• 제목/요약/키워드: Mattress system

검색결과 41건 처리시간 0.027초

정체수역에서의 Mattress/Filter에 의한 수생식물 복원 (Aquatic Plant Restoration by Mattress/Filter System in Stagnant Stream Channel)

  • 여운기;허창환;이승윤;지홍기
    • 한국환경과학회지
    • /
    • 제15권1호
    • /
    • pp.21-31
    • /
    • 2006
  • Aquatic plants grow in water with photosynthesis and purify water quality as taking organic and inorganic matter in water. Polluted water in stagnant stream channel where nutritive salts load is great can be purified by activities of aquatic plants. Aquatic plants should be fixed to bed easily to plant and sustainable environment is needed. So in this study, Mattress/Filter system is suggested to plant aquatic plant in stagnant stream channel. In the result of study, coverage of Phragmites australis, Zizania latifolia and Typha angustifolia which planted in mattress was $78\%,\;62\%\;and\;82\%$ and numbers of species in each mattress system were 7, 11, 3. The evenness index of each mattress system was 0.86, 0.91 and 0.79 and diversity index of each mattress system was 1.67. 2.18 and 0.87. Removal rates of phosphorus at Phragmites australis, Zizania latifolia and Typha angustifolia which planted in mattress were $68.7\%,\;62.7\%,\;55.3\%$ and removal rates of nitrogen of them were $79.8\%,\;74.7\%,\;64.9\%$. The removal rate of nitrogen was greater than phosphorus at all system and both removal rates were greater at Phragmites australis than at Zirania latifolia and at Typha angustifolia the rate was the least. Removal rates of $PO_4^{-3},\;NH_4-N,\;NO_{3-}N$ at Phragmites australis were $57.4\%,\;52.8\%,\;47.8\%$ and at Zizania latifolia were $82.6\%,\;77.2\%,\;67.5\%$ and at Typha angustifolia were $80.6\%,\;73.7\%,\;64.3\%$. It seems that removal effect is great by the planted mattress system.

지오그리드 매트리스기초에 관한 실험적 연구 (Experimental Study on Geogrid-Mattress Fundation)

  • 주재우
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.182-190
    • /
    • 1994
  • Mattress foundations using geogrids are often used on soil foundations to increase the supporting capability of a mattress-soil foundation system, in which the mattress foundation trasmits a point load applied above to a wider area of the soil foundation underneath. To examine this load dispersion capability of the mattress foundation, model experiments were carried out on lab-floor. Expecially, the effect of the thickness of the mattress and the subgrade modulus of the soil foundation on load dispersion are considered. The load distribution and the tensile force generated on geogrid of the upper part of the mattress are examined in the paper.

  • PDF

호안 Mattress/Filter에 의한 소류력 저감 (Reduction of Tractive Force by Revetment Mattress/Filter)

  • 서영민;이승윤;허창환;지홍기
    • 한국환경과학회지
    • /
    • 제15권1호
    • /
    • pp.33-43
    • /
    • 2006
  • Revetment Mattress/Filter is the porous structure filled fillers in meshed structure so that it cail use the fillers of various sizes and form various pores. The porous structure of the Mattress/Filter increases drainage so that it decreases the energy and erosion of flow therefore the tractive force is decreased and the erosion of revetment is mitigated. The filler of Mattress/Filter uses gravels, waste concretes and slags so that the surface is rough and the roughness coefficient increases and the increase of the roughness coefficient decreases flow velocity and tractive force. On the other hand Mattress/Filter and vegetation are combined so that the increase of roughness coefficient and flow velocity still more progress therefore the effect of decrease of tractive force is increased after a few months have passed since the Mattress/Filter is constructed so that the vegetation is developed and be stabilized. The vegetation channel of Mattress/Filter is set tip and the inspection comes into operation by varing flowrate and vegetation spacing to examine these characters of the Mattress/Filter The coefficient of flow velocity U/U*' is decreased exponentially as vegetation esity aH' or $\lambda$ is increased and the coefficient of friction f is increased as vegetation desity aH' is increased but decreased as the coefficient of flow velocity U/U*' is increased. The effective tractive force $F_0$ is decreased exponentially as the vegetation desity aH' is increased. From the inspection the results are obtained that the porous and vegetation structure of the revetment Mattress/Filter system increases the coefficient of friction of revetment so that flow velocity and effective are decreased therefore greatly contributes the stability of the revetment.

Mattress/Filter 채움재의 공극률에 따른 하천수질 개선효과 (Effects of Water Quality Improvement by Porosity of Fill Materials in Mattress/Filter System)

  • 고진석;이승윤;허창환;지홍기
    • 대한토목학회논문집
    • /
    • 제26권1B호
    • /
    • pp.51-60
    • /
    • 2006
  • 산업활동으로 인해서 발생하는 제강슬래그와 최근 선진국에서 환경개선 및 오염방지를 위한 용도로 활용하고자 활발히 연구되고 있는 제올라이트 등의 다공성 재료를 오염된 하천의 정체수역에 설치하여 저비용으로 수질을 개선시킬 수 있는 기법은 폐기물의 재이용 측면과 하천수질개선 측면에서 매우 필요하다. 현재 제철소에서 발생하는 부산물인 제강슬래그의 화학적성분은 주로 CaO, $SiO_2$, $Al_2O_3$, $Fe_2O_3$ 등으로 이루어져 있으며, 침전유발물질 및 흡착성물질이 함유되어 있다. 제강슬래그는 다공질 형태의 비표면적을 가지고 있어서 정화용 필터나 흡착재로 이용하기에 좋은 이점을 지니고 있다. 그리고 제올라이트는 양이온 교환특성, 흡착특성, 촉매특성, 탈수 및 재흡수특성 등의 이점을 지니고 있어서 축산농가의 환경개선, 도시의 생활하수의 처리, 공업폐수 처리, 음료수 수질개선, 방사성폐기물 처리 및 방사성 물질의 오염방지 등에 응용되고 있다. 그러므로 제강슬래그나 제올라이트를 Mattress/Filter의 채움재 및 수질정화용 여재로 활용함으로써 수질개선 등 효과를 동시에 얻을 수 있다. 본 연구에서는 제강슬래그와 제올라이트가 정체수역에 설치되는 Mattress/Filter시스템의 채움재로 활용할 때 공극률에 따른 수질개선효과를 파악하기 위하여 공극률을 38.6%인 P1, 45.8%인 P2 및 49.8%인 P3로 변화시켜 각각의 유입수와 유출수의 pH, DO, T-N, T-P 등을 측정하여 비교하였다. 수질개선에 사용된 Mattress/Filter시스템은 오염된 하천수가 Mattress/Filter시스템의 공극사이를 통과하면서 채움재에 형성된 다공질에 의한 여과작용과 생물막에 의한 접촉작용, 흡착작용 및 생물분해작용 등을 촉진시키는 기능을 가지고 있음을 알 수 있었다. 제강슬래그 및 제올라이트를 채움재로 사용한 Mattress/Filter 시스템은 쉽게 생물막을 형성시키고 유기물의 흡착을 촉진시켜 오염물질을 정화하는데 필요한 자정작용의 효과를 증대시키고 수질개선을 촉진시킬 수 있는 자연환경에서 하천정화에 이용될 수 있는 시스템임을 확인할 수 있었다.

침대 매트리스 실규모 화재안전 평가시스템 기술 (Description on assessment system of bed mattress's fire safety in real scale)

  • 박계원;정재군
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.329-332
    • /
    • 2012
  • This study focuses on the establishment of bed mattress fire test in real scale where it explains the burner heat supply, test procedure and test report in detail. Especially burner system is dealt in importance for bed mattress test in real scale due to simulating in bedding component by burner heat out-put.

  • PDF

A Novel Air-cell Mattress Based on Approximate Anthropometric Model for Preventing Pressure Ulcer

  • Moon, In-Hyuk;Kang, Sung-Jae;Kim, Gyu-Seok;Mun, Mu-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1278-1282
    • /
    • 2005
  • Air mattress is now used widely to prevent the pressure ulcer by reducing the localized pressure peaks. In this paper an air-cell mattress and its pressure control method based on an approximate anthropometric model are presented. The air-cell mattress has eighteen cylindrical air cells made of porous material allowing air leakage to contribute in reducing the development of pressure ulcer by lowering the pressure peak, temperature and humidity. To determine an optimal air-cell pressure appropriate for each user, we divide the parts of the body into four sections such as head, trunk, hip, and leg. Then, the pressure of each section is independently calculated from the weight of each part based on the individual body height and weight and the approximate anthropometric model. Air supply system for the air-cell mattress is implemented by using four electronic solenoid valves and an air compressor, and it is driven by a real-time micro-controller. The experimental results with seven subjects shows that the proposed air-cell mattress is effective for the prevention of the pressure ulcer.

  • PDF

전기다리미의 발화원인 판정에 관한 현상학적 고찰 (A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron)

  • 문용수;공하성;이종화
    • 대한안전경영과학회지
    • /
    • 제11권1호
    • /
    • pp.43-49
    • /
    • 2009
  • This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

에어 매트리스와 산소 포화도 측정기를 이용한 수면호흡장애 자동 검출 시스템 개발 (Development of Sleep-disordered Breathing Detection System using Air-mattress and Pulse Oximeter)

  • 정필수;박종욱;주은연;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권4호
    • /
    • pp.153-162
    • /
    • 2017
  • The present study proposes a system that can detect sleep-disordered breathing automatically using an air mattress and oxygen saturation. A thin air mattress was fabricated to reduce discomfort during sleep, and respiration signals were acquired. The system was configured to be synchronized with a polysomnography to receive signals simultaneously with other bio-signals. The present study has been conducted with nine adult male and female patients with sleep-disordered breathing, and sleep-disordered breathing events have been detected by applying the signals acquired from the subjects to the rule-based detection algorithm. The sensitivity and positive predictive values were found to evaluate the performance of the system, which are 91.4% and 89.7% for all events, respectively. The comparison of apnea hypopnea index(AHI) between the polysomnography and the proposed method showed squared R-value of 0.9. This study presents the possibility of detecting sleep-disordered breathing at hospitals or homes using the proposed system.

공기 매트리스와 디지털 신호처리를 이용한 홈헬스케어용 무구속 수면 모니터링 시스템 (The Unconstrained Sleep Monitoring System for Home Healthcare using Air Mattress and Digital Signal Processing)

  • 지영준;박광석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.493-496
    • /
    • 2005
  • For home healthcare, the unconstrained measurement of physiological signal is highly required to avoid the inconvenience of users. The recording and analysis of the fundamental parameters during sleep like respiration and heart beat provide valuable information on his/her healthcare. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The balancing tube between two air cells is used to increase the robustness against postural changes during the measurement period. The meaningful frequency range could be selected by the pneumatic filter with balancing tube. ECG (Electrocardiography) and respiration sensor (plethysmography) were measured for comparison with the signal from air mattress. To extract the heart beat information from air pressure sensor, digital signal processing technique was used. The accuracy for breathing interval and heart beat monitoring was acceptable. It shows the potentials of air mattress sensor system to be the unconstrained home sleep monitoring system.

  • PDF

도플러 레이더와 에어 매트리스를 이용한 무구속 방식의 신생아 감시 장치 설계 (Design of Unconstrained Baby Monitoring System Based on a Doppler Radar and an Air Mattress)

  • 양성수;조성필;박호동;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.177-184
    • /
    • 2014
  • Continuous monitoring of heart rates and respiratory rates for newborns or infants is very important since the abnormal breathing and heart problems can threaten the life of newborns or infants. A noncontact baby monitoring system based on a Doppler radar and an air mattress was designed. The Doppler radar was used to acquire respiratory signals and the air mattress was employed to obtain heart rates. The performance of the designed system was evaluated using a commercialized infant simulator ($Simbaby^{TM}$) and a respiration belt transducer was used to measure respiration rates as a reference. Results for respiratory rates revealed that the correlation coefficients between I-and Q-channel and the respiration belt were 0.84 and 0.91 and the mean ${\pm}$ standard deviations of errors between them were $1.66{\pm}1.92$ (bpm) and $0.88{\pm}1.65$ (bpm). Heart rates showed that the correlation coefficient between air mattress and set value of the simulator was 0.73 and the mean ${\pm}$ standard deviation of errors between them was $1.09{\pm}3.45$ (bpm). These results indicate that the designed system holds the potential as an effective monitoring tool for continuous monitoring heart rates and respiratory rates of newborns or infants.