• Title/Summary/Keyword: Maximum power recovery

Search Result 92, Processing Time 0.042 seconds

Burst Mode Symbol Timing Recovery for VDL Mode-2 (VDL Mode-2에 적용 가능한 버스트 모드 심벌 타이밍 복원기)

  • Gim, Jong-Man;Choi, Seung-Duk;Eun, Chang-Soo
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.337-343
    • /
    • 2009
  • In this paper, we proposed a burst mode symbol timing recovery unit that is applicable to the VDL Mode-2 using D8PSK modulation. A method that IIR loop filter is used to minimize symbol timing error is hard to apply to burst mode because its convergence time is long. That is, the fast convergence property is important. In this paper, the proposed method takes one sample which has maximum symbol power after the initial synchronization has been achieved by using preambles. The main principle of operation is that the unit moves one sample clock to advance or retard according to symbol power. We verify that the proposed method is operated well in ${\pm}100$ ppm or greater through the test results between Australia ADS Corp. transmitter and the designed receiver.

  • PDF

A study on performance test of water heat storage type heat-pump system using cooling tower heat source (냉각탑을 이용한 축열식 히트펌프시스템의 성능측정에 관한 연구)

  • Lee, Sang-Hoon;Park, Hyo-Sik;Han, Woo-Yong;Kim, Uk-Jung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1099-1104
    • /
    • 2008
  • Recent year, mean energy consumptions of a people are higher than other country. And international oil price became over 120 dollar. This energy environment as well as energy war. Maybe, the Meteorological Administration is going to enforce scorching heatwave special report system from that come summer. Besides, 2008 summer, maximum demand power is expected by 64,240,000kW. The electric power equipment reserve rate appeared in to keep 12.5% level. Chilled water storage system witch is one of electric load administration system. Heat pump system used cooling tower heat recovery is advantage that use is possible to summer in small a public bath building. In this paper, we suggest that heat pump system by heat recovery using cooling tower when it is heating operation of ambient air temperature. To apply cooling tower heat recovery heat pump to chilled water heat storage type and achieved performance evaluation about operation. As a result, performance of heat pump system that about 121% in cooling mode, 138% in heating mode higher than KEPCO standard. And heating operation possible to ambient air temperature about $23^{\circ}C$, which of appear cooling tower outlet temperature about $13^{\circ}C$.

  • PDF

Virtual Inertial Control of a Wind Power Plant using the Maximum Rate of Change of Frequency (주파수의 최대 변화율을 이용한 풍력단지 가상관성제어)

  • Kim, Dooyeon;Kim, Jinho;Lee, Jinshik;Kim, Yeon-Hee;Chun, Yeong-Han;Kang, Yong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.918-924
    • /
    • 2013
  • In a conventional power system, the frequency is recovered to the nominal value by the inertial, primary, and secondary responses of the synchronous generators (SGs) after a large disturbance such as a generator tripping. For a power system with high wind penetration, the system inertia is significantly reduced due to the maximum power point tracking control based operation of the variable speed wind generators (WGs). This paper proposes a virtual inertial control for a wind power plant (WPP) based on the maximum rate of change of frequency to release more kinetic energy stored in the WGs. The performance of the proposed algorithm is investigated in a model system, which consists of a doubly fed induction generator-based WPP and SGs using an EMTP-RV simulator. The results indicate that the proposed algorithm can improve the frequency nadir after a generator tripping. In addition, the algorithm can lead the instant of a frequency rebound and help frequency recovery after the frequency rebound.

A Study of Trunk Muscle Fatigue and Recovery Time during Isometric Extension Tasks (허리 폄 동작시 발생하는 근육피로 회복시간 연구)

  • Kim, Jeong-Ryong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.25-33
    • /
    • 2002
  • The purpose of study is to investigate the relationship between the trunk muscle fatigue and recovery time during repetitive extension by using a surface electromyogram(EMG). Ten healthy subjects particioated in a simulated lifting task with five levels of recovery time and three levels of sub-maximal contraction. EMG signals of the L1(Lumbar 1st Vertebrae) and L3(Lumbar 3rd Vertebrae) level of the erector spinae muscle were recorded. and analyzed in terms of MPF(mean power frequency) parameter to quantify the level of muscle fatigue. It was found that MPF significantly (p<0.05) decreased during repetitive extension task at 50% and 75% sub-maximal contractions. Then it took minutes for the trunk muscle to recover from fatigue during 50% sub-maximal contraction. and it took five minutes during 75% sub-maximal contraction. and it took five minutes during 75% sub-maximal contraction. The recovery time estimated by the maximum force needs to be re-evaluated for the trunk muscle to fully recover from fatigue. In conclusion. the work/rest cycle needs to be studied based upon the information of muscle fatigue in order to prevent workers from musculoskeletal injuries during repetitive lifting task.

Dielectric Recovery Characteristics between Poles of 800kV Model Interrupter -I. Effects or separation between Moving Main Contact and Moving Arcing Contact- (800kV 모델차단부의 극간 절연회복특성 -I. 가동주접점과 가동아크접점간 이격거리의 변화에 대한 영향분석-)

  • Shin, Y.J.;Park, K.Y.;Chang, K.C.;Song, K.D.;Jeong, J.K.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.270-273
    • /
    • 1994
  • The capacitive current breaking capability as well as the short circuit current breaking capability is a very important factor in the performance of a circuit breaker. The dielectric recovery capability between poles should be considered in the desist of a circuit breaker because approximately two times of the maximum power system voltage might be applied between poles after the capacitive current be interrupted. The electric field and flow field analyses were utilized in the calculation of dielectric recovery characteristics between poles of 800kV model interrupter. The results show that the separation between moving main contact and moving arcing contact will affect to decrease significantly the electric field strength of a moving arcing contact and an insulation cover, to increase slightly the electric field strength of a fixed arcing contact and to decrease consequently the dielectric recovery capability between poles of the interrupter.

  • PDF

Exergy Analysis of Waste Energy Recovery System in Regasification Process of LNG FSRU (LNG FSRU의 재기화 공정에서 폐에너지회수시스템의 엑서지 분석)

  • Han, Seoung Hyun;Jo, Jae Ho;Kwon, Jeong-Tae;Park, Kyoungwoo;Choi, Byung Chul
    • New & Renewable Energy
    • /
    • v.18 no.2
    • /
    • pp.82-89
    • /
    • 2022
  • In this study, the exergy characteristics were analyzed, according to the mass flow rate of the propane working fluid and the pressure change in the turbine inlet, for the efficient recovery of cold energy and exhaust heat by the waste energy recovery system applied to the LNG FSRU regasification process. When the turbine inlet pressure and mass flow rate of the Primary Rankine Cycle were kept constant, the exergy efficiency and the net power increased. This occurred as the turbine inlet pressure and the mass flow rate of the working fluid increased in the Secondary Rankine Cycle, respectively, and the maximum values were confirmed. In this regard, the fluctuations in the exergy rate flowing into and out of the system and the exergy rate destroyed by pumps, evaporators, turbines, and LNG heat exchangers (condensers) were examined in detail.

Implementation of Digital Control for Critical Conduction Mode Power Factor Correction Rectifier

  • Shin, Jong-Won;Baek, Jong-Bok;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.147-148
    • /
    • 2011
  • In this paper, implementation of digital control for critical conduction mode power factor correction (PFC) rectifier is presented. Critical conduction mode is widely used in medium and low power conversion application due to its minimized MOSFET turn-on loss and diode reverse-recovery problem. However, it needs additional zero current detection circuit and maximum frequency limit to properly turn the MOSFET on and avoid the excessive switching loss in light load operation. This paper explains the digital IC implementation and verifies its operation with 200-W prototype PFC rectifier.

  • PDF

The Study about Characteristics Affecting Functional Recovery of Stroke Patients Treated in an Oriental Medical Center (한방병원에 입원한 뇌경색 환자의 기능회복과 관련된 특성에 대한 연구)

  • Kim, Young-Jee;Kim, Mi-Young;Lee, Seung-Yeop;Choi, Won-Woo;Park, Joo-Young;Kwon, Seung-Won;Jung, Woo-Sang;Moon, Sang-Kwan;Cho, Ki-Ho;Kim, Young-Suk;Park, Sung-Wook;Park, Jung-Mi;Ko, Chang-Nam;Bae, Hyung-Sup;Na, Byong-Jo
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.4
    • /
    • pp.719-731
    • /
    • 2009
  • Objectives : Stroke is the most common disabling neurological disease of adult life. The treatment and rehabilitation of stroke patients is an important and challenging area in the field of medicine. In Korea, a lot of stroke patients are treated using oriental medicine and there have been reports on their functional recovery. The aim of this study was to prove the therapeutic effect of oriental medicine on ischemic stroke. We also tried to identify characteristics of patients whose functional recovery was prominent and studied whether or not the use of fluids, anticoagulants, antiplatelets and neuroprotective agents increased the functional recovery of patients. Methods : We studied 794 patients within 2 weeks after first attack of ischemic stroke who were admitted to Kyung-Hee Oriental Medical Center from 1999 to 2000. Their maximum admission period was 60 days. Results : Motor power grade, NIHSS and MBI scores of patients improved during hospitalization significantly. Factors affecting functional recovery were admission period, motor power grade, NIHSS and MBI at admission. Age, waist-hip ratio and HDL cholesterol also affected functional recovery of patients. Whether or not fluids, anticoagulants, antiplatelets and neuroprotective agents were administered had nothing to do with functional recovery. Conclusion : Oriental medicine is effective for treatment and rehabilitation of ischemic stroke patients. When we manage stroke, we have to consider some important factors.

  • PDF

Large Eddy Simulation of Turbulent Flow in an Optimal Diffuser (큰에디모사법을 이용한 최적 디퓨져내의 난류유동 해석)

  • Lim Seokhyun;Caoi Haecheon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.811-814
    • /
    • 2002
  • Using a mathematical theory, we show that the optimality condition of a turbulent diffuser with maximum pressure recovery at the exit is zero shear stress along the wall. The optimal diffuser shape is designed through iterative procedures by using the $k-{\varepsilon}-{\nu}^{2}-f$ turbulence model for flow simulation. The Reynolds number based on the bulk mean velocity and the channel height at the diffuser entrance is 18,000. We also perform large eddy simulation to validate the shape design results and investigate the flow characteristics near the zero-skin friction wall. Results from large eddy simulation show that the skin friction is slightly higher than zero but is still very small as compared to that of the flat plate boundary layer flow Although the time-averaged wall shear stress is slightly above zero along the diffuser wall, instantaneous flow reversals occur intermittently. The streamwise mein velocity shows an asymptotic behavior of the half-power-law near the wall where the skin friction is close to zero.

  • PDF

The Effect of a Kinesio Taping on Muscle Power and Fatigue Index in Quadriceps femoris (넙다리네갈래근의 키네시오 테이핑 적용이 근파워 및 근피로에 미치는 영향)

  • Seo, Byoung-Do;Jung, Nam-Jin;Park, Sang-Wok;Oh, So-Hyeon;Woo, Ji-In;Kim, Ju-Hyun;Ahn, Seong-Min
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.17 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • Background: The purpose of this study was to investigate the effect of a Kinesio taping on muscle power and fatigue index in quadriceps femoris (vastus medialis, vastus lateralis, rectus femoris.). Methods: 15 male (heathy collegiate students) was enrolled from Kyungwoon university, Gumi. Kinesio tape was applied on quadriceps femoris muscle of subjects. Muscle power and fatigue index was measured by Wingate ergometer (warm-up was 30sec in 60W, maximum power test was 30sec in 100W, recovery was 30sec in 60W) in pre- and post applied taping. Results: As a results, there showed statistically significant improvement in mean power, peak power, mean power/kg, peak power/kg, fatigue index (p<.05). Conclusions: The study of Wingate test by applying Kinesio taping was significantly effected in mean power, peak power, mean power/kg, peak power/kg.

  • PDF