• 제목/요약/키워드: Mean Frequency

검색결과 4,572건 처리시간 0.037초

New Definition of the Fibrogram and Its Application to Cotton Blending

  • Jeon, Boong-Soo
    • Fibers and Polymers
    • /
    • 제6권4호
    • /
    • pp.332-335
    • /
    • 2005
  • The fibrogram theory is newly derived from the superposition principle of the conventional staple diagram, in which the left-hand ends of the fibers have to share a common starting point in order for the fiber length distribution to be measured, and the right-hand ends of the fibers form points. It is shown that the fibrogram is the staple diagram of the fiber sample having different random starting points, as well as the double cumulative distribution function of the frequency length function in the length biased sample. Also, the various means, viz. the numerical mean length, numerical mean length in median, length biased mean length, and length biased mean length in median, and the various upper half means, viz. the numerical upper half mean length, numerical upper half mean length in median, length biased upper half mean length, and length biased upper half mean length in median, are discussed in relation to the cotton blending process.

도시 및 농촌지역 가임연령 여성들의 혈중 미량금속원소의 함량에 관한 조사 (A study on the concentration of trace metal elements in whole blood of the women in reproductive ages in urban and rural area)

  • 전진호
    • Journal of Preventive Medicine and Public Health
    • /
    • 제17권1호
    • /
    • pp.95-106
    • /
    • 1984
  • 유해금속에 의하여 발생될 수 있는 건강장애를 예방하기 위한 대책수립에 필수적인 기초자료를 얻을 목적으로 도시 및 농촌지역에 거주하는 $20{\sim}39$세 사이의 가임연령여성 140명을 대상으로 하여 혈중미량금속원소들의 함량을 원자흡광광도분석기로 측정하여 얻은 결과를 요약하면 다음과 같다. 1. 혈중 아연의 농도는 도시지역 $10.69{\pm}8.07{\mu}g/ml$, 농촌지역 $9.53{\pm}6.60{\mu}g/ml$였으며 그 농도별 도수분포 양상은 양자 모두 L형에 유사하였고 이들의 누적분포 양상은 2봉성을 나타내었다. 2. 혈중 철의 농도는 도시지역 $323.09{\pm}87.15{\mu}g/ml$, 농촌지역 $322.07{\pm}104.74{\mu}g/ml$였으며 그 농도별 도수분포양상은 양자 모두 정규분포에 가까운 형이었으나 이들의 누적도수분포양상은 도시지역은 1봉성, 농촌지역은 2봉성을 나타내었다. 3. 혈중 마그네슘의 농도는 도시지역 $41.08{\pm}19.58{\mu}g/ml$, 농촌지역 $40.28{\pm}16.82{\mu}g/ml$였으며 그 농도별 도수분포양상은 양자 모두 오른쪽으로 치우쳐진 분포형으로서 이들의 누적도수분포양상은 1봉형을 나타내었다. 4. 혈중 동의 농도는 도시지역 $1.417{\pm}0.761{\mu}g/ml$, 농촌지역 $1.375{\pm}0.743{\mu}g/ml$였으며 그 농도별 도수분포양상은 양자 모두 오른쪽으로 치우쳐진 분포형으로서 이들의 누적도수분포양상은 2봉성을 나타내었다. 5. 혈중 망간의 농도는 도시지역 $0.079{\pm}0.039{\mu}g/ml$, 농촌지역 $0.07{\pm}0.058{\mu}g/ml$였으며 그 농도별 도수분포양상은 양자 모두 오른쪽으로 치우쳐진 분포형이었으나 농촌지역은 다소 불규칙한 양상이었고 이들의 누적도수분포양상은 도시지역은 1봉성, 농촌지역은 2봉성을 나타내었다. 6. 혈중 카드뮴의 농도는 도시지역 $0.031{\pm}0.026{\mu}g/ml$, 농촌지역$0.028{\pm}0.023{\mu}g/ml$였으며 그 농도별 도수분포양상은 양자 모두 오른쪽으로 치우쳐진 분포형으로서 이들의 누적도수분포양상은 2봉성을 나타내었다.

  • PDF

6.0~18.0 GHz 주파수용 광대역 DFD 위상 상관기 설계 및 제작 (Design and Fabrication of Wideband DFD Phase Correlator for 6.0~18.0 GHz Frequency)

  • 최원;구경헌
    • 한국항행학회논문지
    • /
    • 제18권4호
    • /
    • pp.341-346
    • /
    • 2014
  • 본 논문은 6.0~18.0 GHz 대역에서 동작하는 광대역 디지털 주파수 변별기(DFD, digital frequency discriminator)의 위상 상관기(phase correlator)를 설계하고 제작하였으며, 제작된 DFD 위상 상관기의 I와 Q 신호를 측정하고, 주파수 변별 오차를 분석하였다. 믹서형 위상 상관기의 동작 특성에 대한 해석적 관계식을 유도하였으며, 위상 상관기에 포함되는 IQ 믹서(mixer)와 8-way 전력분배기(power divider)는 RF 시뮬레이션 툴(tool)을 이용하여 모델링하였다. 설계된 위상 상관기는 제작되어 측정하였다. 제작된 위상 상관기의 I와 Q 출력신호를 측정하여 제시하였으며, 측정된 I와 Q 출력신호를 이용하여 위상오차(phase error)와 주파수 변별오차(frequency discrimination error)를 나타내었다. 위상 상관기의 평균 위상오차(phase error)는 $4.81^{\circ}$, RMS(root mean square)이고, 주파수 변별 오차는 1.49 MHz, RMS 이다.

인간 배아 동결 해빙시 액체질소의 분사속도가 배아 발달 및 임신에 미치는 영향 (Effects of Different Infusion Frequency of Liquid Nitrogen on Human Embryo Development and Pregnancy Rates after Freezing and Thawing)

  • 김영아;서성석;김미란;황경주;박동욱;조미영;유희석
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제28권4호
    • /
    • pp.287-293
    • /
    • 2001
  • Objective : To investigate the efficacy of high infusion frequency of liquid nitrogen on pregnancy in human embryo after freezing and thawing. Materials and Methods: 150 infertile patients underwent 162 consecutive thawing-ET cycles. In the high infusion frequency group (Group A), 47 patients (50 cycles) underwent cryopreservation with high infusion frequency of liquid nitrogen. In the low infusion frequency group (Group B), 103 patients (112 cycles) underwent cryopreservation with low infusion frequency of liquid nitrogen. We analyzed the clinical characteristics, fertilization rates, development of embryo, good quality embryo ratio, implantation rates, and pregnancy rates between these two groups. Results: There was no difference between the groups with regard to clinical characteristics (mean age, infertility duration, infertility factors, hormone profile), mean number of oocyte retrieval, fertilization rates, and mean embryo number of transfers. The survival rates in group A was 64.9% (228 of 350 embryos), and among the 228 embryos 190 embryos (83.3%) which progressed to the two- to eight-cell stage. After thawing, the embryo numbers were 65 (34.2%), 29 (15.3%), 35 (18.4%), and 37 (19.5%) of grades 1, 2, 3, and above 4, respectively. The survival rates in group B was 63.8% (482 of 755 embryos), and among the 482 embryos 465 embryos (96.5%) which progressed to the two- to eight-cell stage. After thawing, the embryo numbers were 106 (22.8%), 94 (20.2%), 89 (19.1%), and 112 (24.1%) of grades 1, 2, 3, and above 4, respectively. There was no difference in embryo quality change after the freezing-thawing procedure between the groups. Implantation rates (31.1% vs. 34.3%) were not significant. However hCG positive rates in group A (40%) were higher than group B, but not statistically significant. Clinical pregnancy rate (26% vs. 25.9%), on going pregnancy rates (>20 weeks) were not significant (26% vs. 25%). Conclusion: We compared embryo quality change, survival rates, and pregnancy rates between high infusion frequency group and low infusion frequency group and the results were similar between the two groups. Therefore, high infusion frequency of liquid nitrogen for cryopreservation is a worthy method to preserve in human embryos.

  • PDF

복위 및 측위에 따른 신생아의 활력증상, 울음회수, 수유량 및 배설횟수의 비교연구 (A Comparative Experimental Study on the Vital signs, Crying Fluid Intake and Excretion of the Full-term newborn Infant kept in the Prone or Lateral Position)

  • 한경자
    • 대한간호학회지
    • /
    • 제5권1호
    • /
    • pp.133-143
    • /
    • 1975
  • Most of mothers place their babies in either supine or prone position without change of position. Studies comparing supine and prone position of the newborn infants -have already been performed with the result that the prone position is relatively better than the supine position. However, one kind of position recommended to the mothers is not sufficient for the good rearing practice of children, because the same position placed for period long of time may bring out physical, mental tension and fatigue, and deformities of the skull and the thorax. For this reason nurses have to find out other position which has identical or more advantages than prone position so as to perform the position change for the babies. Main purpose of this study is to identify the differences of vital signs, the number of urination, defecation, diaper rash, crying and amount of feeding of the newborn infants with prone position or lateral position during the first three days of life. Sixty two newborn infants who were delivered at Seoul National University Hospital during the period from July 1 to September 5, 1974 were chosen as subjects for this study. The criteria for the choice of subjects were the babies born with vaginal delivery; body weight 2.5kg or over at birth; Apgar score Seven or over; and gestation period between thirty-eight months ana forty- two months. Of these subjects, by random sampling, thirty-one newborn infants were placed in the prone position and the other thirty-one in the lateral position. The results of this study reviewed in a statistical analysis of the t-test to obtain the following findings : 1. The heart rates of babies in the prone position were the mean heart rates of 135.03 and those in the lateral position 135.98 without any statistically significant difference. 2. There was no significant difference of respiration rate between two groups : a group in the prone position showed the mean respiration rates of 45,57 and the other in the lateral position 46.49. 3. There was no significant difference of body temperature between two groups: the mean body temperature of a group placed in the prone position was 98$^{\circ}$18'F(36$^{\circ}$77'C) and that of the other group 98$^{\circ}$20'F(36$^{\circ}$78'C). 4. One baby showed diaper rash only in a group of infants in the prone position. 5. The number of crying of the babies in the prone position were 23.70 and those in the lateral position 30.00 with a statistical difference at 5 percent level. 6, There was no difference of frequency of urination between two groups: the mean frequency of a group placed in tile prone position was 5.44 and that of the other group 5.06, 7. There was no significant difference of frequency of defecation between two groups : the mean frequency of a group placed in the prone position was 4.20 and that of tile other group 4.21, 8. There was no significant difference of feeding amount between two groups : the average amount of a group in the prone position showed 325.03 and that of the other group in the lateral position 291.51. All the above results mean that we may substitute tile lateral position for the Prone position or utilize both position for tile rearing practice of the babies.

  • PDF

Predicting Successful Defibrillation in Ventricular Fibrillation using Wave Analysis and Neuro-fuzzy

  • Shin Jae-Woo;Lee Hyun-Sook;Hwang Sung-Oh;Yoon Young-Ro
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권2호
    • /
    • pp.47-52
    • /
    • 2006
  • The purpose of this study was to predict successful defibrillation in ventricular fibrillation using parameters extracted by wave analysis method and neuro-fuzzy. Total 15 dogs were tested for predicting successful defibrillation. Feature parameters were extracted for return of spontaneous circulation (ROSC) and non-ROSC by wave analysis method, and these parameters are an irregularity factor, spectral moments, mean power of level-crossing spectrum, and mean of alpha-significant value. Additionally, two parameters by analyzing method of frequency were extracted into a mean of power spectrum and a mean frequency. Then extracted parameters were analyzed in which parameters result to have high performance of discriminating ROSC and non-ROSC by a statistical method of t-test. The average of sensitivity and specificity were 62.5% and 75.0%, respectively. The average of positive predictive factor and negative predictive factor were 61.2% and 75.8%, respectively.

OFDMA/TDD 시스템을 위한 효율적인 동기 추정 및 셀 탐색 기법 (An Efficient Synchronization and Cell Searching Method for OFDMA/TDD System)

  • 김정주;노정호;장경희
    • 한국통신학회논문지
    • /
    • 제30권9A호
    • /
    • pp.714-721
    • /
    • 2005
  • 본 논문에서는 직교 주파수 분할 다중 접속/시 분할 다중화(OFDMA/TDD :OFDM-FDMA/ Time Division Duplexing) 시스템에서의 프리앰블 모델을 분석하고, AWGN과 ITU-R M.1225 Ped-B 및 Veh-A 채널 환경에서 OFDMA/TDD 시스템에 적용된 심볼 타이밍 및 반송파 주파수 오프셋 추정과 셀 탐색 성능을 모의 실험을 통하여 그에 따른 성능을 Detection Probability, False Alarm, Missing Probability, Mean Acqusition Time 및 (MSE) Mean Square Error 로 확인한다. 특히, 심볼 타이밍 오프셋 추정에서는 향상된 성능을 가지는 프리앰블 구조 및 알고리즘을 제안한 후, 기존의 프리앰블 구조와 그에 따른 성능을 비교 분석한다.

임산부의 철분 섭취량과 흡수율 및 관련된 영양지식에 관한 연구 (Assessment of the Intake and Availability of Dietary Iron and Nutrition Knowledge in Pregnant Women)

  • 김은경;이규희
    • 대한지역사회영양학회지
    • /
    • 제3권1호
    • /
    • pp.53-61
    • /
    • 1998
  • This study was designed to estimate mean daily iron intake and its bioavailabi- lity and to assess nutrition knowledge for 144 pregnant women in the last trimester. Serum ferritin concentration was analyzed to estimate their iron stores. Dietary intakes of iron(heme iron and nonheme iron), the amounts of MPF(meat, poultry and fish) and ascorbic acid were assessed by modified 24-hr recall method. The food frequency questionnaire was used to assess subjects usual food consumption patterns. The mean value of serum ferritin was $21.3\pm{15.2ng/ml}$ and 26.4% of the pregnant women had a serum ferritin level <12ng/ml(i.e. depleted iron stores). The mean daily intake of total orin in the pregnant women was 56.5%(17.0mg) of RDA and heme iron intake was 0.94mg which was 5.5% of total iron intake. Total absorbable iron calculated by the method of Monsen was 2.41mg and bioavailability of dietary iron was 2.41%. Food frequency test score of meats group was positively correlated(r=0.443) with the bioaavailability of dietary iron. The mean score on the nutrition knowledge test of subjects was 12.76(out of a possible 20 points). These results indicate that the nutritional iron status may be improved by increasing either the amount of iron in the diet or its availability.

  • PDF

원호보간시험에 의한 수치제어 공작기계의 운동오차원인 진단에 관한 연구 (Identification of motion error sources in NC machine tools by a circular interpolation test)

  • 홍성욱;신영재;이후상
    • 한국정밀공학회지
    • /
    • 제10권2호
    • /
    • pp.126-137
    • /
    • 1993
  • This paper presents an efficient method for the identification of motion error sources in NC machine tools by making use of the circular interpolation test, which is often used in estimating the motion accuracy of NC machine tools. Mathematical formulae are described for motion errors due to various kinds of error sources. Two identification formulae are proposed: one is based on the frequency analysis and the other is formulated with the weithted residual method. Motion error signal is classified into two patterns, mean errors(mean of CW and CCW test signals from mean errors). The sources of the mean errors are identified by using the frequency analysis technique and the sources of the deviation errors by the weighted residual formulaltion. A menu driven, user oriented, computer program is written to realize the full steps of the proposed identificationprocedure. Then, the identification method is applied to two NC machine tools.

  • PDF

강인한 음성인식을 위한 극점 필터링 및 스케일 정규화를 이용한 켑스트럼 특징 정규화 방식 (Cepstral Feature Normalization Methods Using Pole Filtering and Scale Normalization for Robust Speech Recognition)

  • 최보경;반성민;김형순
    • 한국음향학회지
    • /
    • 제34권4호
    • /
    • pp.316-320
    • /
    • 2015
  • 본 논문에서는 Cepstral Mean Normalization(CMN)과 Cepstral Mean and Variance Normalization(CMVN) 프레임워크에서 극점 필터링(pole filtering) 개념을 Mel-Frequency Cepstral Coefficient(MFCC) 특징 벡터에 적용한다. 또한 분산 정규화를 대신하여 스케일 정규화를 사용하는 Cepstral Mean and Scale Normalization(CMSN)의 성능을 잡음 환경 음성인식 실험을 통해 평가한다. CMN과 CMVN은 보통 발화 단위로 수행되기 때문에 짧은 발화의 경우 특징에 대한 평균과 분산의 추정 신뢰도가 보장되지 않는 문제점을 가지는데, 극점 필터링과 스케일 정규화 방식을 적용함으로 이러한 문제점을 보완할 수 있다. Aurora 2 데이터베이스를 이용한 실험 결과, 극점 필터링과 스케일 정규화를 결합한 특징 정규화 방식의 성능이 가장 높은 성능 향상을 보인다.