• Title/Summary/Keyword: Maximum level

Search Result 4,919, Processing Time 0.034 seconds

Propose to new Method determining level of Noise Factor of Taguchi Method (다구찌 기법의 잡음인자 수준 정하는 기법 제안)

  • Ree, Sang-Bok
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2009.10a
    • /
    • pp.317-323
    • /
    • 2009
  • In this paper, we propose new methods which is to determine level of noise factor. Even Taguchi give level of noise factor which is best(or maximum) and worst(or minimum) condition, we give level of noise factor which is representative value by observing noise factor frequency. Sometimes level of noise factor is given one, two and three. We know this method is more fit in real fields.

  • PDF

Method determining level of Noise Factor of Taguchi Method under various probability distribution (다양한 확률분포 하에서 다구찌 기법의 잡음인자 수준 정하는 기법)

  • Ree, Sang-Bok
    • Journal of Korean Society for Quality Management
    • /
    • v.37 no.4
    • /
    • pp.10-15
    • /
    • 2009
  • In this paper, we propose new methods which is to determine level of noise factor. Even Taguchi give level of noise factor which is best(or maximum) and worst(or minimum) condition, we give level of noise factor which is representative value by observing noise factor frequency. Sometimes level of noise factor is given one, two and three. We know this method is more fit in real fields.

Influence of Rock Fall on the Roofs and Rib Pillars at Multi-layered Room and Pillar Mine (다층 주방식 채광 광산에서 낙반이 천반과 광주에 미치는 영향)

  • Kim, Jong-Gwan;Yang, Hyung-Sik
    • Explosives and Blasting
    • /
    • v.34 no.4
    • /
    • pp.35-39
    • /
    • 2016
  • Influence of rock fall from upper-level roofs to lower-level roofs and pillars at a multi layered room and pillar mine was numerically simulated by using AUTODYN. The analysis results showed that the maximum displacement and stress in the roof of the lower-level stope are respectively 0.001 mm and 36 MPa, and those in the pillars of the lower-level stope are 0.0003 mm and 3 MPa. The maximum damage levels in the roof and pillar of the lower-level stope were evaluated to be about 0.03 when a half of the roof rock of the upper-level stope was assumed to be fallen to the floor.

Isolation and Characterization of the Eicosapentaenoic Acid Biosynthesis Gene Cluster from Shewanella sp. BR-2

  • Lee, Su-Jin;Seo, Pil-Soo;Kim, Chul-Ho;Kwon, Oh-Suk;Hur, Byung-Ki;Seo, Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.9
    • /
    • pp.881-887
    • /
    • 2009
  • Forty-four eicosapentaenoic acid (EPA)-producing microbial strains were isolated from the intestines of marine fishes. Among them, one strain showing a maximum level of EPA (4.78% of total fatty acids) was identified as Shewanella sp. BR-2 on the basis of its 168 rRNA sequence. The EPA content reached a maximum level during the mid-exponential phase of cell growth, and gradually decreased with further growth of the cells. A cosmid DNA including the EPA biosynthesis gene cluster consisting of pfaA-E was isolated from a cosmid library of genomic DNA of Shewanella sp. BR-2, named pCosEPA-BR2. An E. coli clone harboring pCosEPA-BR2 produced EPA at a maximum level of 7.5% of total fatty acids, confirming the EPA biosynthesis activity of the cloned gene cluster.

A study on the Behavior of Fine Particle used the HEPA Filer (HEPA Filter를 이용한 미세입자 거동에 관한 연구)

  • Kim, Won-Gang
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.3
    • /
    • pp.16-27
    • /
    • 2009
  • In this paper, I examined the level of fine dust in medical institutions, educational institutions and multi-purposed facilities to grasp the exact state of the present, and decided the level of air-borne particulate(KSM ISO Standard and ISO Standard 14644-1). We compared new proposed cleaner equipped with HEPA Filter with general cleaner and analyzed the rate of removal according to height, air volume and the equipment with the compulsive air intake. Through this comparison, I reached the conclusion as follows: 1. According to the examination, the fine dust of medical institutions, educational institutions and multi-purposed facilities in Kwang Ju is class 9. 2. The filter used in general cleaner on the market is that of HEPA-type, and its removal efficiency for fine particles($0.3{\sim}0.5{\mu}m$) is very low. 3. In the removal efficiency of new proposed cleaner equipped with HEPA Filter, the higher it is, the better, especially more than 180cm in height. 4. In case it is operated for 5 minutes under the condition of the space of $9.4m^{3}$ and the maximum air volume equipped with two induction pipes, we can keep the air cleanness level of 5 ~ 6. 5. To maintain the air cleanness for a long time, if we first operate for 5 minutes at maximum air volume and then operate at medium maximum air volume, we can keep the air cleanness with low energy.

Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source (표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가)

  • Yong-Bong Lee;Hyok-Je Kwon;Chang-Whan Kim;Man-Hee Cho;Hang Kim;SungSoo Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.143-151
    • /
    • 2023
  • In this paper, a method for evaluating the measurement uncertainty is proposed when measuring of floor impact sound insulation of buildings using standard heavy impact source. In addition to the effect of repeated measurements, several other factors such as measurement location, impact location, equipment used for sound pressure measurement, and heavy impact source, were considered. A mathematical model for the average maximum impact sound level and the uncertainty evaluation method for each factor were proposed. The present proposed method was applied to measurement results to evaluate the average maximum impact sound pressure level and the measurement uncertainty.

Studies of the Forest Structure and Productivity in Korea -Models of Maximum Productivity and Optimum Cutting Time of the Forests by Annual Ring Growth analyses- (韓國의 森林構造에 따른 物質生産力에 관한 分析 - 年齡生長 分析에 의한 森林 樹木의 最高生産力期 및 最適伐採期 推定모델 -)

  • Chang, Nam-Kee;Kim, Heui-Baek;Oh, In-Hye;Chang, Myung-Ae
    • The Korean Journal of Ecology
    • /
    • v.13 no.3
    • /
    • pp.191-202
    • /
    • 1990
  • For the maximun yield of the forest trees in the forest management, the growth of annual ring area of the major forest trees was analysed in the four areas in South Korea. The time to the maximum productivity and the optimum cutting time for the maximum yield were estimated. The growth curve of annual ring area showed sigmoid like that of other organisms. Only the growth coefficient among the areas between Fraxinus rhynchophylla and Pinus koraiensis represented significance (5% level). The growth coefficient among forest trees between Pinus densiflora and Abies holophylla, Larix kaempferi and Carpinus laxiflora, Larix kaempferi and Quercus mongolica, Larix kaempferi and Quercus serrata, Larix kaempferi and Pinus koraiensis, and Larix kaempferi and Abies holophylla represented significance (5% level). Among eight forest trees, the time to maximum productivity (tm) of Larix kaempferi was the earliest (21.4 year), and Abies holophylla was the latest (91.9 year). The optimum cutting time for the maximum yield (tc) of L. kaempferi was the earliest (29.4 year) and that of A, holophylla was the latest (122.2 year) of all communities. The optimum cutting time for the maximum yield was 1.33 times as late as the time to the maximum productivity. If the growth of annual ring area as the forest tree for wood is regarded, L. kaempferi and P. densiflora are thought to be more economical than A. holophylla and P. koraiensis.

  • PDF

Optimum Compaction Test of Roller Compacted Concrete Pavement (롤러전압 콘크리트포장의 적정 다짐실험 방안 고찰)

  • Chung, Gun Woo;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.27-33
    • /
    • 2015
  • PURPOSES : To ensure appropriate RCC properties with sufficient strength development and workability, it is necessary to secure a proper level of consistency. It is also necessary to secure maximum dry density, which is an important factor for increasing the interaction of aggregate interlocking, leading to an augmentation of RCC strength. On the other hand, the dry density of RCC can be changed owing to the compaction conditions, water content, and particle size distribution. A Proctor test and a modified Proctor test were used for determining the optimum water content needed to achieve maximum dry density with different amounts of compaction energy. A Vebe test, on the other hand, was used for checking the level of consistency, which is important for producing a workable mixture. METHODS : To confirm the degree of compaction at various particle sizes, RCC mixtures with different sand/aggregate ratios were evaluated. The Proctor test and modified Proctor test were applied to these mixtures to check the effect of the aggregate gradation and compaction energy on the maximum dry density and optimum water content. During each test, three specimens were produced for all types of water content under each aggregate gradation. A compaction curve and the optimum water content and maximum dry density for each aggregate gradation were then obtained for both tests. The range of water content for the appropriate consistency of each aggregate gradation was determined through a Vebe test. The optimum water content was then evaluated based on this range. RESULTS : The compaction test results show that the modified Proctor test provides a higher maximum dry density and lower optimum water content compared with the standard Proctor test. For the modified Proctor test, two cases of aggregate gradation (s/a = 30% and 70%) had the optimum water contents outside of the appropriate water content range. For the standard Proctor test, on the other hand, none of aggregate gradations provided the optimum water content within the desired range. CONCLUSIONS : The modified Proctor test should be used for an RCC mixture design because it can provide adequacy between maximum dry density and consistency. Moreover, the compaction roller has become highly developed for higher compaction energy.

A Study on the Estimations of Maximum Lift Coefficients of a Light Airplane (경비행기의 최대양력계수 추정에 대한 연구)

  • Lee, Jung-Hoon;Yoo, Si-Yoong
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.762-767
    • /
    • 2008
  • Estimated values for maximum lift coefficients of a light airplane, ChanGong-91, derived from an analytical method using a test database, a computational fluid dynamic method, a wind tunnel test, and a flight test are compared. The DATCOM method and VSAERO code are applied as the analytical method and the computational fluid dynamic method, respectively, in order to estimate the maximum lift coefficients of a light airplane. The wind tunnel test is conducted using a 1/14.5 scaled model installed in a closed circuit type wind tunnel. For the flight test approach, the wings-level power-off stall tests are performed to obtain the maximum lift coefficients. As a point of reference for the flight test results of the maximum lift coefficients, the differences of both estimates derived from the DATCOM method and the wind tunnel test data are smaller than those derived from VSAERO.

  • PDF

Using Net Power Control for AMOLED TV

  • Arkhipov, Alexander;Lee, Baek-Woon;Park, Kyong-Tae;Sung, Si-Duk;Shin, Sung-Tae;Chung, Kyu-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.47-50
    • /
    • 2007
  • The maximum current level in organic light emitting diodes (OLED) panel influences the maximum pixel luminance, the width of $V_{DD}$ lines, the maximum power consumption and the lifetime. We propose an algorithm that limits the overall current without any palpable image artifacts, and therefore, improve panel parameters by program.

  • PDF