• Title/Summary/Keyword: Mean Distance

Search Result 1,683, Processing Time 0.03 seconds

THE DISTANCE BETWEEN THE UPPER CANINE AND THE ORBITAL PLANE IN GNATHOSTATIC MODEL OF KOREANS WITH NORMAL OCCLUSION (한국인 정상교합자의 악태모형위에서의 안와평면과 상악견치 사이의 거리)

  • Lee, Soo-In;Choi, Mok-Kyun;Kim, Kwang-Hyun
    • The korean journal of orthodontics
    • /
    • v.5 no.1
    • /
    • pp.51-56
    • /
    • 1975
  • In orthodontic field, the study on gnathostatic model is very important to the diagnosis and analysis of malocclusion. The purpose of this study is to observe that relation of orbital plane and upper canine in Koreans. We selected 230 cases with normal occlusion, 124 male and 106 female cases aged from 12 years to 25 years, to prepare 230 gnathostatic models, and measured the distance from midpoint of mesio-distal distance of upper canine to orbital plane in gnathostatic model. The results obtained were as follows: 1) The mean value of the distance from upper canine to orbital plane showed no significant change with age. 2) The mean value of the distance from the upper canine to orbital plane was -3.11mm in male and -3.84mm in female. 3) The orbital plane passed through the upper canine in normal occlusion of Koreans.

  • PDF

A study on the reduction of the distance on reference ellipsoid to the distance on geoid (타원체상 거리의 지오이드면상 거리로의 보정에 관한 연구)

  • 김형태;김용일;어양담;김창재
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.2
    • /
    • pp.137-143
    • /
    • 1999
  • The straight spatial distance or geodesic distance on WGS84 ellipsoid measured by GPS should be reduced on geoid to be used in Korean Geodetic System. The factors for this reduction are geoidal height and mean radius of the earth. On this study the effects of these factors on reducing distance were analyzed and the result showed that mean geoidal height should be multiplied by $1.6\times{10}^{-7}$ per unit distance for reducing geodesic distance on reference ellipsoid to that on geoid. Condsidering that the geoidal height on Bessel ellipsoid in Korea is -45 m in northeast and -75 m in middle west. It also showed that the difference of geodesic distance between on reference ellipsoid and on geoid is about 7-12 mm per km.

  • PDF

A Study about Scapular Rhythm of Normal Persons (정상인들의 Scapular Rhythm에 대한 연구)

  • Kim, Keun-Jo;Kim, Bonn-Won;Ahn, Duk-Hyun
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.4
    • /
    • pp.139-145
    • /
    • 1996
  • This study was carried out to investigate the scapular rhythm of normal persons. 16 persons was no disease, injury and after-effect in period for July 1, 1996 to July 14, 1996. The statistical measures were performed by SPSS/PC t-test for classification. The result of this study were as follow : 1. There was a significant difference between the body median line and scapular superior angle from the mean distance in 83.4 mm of male and 86.0 mm of female to shoulder neutral position(p<0.05). 2. The mean distance of body median line between scapular inferior angle was 97.9 mm of male and 92.0 mm of female to shoulder neutral position. 3. There was a significant difference between the body median line and scapular inferior angle from the mean distance with male and female to shoulder abduction $90^{\circ}$ position(p<0.05). 4. The mean angle of body median line between scapular angle was $6.4^{\circ}$ of male and $4.4^{\circ}$ of female with shoulder neutral position. 5. The mean ratio of scapular rhythm was 5.6 : 1 in shoulder abduction of $90^{\circ}$ and 5.1 : 1 in shoulder abduction of 180.

  • PDF

Evaluation of Balance Ability of the Elderly Using Kinect Sensor (키넥트 센서를 이용한 고령자 대상의 선자세 균형능력 평가)

  • Yang, Seung-Tae;Kang, Dong-Won;Seo, Jeong-Woo;Kim, Dae-Hyeok;Kim, Tae-Ho;Choi, Jin-Seung;Tack, Gye-Rae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.439-446
    • /
    • 2017
  • Portable low-cost Kinect sensor was used to analyze standing balance ability of the elderly. Eighty subjects who can walk alone and have a normal cognitive level participated in this experiment. Based on Berg Balance scale (BBS) test with 52 points, subjects were divided into Healthy older (HO: 46 persons, BBS: $53.80{\pm}1.19$) and Impaired older (IO: 34 persons, BBS: $49.06{\pm}2.03$) group. Each subject performed 30 seconds four different standing balance tests (EO: Eyes Open, EC: Eyes Close, EOf: Eyes Open on foam, ECf: Eyes Close on foam). Five variables (Mean distance, Range of distance, Root mean square, Mean velocity, 95% ellipse area) were calculated from the hip joint center movement of Kinect sensor. Results showed that there were significant differences between groups for four different standing tests. Calculated variables from kinect sensor showed significant correlation with BBS score. Especially, mediolateral mean distance, mediolateral root mean square, mediolateral range of distance and 95% ellipse area showed discriminative ability for all tests. Mean values of variables of IO were higher than those of HO, which means the decreased balance ability in IO compared with HO. Therefore, it was possible to estimate simple balance assessment of the elderly using portable low-cost Kinect sensor.

The Weld Defects Expression Method by the Concept of Segment Splitting Method and Mean Distance (분할법과 평균거리 개념에 의한 용접 결함 표현 방법)

  • Lee, Jeong-Ick;Koh, Byung-Kab
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.37-43
    • /
    • 2007
  • In this paper, laser vision sensor is used to detect some defects any $co_{2}$ welded specimen in hardware. But, as the best expression of defects of welded specimen, the concept of segment splitting method and mean distance are introduced in software. The developed GUI software is used for deriding whether any welded specimen makes as proper shape or detects in real time. The criteria are based upon ISO 5817 as limits of imperfections in metallic fusion welds.

Geodesic Clustering for Covariance Matrices

  • Lee, Haesung;Ahn, Hyun-Jung;Kim, Kwang-Rae;Kim, Peter T.;Koo, Ja-Yong
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.4
    • /
    • pp.321-331
    • /
    • 2015
  • The K-means clustering algorithm is a popular and widely used method for clustering. For covariance matrices, we consider a geodesic clustering algorithm based on the K-means clustering framework in consideration of symmetric positive definite matrices as a Riemannian (non-Euclidean) manifold. This paper considers a geodesic clustering algorithm for data consisting of symmetric positive definite (SPD) matrices, utilizing the Riemannian geometric structure for SPD matrices and the idea of a K-means clustering algorithm. A K-means clustering algorithm is divided into two main steps for which we need a dissimilarity measure between two matrix data points and a way of computing centroids for observations in clusters. In order to use the Riemannian structure, we adopt the geodesic distance and the intrinsic mean for symmetric positive definite matrices. We demonstrate our proposed method through simulations as well as application to real financial data.

Return of spontaneous circulation rate according to dispatch distance in out-of-hospital cardiac arrest (출동 거리에 따른 병원 전 심장정지 환자의 자발순환회복률 분석)

  • Kim, Jong-Ho;Jeon, Youn-Chel;Moon, Jun-Dong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.2
    • /
    • pp.51-61
    • /
    • 2017
  • Purpose: This study measured return of spontaneous circulation (ROSC) in relation to dispatch distance in patients with out-of-hospital cardiac arrest. Methods: Of 2,347 out-of-hospital cardiac arrest patients transported by emergency medical technicians in J Province between January 1 and December 31, 2015, those under age 18, those with reserved resuscitation, and those with traumatic cardiac arrest, leaving 855 patients in the study sample. ROSC was compared between those with dispatch distance ${\leq}4km$ (short dispatch distance, 465 patients) and those with dispatch distance >4 km (long dispatch distance, 390 patients). Results: The mean was 2.17 km in the short dispatch group and 9.87 km in the long dispatch group (p=.000). Mean distance from was 6.49 km and 13.39 km in the two groups, respectively (p=.000). ROSC differed significantly between the short and long dispatch distance groups (7.1% for short dispatch distance, 3.6% for long dispatch distance, p=.025). The length of time from to cardiopulmonary resuscitation also differed significantly between the short and long dispatch distance groups (8.77 minutes and 14.63 minutes, respectively, p=.000). Conclusion: ROSC was lower in areas of long dispatch distance compared to those of short dispatch distance. We expect this was most likely due to differences in response time by age and dispatch distance to the scene of cardiac arrest. However, no significant differences were found between the groups in the factors affecting ROSC.

Effect of Distance Phoria on Stereoacuity (원거리 사위도가 입체시에 미치는 영향)

  • Chun, Young-Yun;Joo, Seok-Hee;Park, Seong-Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.101-105
    • /
    • 2008
  • Purpose: In this study we measured the mean value of the distance stereoacutiy for adult subjects and evaluated the variation of the distance stereoacuity according to correction of phoria using the Pola Test E-II of Carl Zeiss. Methods: We investigated the distance stereoacuity for 50 adults (male: 29, female: 21) ranging in age from 19 to 46 years using D6 Circle chart and D8 Line chart in the Pola Test E-II. Results: The mean values of the distance stereoacuity measured on the D6 Circle test and D8 Line test were 159.6 and 149.4 seconds of arc respectively. The mean variations of the distance stereoacuity according to correction of phoria in D6 Circle test were increased 43.2 seconds of arc in exophoria and 51 seconds of arc in esophoria, and those in D8 Line test were increased 42 seconds of arc in exophoria and 70.2 seconds of arc in esophoria. Conclusions: We knew from these results that the distance stereoacuity after prescription of phoria improved more esophoria than exophoria.

  • PDF

Spray Characteristics of Fuel Injector in DI Diesel Engine (직접 분사식 디젤 기관 인젝터의 연료 분무 특성)

  • 이창식;김민규;전원식;진다시앙
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.75-81
    • /
    • 2001
  • This paper presents the atomization characteristics of single hole injector in the direct injection type diesel engine. The spray characteristics of fuel injector such as the droplet size and velocity were measured by phase Doppler particle analyzer. In this paper, the atomization characteristics of fuel spray are investigated for the experimental analysis of the measuring data by the results of mean diameter and mean velocity of droplet. The effect of fuel injection pressure on the droplet size shows that the higher injection pressure results in the decrease of mean droplet diameter in the fuel spray. The minimum size of fuel spray droplet appears on the location of 40mm axial distance from nozzle exit of diesel injector. Based on the experimental results, the correlation between the droplet diameter and mean velocity of the diesel spray due to the change of axial and radial distance from the nozzle tip were investigated.

  • PDF

WEIGHTED POSSIBILISTIC VARIANCE AND MOMENTS OF FUZZY NUMBERS

  • Pasha, E.;Asady, B.;Saeidifar, A.
    • Journal of applied mathematics & informatics
    • /
    • v.26 no.5_6
    • /
    • pp.1169-1183
    • /
    • 2008
  • In this paper, a method to find the weighted possibilistic variance and moments about the mean value of fuzzy numbers via applying a difuzzification using minimizer of the weighted distance between two fuzzy numbers is introduced. In this way, we obtain the nearest weighted point with respect to a fuzzy number, this main result is a new and interesting alternative justification to define of weighted mean of a fuzzy number. Considering this point and the weighted distance quantity, we introduce the weighted possibilistic mean (WPM) value and the weighted possibilistic variance(WPV) of fuzzy numbers. This paper shows that WPM is the nearest weighted point to fuzzy number and the WPV of fuzzy number is preserved more properties of variance in probability theory so that it can simply introduce the possibilistic moments about the mean of fuzzy numbers without problem. The moments of fuzzy numbers play an important role to estimate of parameters, skewness, kurtosis in many of fuzzy times series models.

  • PDF