• 제목/요약/키워드: Maximum Electric Field

검색결과 321건 처리시간 0.024초

DCS통신망의 노드 변화에 따른 트래픽 분석 (The Traffic Analysis of DCS Network with Different Mode number)

  • 조항신;오응세;송성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2121-2123
    • /
    • 2003
  • Distributed Control Systems(DCS) arc used in a wide range of process applications such as power plants. This paper presents calculated network capacity of a DCS that developed for nuclear power plant. The network hierarchies are 3 layed of information network, control network and field network. The assumed total node number of maximum DCS network is 64. Worst case network utilization of the DCS is simulated and analyzed.

  • PDF

Electro-Osmotic Dewatering under Electro-Osmotic Pulse Technology

  • Kim, Jitae;Lee, Jeongwoo;Chung, Il-Moon
    • 지질공학
    • /
    • 제30권4호
    • /
    • pp.423-433
    • /
    • 2020
  • Direct current (DC) electric fields have been used for electro-osmotic dewatering. Under DC conditions, however, the electrical contact resistance between the electrode and the dewatering material increases considerably during the process of dewatering. Such a circumstance hinders the continuation of effective electro-osmotic dewatering. To reduce this hindrance, an applied pulse electric field with periodic reversals of the electrode polarity should improve electro-osmotic dewatering. In this study, electro-osmotic dewatering under pulse conditions was experimentally investigated for electrode polarity reversals. During the dewatering process, the pulse electric field was able to reduce the hindrance caused by the DC, resulting in an increased final dewatered amount relative to that under a DC electric field. For a constant applied voltage, the reversed polarity condition, under which the electric current passing through the material was almost unchanged with time, yielded the maximum final dewatered amount. This technique can be used to enhance drainage from a water storage facility during a period of extreme drought and the seawater desalination plants using reverse osmosis in drought stricken coastal regions.

계자권선형 12슬롯-10극 자속 역전식 동기 전동기의 최적 설계 (Optimal Design of Field-Excitation Flux-Switching Synchronous Machine for ISG Application)

  • 구본길;정일수;남광희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.23-24
    • /
    • 2013
  • In recent years, ISG (Integrated Starter and Generator) system receives a great attention for electric electrification of normal gasoline vehicle. As a cost-effect machine design, an ISG without a permanent magnet is considered. A 12slot-10pole field-excitation flux-switching synchronous machine (FEFSSM) is designed and analyzed via JMAG. The active parts such as the field excitation coil and armature coil are located on the stator. The rotor part consisting of single piece iron makes it more robust and suitable to apply for high speed motor drive system application coupled with reduction belt. The design target is the motor with a maximum torque of 40Nm, a maximum power of 10kW and a maximum speed of 14000 rpm. In this paper, design optimization method is proposed for high torque capability.

  • PDF

1200V급 4H-SiC Trench MOSFET의 Design parameter에 따른 전기적 특성 분석 (Analysis of electrical characteristics according to the design parameter of 1200V 4H-SiC trench MOSFET)

  • 우제욱;서정주;진승후;구용서
    • 전기전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.592-597
    • /
    • 2020
  • SiC는 Si에 비해서 Breakdown field가 10배 높고, Energy gap이 3배 높기 때문에 높은 Breakdown voltage를 갖는 우수한 전력 MOSFET을 제작할 수 있다. 하지만 낮은 Mobility로 인한 높은 On저항을 갖기 때문에 이를 낮추기 위해서 Trench MOSFET이 제안되었지만 동시에 BV가 감소한다는 문제점을 갖는다. 본 논문에서는 1200V급 Trench MOSFET 설계를 목적으로 하며, 이를 해결하기 위해서 BV와 Ron에 대한 중요한 변수인 Epi 깊이, Trench 깊이, Trench 깊이에서 Epi 깊이까지의 거리에 대한 Split을 진행하여 최대 전계, BV, Ron의 신뢰성 특성을 비교 분석하였다. Epi 깊이가 증가할수록, Trench 깊이가 감소할수록, Trench 깊이에서 Epi 깊이가 감소할수록 최대 전계 감소, BV 증가, Ron 증가를 확인하였다. 모든 결과는 Sentaurus TCAD를 통해 Simulation 되었다.

배전 선로 부하예측 모델의 신뢰성 평가를 위한 비교 검증 시스템 (Development of Comparative Verification System for Reliability Evaluation of Distribution Line Load Prediction Model)

  • Lee, Haesung;Lee, Byung-Sung;Moon, Sang-Keun;Kim, Junhyuk;Lee, Hyeseon
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.115-123
    • /
    • 2021
  • Through machine learning-based load prediction, it is possible to prevent excessive power generation or unnecessary economic investment by estimating the appropriate amount of facility investment in consideration of the load that will increase in the future or providing basic data for policy establishment to distribute the maximum load. However, in order to secure the reliability of the developed load prediction model in the field, the performance comparison verification between the distribution line load prediction models must be preceded, but a comparative performance verification system between the distribution line load prediction models has not yet been established. As a result, it is not possible to accurately determine the performance excellence of the load prediction model because it is not possible to easily determine the likelihood between the load prediction models. In this paper, we developed a reliability verification system for load prediction models including a method of comparing and verifying the performance reliability between machine learning-based load prediction models that were not previously considered, verification process, and verification result visualization methods. Through the developed load prediction model reliability verification system, the objectivity of the load prediction model performance verification can be improved, and the field application utilization of an excellent load prediction model can be increased.

초고압 송전선로의 자계크기 해석과 실측 비교 (Analysis and Comparision of Measured and Calculated Value on Magnetic Fields Strength under Transmission Lines)

  • 조성배;이은웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.832-838
    • /
    • 1999
  • Recently, there are growing concerns about power frequency electric and magnetic fields coming out from the high voltage transmission lines, because of the wide spread perception of their probable harmful effect on human body. In connection with this trend, this paper describes the electric and magnetic fields measurement result around 154 kV and 345 kV transmission lines, a comparison of measured EMF to calculated one and the correlations between transmission lines currents and measured magnetic fields. Daily maximum and minimum magnetic field quantities under the selected 154 kV and 345 kV transmission lines had been measured for 1 year of 1997 and the average value of magnetic field exposure under the lines were calculated and presented based on the measured data.

  • PDF

케이블 화재의 화염전파 해석을 위한 FDS 모델의 격자민감도 평가 (Assessment of Grid Sensitivity in the FDS Field Model to Simulate the Flame Propagation of an Electric Cable Fire)

  • 김성찬;이성혁
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.30-35
    • /
    • 2008
  • The present study has been conducted to examine the effect of grid resolution on the predicted results for electric cable fire using pyrolysis model in FDS(Fire Dynamics Simulator, version 5). The grid independent test for different grid resolutions has been performed for a PE coating cable and the grid resolution is defined by the non-dimensional characteristic length of fire and mean grid size. The calculated maximum heat release rate and mean flame spread rate were almost constant for higher grid resolution of 20${\sim}$25 and the computing time for the grid resolution takes approximately 20hours to solve flame propagation with pyrolysis model. The geometrical simplification of a electric cable dose not greatly affect on the maximum heat release rate and flame spread rate and the rectangular approximation of cable shape gives acceptable result comparing with the round cable with stepwise grid.

분할형 전기히터가 장착된 디젤 매연 필터 내의 온도분포에 관한 연구 (Study on Temperature Distributions in a Diesel Particulate Filter Equipped with Partitioned Electric Heaters)

  • 박성천;이충훈;이수룡
    • 한국연소학회지
    • /
    • 제15권3호
    • /
    • pp.67-73
    • /
    • 2010
  • The temperature distribution of diesel particulate filter with five partitioned electric heaters is numerically analyzed to investigate the condition of regenerating ceramic filter. The commercial code STAR-$CCM+^{(R)}$ is utilized to simulate multi-dimensional steady hot air flow in DPF. In order to verify the computational results, thermocouples are used to measure the temperature distribution in DPF. Computational results agree well with experimental ones. The results show that the maximum temperature in DPF is lowered as the mass flow rate of exhaust gas increases, which means that the more power in heater will be necessary as the engine speed increases. Compared with heater placed at center, heater at circumference has the higher maximum temperature in DPF. The maldistribution of flow field in front of heater has the main influence on the temperature distribution in DPF.

Gate-Induced Drain Leakage를 줄인 새로운 구조의 고성능 Elevated Source Drain MOSFET에 관한 분석 (Analysis of a Novel Elevated Source Drain MOSFET with Reduced Gate-Induced Drain Leakage and High Driving Capability)

  • 김경환;최창순;김정태;최우영
    • 대한전자공학회논문지SD
    • /
    • 제38권6호
    • /
    • pp.390-397
    • /
    • 2001
  • GIDL(Gate-Induced Drain-Leakage)을 줄일 수 있는 새로운 구조의 ESD(Elevated Source Drain) MOSFET을 제안하고 분석하였다. 제안된 구조는 SDE(Source Drain Extension) 영역이 들려진 형태를 갖고 있어서 SDE 임플란트시 매우 낮은 에너지 이온주입으로 인한 저활성화(low-activation) 효과를 방지 할 수 있다. 제안된 구조는 건식 식각 및 LAT(Large-Angle-Tilted) 이온주입 방법을 사용하여 소오스/드레인 구조를 결정한다. 기존의 LDD MOSFET과의 비교 시뮬레이션 결과, 제안된 ESD MOSFET은 전류 구동능력은 가장 크면서 GIDL 및 DIBL(Drain Induced Barrier Lowering) 값은 효과적으로 감소시킬 수 있음을 확인하였다. GIDL 전류가 감소되는 원인으로는 최대 전계의 위치가 드레인 쪽으로 이동함에 따라 최대 밴드간 터널링이 일어나는 곳에서의 최대 전계값이 감소되기 때문이다.

  • PDF

SiO$_2$의 전기 광학 효과를 이용한 고전계 측정 (Measurement of High Electric Field Using Linear Electric-Optic Effect of Crystalline SiO$_2$)

  • 김요희;이대영
    • 한국통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.142-152
    • /
    • 1992
  • 본 논문에서는 광파이버 센서로써 고전계(고전압)측정의 어려움을 해결하기 위하여 지금까지 알려진 다른 전기광학 소자보다 반파장 전압이 매우 높은 SiO2를 사용하여 고전계을 계측하기 위한 새로운 방법을 제시 하였다. SiO2를 비롯한 광학소자로 구성된 센서내부, 즉 전광자 및 편광자에서의 광변조식을 Stokes Parameter와 Mueller 행렬로 유도 하였고 이를 복굴절 결정에서의 전기광학 효과를 이론적으로 해석하고 위상지연과 반파장 전압을 계산하였다. 설계 제작한 광전압 센서에 , 분압없이 최대전압 20KV까지 공급 했을때의 출력신호를 검출한 결과 오차는 3%미만으로서 매우 우수한 직선성을 얻었다. SiO2의 온도변화(-20~60$^{\circ}$C)에 따른 출력전압 변화를 실험한 결과 최대 7.5%까지 변동율이 발생하였으나 열처리 한후로는 1.0% 이내로 개선된 특성을 보였다.

  • PDF