• 제목/요약/키워드: Maximum-Minimum Temperature Difference

검색결과 129건 처리시간 0.029초

농업용 비닐하우스의 온풍난방에 관한 기초적 연구 (Study on the Vinyl House Heating by Warm Air)

  • 조진구;이근후
    • 한국농공학회지
    • /
    • 제19권3호
    • /
    • pp.4483-4491
    • /
    • 1977
  • The results obtained are as follows; 1. The variation of the temperature in a vinyl house without heating system is similar to that of air temperature in a day. The difference of maximum temperature and minimum one in a day is 27$^{\circ}C$ which is two times greater than the daily difference of air temperature. 2. When the length of the duct is increased, the high temperature zone is built up in the direction of warm air discharge from the duct, and the low temperature zone is built up in the opposite direction of warm air discharge. But, in case of the duct length is short (0.05 L), the temperature distrubution in a vinyl house become uniform. It is concluded that the shorter length of the duct, the better the distribution of the temperature in a vinyl house is. 3. When the duct is installed at high position, the high temperature zone is built up in the upper zone of the vinyl house and the low temperature zone is built up in the lower zone. And when the position of the duct is low, the rate of temperature variation along the vertical direction become high, and the direct contact of warm air with the plant in the house is occured. It is concluded that the duct should be installed at the position of slightly higher than the plant height. 4. When the fuel consumption rate is fixed at the 101/hr, the lowest temperature warming rate in the vinyl house is 5$^{\circ}C$ without regard to the air temperature.

  • PDF

딸기재배 스마트 온실용 온습도 계측시스템의 성능평가 (Analyzing the Performance of a Temperature and Humidity Measuring System of a Smart Greenhouse for Strawberry Cultivation)

  • 정영균;이종구;안은기;서재석;김현태;윤용철
    • 생물환경조절학회지
    • /
    • 제28권2호
    • /
    • pp.117-125
    • /
    • 2019
  • 본 연구는 기존에 사용하여 왔고, 최근에 온습도의 정확도를 검증하였던 강제 흡출식 복사선 차폐장치(Aspirated Radiation Shield; ARS)와 모 기업(A 회사)에서 개발한 시스템으로 측정한 온습도를 비교하여 성능을 검토한 후, 시스템의 성능을 개선할 목적으로 수행되었다. 그 결과를 요약하면 다음과 같다. 딸기의 무성도가 두 계측시스템에 영향을 미친 경우를 제외하면, 전체적으로 볼 때 플레이트 2개의 시스템이 1개보다 복사선 차폐효과가 미미하지만 좋은 것으로 나타났다. 그리고 A회사의 시스템과 ARS장치로 측정한 최고온도의 전체적인 범위는 각각 $20.5{\sim}53.3^{\circ}C$$17.8{\sim}44.1^{\circ}C$정도로써 A사 제품이 $2.7{\sim}9.2^{\circ}C$정도 높게 나타났고, 일별 최대 편차는 $12.2^{\circ}C$ 정도였다. 평균온도의 경우, 두 기관의 전체적인 범위는 각각 $12.4{\sim}38.6^{\circ}C$$11.8{\sim}32.7^{\circ}C$정도로써 A사 시스템이 $0.6{\sim}5.9^{\circ}C$정도 높게 나타났고, 일별 최대 편차는 $6.7^{\circ}C$정도였다. 최저온도의 경우도 각각 $4.2{\sim}28.6^{\circ}C$$2.9{\sim}26.4^{\circ}C$정도로써 A사 제품이 $1.3{\sim}2.2^{\circ}C$정도 높게 나타났고, 일별 최대 편차는 $2.9^{\circ}C$정도로써 두 기관의 장치로 측정한 온도에 편차가 있는 것으로 나타났다. 또한 상대습도의 경우, A회사와 ARS장치로 측정한 평균상대습도의 전체적인 범위는 각각 52.9~93.3% 및 55.3~96.5%정도로써 A회사의 시스템이 ARS장치보다 2.4~3.2%정도 낮게 나타나는 경향을 보였다. 그러나 일별로 비교하여 보면, 최대 18.0%정도 A회사의 시스템이 낮게 나타나는 날도 있었다. 결국 상대습도도 온도와 마찬가지로 미미하긴 하지만 두 기관의 장치로 측정한 온도에 편차가 있는 것으로 나타났다.

운동에너지탄에 의한 전투시스템의 순간화재 발생가능성에 대한 연구 (A Study on The Possibility of Flash Fire of Combat System by Kinetic Energy Ammunitions)

  • 박영주;이은민;이해평;황미정;이창현
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.89-97
    • /
    • 2014
  • This study analyzed various possibilities of flash fire which could occur in a variety of combats, in order to predict that of flash fire of combat system armor using Autodyn program. The possibility was judged by the temperature distribution of fuels, which was caused by the impact of parts of fuel systems through an armor, in the event of getting shot by external ammunition. Diverse variables could affect the possibility of flash fire: external ammunition(Type A: penetration 570 mm, Type B: penetration 410 mm), fuels(Gasoline, Diesel, Kerosene), the thickness of an armor(100, 200, 300, 400, 500 mm), the gap of a fuel tank and an armor(45, 95, 145, 195, 245, 295 mm). As a result, when an armor was 20 mm think, the temperature of 3 fuels ranged like this: Gasoline 372~387 K, Diesel 442~408 K, Kerosene 384~395 K. Although they made a little difference among them, they all didn't reach their ignition points. When an armor was 200 mm think, each fuel reached the maximum temperature, not reaching its ignition points as well. The thicker an armor was, the lower the temperature got. When Type B ammunition was used, the temperature of fuels went up 19~59 K higher than Type A was used. In the case that the gap of fuel tank and an armor was 20 mm thick, the temperature distribution of Gasoline showed 389~450 K, the maximum temperature appeared in the gap of 145 mm, and the minimum temperature 295 mm. For Type B, the temperature distribution of fuels ranged 386~401 K, the maximum temperature appeared in the gap of 245 mm, and the minimum temperature 45 mm. There was no significant difference between two cases, and neither of them reached its ignition point. Accordingly, as the tested fuels of combat systems didn't reach their ignition points, it is thought that the possibility of flash point of an armor is low.

외기 온도와 난방 출력의 철도차량 객실 온도에 대한 영향 연구 (Study of the Effects of Ambient Temperature and Car Heater Power on the Train Cabin Temperature)

  • 조영민;박덕신;권순박;정우성
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5877-5884
    • /
    • 2014
  • 최근 기후변화와 기상이변 등으로 동절기에 더욱 가혹한 기상 조건이 자주 보고되고 있다. 그러나, 철도차량의 난방용량은 이렇게 극도로 추운 기후환경에서는 객실을 난방하기에 충분하지 않은 경우가 많으며, 이는 난방에 대한 승객의 민원을 야기하는 주요 원인이 되고 있다. 본 연구에서는 외기 온도와 난방 출력이 객실 온도에 미치는 영향을 알아봄으로써 차량의 난방용량에 따른 운행 가능한 외기온도를 실험적으로 도출하고자 하였다. 실험방법으로는 우선 시험용 철도차량을 대형 기후환경 챔버에 넣고, 다양한 외기온도조건을 모사하였다. 난방 장치 출력의 영향은 난방 장치의 출력을 변화시키면서 객실의 온도를 측정하여 조사하였다. 외기온도가 $-10^{\circ}C$인 조건에서는 난방기의 출력을 최대로 한 경우에도 객실의 평균 온도는 $14.0^{\circ}C$에 불과하여, 동절기의 객실온도 최소 요구조건인 $18^{\circ}C$보다 훨씬 낮았으나, 외기 온도가 $0^{\circ}C$$10^{\circ}C$인 경우의 객실온도는 각각 $26.1^{\circ}C$$34.0^{\circ}C$였다. 내삽법으로 계산한 결과 객실 내부 온도를 $18^{\circ}C$ 이상으로 유지할 수 있는 최저 외기온도는 $-6.7^{\circ}C$임을 알 수 있었다. 객실 내부에서의 수직 온도 차이는 난방기 출력이 높을수록, 외기온도가 높을수록 커서 10 K 이상 차이가 나는 경우도 있었다. 그러나, 수평 온도 차이는 난방기 출력이나 외기온도에 무관하게 최대 2 K 이하로 매우 낮게 나타났다. 따라서, 우수한 난방성능을 확보하기 위해서는 수직 온도 차이를 줄이는 것이 중요함을 알 수 있었다.

Effect of cold stress on infanticide by female Swiss albino mice Mus musculus: a pilot study

  • Zafar, Tabassum;Naik, Ab Qayoom;Shrivastava, Vinoy K.
    • Journal of Animal Science and Technology
    • /
    • 제60권4호
    • /
    • pp.7.1-7.5
    • /
    • 2018
  • Background: Mice are widely accepted research models of great clinical significance. Maintenance of laboratory mice breed is an essential aspect for performing research activities in various fields of science. Infanticide is one of the prominent causes of litter loss during maintenance of laboratory mice stock. The present study is an effort to monitor the effect of change in ambient temperature of female mice below the normal range on cannibalism and infanticide during early postparturition phase. Adult female Swiss albino mice have been divided into two groups of control and treatment. On the day of litter group one was maintained under controlled temperature conditions (minimum $20^{\circ}C$ to maximum $23^{\circ}C$) throughout, while female mice belong to group two have been exposed to variation of room temperature (maximum $15^{\circ}C$ to minimum $10^{\circ}C$ for two nights and one day) until 36 h postparturition. Results: The effects of temperature changes were observed on the infanticide behaviour of dams along with the survival of pups in early postparturition phase till 36 h after delivery. The significant statistical difference (P < 0.05) was reported in infanticide behaviour of dams when control and treatment group was compared. It is observed that decrement in surrounding temperature promotes decrement in the ambient body temperature of dams during early postparturition. It is proposed that alteration of hypothalamic homeostasis due to temperature change induces cannibalism and infanticide behaviour. Lack of thermoregulation during early postparturition creates the sense of insecurity, in-satiety, anxiety and stress. Conclusions: Authors strongly recommend the maintenance of body and surrounding temperature to prevent infanticidal behaviour and cannibalism within Swiss albino mice population. Further investigations are advisable to authenticate the active behavioural and biochemical pathway behind the phenomena.

자동기상관측소의 국지기후대에 근거한 서울 도시 열섬의 공간 분포 (Spatial Distribution of Urban Heat Island based on Local Climate Zone of Automatic Weather Station in Seoul Metropolitan Area)

  • 홍제우;홍진규;이성은;이재원
    • 대기
    • /
    • 제23권4호
    • /
    • pp.413-424
    • /
    • 2013
  • Urban Heat Island (UHI) intensity is one of vital parameters in studying urban boundary layer meteorology as well as urban planning. Because the UHI intensity is defined as air temperature difference between urban and rural sites, an objective sites selection criterion is necessary for proper quantification of the spatial variations of the UHI intensity. This study quantified the UHI intensity and its spatial pattern, and then analyzed their connections with urban structure and metabolism in Seoul metropolitan area where many kinds of land use and land cover types coexist. In this study, screen-level temperature data in non-precipitation day conditions observed from 29 automatic weather stations (AWS) in Seoul were analyzed to delineate the characteristics of UHI. For quality control of the data, gap test, limit test, and step test based on guideline of World Meteorological Organization were conducted. After classifying all stations by their own local climatological properties, UHI intensity and diurnal temperature range (DTR) are calculated, and then their seasonal patterns are discussed. Maximum UHI intensity was $4.3^{\circ}C$ in autumn and minimum was $3.6^{\circ}C$ in spring. Maximum DTR appeared in autumn as $3.8^{\circ}C$, but minimum was $2.3^{\circ}C$ in summer. UHI intensity and DTR showed large variations with different local climate zones. Despite limited information on accuracy and exposure errors of the automatic weather stations, the observed data from AWS network represented theoretical UHI intensities with difference local climate zone in Seoul.

최근 2년간 서울 선정릉 지역의 복합센서 관측망을 활용한 녹지 냉각효과 분석 (Analyzing the Cooling Effect of Urban Green Areas by Using the Multiple Observation Network in the Seonjeongneung Region of Seoul, Korea)

  • 김근회;이영곤;이대근;김백조
    • 한국환경과학회지
    • /
    • 제25권11호
    • /
    • pp.1475-1484
    • /
    • 2016
  • To analyze the cooling effect of urban green areas, we conducted micrometeorological measurements in these areas and their surroundings in Seoul, Korea. From the average hourly temperature measurements through each month for the last two years (March 2013 to February 2015), we found that the maximum temperature difference between urban and green areas was about $2.9^{\circ}C$ at 16:00 LST in summer, and the minimum was about $1.7^{\circ}C$ at 22:00 LST in winter. In summer, the temperature difference was the largest during the day, rather than at night, due mainly to shading by the tree canopy. The specific humidity difference between the two areas was about $1.5g\;kg^{-1}$ in summer, and this decreased in the winter. The specific humidity difference between urban and green areas in summer is relatively large during the day, due to the higher evapotranspiration level of biologically active plants.

Membrane distillation of power plant cooling tower blowdown water

  • Ince, Elif;Uslu, Yasin Abdullah
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.321-330
    • /
    • 2019
  • The objective of this study was to examine the recovery of the power plant cooling tower blowdown water (CTBD) by membrane distillation. The experiments were carried out using a flat plate poly vinylidene fluoride (PVDF) membrane with a pore diameter of $0.22{\mu}m$ by a direct contact membrane distillation unit (DCMD). The effects of operating parameters such as transmembrane temperature difference (${\Delta}T$), circulation rate and operating time on permeate flux and membrane fouling have been investigated. The results indicated that permeate flux increased with increasing ${\Delta}T$ and circulation rate. Whereas maximum permeate flux was determined as $47.4L/m^2{\cdot}h$ at ${\Delta}T$ of $50^{\circ}C$ for all short term experiments, minimum permeate flux was determined as $7.7L/m^2{\cdot}h$ at ${\Delta}T$ of $20^{\circ}C$. While $40^{\circ}C$ was determined as the optimum ${\Delta}T$ in long term experiments. Inorganic and non-volatile substances caused fouling in the membranes.

알루미늄 합금재의 마찰교반용접 유한요소해석에 관한 연구 (A Study on the Finite Element Analysis in Friction Stir Welding of Al Alloy)

  • 이대열;박경도;강대민
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.81-87
    • /
    • 2015
  • In this paper, the finite element method was used for the flow and strength analysis of aluminum alloy under friction stir welding. The simulations were carried out using Sysweld s/w, and the modeling of the sheet was executed using Unigraphics NX6 s/w. The welding variables for the analysis were the shoulder diameter, rotating speed, and welding speed of the tool. Additionally, a three-way factorial design method was applied to confirm the effect of the welding variables on the flow and strength analysis with variance analysis. From these results, the rotating speed had the greatest influence on the maximum temperature, and the maximum temperature was $578.84{\pm}12.72$ at a confidence interval of 99%. The greater the rotating speed and shoulder diameter, the greater the difference between maximum and minimum temperature. Furthermore, the shoulder diameter had the largest influence on von Mises stress, and the von Mises stress was $184.54{\pm}12.62$ at a confidence interval of 99%. In addition to the increased shoulder diameter, welding speed, and rotating speed of the tool increased the von Mises stress.

서울에서 1954-2005년 동안 관측된 설날 귀성에 따른 일교차의 변화 (Changes in the Diurnal Temperature Range due to Homecoming in the New Year Holiday Observed in Seoul for the 1954-2005 Period)

  • 허창회
    • 대기
    • /
    • 제16권1호
    • /
    • pp.49-53
    • /
    • 2006
  • The present study has examined interdecadal variations of the diurnal temperature range (DTR, daily maximum temperature minus daily minimum temperature) during the New Year season in Seoul for the period 1954-2005. Here, the average DTR for the New Year holidays (three consecutive days; one day before the New Year, the New Year day, and one day after the New Year) minus the average DTR for 14 days, 7 days before and 7 days after the New Year holidays, is defined for representing the New Year effect. The DTR index does not show notable trend until the late 1970s but shows obvious positive values afterward. For example, the difference of the average DTR between two periods (1980-2005 minus 1954-1979) is $0.65^{\circ}C$, which is meaningful at the 95% confidence level. This result demonstrates that intense human activity even for the limited period may provide climate impact in local regions. Its plausible causes are discussed.