• Title/Summary/Keyword: Maximum Connected Area

Search Result 80, Processing Time 0.026 seconds

Investigation of Laser Scattering Pattern and Defect Detection Based on Rayleigh Criterion for Crystalline Silicon Wafer Used in Solar Cell (태양전지 실리콘 웨이퍼에서의 레일리기준 기반 레이저산란 패턴 분석 및 결함 검출)

  • Yean, Jeong-Seung;Kim, Gyung-Bum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.5
    • /
    • pp.606-613
    • /
    • 2011
  • In this paper, patterns of laser scattering and detection of micro defects have been investigated based on Rayleigh criterion for silicon wafer in solar cell. Also, a new laser scattering mechanism is designed using characteristics of light scattering against silicon wafer surfaces. Its parameters are to be optimally selected to obtain effective and featured patterns of laser scattering. The optimal parametric ranges of laser scattering are determined using the mean intensity of laser scattering. Scattering patterns of micro defects are investigated at the extracted parameter region. Among a lot of pattern features, both maximum connected area and number of connected component in patterns of laser scattering are regarded as the important information for detecting micro defects. Their usefulness is verified in the experiment.

Realtime Object Region Detection Robust to Vehicle Headlight (차량의 헤드라이트에 강인한 실시간 객체 영역 검출)

  • Yeon, Sungho;Kim, Jaemin
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.2
    • /
    • pp.138-148
    • /
    • 2015
  • Object detection methods based on background learning are widely used in video surveillance. However, when a car runs with headlights on, these methods are likely to detect the car region and the area illuminated by the headlights as one connected change region. This paper describes a method of separating the car region from the area illuminated by the headlights. First, we detect change regions with a background learning method, and extract blobs, connected components in the detected change region. If a blob is larger than the maximum object size, we extract candidate object regions from the blob by clustering the intensity histogram of the frame difference between the mean of background images and an input image. Finally, we compute the similarity between the mean of background images and the input image within each candidate region and select a candidate region with weak similarity as an object region.

Carrying Capacity Estimation and Management Planning of the Seonjeong Royal Tomb(II) (선정릉의 적정수용능력추정 및 관리방안(II))

  • 이경재;오구균;조재창
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.15 no.2
    • /
    • pp.79-90
    • /
    • 1987
  • This second consecutive research was connected to 7he previous first research with same title. The purpose of this research is to estimate the carrying capacity for the Seonjeong royal tomb and to propose its management planning. User's characteristics and relationship between user's density and vegetational environment were analized for the above objective. The result of this research shall be summarized as follows. 1. The site was damaged seriously by pupils and social groups'picnic activities concentrated in special periods of Friday and weekend during April and May. 2. Social-psychological carrying capacity estimation would be impossible due to lack of relationship between user's density and satisfaction. 3. Maximum user's density limits as a ecological carrying capacity was 1.4 persons per 100 square meters and modified optimum ecological carrying capacity was estimated as 1.0persons per 100 square meters. Maximum visitors as a optimum carrying capacity of the Seonjeong royal tomb area was estimated as 6,000 persons when supposing the proposed landuse planning. 4. To restore and preserve the tomb landscape as a traditional historic site, Seonjeong royal tomb shall be managed by three landuse areas ; protection and control area, natural picnic area and shaded picnic area. And the protection and control area include three sites ; natural reclamation site, natural preservation site and tomb landscape conservation site.

  • PDF

A Study on the Characteristics of Space Programs for Senior Center in Japan (일본 노인복지센터의 공간구성 특성에 관한 연구)

  • 소준영
    • Korean Institute of Interior Design Journal
    • /
    • no.29
    • /
    • pp.153-162
    • /
    • 2001
  • This study suggests the basic data required in setting up the standard for the architectural planning of Korean senior center by analyzing the standard and current situation of a senior center in Japan that has the welfare facility system similar to that of Korea and understanding its architectural characteristics. 1) Basic spaces that constitute the senior center in Japan are meeting room, lecture room, library, multipurpose meeting room, conference room, game-recreation room, kitchen, lounge, locker room and office. ADL, kitchen, relaxing room, private bathroom, and special bathroom are needed for adult day care as establishments as an annex and work room is also required for Job training. 2) The area of a senior center is calculated in consideration of its space organization that are required as basic. For the type "A", minimum area of 1,256.42 $m^2$2 and maximum area of 2,050.56$m^2$ and for the type "B", minimum area of 812000$m^2$ and maximum area of 1,604.14$m^2$ are suggested as optimum areas. 3) The circulation planning is presented by the connected between the space organization as well as the circulation system in day care center.

  • PDF

Analysis on the Heat load Pattern According to Ratio of the Heat Consumers in District Heating (지역난방 열사용자 비율별 열부하 패턴변화 분석: 공동주택과 건물)

  • Lee, Hoon;Lee, Yoon-Pyo;Kim, Lae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.3
    • /
    • pp.123-129
    • /
    • 2010
  • The district heating users can be generally classified into two groups such as apartments and buildings. In consideration that the time zone of the maximum heat load for apartments is different from those of buildings during a day, the maximum heat supply range is presented. In case of the investigated area, the maximum heat supply is occurred at the ratio between apartments and buildings that is 65%:35%. Thus the heat supply range is increased as much as 15% if the time zone when the maximum heat load is occurred is considered.

A Study of Power Output Characteristics for the Magnesium Metal Fuel Cell (마그네슘 금속연료전지의 출력특성에 관한 연구)

  • Kim, Yong-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.212-217
    • /
    • 2014
  • The electric power output characteristics of magnesium fuel cell were investigated with regard to internal resistance. A equivalent circuit with the series-connected three internal resistance was introduced to analyze of the response to change of power. The power output analysis was employed in order to investigate the effect of internal resistances for the electrolyte concentration, air electrode area, Mg electrode area and distance between the electrodes. It was confirmed that internal resistance is generated by the electrolyte, air electrode and metal electrode, then those Internal resistances had a significant effect on the power output decrease. The power output was a maximum when the load resistance maches the internal resistance of the magnesium fuel cell. The fuel efficiency was only 50% at maximum power output. Higher fuel efficiency was achieved when the load resistance is greater than the internal resistance.

Design of a Vibration Energy Harvesting Circuit With MPPT Control (MPPT 제어 기능을 갖는 진동에너지 하베스팅 회로 설계)

  • Park, Joon-Ho;Yoon, Eun-Jung;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2457-2464
    • /
    • 2011
  • In this paper, a vibration energy harvesting circuit using a piezoelectric device is designed. MPPT(Maximum Power Point Tracking) control function is implemented using the electric power-voltage characteristic of a piezoelectric device to deliver the maximum power to load. The designed MPPT control circuit traces the maximum power point by periodically sampling the open circuit voltage of a full-wave rectifier circuit connected to the piezoelectric device output and delivers the maximum available power to load. The proposed vibration energy harvesting circuit is designed with $0.18{\mu}m$ CMOS process. Simulation results show that the maximum power efficiency of the designed circuit is 91%, and the chip area except pads is $700{\mu}m{\times}730{\mu}m$.

Microstructural Changes during Activation Process of Isotopic Carbon Fibers using CO2 Gas(II)-TEM Study (이산화탄소를 이용한 등방성 탄소섬유의 활성화과정 중 발생하는 구조변화(II)-TEM을 이용한 분석)

  • Roh, J.S.
    • Korean Journal of Materials Research
    • /
    • v.13 no.11
    • /
    • pp.749-755
    • /
    • 2003
  • A development of micropores of $CO_2$activated isotropic carbon fibers from TEM was observed. It was observed that the micropores of activated carbon fibers(ACFs) were consisted of slit-shaped pores(SP) and cylinder-shaped pores(CP). The SPs were formed between two parallel-carbon layers, and the CPs were formed at a place which is connected polygonally by more than two carbon layers. It was shown that the CPs of the ACFs were developed at high degree of burn-offs and at high activation temperature. The pore size distribution of the best ACF, which was observed at a highest value of specific surface area(3,495 $\m^2$/g), showed a continuous distribution in the range of about $4∼l5\AA$, and the median pore size was 6.7$\AA$. The super-high specific surface area of ACFs was found to be due to that the SPs were connected with a maximum size of 7∼8$\AA$ continuously, It is possible that the SPs should be formed in the ACFs in order to show super-high SSA.

Performance Analysis and Evaluation of 3kW Grid-Connected PV Systems (3kW급 계통연계형 태양광발전시스템의 성능특성 평가분석)

  • So, Jung-Hun;Jung, Young-Seok;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.8
    • /
    • pp.509-516
    • /
    • 2004
  • The concerns of distributed generations including photovoltaic(PV) system have been increased around the world since PV system is becoming widespread as a clean and gentle energy source for earth. In the future high density grid-connected PV systems will be interconnected with distribution network. As a result, the stability and long-term reliability of PV systems have become more important issues in this area. Grid-connected PV systems have been installed and monitored at field demonstration test center(FDTC) and also data acquisition system(DAS) has been constructed for measuring and analyzing performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV system has been evaluated and analyzed for component perspective (PV array and power conditioning system) and global perspective (system efficiency, capacity factor, and electrical power energy) by field test and loss factors of PV system.

The Effect of Connected Bioretention on Reduction of Surface Runoff in LID Design (LID 설계시 식생체류지간 연결에 의한 강우유출수 저감 효과분석)

  • Jeon, Ji-Hong;Seo, Seong-Cheol;Park, Chan-Gi
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.562-569
    • /
    • 2016
  • Recently, Low Impact Development (LID) is being used in Korea to control urban runoff and nonpoint source pollution. In this study, we evaluated the reduction of surface runoff from a study area, as the effect of connecting three bioretention as LID-BMP. Surface runoff and storage volume of bioretention is estimated by the Curve Number (CN) method. In this study, the storage volume of bioretention is divided by the volume of surface runoff and precipitation which directly enters the bioretention. The ratio of captured surface runoff volume to storage volume is highly influenced by the ratio of drainage area to surface area of bioretention. The high bioretention surface area-to-drainage area ratio captures more surface runoff. The ratio of 1.2 captures 51~54% of the total surface runoff, ranging from 5-30cm of bioretention depth; a ratio of 6.2 captures 81~85%. Three connected bioretentions could therefore captures much more runoff volume, ranging from $35.8{\sim}167.3m^3$, as compared to three disconnected bioretentions at their maximum amount of precipitation with non-effluent from the connecting three bioretentions. Hence, connecting LID-BMPs could improve the removal efficiencies of surface runoff volume and nonpoint source pollution.