• Title/Summary/Keyword: Maximum frequency

Search Result 3,931, Processing Time 0.035 seconds

Investigation of microbial contamination on manufacturing processes for small-scale Korean traditional cookies manufacturers (소규모 한과제조업체의 제조공정에 대한 미생물 오염 조사)

  • Kim Sol-A;Lee, Jeong-Eun;Park, Hyun-Jin;Park, Mi-Seon;Choi, Song Yi;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.6
    • /
    • pp.493-503
    • /
    • 2021
  • The study was designed to analyze raw and auxiliary materials of Korean traditional cookies such as Yugwa and Gangjeong, equipment and tools, personal hygiene of workers and microbial contamination of materials by each manufacturing process. In addition, it looked at washing method for reducing microorganisms at the site and reduction effect of microorganisms by frequency in the manufacturing processes of Yugwa. In the process of producing Korean traditional cookies, the level of total aerobic bacteria (TAB) in popped rice was 1.2 Log CFU/g and the level of TAB in finished products increased to 3.7 Log CFU/g. In the process of producing Yugwa, the level of TAB increased to a maximum of 6.5 Log CFU/g in the soaking process but decreased to 1.3 Log CFU/g in the frying process. However, the level of TAB increased again to 1.3 Log CFU/g in finished products that proves its recontamination. It is estimated that he manufacturing process causes cross-contamination that comes from the work tools, equipment or workers. In particular, the spatula, one of the work tools, was found to have 4.4 Log CFU/g of aerobic bacteria and 4.2 Log CFU/g of colon bacillus that show they are highly contaminated. In the soaking process of Yugwa that lasts seven days, the level of TAB was a maximum of 10 Log CFU/g and the level of total colon bacillus was 6.8 Log CFU/g. When compared with washing methods, using hands and tools or running water, it is confirmed that the level of both TAB and total colon bacillus decreased to 5.0 Log CFU/g and 2.8 Log CFU/g respectively when hands were washed with running water 10 times. The above result shows that it's required for workers to wash their hands as well as wash and disinfect work tools and equipment in the process of producing Korean traditional cookies at small-scale companies. In addition, to reduce the level of microbial contamination in finished products, workers are required to apply their reduction method at the site.

CT Evaluation of Long-Term Changes in Common Bile Duct Diameter after Cholecystectomy (담낭 절제술 후 총담관 직경의 장기 변화에 대한 CT 평가)

  • Sung Hee Ahn;Chansik An;Seung-seob Kim;Sumi Park
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.581-595
    • /
    • 2024
  • Purpose The present study aimed to investigate the frequency and extent of compensatory common bile duct (CBD) dilatation after cholecystectomy, assess the time between cholecystectomy and CBD dilatation, and identify potentially useful CT findings suggestive of obstructive CBD dilatation. Materials and Methods This retrospective study included 121 patients without biliary obstruction who underwent multiple CT scans before and after cholecystectomy at a single center between 2009 and 2011. The maximum short-axis diameters of the CBD and intrahepatic duct (IHD) were measured on each CT scan. In addition, the clinical and CT findings of 11 patients who were initially excluded from the study because of CBD stones or periampullary tumors were examined to identify distinguishing features between obstructive and non-obstructive CBD dilatation after cholecystectomy. Results The mean (standard deviation) short-axis maximum CBD diameter of 121 patients was 5.6 (± 1.9) mm in the axial plane before cholecystectomy but increased to 7.9 (± 2.6) mm after cholecystectomy (p < 0.001). Of the 106 patients with a pre-cholecystectomy axial CBD diameter of < 8 mm, 39 (36.8%) showed CBD dilatation of ≥ 8 mm after cholecystectomy. Six of the 17 patients with long-term (> 2 years) serial follow-up CT scans (35.3%) eventually showed a significant (> 1.5-fold) increase in the axial CBD diameter, all within two years after cholecystectomy. Of the 121 patients without obstruction or related symptoms, only one patient (0.1%) showed IHD dilatation > 3 mm after cholecystectomy. In contrast, all 11 patients with CBD obstruction had abdominal pain and abnormal laboratory indices, and 81.8% (9/11) had significant dilatation of the IHD and CBD. Conclusion Compensatory non-obstructive CBD dilatation commonly occurs after cholecystectomy to a similar extent as obstructive dilatation. However, the presence of relevant symptoms, significant IHD dilatation, or further CBD dilatation 2-3 years after cholecystectomy should raise suspicion of CBD obstruction.

Study of Coherent High-Power Electromagnetic Wave Generation Based on Cherenkov Radiation Using Plasma Wakefield Accelerator with Relativistic Electron Beam in Vacuum (진공 내 상대론적인 영역의 전자빔을 이용한 플라즈마 항적장 가속기 기반 체렌코프 방사를 통한 결맞는 고출력 전자파 발생 기술 연구)

  • Min, Sun-Hong;Kwon, Ohjoon;Sattorov, Matlabjon;Baek, In-Keun;Kim, Seontae;Hong, Dongpyo;Jang, Jungmin;Bhattacharya, Ranajoy;Cho, Ilsung;Kim, Byungsu;Park, Chawon;Jung, Wongyun;Park, Seunghyuk;Park, Gun-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.6
    • /
    • pp.407-410
    • /
    • 2018
  • As the operating frequency of an electromagnetic wave increases, the maximum output and wavelength of the wave decreases, so that the size of the circuit cannot be reduced. As a result, the fabrication of a circuit with high power (of the order of or greater than kW range) and terahertz wave frequency band is limited, due to the problem of circuit size, to the order of ${\mu}m$ to mm. In order to overcome these limitations, we propose a source design technique for 0.1 THz~0.3 GW level with cylindrical shape (diameter ~2.4 cm). Modeling and computational simulations were performed to optimize the design of the high-power electromagnetic sources based on Cherenkov radiation generation technology using the principle of plasma wakefield acceleration with ponderomotive force and artificial dielectrics. An effective design guideline has been proposed to facilitate the fabrication of high-power terahertz wave vacuum devices of large diameter that are less restricted in circuit size through objective verification.

Influence of Nd2O3 Addition to 0.3CaTiO3-0.7(Li1/2Nb1/2)TiO3 on their Microwave Dielectric Properties (Nd2O3 첨가가 0.3CaTiO3-0.7(Li1/2Nb1/2)TiO3 세라믹스의 마이크로파 유전특성에 미치는 영향)

  • 김범수;박일환;윤상옥;김경용
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.1
    • /
    • pp.26-32
    • /
    • 2002
  • The effects of $Nd_2O_3$ addition to $Q{\cdot}f_{0}(GHz)$ ceramics with ${\varepsilon}_r$ of 126, $Q{\cdot}f_{0}(GHz)$ of 2240 and of $68\;ppm/^{\circ}C$ on their microwave properties were investigated. For the addition of 5 wt% $Nd_2O_3$, the dielectric constant (${\varepsilon}_r$) showed maximum value of 131, then decreased with the further addition of $Nd_2O_3$. $Q{\cdot}f_{0}(GHz)$ value was still increased to 3533 with 9 wt% $Nd_2O_3$ addition, it is influenced by densification of grain boundary. With more addition of $Nd_2O_3$ up to 18 wt%, the abnormal grain growth have influence on the decreasing of $Q{\cdot}f_{0}(GHz)$ value. But with the further addition of $Nd_2O_3$ over 25 wt%, the $Q{\cdot}f_{0}(GHz)$ value was again increased by the effect of the second phase ($Nd_2Ti_2O_7$) forming. The temperature coefficient of resonant frequency (${\tau}_f$) was decreased from $+\;68\;ppm/^{\circ}C$ with the addition of $Nd_2O_3$, reached $0\;ppm/^{\circ}C$ at 12 wt% addition, and became negative with the further addition of $Nd_2O_3$. The optimum microwave dielectric properties were obtained for $0.3CaTiO_3-0.7(Li_{1/2}Nd_{1/2})TiO_3$ with 9 wt% $Nd_2O_3$ sintered at $1425^{\circ}C$ for 3 hrs. The dielectric constant (${\varepsilon}_r$), the $Q{\cdot}f_{0}(GHz)$ value, and the temperature coefficient of resonant frequency (${\tau}_f$) were 108, 3533, and $+\;6\;ppm/^{\circ}C$, respectively.

3-Dimensinal Microstrip Patch Antenna for Miniaturization (소형화를 위한 3차원 구조마이크로스트립 패치 안테나)

  • 송무하;우종명
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.2
    • /
    • pp.157-167
    • /
    • 2003
  • In this paper, to reduce the resonant length of patch, microstrip patch antenna of linear polarization which is suppressed at two radiation edges is designed and fabricated at the frequency of 1.575 GHz. The result is like that the resonant length of patch is 45 mm and the length reduction effect is 43.8 % when it is compared with that(80 mm) of plane type. The gain is 4.4 dBd and -3 dB beamwidths are 112$^{\circ}$ and 66$^{\circ}$ in the E-plane and H-plane, respectively. Also, to reduce the size of patch, microstrip patch antennas those are suppressed at four radiating comers are designed and fabricated at the same frequency in the linear and circular polarization, respectively. For linear polarization, at the 1.2 of width/length(W/L) ratio, the patch area is 53 mm $\times$ 63.6 mm and the size reduction effect is 56.1 % when compared with that(80 mm $\times$ 96 mm) of plane type. The gain is 4.3 dBd and the -3 dB beamwidths are 120$^{\circ}$ and 78$^{\circ}$ in the E-plane and H-plane, respectively. For circular polarization, the patch size(54.2 mm $\times$ 61.5 mm) is reduced by 47.2 % than that(76 mm $\times$ 83 mm) of plane type. -3 dB beamwidth of horizontal polarization in the z-x plane and vortical polarization in the y-z plane are 108$^{\circ}$ and 93$^{\circ}$, respectively and this means the increasement in both planes by 52$^{\circ}$ and 27$^{\circ}$ than those of plane type. The maximum gain is 2.5 dBd in the horizontal polarization in the z-x plane. Axial ratio is 1.5 dB at 1.575 GHz and the 2 dB axial ratio bandwidth(ARBW) is 20 MHz(1.3 %).

The Differentiation of the Cholinergic Nerve Cells at the Meynert Basal Nucleus of the Basal Forebrains in the Growth Period of Rat (흰쥐 전뇌 기저부 Meynert기저핵에서 출생 후 발육기간에 따른 콜린성 신경세포의 분화)

  • Hahm, Young-Ok;Kim, Soo-Jin
    • Applied Microscopy
    • /
    • v.31 no.4
    • /
    • pp.355-365
    • /
    • 2001
  • This study was performed to investigate the distribution and differentiation on the immunoreacted cells of the ChAT (choline acetyltransferase) at the Meynert basal nucleus of the forebrains in the growth periods of rat, using the immunohistochemistric method. According to the cell shape and the ratio of long axis vs short axis of cell soma, the ChAT antibody reacted nerve cells in the Meynert basal nucleus of the rats were classified into six types. In the adult rats, the FD (frequency distributions) of round, oval and elongated cells were maximum. The FD of these types were shown to be progressively decreased during the postnatal development. In addition, the FD of elongated nerve cells in were observed in the adult rats respectively. This was thought to be the same phenomenon as those in the round and oval cells . The total mean volume of ChAT antibody reacted cell somata was lowest in the PND (postnatal days) 7 rats and was highest in the PND 21 rats. But, those were decreased to the adult. These results suggest that ChAT antibody reacted nerve cells grow up to PND 21 and then, differentiate into the various types by neurites outgrowing. On the electron micrography, the adult rat forebrain cells were obtained to be well developed ribosomes, polysomes , rough endoplasmic reticula and mitochondria. The immunreactivities were observed in ribosomes, polysomes, rough endoplasmic reticula and outer membrane of mitochondria. Golgi complexes were poorly developed and not showed jmmunreactivity. The ribosomes , polysomes and endoplasmic reticula are considered to be closely related to the inter cellular localization and biosynthesis of the ChAT but not Golgi complex. According to the results in the present study, it is considered that the ChAT-immunoreacted nerve cells in the Meynert basal nucleus of the rat forebrains are differentiated throughout the postnatal development with following processes of changes; 1) the cholinergic nerve cells develop postnatally 2) cell soma volumes gradually increase during the early postnatal days 3) and then, cells differentiate into the various types by projecting the neurites to the appropriate area after PND 21.

  • PDF

High LO-RF Isolation W-band MIMIC Single-balanced Mixer (높은 LO-RF 격리 특성의 W-band MIMIC Single-balanced 믹서)

  • An Dan;Lee Bok-Hyung;Lim Byeong-Ok;Lee Mun-Kyo;Lee Sang-Jin;Jin Jin-Min;Go Du-Hyun;Kim Sung-Chan;Shin Dong-Hoon;Park Hyung-Moo;Park Hyim-Chang;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.6 s.336
    • /
    • pp.67-74
    • /
    • 2005
  • In this paper, high LO-RF isolation W-band MIMIC single-balanced mixer was designed and fabricated using a branch line coupler and a $\lambda$/4 transmission line. The simulation results of the designed 94 GHz balun show return loss of -27.9 dB, coupling of -4.26 dB, and thru of -3.77 dB at 94 GHz, respectively. The isolation and phase difference were 23.5 dB and $180.2^{\circ}$ at 94 GHz. The W-band MIMIC single-balanced mixer was designed using the 0.1 $\mu$m InGaAs/InAlAs/GaAs Metamorphic HEMT diode. The fabricated MHEMT was obtained the cut-off frequency(fT) of 189 GHz and the maximum oscillation frequency(fmax) of 334 GHz. The designed MIMIC single-balanced mixer was fabricated using 0.1 $\mu$m MHEMT MIMIC Process. From the measurement, the conversion loss of the single-balanced mixer was 23.1 dB at an LO power of 10 dBm. Pl dB(1 dB compression point) of input and output were 10 dBm and -13.9 dBm respectively. The LO-RF isolations of single-balanced mixer was obtained 45.5 dB at 94.19 GHz. We obtained in this study a higher LO-RF isolation compared to some other balanced mixers in millimeter-wave frequencies.

Water-Blooms (Green-Tide) Dynamics of Algae Alert System and Rainfall-Hydrological Effects in Daecheong Reservoir, Korea (대청호 조류경보제의 녹조현상 동태와 강우-수문학적 영향)

  • Shin, Jae-Ki;Kang, Bok-Gyoo;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.153-175
    • /
    • 2016
  • Daecheong Reservoir has suffered eutrophication and water-blooms by blue-green algae from initial impoundment, and algae alert system (AAS) was introduced in 1997. The purpose of this study was to investigate the effect of rainfall and hydrological factors in increase or decrease variability of green-tide and prolonged AAS, studied and analyzed the current situation of AAS has been operating for 19 years (1997~2015) in Daecheong Reservoir. The total issued number of AAS was 46 times, the most frequent period in August and September were 22 times (752 days) and 16 times (431 days), respectively, it accounted for 82.6%. Many number and frequency during this period were significantly associated with rainfall, various discharge and water level. Rainfall and hydrological events are associated with the rainy season of monsoon-Changma and the typhoon, it was concentrated in June~September, total rainfall in this period accounted for 69.9% of the annual rainfall. An increase in inflows was dependent on the intensity, frequency and the amount of rainfall. Accounted for 68.4% of the total annual inflow, it was a time when the most rapidly changing hydrological variability in the reservoir. The total outflow was closely related to rainfall, and compared the distinctive characteristics of hydropower generation and watergate-spillway discharge. In addition, the upreservoir zone of Daecheong Reservoir could be vulnerable to green-tide by regulating discharge of the upstream dam. The issue of AAS was strongly related to the with and without of watergate-spillway discharge. The watergate-spillway discharge had a total of 25 times, it was maximum 17 days from July to September in the year. And the opening times and each duration of the watergate were 1~4 times and the range of 3~37 days, respectively. When the watergate opened, the issue of AAS was maintained to 13 years and the movement of water bodies and green-tide was great about five times than that of non-open, had a profound effect on prolonged AAS within reservoir. In Daecheong Reservoir, Chusori (CHU) area of the So-ok Stream was still showing serious symptoms green-tide levels in the summer, but Janggye (JAN) waters of the main reservoir was pointed out that more important. AAS will be operated by an absolutely consider the rainfall and hydrological effects around the watergate-spillway discharge. The measures of green-tide will be included in the limnological studies more suited to the characteristics of the watershed and reservoir of the our country. Finally, from now on, we will prepare the systematic management and guidelines for vulnerable zone water-blooms that are the source within the reservoir before the monsoon rather than waiting for the arrival of green-tide on the operating stations of AAS.

A Non-Calibrated 2x Interleaved 10b 120MS/s Pipeline SAR ADC with Minimized Channel Offset Mismatch (보정기법 없이 채널 간 오프셋 부정합을 최소화한 2x Interleaved 10비트 120MS/s 파이프라인 SAR ADC)

  • Cho, Young-Sae;Shim, Hyun-Sun;Lee, Seung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.9
    • /
    • pp.63-73
    • /
    • 2015
  • This work proposes a 2-channel time-interleaved (T-I) 10b 120MS/s pipeline SAR ADC minimizing offset mismatch between channels without any calibration scheme. The proposed ADC employs a 2-channel SAR and T-I topology based on a 2-step pipeline ADC with 4b and 7b in the first and second stage for high conversion rate and low power consumption. Analog circuits such as comparator and residue amplifier are shared between channels to minimize power consumption, chip area, and offset mismatch which limits the ADC linearity in the conventional T-I architecture, without any calibration scheme. The TSPC D flip-flop with a short propagation delay and a small number of transistors is used in the SAR logic instead of the conventional static D flip-flop to achieve high-speed SAR operation as well as low power consumption and chip area. Three separate reference voltage drivers for 4b SAR, 7b SAR circuits and a single residue amplifier prevent undesirable disturbance among the reference voltages due to each different switching operation and minimize gain mismatch between channels. High-frequency clocks with a controllable duty cycle are generated on chip to eliminate the need of external complicated high-frequency clocks for SAR operation. The prototype ADC in a 45nm CMOS technology demonstrates a measured DNL and INL within 0.69LSB and 0.77LSB, with a maximum SNDR and SFDR of 50.9dB and 59.7dB at 120MS/s, respectively. The proposed ADC occupies an active die area of 0.36mm2 and consumes 8.8mW at a 1.1V supply voltage.

Investigation on Factors Influencing the Quality of Life of Arthritis Patients (관절염환자의 삶의 질에 영향을 미치는 요인탐색)

  • Oh, Hyun Ja
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.3
    • /
    • pp.431-451
    • /
    • 2000
  • In this paper, I will examine the variables influencing the Quality of Life of arthritis patients and present basic materials which help arthritis patients have positive thinking in life and ultimately lead a satisfactory life. The subjects for this study are 231 inpatients and outpatients with arthritis living in J and K city in Chonbug Province. For the analysis of collected data I employed the SAS program. The variables for characteristics and the quality of life were analysed by descriptive statistics, T-test and ANOVA, and the relations among variables were analysed through Pearson Correlation; the Regression method was employed to predict the factors affecting quality of life. For the validity of reliance on measuring equipment Cronbach Alpha was used. The results of the study are as follows : (1) The mean score of quality of life of arthritis patients is 3.09(5 in the maximum). The general characteristics which affect the quality of life are age(F=5.13, p=0.0006), standard of education(F=6.49, p=0.0003), marriage status(F=7.77, p=0.0005), monthly pay(F=4.37, p=0.0020), medical benefits (F=4.85, p=0.0087), and supports(F=4.39, p=0.0050). For the disease-related characteristics, there is a significant difference in the 6 items: pain control method(F=5.92, p= 0.0002), physical therapy(F=3.25, p=0.013), whethere or not patients exercise(F=4.62, p=0.0000), regularity of exercise(F=4.79, p=0.0000), frequency of exercise(F=6.29, p=0.0001), and amount of exercise(F=4.62, p=0.0043). Depending on the type of arthritis, there is also a significant difference in the degree of pain felt. The patients with infectious arthritis suffer from pain the most, followed by those with gout, rheumatism and degenerative arthritis, in that order. Although statistics don't show any convincing evidence, those with gout perceive that they are in best health condition, followed by those with rheumatism, degenerative arthritis, and infectious arthritis, in that order(F=2.23, p=0.0669). (2) The quality of life of arthritis patients is correlated positively with perceived health status(r=0.56, p=0.0001), health promoting behavior(r=0.53, p=0.0001), family support (r=0.46, p=0.0001), amount of exercise (r=0.36, p=0.0001), ADL(r=0.36, p=0.0001), HLOC(r=0.32, p=0.0001), frequency of exercise(r=0.32, p=0.0001)in that order, while correlated negatively with the degree of pain felt(r=-0.32, p=0.0001), the number of pain regions(r=-0.19, p= 0.0041), and the duration of pain(r=-0.14, p=0.0279). (3) Regression analysis reveals that the most powerful predictor of the quality of life is perceived health status, which account for 31.11%. The other predictors of the quality of life, which account for 60.22%, are health promoting behavior(16.51%), family support(3.81%), ADL(2.52%), gender(1.86%), the number of family members(1.36%), level of pain(1.24%), duration of pain (1.08%), and level of education(0.67%). The results of the study show that perceived health status and health promoting behavior are the two most important variables. However, considering that the perceived health condition is difficult to control by nursing intervention, it is suggested that the level of expectation for patients, must be decided first, and the health promoting behavior and the family support influencing the quality of life must be taken into account as targets for nursing intervention. As a way of controlling the quality of life, I think that a more comprehensive approach comprising the above important variables along with demographic and general characteristics is needed. I also suggest that we must continue to explore the variables affecting the quality of life and include those variables in nursing intervention.

  • PDF