• Title/Summary/Keyword: Maximum Uptake rate

Search Result 152, Processing Time 0.019 seconds

Performance Evaluation of Breast Specific Gamma Imaging (Breast Specific Gamma Imaging 장비의 성능평가)

  • Cha, Eun-Sun;Kwak, In-Suk;Noh, Ik-Sang;Yeon, Joon-Ho;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.24-27
    • /
    • 2010
  • Purpose: Early diagnosis of breast is of the utmost importance to improve prognosis. We have a limitation for mammography and sonography detecting small cancer. Clinical importance of Breast Specific Gamma Imaging (BSGI) has improved for that reason. So We studied performance evaluation test of count rate and resolution with high sensitivity to the low dose of BSGI. Materials and Methods: BSGI of Dilon 6800, point source of $^{99m}Tc$ from 1.85~148 MBq (0.05~4 mCi) at the intervals of 1.85~37 MBq (0.05~1 mCi) was used for the test. Performance evaluation method was performed for measuring deadtime for choosing at the 5 different point in the useful field of view (UFOV), acquired image for 60 seconds. Compared with reference of clinical uptake distribution of breast, activity increased according to the distance change 10, 20, 30, 40, 50 mm in the useful field of view. Results: Counting curve increased according to the activity from 1.85 MBq (0.05 mCi) to the 74 MBq (2 mCi), and it change flat shape over 74 MBq (2 mCi). The variation of the full width of half maximum (FWHM) to the distance is 4.05, 4.73, 5.77, 6.90, 8.00, 9.32 mm in 1.85 MBq (0.05 mCi), 4.30, 4.80, 5.90, 7.00, 8.10, 9.07 mm in 3.7 MBq (0.1 mCi), 4.90, 5.60, 6.20, 7.20, 8.20, 9.10 mm in 5.55 MBq (0.15 mCi), 5.30, 6.10, 6.60, 7.00, 7.90, 8.70 mm in 7.40 MBq (0.2 mCi). Conclusion: Distortions of image would be acquired because of the deadtime in BSGI. We found out the fact that specification of $^{99m}Tc$ reaction under 74 MBq (2 mCi) for BSGI. Second, FWHM distribution change from varied distance from the detector, clearly distinguished the location of the lesion.

  • PDF

The Relationship of $VO_2$Max/Min in Cardiopulmonary Exercise Test and Fat Distribution (운동부하심폐기능검사상의 분당최대산소섭취량과 체내 지방분포와의 상관관계)

  • Choi, Jae-Chol;Jee, Hyun-Suk;Park, Young-Bum;Park, Sung-Jin;Yoo, Jee-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.495-501
    • /
    • 2000
  • Background : Cardiopulmonary exercise test is a useful test for the evaluation of the cardiovascular and respiratory systems. Obese subjects have an increased resting metabolic rate ($VO_2$) compared to non~obese subjects and the increase is more marked during dynamic exercise, which results in the limitation of maximal exercise in obese subjects. In this study, the influence of the obesity and fat distribution on the maximal exercise capacity were evaluated. Methods : Maximal exercise capacity was represented by maximam maximum oxygen uptake and $VO_2$ max in the cardiopulmonary test. Obesity, total fat content and abdomina1 obesity(waist to hip ratio, WHR) were measured by bioelectrical impedence method. Total of 42 volunteers (male 22, fema1e 20) were evaluated. Results : 1) Weight to height ratio (mean$\pm$SD) was 110$\pm$14.9% in men and 100$\pm$11.1% in women. 2) Fat ratio (mean$\pm$SD) was 23.3$\pm$5.2% in men and 27.55$\pm$3.9% in woman. 3) Waist to hip ratio (mean$\pm$SD) was 0.85$\pm$0.04 in men and 0.8$\pm$0.03 in woman. 4) In men, $VO_2$ max/min/Kg was negatively correlated with obesity, fat ratio, and abdominal fat distribution. 5) In woman, $VO_2$ max/Kg was negatively correlated with obesity and fat ratio, but did not show significant relationship with abdominal fat distribution. Conclusion : Obesity was a limiting factor for maximal exercise in both men and women. Abdominal obesity was a limiting factor for maximal exercise in men but its implication to women needs further evaluation.

  • PDF