• 제목/요약/키워드: Maximum stress

검색결과 3,528건 처리시간 0.059초

Design optimization of the outlet holes for bone crystal growing with bioactive materials in dental implants: Part II. number and shapes

  • Lee, Kangsoo;Kim, Geug Tae;Lee, Yong Keun
    • 한국결정성장학회지
    • /
    • 제23권2호
    • /
    • pp.76-80
    • /
    • 2013
  • For further improvement of osseo-integration of bone crystal with a dental implant, a design optimization study is carried out for various holes inside its body to deliver bioactive materials and the effect of bioactive material injection on the bone crystal growing. When bioactive material is absorbed, the bone crystal can grow into holes, which would increase the strength of implant bonding as well as a surface integration. The stress concentrations near the uppermost outlet holes were reduced with increasing the number of outlet holes. A design improvement in the uppermost outlet was shown to be effective in reducing the stress concentration. For design parameters under consideration in this study, total area of outlet of 6.38 $mm^2$ and maximum stress of 1.114 MPa, which corresponds to type 6-C. It is due to the minimization of maximum stress and total area of outlet. The design of the outlet facing down was more effective in reducing the maximum stress value compared with a horizontal symmetry.

헬기의 진동과 피로에 대한 내구성 연구 (Study on Durability by Vibration and Fatigue of the Helicopter)

  • 한문식;조재웅
    • 한국기계가공학회지
    • /
    • 제10권6호
    • /
    • pp.63-69
    • /
    • 2011
  • This study analyzes stress, fatigue and vibration on main rotor and body of helicopter. The maximum stress is shown on adjoint part between body and main rotor at the lower position of main rotor. As the maximum displacement amplitude is happened at 4000Hz, there is no resonance and the state of helicopter becomes safe at hovering without the abnormal air current and the disabled rotor. Among the cases of nonuniform fatigue loads, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sample history' becomes most stable. In case of 'Sample History' with the average stress of 0MPa to $-10^5MPa$ and the amplitude stress of 0MPa to $8.539{\times}10^5MPa$, the possibility of maximum damage becomes 3%. This stress state can be shown with 5 times more than the damage possibility of 'SAE bracket history' or 'SAE transmission'. The structural result of this study by using the analysis of vibration and fatigue can be effectively utilized for safe and durable design of helicopter.

자전거 브레이크에서의 디스크 로터의 형상별 열응력 해석 (Thermal Stress Analysis of Disk Rotor by Configuration of Bike Brake)

  • 한문식;조재웅
    • 한국자동차공학회논문집
    • /
    • 제23권3호
    • /
    • pp.287-291
    • /
    • 2015
  • This study investigates the result of thermal stress analysis on disk rotor by classes at bike brake. In the analysis result of thermal deformation at the steady state, maximum deformations at models 1, 2 and 3 are 0.14347mm, 0.15823mm and 0.16028mm respectively. The deformation becomes larger as the field goes on from the center to the outside at disk rotor. As there are models 1, 2 and 3 in the order of maximum deformation, model 1 has safest among three models. In the analysis result of thermal stress at steady and transient states, there are models 1, 2 and 3 in the order of maximum stress. Model 1 becomes most excellent on strength and safety among three models. By using the analysis result of disk rotor model at bike disk, it is possible to design the model applied practically at the safe driving of bike.

Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study

  • Mirac Berke Topcu, Ersoz;Emre, Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.346-359
    • /
    • 2022
  • PURPOSE. Four and six implant-supported fixed full-arch prostheses with various framework materials were assessed under different loading conditions. MATERIALS AND METHODS. In the edentulous maxilla, the implants were positioned in a configuration of four to six implant modalities. CoCr, Ti, ZrO2, and PEEK materials were used to produce the prosthetic structure. Using finite element stress analysis, the first molar was subjected to a 200 N axial and 45° oblique force. Stresses were measured on the bone, implants, abutment screw, abutment, and prosthetic screw. The Von Mises, maximum, and minimum principal stress values were calculated and compared. RESULTS. The maximum and minimum principal stresses in bone were determined as CoCr < ZrO2 < Ti < PEEK. The Von Mises stresses on the implant, implant screw, abutment, and prosthetic screws were determined as CoCr < ZrO2 < Ti < PEEK. The highest Von Mises stress was 9584.4 Mpa in PEEK material on the prosthetic screw under 4 implant-oblique loading. The highest maximum principal stress value in bone was found to be 120.89 Mpa, for PEEK in 4 implant-oblique loading. CONCLUSION. For four and six implant-supported structures, and depending on the loading condition, the system accumulated different stresses. The distribution of stress was reduced in materials with a high elastic modulus. When choosing materials for implant-supported fixed prostheses, it is essential to consider both the number of implants and the mechanical and physical attributes of the framework material.

자전거 프레임 튜브 두께에 따른 구조적 내구성 해석 (Structural Durability Analysis According to the Thickness of Bicycle Frame Tube)

  • 조재웅;한문식
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.122-129
    • /
    • 2012
  • This study investigates structural and vibration analyses according to the thickness of bicycle frame tube. The model of bicycle frame has the dimension as length of 862mm, width of 100mm and hight of 402.5mm. There are 3 kinds of models with tubes of top, down and seat at bicycle frame as thicknesses of 10, 15 and 20mm. The maximum displacement and stress occur at the center part of seat stay and at the installation part of rear wheel respectively. Maximum displacements become 0.031936, 0.029159 and 0.027984mm in cases of thicknesses of 10, 15 and 20mm respectively. In case of thickness of 20mm among 3 cases, maximum displacement becomes lowest. But maximum stresses become 10.019, 8.5492 and 9.2511MPa in cases of thicknesses of 10, 15 and 20mm respectively. In case of thickness of 15mm among 3 cases, maximum stress becomes lowest. There is no resonance at practical driving conditions and natural frequency remains almost unchanged along the change of thickness. In case of the displacement due to vibration mode, the displacement difference at thickness between 15mm and 20mm becomes 1/2 times than that between 10mm and 15mm. Design at bicycle frame tube becomes most economical and durable effectively in case of thickness of 15mm among 3 cases.

Methacrylate 기질 복합레진과 Silorane 기질 복합레진의 치아 수복 시 중합수축응력거동 (Behavior of Polymerization Shrinkage Stress of Methacrylate-based Composite and Silorane-based Composite during Dental Restoration)

  • 박정훈;최낙삼
    • Composites Research
    • /
    • 제28권1호
    • /
    • pp.6-14
    • /
    • 2015
  • 치아의 수복에 사용되는 재료인 Methacrylate 기질 복합레진(Clearfil AP-X)과 Silorane 기질 복합레진(Filtek P90)을 대상으로 스트레인게이지법과 FEM 분석법으로 중합수축응력거동을 분석하였다. 또한 복합레진의 탄성계수와 수축변형률을 중합수축응력과 관계시켜 이론식을 제시하고 이 식의 계산결과와 FEM 분석법의 결과를 비교하였다. 스트레인 게이지법으로 측정한 결과, 중합수축응력의 최대값은 Clearfil AP-X가 Filtek P90 보다 약 2.8배 높게 나타났다. FEM 분석 결과, Von-Mises 응력은 복합레진 수복재와 PMMA 링사이의 계면부에서 최대로 되었으며 시편표면의 계면부가 내부보다 응력집중이 더 컸음을 알았다. 예측식을 통한 반경 방향의 수축응력은 평면응력상태의 FEM 분석법을 통한 값과 비교하여 오차 5% 이내로 정확했음을 확인하였다.

여자 경찰 기동대원의 직무 스트레스, 건강증진행위와 삶의 질의 관련성 (Association of Job Stress and Health Promotion Behaviors with Quality of Life among Female Riot Police Officers)

  • 류기욱;최모나
    • 한국직업건강간호학회지
    • /
    • 제28권4호
    • /
    • pp.187-196
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the association of job stress and health promotion behaviors with the quality of life in female riot police officers. Methods: A cross-sectional design was adopted, and a convenience sample of 182 female riot police officers from 5 Metropolitan Police Agencies in South Korea. All participants completed a self-administered survey questionnaire that assessed job stress, health promotion behavior, and quality of life in May 2018. The collected data were analyzed using t-test, analysis of variance, and correlation and multiple linear regression analyses, all of which were executed using SPSS/WIN 23.0 and STATA 13.0. Results: The level of job stress among participants was moderate, and the mean was 45.25 out of a maximum possible score of 100. The mean scores that emerged for health promotion behaviors and the quality of life were 2.62 (maximum=4) and 56.59 (maximum=100), respectively. Job stress (r=-.380, p<.001) and health promotion behaviors (r=.559, p<.001) were correlated with the quality of life. The statistically significant predictors of the quality of life were job stress (${\beta}=-.212$, p=.001) and health promotion behaviors (${\beta}=.417$, p<.001). Conclusion: The variables that were associated with the quality of life of female riot police officers were job stress and health promotion behaviors. Therefore, interventions that can enhance job stress management and health promotion behaviors are needed to improve the quality of life of female riot police officers.

Strength analysis of mechanical transmission using equivalent torque of plow tillage of an 82 kW-class tractor

  • Kim, Taek-Jin;Kim, Wan-Soo;Kim, Yeon-Soo;Chung, Sun-Ok;Park, Seong-Un;Hong, Soon-Jung;Choi, Chang-Hyun;Kim, Yong-Joo
    • 농업과학연구
    • /
    • 제46권4호
    • /
    • pp.723-735
    • /
    • 2019
  • The power-train is the most important component of an agricultural tractor. In this study, the strength of the driving gear transmission of an 82 kW-class tractor was analyzed using equivalent torque during plow tillage. The load measurement system consisted of an engine revolution speed sensor, torque-meters, revolution speed sensors for four axles, and pressure sensors for two hydraulic pumps. The load data were measured during plow tillage for four speed stages: F2 (2.78 km/h), F5 (5.35 km/h), F7 (7.98 km/h), and F8 (9.75 km/h). Aspects of the gear-strength such as bending stress, contact stress, and safety factors were analyzed under two torque conditions: the equivalent torque at the highest plow load for the F8 speed stage and the maximum engine torque. The simulation results using KISSsoft showed that the maximum engine torque conditions had a lower safety factor than did the highest equivalent torque condition. The bending safety factors were > 1 at all gear stages, indicating that gear breakage did not occur under actual measured operating conditions, nor under the maximum torque conditions. However, the equivalent torque condition in the contact stress safety factor was > 1, and the maximum torque condition was < 1 at the first gear pair. The method of analysis using the equivalent torque showed lower stress and higher safety factor than did the method using maximum torque. Therefore, when designing a tractor by applying actual working torque, equivalent torque method would support more reliable product development.

들기 작업에서 높이와 각도 변화가 발 부위에 미치는 스트레스에 관한 연구 (An Analysis of Stress on Foot by Lifting Height and Angle)

  • 여민우;이상도;이동춘
    • 대한인간공학회지
    • /
    • 제25권3호
    • /
    • pp.17-24
    • /
    • 2006
  • In this paper, we propose a stress analysis on foot by lifting task attitudes. Maximum force and peak pressure were measured on 8 body regions by Pedar system in order to analysis the stress which is affected by task style and angle on foot when Manual Materials Handling task. As for the peak pressure of the whole foot as to the task height during the lifting task, the height from Knuckle to Shoulder was the least in the peak pressure. Also, as for the maximum force and the peak pressure of the whole foot as to the task angle during the lifting task, it could be seen that the more an angle increases, the stress influencing on a foot jumps. As for the maximum force and the peak pressure by foot region as to the task height in case of the lifting task, the height from Knuckle to Shoulder is indicated the smallest value in the maximum force and the peak pressure, thus there is necessary to attain the work design that considered this. Also, as for the maximum force by foot region as to the task angle in case of the lifting task, 0° tasking is indicated to be least, thus there is necessity to be attained the tasking design in a bid to prevent the existence of an angle. The results of this paper are thought to be helpful to the suitable work design, to the prevention of musculoskeletal disorders related to the lower limbs, and to the design of ergonomic safety shoes.

유한요소법을 이용한 임플란트 고정체의 삼각배열에 따른 지지골의 응력 분석 (Finite element stress analysis on supporting bone by tripodal placement of implant fixture)

  • 손성식;이명곤
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: This study was to propose the clear understanding for stress distribution of supporting bone by use of staggered buccal offset tripodal placement of fixtures of posterior 3 crown implant partial dentures. We realized posterior 3 crown implant fixed partial dentures through finite element modeling and analysed stress effect of implant arrangement location to supporting bone under external load using finite element method. Method: To understand stress distribution of 3 crown implant fixed partial dentures which have 2 different arrangement by finite element analysis. In each model, for loading condition, we applied $45^{\circ}$ oblique load to occlusal surface of crown and applied 100 N for 3 crown individually(total 300 N) for imitating possible oral loading condition. at this time, we calculated Von Mises stress distribution in supporting bone through finite element method. Result: When apply $45^{\circ}$ oblique load to in-line arrangement model, maximum stress result for 100 N for each 3 crown 47.566MPa. In tripodal placement, result for 1mm buccal offset tripodal placement implant model was maximum distributed load 51.418MPa, so result was higher than in-line arrangement model. Conclusion: In stress distribution result by placement of implant fixture, the most effective structure was in-line arrangement. The tripodal placement does not effective for stress distribution, gap cause more damage to supporting bone.

  • PDF