• Title/Summary/Keyword: Mayo

Search Result 161, Processing Time 0.024 seconds

PHILOS Plate Osteosynthesis in Metaphyseal Fractures of the Distal Humerus through an Anterolateral Approach

  • Park, Jung Ho;Kim, Jung Wook;Oh, Chi Hun;Choi, Keun Seok;Hong, Jae Young;Kim, Jae Gyoon
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.128-132
    • /
    • 2015
  • Background: We described a surgical method for osteosynthesis and reported the resultant strength after application of a PHILOS plate through the anterolateral approach for the treatment of fractures of the distal humerus. Methods: Between February 2010 and March 2012, open reduction and internal fixation operations with the PHILOS plate for treatment of fracture of the distal humerus were performed on a total of nine patients (five men, four women). The mean age was 40.8 years (range, 24-50 years), and the average follow-up period was 9.1 months (range, 6-15 months). Clinical evaluations were performed 6 months after the operation. Clinical assessment included determination of the range of motion of the elbow, the Mayo and Oxford elbow scores, and any postoperative complications. Results: Fracture union was noted in all patients, with an average period of 12.4 weeks. The average Mayo elbow and Oxford elbow scores were 87.2 (of a total of 100) and 43.3 (of a total of 48), respectively. For the postoperative range of motion of the elbow, all patients showed complete recovery to the preoperative range of motion. No other conditions, such as neurolepsis, plate breakage, or rotational deformity, were observed. Conclusions: Open reduction and internal fixation of distal humerus fractures with a PHILOS plating system via anterolateral approach can be effective. A high rate of union with good outcomes can be assumed.

Does Low-Dose Heparin Have a Significant Role in Free Flap Surgery?

  • An, Mun-Young;Shin, Jin Yong;Lee, Young-Keun;Sabbagh, M. Diya;Roh, Si-Gyun;Lee, Nae-Ho
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.3
    • /
    • pp.162-165
    • /
    • 2017
  • Background: It is controversial issue that heparin decreases thrombosis for microsurgical anastomosis, and its effective role is under discussion. This study is for proving whether low-dose heparin is preventing thrombosis in free flap reconstruction. Methods: Through chart reviews of 134 patients, using low-dose heparin for free tissue transfer from 2011 to 2016, retrospective analysis was performed. 33 patients received low-dose heparin therapy after surgery. And 101 patients received no-heparin therapy. Complications included flap necrosis, hematoma formation, dehiscence and infection. Results: In no-heparin therapy group, comparing the flap necrosis revealed 16 cases (15.84%). And, flap necrosis was 6 cases (18.18%) in low-dose heparin therapy group. The statistical analysis of flap necrosis rate showed no significant difference (p=0.75). The results showed that there was no significant difference of flap necrosis rate between two groups. Conclusion: In this study, patients in the low-dose heparin group had no significantly lower rates of flap failure compared with no-heparin group. This suggests that low-dose heparin may not prevent thrombosis and subsequent flap failure to a significant extent.

Poor Prognostic Implication of ASXL1 Mutations in Korean Patients With Chronic Myelomonocytic Leukemia

  • Kim, Hyun-Young;Lee, Ki-O;Park, Silvia;Jang, Jun Ho;Jung, Chul Won;Kim, Sun-Hee;Kim, Hee-Jin
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.495-502
    • /
    • 2018
  • Background: Molecular genetic abnormalities are observed in over 90% of chronic myelomonocytic leukemia (CMML) cases. Recently, several studies have demonstrated the negative prognostic impact of ASXL1 mutations in CMML patients. We evaluated the prognostic impact of ASXL1 mutations and compared five CMML prognostic models in Korean patients with CMML. Methods: We analyzed data from 36 of 57 patients diagnosed as having CMML from January 2000 to March 2016. ASXL1 mutation analysis was performed by direct sequencing, and the clinical and laboratory features of patients were compared according to ASXL1 mutation status. Results: ASXL1 mutations were detected in 18 patients (50%). There were no significant differences between the clinical and laboratory characteristics of ASXL1-mutated ($ASXL1^+$) CMML and ASXL1-nonmutated ($ASXL1^-$) CMML patients (all P >0.05). During the median follow-up of 14 months (range, 0-111 months), the overall survival (OS) of $ASXL1^+$ CMML patients was significantly inferior to that of $ASXL1^-$ CMML patients with a median survival of 11 months and 19 months, respectively (log-rank P =0.049). An evaluation of OS according to the prognostic models demonstrated inferior survival in patients with a higher risk category according to the Mayo molecular model (log-rank P =0.001); the other scoring systems did not demonstrate a significant association with survival. Conclusions: We demonstrated that ASXL1 mutations, occurring in half of the Korean CMML patients examined, were associated with inferior survival. ASXL1 mutation status needs to be determined for risk stratification in CMML.

Influence of lateralized versus medialized reverse shoulder arthroplasty design on external and internal rotation: a systematic review and meta-analysis

  • Kevin A. Hao;Robert J. Cueto;Christel Gharby;David Freeman;Joseph J. King;Thomas W. Wright;Diana Almader-Douglas;Bradley S. Schoch;Jean-David Werthel
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.59-71
    • /
    • 2024
  • Background: Restoration of external (ER) and internal rotation (IR) after Grammont-style reverse shoulder arthroplasty (RSA) is often unreliable. The purpose of this systematic review was to evaluate the influence of RSA medio-lateral offset and subscapularis repair on axial rotation after RSA. Methods: We conducted a systematic review of studies evaluating axial rotation (ER, IR, or both) after RSA with a defined implant design. Medio-lateral implant classification was adopted from Werthel et al. Meta-analysis was conducted using a random-effects model. Results: Thirty-two studies reporting 2,233 RSAs were included (mean patient age, 72.5 years; follow-up, 43 months; 64% female). The subscapularis was repaired in 91% (n=2,032) of shoulders and did not differ based on global implant lateralization (91% for both, P=0.602). On meta-analysis, globally lateralized implants achieved greater postoperative ER (40° [36°-44°] vs. 27° [22°-32°], P<0.001) and postoperative improvement in ER (20° [15°-26°] vs. 10° [5°-15°], P<0.001). Lateralized implants with subscapularis repair or medialized implants without subscapularis repair had significantly greater postoperative ER and postoperative improvement in ER compared to globally medialized implants with subscapularis repair (P<0.001 for both). Mean postoperative IR was reported in 56% (n=18) of studies and achieved the minimum necessary IR in 51% of lateralized (n=325, 5 cohorts) versus 36% (n=177, 5 cohorts) of medialized implants. Conclusions: Lateralized RSA produces superior axial rotation compared to medialized RSA. Lateralized RSA with subscapularis repair and medialized RSA without subscapularis repair provide greater axial rotation compared to medialized RSA with subscapularis repair. Level of evidence: 2A.

Adverse Events in Total Artificial Heart for End-Stage Heart Failure: Insight From the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE)

  • Min Choon Tan;Yong Hao Yeo;Jia Wei Tham;Jian Liang Tan;Hee Kong Fong;Bryan E-Xin Tan;Kwan S Lee;Justin Z Lee
    • International Journal of Heart Failure
    • /
    • v.6 no.2
    • /
    • pp.76-81
    • /
    • 2024
  • Background and Objectives: Real-world clinical data, outside of clinical trials and expert centers, on adverse events related to the use of SyncCardia total artificial heart (TAH) remain limited. We aim to analyze adverse events related to the use of SynCardia TAH reported to the Food and Drug Administration (FDA)'s Manufacturers and User Defined Experience (MAUDE) database. Methods: We reviewed the FDA's MAUDE database for any adverse events involving the use of SynCardia TAH from 1/01/2012 to 9/30/2020. All the events were independently reviewed by three physicians. Results: A total of 1,512 adverse events were identified in 453 "injury and death" reports in the MAUDE database. The most common adverse events reported were infection (20.2%) and device malfunction (20.1%). These were followed by bleeding events (16.5%), respiratory failure (10.1%), cerebrovascular accident (CVA)/other neurological dysfunction (8.7%), renal dysfunction (7.5%), hepatic dysfunction (2.2%), thromboembolic events (1.8%), pericardial effusion (1.8%), and hemolysis (1%). Death was reported in 49.4% of all the reported cases (n=224/453). The most common cause of death was multiorgan failure (n=73, 32.6%), followed by CVA/other non-specific neurological dysfunction (n=44, 19.7%), sepsis (n=24, 10.7%), withdrawal of support (n=20, 8.9%), device malfunction (n=11, 4.9%), bleeding (n=7, 3.1%), respiratory failure (n=7, 3.1%), gastrointestinal disorder (n=6, 2.7%), and cardiomyopathy (n=3, 1.3%). Conclusions: Infection was the most common adverse event following the implantation of TAH. Most of the deaths reported were due to multiorgan failure. Early recognition and management of any possible adverse events after the TAH implantation are essential to improve the procedural outcome and patient survival.

Double Tension Band Osteosynthesis in Intra-articular Fractures of the Distal Humerus (AO type C) in Elderly Osteoporotic Patients (고령 환자의 상완골 원위부 AO-C형 골절에서 이중 강선 장력대 고정술)

  • Cheon, Sang Jin;Lee, Dong Ho;Goh, Tae Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.33-39
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the clinical result of intra-articular fractures of the distal humerus (AO type C) in elderly osteoporotic patients treated with double tension band osteosynthesis. Materials and Methods: From January 2006 to December 2010, 10 elderly osteoporotic patients(1 male, 9 females) with intra-articular fractures of the distal humerus (AO type C) were treated with double tension band osteosynthesis. The mean age of patients at the time of surgery was 74.6(66~84) years and the mean follow-up period was 39.2(20~74) months. The fracture union and complications were assessed and the functional result was evaluated by the rating system of Jupiter et al. and the Mayo elbow performance index. Results: Bone union was achieved in all patients with no secondary displacement. The mean time for union was 16.6(13~22) weeks. The average postoperative arc of elbow flexion was 119(100~140) degrees with a mean flexion contracture of 8.5(0~15) degrees. The recovery in two patients was rated as excellent, in 7 as good, and in 1 as fair in terms of the Mayo elbow performance index with average value of 82(70~90) points. Seven patients were rated as excellent, 1 as good, and 2 as fair in terms of the rating system of Jupiter et al. Changing tension band wiring was performed in one patient as skin irritation was noticed due to tension band knots. Heterotopic ossification developed in one patient but had no symptom. Conclusion: Double tension band osteosynthesis in intra-articular fractures of distal humerus (AO type C) in elderly osteoporotic patients can provide sufficient and secure stability to allow early rehabilitation.

Multidimensional Adaptive Noise Cancellation of Stress ECG Signal

  • Gautam, Alka;Lee, Young-Dong;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.285-288
    • /
    • 2008
  • In ubiquitous computing environment the biological signal ECG (Electrocardiogram signal) is usually recorded with noise components. Adaptive interference (or noise) canceller do adaptive filtering of the noise reference input to maximally match and subtract out noise or interference from the primary (signal plus noise) input thereby adaptively eliminate unwanted interference from the ECG signal. Measured Stress ECG (or exercise ECG signal) signal have three major noisy component like baseline wander noise, motion artifact noise and EMG (Electro-mayo-cardiogram) noise. These noises are not only distorted signal but also root of incorrect diagnosis while ECG data are analyzed. Motion artifact and EMG noises behave like wide band spectrum signals, and they considerably do overlapping with the ECG spectrum. Here the multidimensional adaptive method used for filtering which is more effective to improve signal to noise ratio.

  • PDF

Paraesophageal Hernia with Gastric Erosion - A Case Report - (식도주위 열공 탈장에서 병발한 위미란의 치험)

  • Baek, Hong-Gyu;Yu, Hoe-Seong
    • Journal of Chest Surgery
    • /
    • v.26 no.4
    • /
    • pp.337-341
    • /
    • 1993
  • Since the first deliberate repair of hiatal hernia by Wm. J. Mayo in 1911, counterless procedure have been performed to correct herniation of the stomach into the posterior mediastinum. Recently,we experienced 51 years old female patient with large paraesophageal hernia and complete intrathoracic stomach which combined with multiple gastric erosion with chronic blood loss. So gastric ulcer within a diaphragmatic hernia is a distinct physiophathologic and clinical entity that our patient suffered from severe anemia due to chronic blood loss. The hernia was repaired transabdominally including reduction of stomach, excision of sac, closure of defect, anterior gastropexy, and gastr6stomy. Because of absent gastroesophageal refiux, no another antireflux procedure was required and erosion was managed by H2 receptor blocker.

  • PDF

미국과 유럽, 드론 산업정책과 규제정책에서 서로 다른 길을 걷다

  • Gang, Jeong-Su
    • The Optical Journal
    • /
    • s.158
    • /
    • pp.61-64
    • /
    • 2015
  • 드론(drone)이라 불리는 무인항공기(UAV)가 무인전투기, 무인정찰기 등 군사용도를 벗어나 일상생활의 다양한 영역에서 그 쓰임새를 빠르게 찾아가고 있다. 미국 아마존과 구글, 독일 DHL, 중국 알리바바 등이 배달전용 드론을 시범 운영하고 있다. 미국 미네소타 주에 위치한 메이요(Mayo) 병원은 주변 소재 작은 병원에 수혈용 피를 운반하는데 드론을 이용하고 있다. 미국의 경우 수혈용 피 대부분이 대형 병원에 비축되어 있다. 지역의 작은 병원의 경우 1-2명의 환자를 위한 응급 피를 보관하고 있을 뿐이다. 이런 상황에서 혈액 배달 드론은 유용하게 기능할 수 있다. 그렇다고 벌떼처럼 드론이 도심을 떠다니는 일은 당분간 없을 것이다. 미국의 경우 드론사업과 관련하여 현재까지 매우 엄격한 '사전허가'가 요구된다. 그 누구도 하늘을 떠다니는 드론이 폭풍과 같은 기상 이변을 만나 자신의 머리 위로 또는 주택 위로 떨어지는 것을 원치 않기 때문이다.

  • PDF

A Case Report of Intra-articular Bee Venom Pharmacopuncture for Partial Tear of Triangular Fibrocartilage Complex. (삼각 섬유연골 복합체 부분 파열에 대한 관절강내 봉약침 시술 치험 1례)

  • Lee, Kwang-Ho;Ryu, Young-Jin;Sun, Seung-Ho;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.12 no.4
    • /
    • pp.127-134
    • /
    • 2009
  • Objective: This case was to report a case of Partial Tear of Triangular Fibrocartilage Complex treated by Intra-articular bee venom Pharmacopuncture. Methods: The patient was treated by Intra-articular bee venom Pharmacopuncture. The Effect of Treatment was evaluated by Visual Analog Scale(VAS) and Modified Mayo Wrist Score(Wrist Score). Results & Conclusions: After Treatment, Patient's VAS decreased and Wrist Score increased. For this results, Intra-articular Bee Venom Pharmacopuncture may be effective for Partial Tear of Triangular Fibrocartilage Complex.