• 제목/요약/키워드: Maxilla and mandible

검색결과 747건 처리시간 0.026초

위치부정맹출(位置不正萌出)에 관(關)한 상하악골(上下顎骨)의 비교관찰(比較觀察) 증례(症例) (DIFFERENCE IN THE PATTERN OF ECTOPIC ERUPTION BETWEEN MAXILLA AND MANDIBLE : REPORT OF CASE)

  • 손동수
    • 대한소아치과학회지
    • /
    • 제8권1호
    • /
    • pp.21-24
    • /
    • 1981
  • The author observed a case of ectopic erupted maxillary second premolars and impacted mandibular second premolars due to premature loss of the primary second molars. The treatments were done as follows: 1. In the maxilla, the teeth arrangement problem was corrected with removal of the ectopic erupted second premolars. 2. In the mandible, normal dentition was established with surgical removal of the left second premolar and removal of the permanent first molar in right side combined by orthodontic therapy.

  • PDF

한국인 7-17세 아동의 두개저, 상악, 하악의 성장에 관한 준종단적 연구 (A Semilongitudinal Study on Cranial Base, Maxillary and Mandibular Growth of Korean Children Aging 7 to 17 Years Old)

  • 손병화;김형순
    • 대한치과교정학회지
    • /
    • 제29권1호
    • /
    • pp.23-35
    • /
    • 1999
  • 한국인 7세-17세 아동의 두개저, 상악, 하악의 사춘기 성장 양상을 파악해 보고자 남자 251개, 여자 286개의 측모두부계측방사선 사진을 이용, 10개의 계측점과 16개의 계측항목을 설정하고 계측항목에 대한 계측치와 각 연령별 년간 누년차를 산출한 다음 이들간의 통계적 유의성을 검증하였으며 각 계측항목을 두개저, 상악, 하악의 세군으로 분류하고 또 남녀별로 분류하여 비교함으로써 다음과 같은 결론을 얻었다. 1. 한국인 성장기 아동에 있어서의 성장은 남자 아동에 비해 여자 아동이 빠른 시기에 일어났다. 2. 두개저, 상악골, 하악골 모두 사춘기 성장을 나타내었으나 두개저의 성장은 안면골 성장에 비해 상대적으로 작았다. 3. 두개저 성장에 있어서 전두개저 길이의 증가에 비해 중두개저 및 후두개저의 길이 증가가 현저했으며 사춘기 성장증가(circumpuberal growth spurt) 양상도 보다 명확했다.4. 상악골의 전하방 이동은 상악골 자체의 길이 성장과 상악골 주위 봉합부의 성장에 따른 변위가 종합된 결과로 두개저에 대한 상악골의 상대적 위치를 나타내는 Ar-ANS와 Ar-Pr이 상악골 자체의 길이 성장을 나타내는 ANS-PNS보다 많은 성장량을 보였다. 5. 하악골은 수평 성장량에 비해 수직 성장이 약간 크게 나타났으나 유의할 수준은 아니다. 6. 상악 치조골과 하악 치조골은 유치 탈락후 영구치 맹출시기에 최대 성장률을 보인후 감소하는 경향을 보이지만 하악 치조골의 수직성장에서는 사춘기 성장증가가 관찰되었다.

  • PDF

Comparative Study of the Early Loading of Resorbable Blasting Media and Sandblasting with Large-grit and Acid-etching Surface Implants: A Retrospective Cohort Study

  • Kim, Sung-Beom;Kim, Young-Kyun;Kim, Su-Gwan;Oh, Ji-Su;Kim, Byung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권6호
    • /
    • pp.247-252
    • /
    • 2014
  • Purpose: This study compares the prognosis (the survival rate and marginal bone loss) of resorbable blasting media (RBM) surface implants and sandblasting with large-grit and acid-etching (SLA) surface implants in the early loading. Methods: This study targeted 123 patients treated by implants installation from January 2008 to March 2010. The loading was initiated in the maxilla within three to four months and in the mandible within one to two months. The types of restoration were single crown and fixed partial prosthesis. Those functioned over one year. The implants were classified by the surface of implants as Group 1: RBM surface (GS III; OSSTEM, Busan, Korea) and, Group 2: SLA surface (Superline; Dentium, Seoul, Korea). The groups were categorized by maxilla and mandible and compared by survival rate, marginal bone loss through clinical records evaluation, and radiographic measurements. Results: The marginal bone loss in the maxilla was $0.14{\pm}0.34mm$ (Group 1) and $0.30{\pm}0.37mm$ (Group 2), a statistically significant difference (P<0.05). In the mandible those were $0.28{\pm}0.54mm$ (Group 1) and $0.20{\pm}0.33mm$ (Group 2), not significant (P>0.05). There was no significant difference of marginal bone loss between maxilla and mandible by groups. During observation there was no implant failure, a survival rate of 100%. Conclusion: Both surfaces showed an excellent survival rate, and the marginal bone loss was not substantial.

An unusual presentation of non-specific cystic degeneration of craniofacial fibrous dysplasia: a case report and review of literature

  • Hong, Inseok;Kang, Dong Cheol;Leem, Dae-Ho;Baek, Jin-A;Ko, Seung-O
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.31.1-31.7
    • /
    • 2020
  • Background: Fibrous dysplasia (FD) is a rare, sporadic, and benign congenital condition in which normal cancellous bone is replaced by fibro-osseous tissue with immature osteogenesis. FD localized in the cranial and facial bones is called craniofacial fibrous dysplasia (CFD). Cystic degeneration in CFD cases is rare; cystic degeneration appearing in both the maxilla and the mandible FD lesion is even rarer. The aim of this article was to report a case of fibrous dysplasia of the mandible and maxilla complicated by nonspecific cystic degeneration. Case presentation: A 30-year-old woman presented with a rare case of non-specific cystic degeneration in a mandible and maxilla FD lesion that occurred 11 years after surgery. She was diagnosed with polyostotic CFD and underwent maxillary and mandibular bone contouring. Cyst enucleation under general anesthesia was performed in the mandibular region due to pain and discomfort. Conclusions: In cases involving non-aggressive and non-invasive FD cystic degeneration in focal areas, conservative treatment is recommended. However, if cystic degeneration of FD develops rapidly and causes discomfort, pain, or dysfunction, surgical treatment should be considered.

Determination of Scattered Radiation to the Thyroid Gland in Dental Cone Beam Computed Tomography

  • Wilson Hrangkhawl;Winniecia Dkhar;T.S. Madhavan;S. Sharath;R. Vineetha;Yogesh Chhaparwal
    • Journal of Radiation Protection and Research
    • /
    • 제48권1호
    • /
    • pp.15-19
    • /
    • 2023
  • Background: Cone beam computed tomography (CBCT) is a specialized medical equipment and plays a significant role in the diagnosis of oral and maxillofacial diseases and abnormalities; however, it is attributed to risk of exposure of ionizing radiation. The aim of the study was to estimate and determine the amount of scattered radiation dose to the thyroid gland in dental CBCT during maxilla and mandible scan. Materials and Methods: The average scattered radiation dose for i-CAT 17-19 Platinum CBCT (Imaging Sciences International) was measured using a Multi-O-Meter (Unfors Instruments), placed at the patient's neck on the skin surface of the thyroid cartilage, with an exposure parameter of 120 kVp and 37.07 mAs. The surface entrance dose was noted using the Multi-O-Meter, which was placed at the time of the scan at the level of the thyroid gland on the anterior surface of the neck. Results and Discussion: The surface entrance dose to the thyroid from both jaws scans was 191.491±78.486 µGy for 0.25 mm voxel and 26.9 seconds, and 153.670±74.041 µGy from the mandible scan, whereas from the maxilla scan the surface entrance dose was 5.259±10.691 µGy. Conclusion: The surface entrance doses to the thyroid gland from imaging of both the jaws, and also from imaging of the maxilla and mandible alone were within the threshold limit. The surface entrance dose and effective dose in CBCT were dependent on the exposure parameters (kVp and mAs), scan length, and field of view. To further reduce the radiation dose, care should be taken in selecting an appropriate protocol as well as the provision of providing shielding to the thyroid gland.

턱교정 수술에 있어 흡수성 고정판 및 나사 사용에 대한 임상적 연구 (CLINICAL STUDY ON USE OF BIODEGRADABLE PLATE AND SCREW IN ORTHOGNATHIC SURGERY)

  • 박성수;최진영
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.127-135
    • /
    • 2009
  • Objectives : The titanium fixation system has been used in orthognathic surgery for fixation of bone segments usually, but the biodegradable fixation system was developed and also being used. The strongest point in the biodegradable system is that no extra operation should be needed to remove fixation materials. In spite of this merit, oral & maxillofacial surgeons hesitate to use this system in fracture or orthognathic surgery. In this study, as we got some clinical experiences, we'd like to report the result of clinical study using the biodegradable fixation system in orthognathic surgery. Patients and Methods : A total of 35 patients composed of 17 males and 18 females with 25 osteotomies in maxilla and 34 osteotomies in mandible were fixated with the biodegradable fixation system(Inion $CPS^{(R)}$). We investigated methods of stabilization, fixation time, and complications on the basis of the method as above. Results : Four 2mm thick L shaped plates with 7 holes of which 1 hole was removed were fixed in maxilla with six $2.0{\times}7mm$ screws. Three $2.5{\times}16{\sim}18mm$ screws were used to fix superior ramus area and one mandibular angle area in mandible. It took about 27.4 minutes in maxilla, 25.3 minutes in mandible to perform the fixation which took longer time than the titanium system(9.5 minutes in maxilla, 8 minutes in mandible). Generally, there was no problem except 9 cases in which there were some complications. Conclusions : In most cases, the biodegradable fixation system can be used without problem in usual orthognathic surgery. But, this system is inferior to the titanium fixation one in some respects such as fixation time, size, and physical property. Some supplementations for such weak points as aforementioned should be needed for the universal use of biodegradable materials.

Treatment concepts for the posterior maxilla and mandible: short implants versus long implants in augmented bone

  • Thoma, Daniel Stefan;Cha, Jae-Kook;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • 제47권1호
    • /
    • pp.2-12
    • /
    • 2017
  • The aim of this narrative review is to describe treatment options for the posterior regions of the mandible and the maxilla, comparing short implants vs. longer implants in an augmented bone. The dental literature was screened for treatment options enabling the placement of dental implants in posterior sites with a reduced vertical bone height in the maxilla and the mandible. Short dental implants have been increasingly used recently, providing a number of advantages including reduced patient morbidity, shorter treatment time, and lower costs. In the posterior maxilla, sinus elevation procedures were for long considered to be the gold standard using various bone substitute materials and rendering high implant survival rates. More recently, implants were even placed without any further use of bone substitute materials, but the long-term outcomes have yet to be documented. Vertical bone augmentation procedures in the mandible require a relatively high level of surgical skill and allow the placement of standard-length dental implants by the use of autogenous bone blocks. Both treatment options, short dental implants, and standard-length implants in combination with vertical bone augmentation procedures, appear to result in predictable outcomes in terms of implant survival rates. According to recent clinical studies comparing the therapeutic options of short implants vs. long implants in augmented bone, the use of short dental implants leads to a number of advantages for the patients and the clinician.

춘천지역의 안면골 골절에 관한 임상적 연구 (A CLINICAL AND STATISTICAL STUDY FACIAL BONE FRACTURE)

  • 이정구;한명수;김상봉;김학범
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제12권1호
    • /
    • pp.103-113
    • /
    • 1990
  • The study was based on a series of 252 patient with facial bone fractures who visited to Chun Cheon Sacred Heart Hospital, College of Medicine, Hallym University during the period of Dec., 1984 trough Nov., 1989. The results obtained are as follows; 1. The most frequent etiologic factor was traffic accident(45.2%). 2. The ratio of male to female was 5.5 : 1 and 2nd decade(44%) was the highest age group in incidence. 3. Monthly incidence was the highest in Aug(14.3%). 4. The most common site of fracture was mandible(55.3%) and zygoma complex(24.2%), nasal bone(11.6%), maxilla(8.9%) were next in order of frequeny. 5. In mandible fractures, the most frequent site was symphyseal area(36.9%) and 142 cases(85%) had fractures only in mandible. 6. In maxillary fractures, fracture with other facial bones(85.2%) was more frequent than fracture on maxilla only. The major fracture type on maxilla was Le Fort II type. 7. In fracture of zygoma complex, zygoma & zygomatic arch was the most frequent site(52.0%) and zygomatic arch(24.7%), zygoma(23.3%) were next in order. 8. Open reduction was major method of treatment in facial bone fractures except nasal bone ; mandible(62.9%), maxilla(77.8%), zygoma complex(65.8%). 9. Maxillofacial fractures were most frequently combined with head & neck injury(43.1%), and upp. & low. extremities(29.4%), chest and abdomen(11.9%) were in order of frequency.

  • PDF

상하악 미니플레이트 골 내 고정원 Face Corrector를 이용한 제3급 환자의 상악골 전방견인과 Face Mask를 이용한 상악골 전방견인의 비교 (Maxillary Protraction with Maxillary and Mandibular Miniplates (face corrector): In Comparison to Face Mask Protraction in Class III Patients)

  • 이지나
    • 대한구순구개열학회지
    • /
    • 제16권1호
    • /
    • pp.19-23
    • /
    • 2013
  • Maxilla protraction, orthopedic correction of deficient maxilla is necessary for treatment of most Class III growing patients. Protraction method has evolved from tooth-born appliance to miniplates on the maxilla, and from face mask to miniplates on the chin. By placing miniplates on the maxilla and the mandible and running elastics between them, we can minimize dentoalveolar relapse and maximize orthopedic change.

  • PDF

컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구 (BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY)

  • 손장호;최병환;박수원;조영철;성일용;이지호;변기정
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.