• Title/Summary/Keyword: Maxillary Complete Dentures

Search Result 43, Processing Time 0.023 seconds

The impact of frenulum height on strains in maxillary denture bases

  • Cilingir, Altug;Bilhan, Hakan;Baysal, Gokhan;Sunbuloglu, Emin;Bozdag, Ergun
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.409-415
    • /
    • 2013
  • PURPOSE. The midline fracture of maxillary complete dentures is a frequently encountered complication. The purpose of this study was to assess the effect of frenulum height on midline strains of maxillary complete dentures. MATERIALS AND METHODS. A removable maxillary complete denture was fabricated and duplicated seven times. Four different labial frenulum heights were tested for stresses occurring on the palatal cameo surface. The strains were measured with strain gauges placed on 5 different locations and the stresses were calculated. To mimic occlusal forces bilaterally 100 N of load was applied from the premolar and molar region. RESULTS. A statistically significant association between the height of the labial frenulum and the calculated stresses and strains was shown (P<.05) predominantly on the midline and especially on the incisive papilla. The results showed that stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. CONCLUSION. Within the limitations of this in vitro study, it can be concluded that the stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. Surgical or mechanical precautions should be taken to prevent short-term failure of maxillary complete dentures due to stress concentration and low cycle fatigue tendency at the labial frenulum region.

Acoustic Characteristics of Patients with Maxillary Complete Dentures (상악 총의치 장착 환자 언어의 음향학적 특성 연구)

  • Ko, Sok-Min;Hwang, Byung-Nam
    • Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.139-156
    • /
    • 2001
  • Speech intelligibility in patients with complete dentures is an important clinical problem depending on the material used. The objective of this study was to investigate the speech of two edentulous subjects fitted with a complete maxillary prosthesis made of two different palatal materials: chrome-cobalt alloy and acrylic resin. Three patients with complete dentures in the experiment group and ten people in the controls groups participated in the experiment. CSL, Visi-Pitch were used to measure speech characteristics. The test words consisted of a simple vowel /e/, meaningless three syllabic words containing fricative, affricated and stops sounds, and sustained fricative sounds /s/ and /$\int$/. The analysis speech parameters were vowel and lateral formants, VOT, sound durations, sound pressure level and fricative frequency. Data analysis was conducted by a series of paired T-test. The findings like the following: (1) Vowel formant one of patients with complete denture is higher than that of the control group (p<0.05), while lateral formant three of patients with complete denture is lower than that of the control group (p<0.0l). (2) Patients with complete denture produced lower speech intelligibility with low fricative frequency (/$\int$/) than control group (p<0.0). The speech intelligibility of patients with metal prosthesis was higher than that of those with resin prosthesis (p<0.05). (3) Fricative, lateral and stop sound durations of patients with complete denture were longer than those of the control group (p<0.01 and p<0.05), respectively. Total sound durations of patients with metal prosthesis were similar to that of the control group (p<0.05), while those with resin prosthesis had a shorter duration (p<0.01). This implied that those with metal prosthesis had higher speech intelligibility than those with resin prosthesis. (4) Patients with complete denture had higher sound pressure levels /t/ and /c/ than the control group (p<0.01). However, sound pressure levels for /c/ of patients with metal prosthesis or resin prosthesis was similar to the control group (p<0.05). (5) Patients with complete denture had higher fundamental frequency than the control group (p<0.01).

  • PDF

Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading

  • Im, So-Min;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.22-30
    • /
    • 2017
  • PURPOSE. The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.

Functional impression technique using temporary denture for rehabilitation of severely atrophic maxillary and mandibular ridges (심한 치조제 흡수를 보이는 무치악 환자에서 임시 의치를 사용한 기능 인상에 의한 총의치 수복 증례)

  • Suh, Young-Kyo;Bae, Jung-Yoon;Kim, Hyun-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.238-244
    • /
    • 2019
  • Soft liner is used to functional impression technique when dental stone is immediately poured after taking impression because of viscoelasticity. In this case, a 78-year-old male visited for new dentures. Due to severe resorption of mandibular edentulous ridge, functional impression taking by closed mouth technique was planned. First of all, making maxillary and mandibular provisional dentures was done, and lined by soft liner to rehabilitate pressured maxillary and mandibular edentulous ridge. After this, Functional impression was taken by closed mouth technique using provisional dentures which are transformed to healed maxillary and mandibular edentulous ridge, and final denture were fabricated using maxillary provisional denture as a reference of artificial teeth arrangement. Consequently, restoring a complete edentulous patient with taking functional impression using provisional dentures resulted in recovering satisfying retention and function.

Prosthodontic management of worn dentition in pediatric patient with complete overlay dentures: a case report

  • Kumar, Prince;Rastogi, Jyoti;Jain, Chandni;Singh, Harkanwal Preet
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.239-242
    • /
    • 2012
  • Overlay complete dentures are simple, reversible and economical treatment modality for patients with congenital or acquired disorders that severely affect the tooth development. It satisfies both the esthetic and functional demands where the extraction of teeth is not generally indicated. In pediatric patients, the overlay dentures establish a relatively stable occlusion that improves patient's tolerance to the future treatment procedures for worn dentition. This clinical report highlights the imperative need of appropriate treatment strategy and application of maxillary and mandibular overlay dentures in a pediatric patient who suffered from congenitally mutilated and worn dentition.

DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING (의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구)

  • Choi Hoon-Dal;Kwon Kung-Rock;Kim Hyeong-Seob;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.

Prevention of Candida albicans infection in dental polishing lathe by chlorhexidine (클로르헥시딘을 이용한 치과기공용 연마기 캔디다균의 감염방지)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.274-279
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the transmission of candida in denture by dental polishing lathe. Materials and Methods: Maxillary complete dentures made from the same model were infected with Candida albicans. Polishing wheels were keep in various chlorhexidine solution and distilled water for an hour. The infected dentures were polished by prepared dental polishing lathe with sterile pumice and distilled water. And then sterile maxillary complete dentures were polished with same method. Polishing surface was wiped with a cotton swab and the sample was regrown for checking Candida albicans. Results: All polishing wheel with chlorhexidine resist fungal infection. But the polishing wheel with distilled water is infected with Candida albicans. Conclusion: A chlorhexidine is highly efficient in fungal infection prevention on dental polishing lathe.

Neutral zone approach for rehabilitation of severely atrophic maxillary and mandibular ridges: A case report (치조제 흡수가 심한 환자에서 중립대를 이용한 총의치 수복 증례)

  • Lee, Ja-Youn;Choi, Sun-Young;Lee, Ji-Hyoun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.407-412
    • /
    • 2016
  • The neutral zone technique is an alternative approach for the construction of complete dentures on highly atrophic ridges with history of denture instability. This technique achieves two objectives. First, the teeth will not interfere with the normal muscle function, and second, the force exerted by the musculature against the denture is more favorable for stability and retention. In this case of a 78-years-old female patient with severely atrophic ridges who had been using unstable complete dentures, the neutral zone impression technique was used to increase the stability and the retention of dentures. The neutral zone for both arch was located with modeling compound. After the arrangement of artificial teeth within the neutral zone, the external impression was taken to determine the tissue surface. The final dentures showed enhanced stability and retention and the patient was satisfied with the new dentures with respect to functional and esthetic aspects.

Frenectomy for improvement of a problematic conventional maxillary complete denture in an elderly patient: a case report

  • Al Jabbari, Youssef S.
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.236-239
    • /
    • 2011
  • Maxillary labial and buccal frena are considered as normal anatomic structures in the oral cavity. However, they may exist intraorally as a thick broad fibrous attachment and/or become located near the crest of the residual ridge, thus interfering with proper denture border extension resulting in inferior denture stability, retention and overall patient satisfaction. This case report highlights the importance of clinical examination and treatment planning which may mandate preprosthetic surgery prior to fabrication of a new conventional complete denture. Adequate patient satisfaction with conventional complete dentures can be significantly increased after frenectomy.

Study of transmission of Candida albicans in denture by dental polishing lathe (의치에서 치과기공용 연마기를 통한 캔디다균의 전염성에 대한 연구)

  • Lee, Gi-Ho;Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.199-205
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate the transmission of candida in denture by dental polishing lathe. Materials and Methods: Maxillary complete dentures made from the same model were infected with Candida albicans. The infected dentures were polished by dental polishing lathe with sterile pumice and distilled water. And then sterile maxillary complete dentures were polished with same method. Polishing surface was wiped with a cotton swab and the sample was checked for Candida albicans. The polishing wheel at room temperature was checked for Candida albicans every 24 hours for 3 days. Results: A considerable number of Candida was found on the polished sterile dentures. And the Candida albicans in polishing wheel was detected at up to two days. Conclusion: An anti-infection measure is urgently needed when dental polishing lathe is used for denture polishing, because of the possibility of fungal infection.