• Title/Summary/Keyword: Matrix uncertainty

Search Result 262, Processing Time 0.028 seconds

Robust pole assignment inside a disk of uncertain linear system (불확정성 선형시스템의 원판내 강인 극점배치)

  • Park, Sang-Min;Kim, Jin-Hoon;Ryu, Jeong-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.431-433
    • /
    • 1997
  • In this paper, we consider the robust pole assignment inside the circular region for linear systems with time-varing uncertainty. The considered uncertainties are the norm bounded uncertainty and the matrix polytopes type uncertainty. Since the considered uncertainties are time-varying, it should remind that the closed loop system be time-varing system. Therefore, we should consider not only the pole assignment but also the stability. We present new conditions that guarantee the robust pole assignment and the robust stability. Finally, we show the usefulness of our results by an example.

  • PDF

Nozzle Swing Angle Measurement Involving Weighted Uncertainty of Feature Points Based on Rotation Parameters

  • Liang Wei;Ju Huo;Chen Cai
    • Current Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.300-306
    • /
    • 2024
  • To solve the nozzle swing angle non-contact measurement problem, we present a nozzle pose estimation algorithm involving weighted measurement uncertainty based on rotation parameters. Firstly, the instantaneous axis of the rocket nozzle is constructed and used to model the pivot point and the nozzle coordinate system. Then, the rotation matrix and translation vector are parameterized by Cayley-Gibbs-Rodriguez parameters, and the novel object space collinearity error equation involving weighted measurement uncertainty of feature points is constructed. The nozzle pose is obtained at this step by the Gröbner basis method. Finally, the swing angle is calculated based on the conversion relationship between the nozzle static coordinate system and the nozzle dynamic coordinate system. Experimental results prove the high accuracy and robustness of the proposed method. In the space of 1.5 m × 1.5 m × 1.5 m, the maximum angle error of nozzle swing is 0.103°.

GLOBAL ROBUST STABILITY OF TIME-DELAY SYSTEMS WITH DISCONTINUOUS ACTIVATION FUNCTIONS UNDER POLYTOPIC PARAMETER UNCERTAINTIES

  • Wang, Zengyun;Huang, Lihong;Zuo, Yi;Zhang, Lingling
    • Bulletin of the Korean Mathematical Society
    • /
    • v.47 no.1
    • /
    • pp.89-102
    • /
    • 2010
  • This paper concerns the problem of global robust stability of a time-delay discontinuous system with a positive-defined connection matrix under polytopic-type uncertainty. In order to give the stability condition, we firstly address the existence of solution and equilibrium point based on the properties of M-matrix, Lyapunov-like approach and the theories of differential equations with discontinuous right-hand side as introduced by Filippov. Second, we give the delay-independent and delay-dependent stability condition in terms of linear matrix inequalities (LMIs), and based on Lyapunov function and the properties of the convex sets. One numerical example demonstrate the validity of the proposed criteria.

Delay-Dependent Guaranteed Cost Control for Uncertain Neutral Systems with Distributed Delays

  • Li, Yongmin;Xu, Shengyuan;Zhang, Baoyong;Chu, Yuming
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.1
    • /
    • pp.15-23
    • /
    • 2008
  • This paper considers the problem of delay-dependent guaranteed cost controller design for uncertain neutral systems with distributed delays. The system under consideration is subject to norm-bounded time-varying parametric uncertainty appearing in all the matrices of the state-space model. By constructing appropriate Lyapunov functionals and using matrix inequality techniques, a state feedback controller is designed such that the resulting closed-loop system is not only robustly stable but also guarantees an adequate level of performance for all admissible uncertainties. Furthermore, a convex optimization problem is introduced to minimize a specified cost bound. By matrix transformation techniques, the corresponding optimal guaranteed controller can be obtained by solving a linear matrix inequality. Finally, a simulation example is presented to demonstrate the effectiveness of the proposed approach.

Uncertainty Analysis of Observation Matrix for 3D Reconstruction (3차원 복원을 위한 관측행렬의 불확실성 분석)

  • Koh, Sung-shik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.527-535
    • /
    • 2016
  • Statistical optimization algorithms have been variously developed to estimate the 3D shape and motion. However, statistical approaches are limited to analyze the sensitive effects of SfM(Shape from Motion) according to the camera's geometrical position or viewing angles and so on. This paper propose the quantitative estimation method about the uncertainties of an observation matrix by using camera imaging configuration factors predict the reconstruction ambiguities in SfM. This is a very efficient method to predict the final reconstruction performance of SfM algorithm. Moreover, the important point is that our method show how to derive the active guidelines in order to set the camera imaging configurations which can be expected to lead the reasonable reconstruction results. The experimental results verify the quantitative estimates of an observation matrix by using camera imaging configurations and confirm the effectiveness of our algorithm.

Measurement uncertainty for QC/QA applied to the chemical analysis (화학 분석 결과의 QA/QC를 위한 측정 불확도)

  • Woo, Jin-Chun;Oh, Sang-Hyub;Kim, Byoung-Moon;Bae, Hyun-Kil;Kim, Kwang-Sub;Kim, Young-Doo
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.475-482
    • /
    • 2005
  • The expression of uncertainty applied to the chemical analysis is highly recommended with increasing demands upon the systematic quality assurance and control(QA/QC) with ISO 17025. For the quantification of quality source, 7 major common sources of uncertainty, normally contributing to the quality of the chemical analysis, were selected from QA/QC literatures of chemical analysis. They were classified into repeatability, drift, uncertainty in standards, linearity of calibration, homogeneity, stability of sample, and matrix effect. And, the quantification of the sources by means of measurement uncertainty was proposed as a prerequisite steps for QA/QC. Examples applied to the quantification procedures of modelling, combination and expression of standard uncertainty for the 7 major common sources were presented as a reference guide for QA/QC in chemical analysis.

Non-stochastic interval arithmetic-based finite element analysis for structural uncertainty response estimate

  • Lee, Dongkyu;Park, Sungsoo;Shin, Soomi
    • Structural Engineering and Mechanics
    • /
    • v.29 no.5
    • /
    • pp.469-488
    • /
    • 2008
  • Finite element methods have often been used for structural analyses of various mechanical problems. When finite element analyses are utilized to resolve mechanical systems, numerical uncertainties in the initial data such as structural parameters and loading conditions may result in uncertainties in the structural responses. Therefore the initial data have to be as accurate as possible in order to obtain reliable structural analysis results. The typical finite element method may not properly represent discrete systems when using uncertain data, since all input data of material properties and applied loads are defined by nominal values. An interval finite element analysis, which uses the interval arithmetic as introduced by Moore (1966) is proposed as a non-stochastic method in this study and serves a new numerical tool for evaluating the uncertainties of the initial data in structural analyses. According to this method, the element stiffness matrix includes interval terms of the lower and upper bounds of the structural parameters, and interval change functions are devised. Numerical uncertainties in the initial data are described as a tolerance error and tree graphs of uncertain data are constructed by numerical uncertainty combinations of each parameter. The structural responses calculated by all uncertainty cases can be easily estimated so that structural safety can be included in the design. Numerical applications of truss and frame structures demonstrate the efficiency of the present method with respect to numerical analyses of structural uncertainties.

Monte Carlo burnup and its uncertainty propagation analyses for VERA depletion benchmarks by McCARD

  • Park, Ho Jin;Lee, Dong Hyuk;Jeon, Byoung Kyu;Shim, Hyung Jin
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1043-1050
    • /
    • 2018
  • For an efficient Monte Carlo (MC) burnup analysis, an accurate high-order depletion scheme to consider the nonlinear flux variation in a coarse burnup-step interval is crucial accompanied with an accurate depletion equation solver. In a Seoul National University MC code, McCARD, the high-order depletion schemes of the quadratic depletion method (QDM) and the linear extrapolation/quadratic interpolation (LEQI) method and a depletion equation solver by the Chebyshev rational approximation method (CRAM) have been newly implemented in addition to the existing constant extrapolation/backward extrapolation (CEBE) method using the matrix exponential method (MEM) solver with substeps. In this paper, the quadratic extrapolation/quadratic interpolation (QEQI) method is proposed as a new high-order depletion scheme. In order to examine the effectiveness of the newly-implemented depletion modules in McCARD, four problems in the VERA depletion benchmarks are solved by CEBE/MEM, CEBE/CRAM, LEQI/MEM, QEQI/MEM, and QDM for gadolinium isotopes. From the comparisons, it is shown that the QEQI/MEM predicts ${k_{inf}}^{\prime}s$ most accurately among the test cases. In addition, statistical uncertainty propagation analyses for a VERA pin cell problem are conducted by the sensitivity and uncertainty and the stochastic sampling methods.

Design of Stabilizing Controllers for Fuzzy Systems with Uncertainty (불확실성을 가지는 퍼지 시스템을 위한 안정화 제어기 설계)

  • 곽기호;박주영
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.11a
    • /
    • pp.183-187
    • /
    • 2000
  • 본 논문에서는 불확실성을 가지는 TS 퍼지 시스템을 안정화시킬 수 있는 제어기를 제안하고, 선형행렬부등식(Linear Matrix Inequality : LMI)을 이용한 설계 방법을 제시하였다. 그리고, 간단한 예제를 통하여 제안된 기법의 응용 가능성을 확인하여 보았다.

  • PDF

CONFIDENCE CURVES FOR A FUNCTION OF PARAMETERS IN NONLINEAR REGRESSION

  • Kahng, Myung-Wook
    • Journal of the Korean Statistical Society
    • /
    • v.32 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • We consider obtaining graphical summaries of uncertainty in estimates of parameters in nonlinear models. A nonlinear constrained optimization algorithm is developed for likelihood based confidence intervals for the functions of parameters in the model The results are applied to the problem of finding significance levels in nonlinear models.