관한 연구)

  • 홍순혁;이동우;조석수;주원식
    • Journal of Welding and Joining
    • /
    • v.19 no.3
    • /
    • pp.298-304
    • /
    • 2001
  • Turbine blade is subject to force of three types ; the torsional force by torsional mount, the centrifugal force by the rotation of rotor and the cyclic bending force by steam pressure. The cyclic bending force was a main factor on fatigue strength. SEM fractography in root of turbine blade showed micro-clack width was not dependent on stress intensity factor range. Especially, fatigue did not exist on SEM photograph in root of turbine blade. To clear out the fracture mechanism of turbine blade, nanofractography was needed on 3-dimensional crack initiation and crack growth with high magnification. Fatigue striation partially existed on AFM photograph in root of turbine blade. Therefore, to find a fracture mechanism of the torsion-mounted blade in nuclear power plant, the relation between stress intensity factor range and surface roughness measured by AFM was estimated, and then the load amplitude ΔP applied to turbine blade was predicted exactly by root mean square roughness.

  • PDF

Probabilistic Approach on Railway Infrastructure Stability and Settlement Analysis

  • Lee, Sangho
    • International Journal of Railway
    • /
    • v.6 no.2
    • /
    • pp.45-52
    • /
    • 2013
  • Railway construction needs vast soil investigation for its infrastructure foundation designs along the planned railway path to identify the design parameters for stability and serviceability checks. The soil investigation data are usually classified and grouped to decide design input parameters per each construction section and budget estimates. Deterministic design method which most civil engineer and practitioner are familiar with has a clear limitation in construction/maintenance budget control, and occasionally produced overdesigned or unsafe design problems. Instead of using a batch type analysis with predetermined input parameters, data population collected from site soil investigation and design load condition can be statistically estimated for the mean and variance to present the feature of data distribution and optimized with a best fitting probability function. Probabilistic approach using entire feature of design input data enables to predict the worst, best and most probable cases based on identified ranges of soil and load data, which will help railway designer select construction method to save the time and cost. This paper introduces two Monte Carlo simulations actually applied on estimation of retaining wall external stability and long term settlement of organic soil in soil investigation area for a recent high speed railway project.

Endurance Evaluation and Fatigue Property fo Axle Housing (Axle Housing의 내구성 판단과 피로특성)

  • Byeon, Hui-Mun;Lee, Sun-Bok
    • 한국기계연구소 소보
    • /
    • s.13
    • /
    • pp.3-13
    • /
    • 1984
  • Fatigue failure of axle housing could cause many injuries and much financial loss. This challenges the engineer to improve design decisions involving fatigue. Endurance evaluation of axle housing is great interest to auto-mobile manufacturers for the sake of safety and reliability. Axle housing is subjected to gross vehicle weight(G.V.W)as mean load and alternating load. Theoretical design diagram involving mean and alternating stresses is used for the evaluation of axle housing fatigue endurance with the equivalent stress of fatigue critical area on the axle housing. Four point bending fatigue tests on axle housing with constant amplitude loading at approximately R=0 were performed with 50 ton servohydraulic strucural fatigue testing machine developed at KIMM. Specimens were made with the same material STKM 13B as the axle housing and tested to obtain S_N data. Five specimens of STKM 13B were tested at 253.61 MPa and weibull distribution was obtained at the same stress level. Material data and structural data were compares and fatigue stress property factor and fatigue life property factor were obtained.

  • PDF

Phosphorus Budget of a River Reservoir, Paldang (하천형 호수인 팔당호의 인 수지)

  • Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.270-284
    • /
    • 2018
  • Paldang is a river reservoir located in the Midwest of Korea, with a water volume of $244{\cdot}10^6m^3$ and a water surface area of $36.5km^2$. It has eutrophied since the construction of a dam at the end of 1973, and the phosphorus concentration has decreased since 2001. Average hydraulic residence time of the Paldang reservoir is about 10 days during the spring season and 5.6 days as an annual level. The hydraulics and water quality of the reservoir can differ greatly, both temporally and spatially. For the spring period (March to May) in 2001 ~ 2017, the reservoir mean total phosphorus concentration calculated from the budget model based on a plug-flow system (PF) and a continuous stirred-tank reaction system (CSTR) was 13 % higher and 10 % lower than the observed concentration, respectively. A composite flow system (CF) was devised by assuming that the transition zone was plug flow, and that the lacustrine zone was completely mixed. The mean concentration calculated from the model based on CF was not skewed from the observed concentration, and showed just 6 % error. The retention coefficient of the phosphorus derived from the CF was 0.30, which was less than those of the natural lakes abroad or river reservoirs in Korea. The apparent settling velocity of total phosphorus was estimated to be $93m\;yr^{-1}$, which was 6 ~ 9 times higher than those of foreign natural lakes. Assuming CF, the critical load line for the total phosphorus concentration showed a hyperbolic relation to the hydraulic load in the Paldang reservoir. This is different from the previously known straight critical load line. The trophic state of the Paldang reservoir has recently been estimated to be mesotrophic based on the critical-load curve of the phosphorus budget model developed in this study. Although there is no theoretical error in the newly developed budget model, it is necessary to verify the validity of the portion below the inflection point of the critical-load curve afterwards.

Characteristics of Biochemical Oxygen Demand Export from Paddy Fields during Storm and Non-storm Period and Evaluation of Unit Load (강우시와 비강우시 BOD 유출 특성 조사 및 원단위 평가)

  • Choi, Dongho;Cho, Sohyun;Hwang, Taehee;Kim, Youngsuk;Jung, Jaewoon;Choi, Woojung;Park, Hyunkyu;Yoon, Kwangsik
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.5
    • /
    • pp.531-537
    • /
    • 2017
  • The biologic Oxygen Demand (BOD) is a reliable and generally accepted indicator of water pollution by organic pollutants. Accordingly, estimation of BOD export from paddies carries important implications fwith regard to water management in rural areas. In this study, hydrology and BOD concentration were monitored during the period 2008 through 2012, in an effort to understand the characteristics of BOD export from paddy fields. The findings demonstrated that BOD load by rainfall above 50 mm. occupied about 50 % of total load, whereas the load by less than ten mm. rainfall occupied about 29 % of the total load during periods of stormy activity. It therefore seems that it could be possible to reduce the BOD load up to 29 % during storm periods, when drainage control conducted for rainfall less than ten mm.(an amount which is relatively easy to manage). The documented mean loads of storm and non-storm were $17.1kg\;ha^{-1}\;yr^{-1}$ and $11.2kg\;ha^{-1}\;yr^{-1}$, respectively. The BOD load during the significant rainfall period was similar to the renewed unit load by NIER (2014). However, there were substantial differences between unit load and actual load when the non-storm load was incorporated into the BOD load estimation from paddy fields. In view of the foregoing, it is felt that, the non-storm load needs to be further considered and managed for the successful implementation of Total Maximum Daily Load (TMDL) program.

Comparison of Unit Load from Paddy Field by Various Estimation Methods (산정방법에 따른 논 원단위 비교)

  • Choi, Dongho;Jung, Jaewoon;Yoon, Kwangsik;Choi, Woojung;Cho, Sohyun;Beom, Jina;Yoo, Seungwha
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.5
    • /
    • pp.407-419
    • /
    • 2015
  • The unit load of paddy field was estimated by several methods and compared in this study. Four year field study was conducted at the paddy fields located in Yeongsan river and Sumjin river basins. The unit load was estimated by four methods; (1) averaging field monitored load; (2) NIER (National Institute of Environmental Research) method which use EMC(Event Mean Concentration) and runoff ratio of rainfall groups with rainfall weighting factors; (3)method using EMC determined by best fit probability distribution; (4)method using arithmetic mean EMC and runoff ratio. The result of this study showed that the unit loads of water quality constituents by field monitoring was similar to those of NIER method whereas those by probability distribution(log-normal, gamma) method were less than unit loads of NIER method. The unit loads by arithmetic mean EMC and runoff ratio were larger than those by NIER method. The unit load by NIER method showed higher BOD, COD, SS, lesser T-N, and similar T-P values when compared to unit loads determined by MOE in 1995.