• Title/Summary/Keyword: Maximum Service Flow Rate

Search Result 24, Processing Time 0.034 seconds

Development of Adjustment Factors under Day and Night Conditions for Freeway Capacity to Improve Traffic Safety (교통안전 향상을 위한 주야 변화에 따른 고속도로 용량 보정계수 개발에 관한 연구)

  • Kim, Young Sun;Lee, Sang Soo
    • International Journal of Highway Engineering
    • /
    • v.17 no.4
    • /
    • pp.107-115
    • /
    • 2015
  • PURPOSES: This study analyzes the characteristics of traffic flow on freeway sections under daytime and nighttime conditions to improve traffic safety, and suggests a method to estimate an accurate freeway capacity value that reflects these characteristics. METHODS : The trends and differences in capacity were investigated using comprehensive field data collected under both daytime and nighttime conditions on freeway sections with designated speeds of 80, 100, and 120 kph. RESULTS : The capacity values under nighttime driving conditions were reduced by 3.3%, 6.9%, and 8.8% at 80, 100, and 120 kph, respectively. Several nighttime adjustment factors were deduced for each designated speed category from the analysis results. CONCLUSIONS : It is expected that more accurate capacity values can be estimated for freeway sections under nighttime conditions by applying the resulting adjustment factors. In addition, traffic safety will be improved through the increased efficiency of traffic management on these freeway sections.

Analysis of a relative rate switch algorithm for the ABR service in ATM networks (ATM망에서 ABR서비스를 위한 Relative Rate 스위치 알고리즘의 성능 해석)

  • 김동호;조유제
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.5
    • /
    • pp.1384-1396
    • /
    • 1998
  • This paper ivestigates the performance of a relative rate (RR) switch algorithm for the rate-based available bit rate (ABR) flow control in asynchronous transfer mode (ATM) networks. A RR switch may notify the network congestion status to the source by suing the congestion indication (CI) bit or no increase (NI)bit in the backward RM (BRM) cells. A RR switch can be differently implemented according to the congestion detectio and notification methods. In this paper, we propose three implementation schemes for the RR switch with different congestion detection and notification methods, and analyze the allowed cell rate (ACR) of a source and the queue length of a switch in steady state. In addition, we derive the upper and lower bounds for the maximum and minimum queue lengths for each scheme respectively, and evaluate the effects of the ABR parameter values on the queue length. Furthermore, we suggest the range of the rage increase factor (RIF) and rate decrease factor (RDF) parameter values which can prevent buffer overflow and underflow at a switch.

  • PDF

The Effect of Seawater Temperature on the Electrochemical Corrosion Behaviour of Stainless Steels and Anodized Aluminum Alloys (스테인리스강과 양극산화된 알루미늄 합금의 전기화학적 부식특성에 미치는 해수온도의 영향)

  • Chong, Sang-Ok;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.85-93
    • /
    • 2021
  • The corrosion damage of materials in marine environment mainly occurs by Cl- ions due to the breakdown of passive films. Additionally, various characteristics in seawater such as salinity, temperature, immersion time, flow rate, and biological activity also affect corrosion characteristics. In this study, the corrosion characteristics of stainless steels (STS 304 and STS 316L) and anodized aluminum alloys (AA 3003 and AA 6063) were evaluated with seawater temperature parameters. A potentiodynamic polarization experiment was conducted in a potential range of -0.25 V to 2.0 V at open circuit potential (OCP). Corrosion current density and corrosion potential were obtained through the Tafel extrapolation method to analyze changes in corrosion rate due to temperature. Corrosion behavior was evaluated by measuring weight loss before/after the experiment and also observing surface morphology through a scanning electronic microscope (SEM) and 3D microscopy. Weight loss, maximum damage depth and pitting damage increased as seawater temperature increased, and furthermore, the tendency of higher corrosion current density with an increase of temperature attributed to an increase in corrosion rate. There was lower pitting damage and lower corrosion current density for anodized aluminum alloys than for stainless steels as the temperature increased.

Dynamic Programming Model for Optimal Replacement Policy with Multiple Challengers (다수의 도전장비 존재시 설비의 경제적 수명과 최적 대체결정을 위한 동적 계획모형)

  • Kim, Tae-Hyun;Kim, Sheung-Kown
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.4
    • /
    • pp.466-475
    • /
    • 1999
  • A backward Dynamic Programming(DP) model for the optimal facility replacement decision problem during a finite planning horizon is presented. Multiple alternative challengers to a current defender are considered. All facilities are assumed to have finite service lives. The objective of the DP model is to maximize the profit over a finite planning horizon. As for the cost elements, purchasing cost, maintenance costs and repair costs as well as salvage value are considered. The time to failure is assumed to follow a weibull distribution and the maximum likelihood estimation of Weibull parameters is used to evaluate the expected cost of repair. To evaluate the revenue, the rate of operation during a specified period is employed. The cash flow component of each challenger can vary independently according to the time of occurrence and the item can be extended easily. The effects of inflation and the time value of money are considered. The algorithm is illustrated with a numerical example. A MATLAB implementation of the model is used to identify the optimal sequence and timing of the replacement.

  • PDF

Effects of Low-Dose Aspirin Therapy on Thermoregulation in Firefighters

  • McEntire, Serina J.;Reis, Steven E.;Suman, Oscar E.;Hostler, David
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.256-262
    • /
    • 2015
  • Background: Heart attack is the most common cause of line-of-duty death in the fire service. Daily aspirin therapy is a preventative measure used to reduce the morbidity of heart attacks but may decrease the ability to dissipate heat by reducing skin blood flow. Methods: In this double-blind, placebo-controlled, crossover study, firefighters were randomized to receive 14 days of therapy (81-mg aspirin or placebo) before performing treadmill exercise in thermal-protective clothing in a hot room [$38.8{\pm}2.1^{\circ}C$, $24.9{\pm}9.1%$ relative humidity (RH)]. Three weeks without therapy was provided before crossing to the other arm. Firefighters completed a baseline skin blood-flow assessment via laser Doppler flowmetry; skin was heated to $44^{\circ}C$ to achieve maximal cutaneous vasodilation. Skin blood flow was measured before and after exercise in a hot room, and at 0 minutes, 10 minutes, 20 minutes, and 30 minutes of recovery under temperature conditions ($25.3{\pm}1.2^{\circ}C$, $40.3{\pm}13.7%\;RH$). Platelet clotting time was assessed before drug administration, and before and after exercise. Results: Fifteen firefighters completed the study. Aspirin increased clotting time before and after exercise compared with placebo (p = 0.003). There were no differences in absolute skin blood flow between groups (p = 0.35). Following exercise, cutaneous vascular conductance (CVC) was $85{\pm}42%$ of maximum in the aspirin and $76{\pm}37%$ in the placebo groups. The percentage of maximal CVC did not differ by treatment before or after recovery. Neither maximal core body temperature nor heart rate responses to exercise differed between trials. Conclusion: There were no differences in skin blood flow during uncompensable heat stress following exercise after aspirin or placebo therapy.

A Study on the Bandwidth Allocation Control of Virtual Paths in ATM Networks for Multimedia Service (멀티미디어 서비스를 위한 ATM망에서 가상경로의 대역폭 할당 제어에 관한 연구)

  • Jang, Yung-Chul;Lee, Jung-Jei;Oh, Moo-Song
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.6
    • /
    • pp.1433-1442
    • /
    • 1997
  • Algorithm design is needed to optimized bandwidth which satisfy quality of service(QoS) requirements of vary traffic classes for Multimedia service in ATM networks. The diverse flow characteristics e.g., burstiness, bit rate and burst length, have to guarantee the different quality of service(QoS) requirements in Asynchronous Transfer Mode(ATM). The QoS parameter may be measured in terms of cell loss probability and maximum cell dely. In this paper, we consider the ATM networks which the virtual path(vip) concept is implemented by applying the Markov Modulated Deterministic Process method. We develop an efficient algorithm to computer the minimum capacity required to satisfy all the QoS requirements when multiple classes of on-off source are multiplexed on single VP. Using above the result, we propose a simple algorithm to determine the VP combination to achieve the near optimum of total capacity required for satisfying the individual QoS requirements. Numerical results are also presented to demonstrate the performance of the algorithm, when compared to the optimal total capacity required.

  • PDF

QoS-Aware Approach for Maximizing Rerouting Traffic in IP Networks

  • Cui, Wenyan;Meng, Xiangru;Yang, Huanhuan;Kang, Qiaoyan;Zhao, Zhiyuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.9
    • /
    • pp.4287-4306
    • /
    • 2016
  • Network resilience provides an effective way to overcome the problem of network failure and is crucial to Internet protocol (IP) network management. As one of the main challenges in network resilience, recovering from link failure is important to maintain the constancy of packets being transmitted. However, existing failure recovery approaches do not handle the traffic engineering problem (e.g., tuning the routing-protocol parameters to optimize the rerouting traffic flow), which may cause serious congestions. Moreover, as the lack of QoS (quality of service) restrictions may lead to invalid rerouting traffic, the QoS requirements (e.g., bandwidth and delay) should also be taken into account when recovering the failed links. In this paper, we first develop a probabilistically correlated failure model that can accurately reflect the correlation between link failures, with which we can choose reliable backup paths (BPs). Then we construct a mathematical model for the failure recovery problem, which takes maximum rerouting traffic as the optimizing objective and the QoS requirements as the constraints. Moreover, we propose a heuristic algorithm for link failure recovery, which adopts the improved k shortest path algorithm to splice the single BP and supplies more protection resources for the links with higher priority. We also prove the correctness of the proposed algorithm. Moreover, the time and space complexity are also analyzed. Simulation results under NS2 show that the proposed algorithm improves the link failure recovery rate and increases the QoS satisfaction rate significantly.

Determination and survey of tetracyclines residue in honey by high performance liquid chromatography (액체크로마토그래피를 이용한 벌꿀 중 테트라싸이클린계 항생물질의 정량분석 및 잔류조사)

  • Lee Sung-Mo;Park Eun-Jeong;Hong Jee-Young;Kim Jung-Im;Lee Jung-Goo;Hwang Hyun-Soon;Kim Yong-Hee
    • Korean Journal of Veterinary Service
    • /
    • v.28 no.3
    • /
    • pp.203-213
    • /
    • 2005
  • Oxytetracycline, tetracycline, chlortetracycline and doxycycline in honey were separated by solid phase extraction (SPE) and determined with high performance liquid chromatography (HPLC) with UV/Visible detector. Analysis was carried out using following conditions: XTerra $C_8$ column $(3.9\times150mm\;i.d. 5{\mu}m)$, mobile phase composed of 0.01M oxalic acid : methanol : acetonitrile (820 : 80 : 100, v/v/v), isocratic pump at a flow rate of 0.9 ml/min. and $50{\mu}l$ of injection volume, UV/Visible detector with wavelength of 360nm. The calibration curves of four tetracyclines showed linearity $(\gamma^2>0.999)$ at concentration range of $100\~1,000 ng/ml$. The recoveries in fortified honey represented more than $70\%$ with low coefficient of variation $(<10\%)$ for concentration range of four tetracyclines. The detection limits for oxytetracycline, tetracycline, chlortetracycline and doxycycline were 13.8, 14.6, 26.2 and 24.9ng/g in acacia honey. respectively. We also monitored tetracyclines residue in domestic honey [n : 38, acacia (20), wild flower (18) ] and foreign honey [n=22, legally distributed (13), illegally distributed (9)] using modified Charm II screening and HPLC confirmation methods. Seven of the 60 samples $(11.7\%)$ were suspect positive using modified Charm II screening test. Chlortetracycline residue was found in one foreign honey (illegally distributed) tested at concentrations of 0.22 ppm. Conclusively, for more effective control of tetracyclines used in beekeeping should be further survey for residues in honey and also national guidelines (maximum residue limit : MRL) and methods should be obligatory.

Design and Development of Network for Housing Estate Security System

  • Nachin, Awacharin;Mitatha, Somsak;Dejhan, Kobchai;Kirdpipat, Patchanon;Miyanaga, Yoshikazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1480-1484
    • /
    • 2003
  • This paper presents the design and development of network for housing estate security system. The system can cover up to 961 houses which can be up to 1,200 meters long transfer rate of 9,600 bps. This system uses checking and warning the abnormal situation. More over this system has ability to control switch on/off the electrical equipment in the house via AC line control system. The system consists of 4 parts. The first part is a security system of each house using MCS-51 microcontroller as a central processing unit scan 32 sensors and control 8 appliances and send alarm. The MCS-51 microcontroller received control signal via telephone used DTMF circuit. The second part is distributed two levels master/slave network implementing after RS-485 serial communication standard. The protocol its base on the OSI (Open Systems Interconnection) 7 layers protocol model design focus on speed, reliability and security of data that is transferred. The network security using encrypt by DES algorithm, message sequence, time stamp checking and authentication system when user to access and when connect new device to this system. Flow control in system is Poll/Select and Stop-and-Wait method. The third part is central server that using microcomputer which its main function are storing event data into database and can check history event. The final part is internet system which users can access their own homes via the Internet. This web service is based on a combination of SOAP, HTTP and TCP/IP protocols. Messages are exchanged using XML format [6]. In order to save the number of IP address, the system uses 1 IP address for the whole village in which all homes and appliance in this village are addressed using internal identification numbers. This proposed system gives the data transfer accuracy over 99.8% and maximum polling time is 1,120 ms.

  • PDF

Moxibustion for Benign Prostatic Hyperplasia: A Systematic Review and Meta-analysis (전립선 비대증에 대한 뜸치료의 효과 : 체계적 문헌고찰과 메타분석)

  • Bae, Go-eun;Lee, Seung-hwan;Hong, Jin-woo;Lee, In;Kim, So-yeon;Choi, Jun-young;Han, Chang-woo;Yun, Young-ju;Park, Seong-ha;Kwon, Jung-nam
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.3
    • /
    • pp.372-388
    • /
    • 2018
  • Objective: This study evaluates the effectiveness and safety of moxibustion for benign prostatic hyperplasia (BPH). Methods: Using the keywords "benign prostatic hyperplasia", "benign prostatic hypertrophy", "benign prostatic enlargement", "prostatic hyperplasia", and "moxibustion", we searched papers in numerous databases, including National Discovery for Science Leaders (NDSL), Korean Traditional Knowledge Portal (KTKP), Oriental Medicine Advanced Searching Integrated System (OASIS), Research Information Sharing Service (RISS), PubMed, Embase, and CENTRAL. The search range included randomized controlled trials (RCTs). Papers not matched with inclusion criteria were excluded. The methodological quality of each RCT was assessed using the Cochrane risk-of-bias tool. Where appropriate, meta-analyses were performed. Results: Initially, 77 studies were found. Of these, 11 duplicate studies were removed and 27 were excluded following title and abstract screening. After the remaining 39 papers were scanned, 13 RCTs were selected and analyzed. Among these 13 RCTs, five compared moxibustion therapy and oral medication, seven compared moxibustion plus acupuncture therapy and oral medication, and one compared moxibustion plus acupuncture therapy and sham-moxibustion. The meta-analysis showed positive results for the use of moxibustion therapy in terms of International Prostate Symptom Score (IPSS), Quality Of Life (QOL), Maximum Flow Rate (Qmax), Prostate Volume (PV), and the efficacy rate. The meta-analysis showed positive results for the use of moxibustion plus acupuncture therapy in terms of IPSS, QOL, and the efficacy rate. Conclusions: This meta-analysis of clinical trials suggests that moxibustion is effective intreating BPH patients. The results of this study could be applied to clinical treatment of BPH. However, additional large-scale clinical researches should be conducted.