• Title/Summary/Keyword: Matrix separation

Search Result 373, Processing Time 0.03 seconds

Removal of Impurities by Magnetic Separation from Waste Fluidized Cracking Catalyst for Its Reuse (폐FCC 촉매의 재활용 과정에서 자력 선별법에 의한 불순물 제거 연구)

  • Ban Bong-Chan;Lee Jin-Suk;Kim Dong-Su
    • Resources Recycling
    • /
    • v.12 no.1
    • /
    • pp.55-64
    • /
    • 2003
  • Presently, the reuse of waste FCC catalysts, which generated from the refining process of crack oil, after the removal of con-taminated metallic impurities have not been attempted domestically yet because the separation technology f3r the impurities from waste catalysts has not been established. As a basic study far the reusable portion from the waste FCC catalysts and treatment of metallic impurities are assured, there will be invoked an significant contribution not only in the recycling of abandoned wastes up to date but also in the treatment efficiency of wastes and extraction of economical benefits from them. The magnetic separation of impurities such as Fe, Ni, and V, from waste FCC catalyst has been attempted with or without its pre-oxidation at high temperature for the purpose of its reuse. The results showed that the separability of impurities by magnetic force was high far non-preoxidized catalysts compared with preoxidized ones, and employment of screen-type matrix showed a higher separation efficiency than ball-type matrix. The separability increased with the strength of magnetic field, and the method of ball matrix has separation efficiency of maximum 51.10%. The amount of metallic impurities was in the decreasing order of V, Ni, and Fe depending upon ICP analysis.

Analytic study on lead and cadmium in copper contained carbon materials (구리를 함유한 탄소소재의 납 및 카드뮴 분석에 관한 연구)

  • Choi, Zel-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.6
    • /
    • pp.307-313
    • /
    • 2010
  • Quantitative analytical condition for lead and cadmium in copper contained carbon materials using solvent extraction followed by inductively coupled plasma-atomic emission spectrometry was studied. Copper contained carbon samples were dissolved by nitric acid-perchloric acid digestion. Lead and cadmium were determined after separation with KCN masked copper by an dithizone-chloroform solvent extraction. Recovery efficiency of analyte elements was satisfactory, and most of matrix elements causing interference could be effectively eliminated by the separation. Lead and cadmium were quantitatively determined without influence of sample matrix, by applying it procedure to artifact sample.

Harmonic and Percussive Separation Based on NMF and Tonality Mask

  • Choi, Keunwoo;Chon, Sang Bae;Kang, Kyeongok
    • ETRI Journal
    • /
    • v.34 no.6
    • /
    • pp.958-961
    • /
    • 2012
  • In this letter, we present a new algorithm for the harmonic and percussive separation of jazz music. Using a short-time Fourier transform and nonnegative matrix factorization, the signal is decomposed into rank components. Each component is then split into harmonic and percussive parts using masks calculated based on their tonalities. Finally, the harmonic and percussive parts are separated after applying the masks and a summation. We evaluate the algorithm based on real audio examples using both objective and subjective assessments. The proposed algorithm performs well for the separation of harmonic and percussive parts of jazz excerpts.

Analysis of Broad-Range DNA Fragments with Yttrium Oxide or Ytterbium Oxide Nanoparticle/Polymer Sieving Matrix Using High-Performance Capillary Electrophoresis

  • Kwon, Hae-Myun;Kim, Yong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.2
    • /
    • pp.297-301
    • /
    • 2009
  • We have developed the yttrium oxide (YNP) or ytterbium oxide (YbNP) nanoparticle/polymer matrices for the size-dependent separation of DNA ranging from 100 bp to 9,000 bp. High separation efficiency (> $10^6$ plates/m) and the baseline resolution for various DNA standards (100 bp, 500 bp, and 1 kbp DNA ladder) were obtained in 10 min with these matrices. The effects of concentrations of both polyethylene oxide (PEO) and nanoparticles were investigated and the highest performance was obtained at 0.02% PEO with 0.02% YNP or YbNP. Similar sieving power for both YNP and YbNP matrices was observed probably due to the similar sizes of nanoparticles, resulting in the formation of comparable sieving networks for DNA separation. For the reduction of electrosmotic flow, either dynamic or permanent coating of the capillary inner wall was compared and it turned out that PEO was superior to polyvinylpyrrolidone (PVP) or polyacrylamide (PAA) for better separation efficiency.

Accurate Measurement of Isotope Amount Ratios of Lead in Bronze with Multicollector Inductively Coupled Plasma Mass Spectrometry

  • Lee, Kyoung-Seok;Kim, Jin-Il;Yim, Yong-Hyeon;Hwang, Euijin;Kim, Tae Kyu
    • Mass Spectrometry Letters
    • /
    • v.4 no.4
    • /
    • pp.87-90
    • /
    • 2013
  • Isotope amount ratios of lead in a bronze sample have been successfully determined using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS). Matrix separation conditions were tested and optimized using ion exchange chromatography with anion-exchange resin, AG1-X8, and sequential elution of the 0.5 M HBr and 7 M $HNO_3$ to separate lead from very high contents of copper and tin in bronze matrix. Mercury was also removed efficiently in the optimized separation condition. The instrumental isotope fractionation of lead in the MC-ICP-MS measurement was corrected by the external standard sample bracketing method using an external standard, NIST SRM 981 lead common isotope ratio standard followed by correction of procedure blank to obtain reliable isotope ratios of lead. The isotope ratios, $^{206}Pb/^{204}Pb$, $^{207}Pb/^{204}Pb$, $^{208}Pb/^{204}Pb$, and $^{208}Pb/^{206}Pb$, of lead were determined as $18.0802{\pm}0.0114$, $15.5799{\pm}0.0099$, $38.0853{\pm}0.0241$, and $2.1065{\pm}0.0004$, respectively, and the determined isotope ratios showed good agreement with the reference values of an international comparison for the same sample within the stated uncertainties

PVA/H-β zeolite mixed matrix membranes for pervaporation dehydration of isopropanol-water mixtures

  • Huang, Zhen;Ru, Xiao-Fei;Guo, Yu-Hua;Zhu, Ya-Tong;Teng, Li-Jun
    • Membrane and Water Treatment
    • /
    • v.10 no.2
    • /
    • pp.165-178
    • /
    • 2019
  • Mixed matrix membranes (MMMs) of poly (vinyl alcohol) (PVA) containing certain amounts of H-${\beta}$ zeolite for pervaporation were manufactured by using a solution casting protocol. These zeolite-embedded membranes were then characterized with scanning electron microscope (SEM), X-ray diffraction (XRD) and swelling tests. The membrane separation performance has been examined by means of isopropanol (IPA) dewatering from its highly concentrated aqueous solutions via response surface methodology (RSM). The results have demonstrated that the influences of feed IPA composition (85-95 wt.%), feed temperature ($50-70^{\circ}C$), zeolite loading (15-25 wt.%) and their interactive influences are all statistically significant on both pervaporation flux ($398-1228g/m^2{\cdot}h$) and water/isopropanol separation factor (617-2001). The quadratic models based on the RSM analysis have performed excellently to correlate experimental data with very high determination coefficients and very low relative standard deviations. The optimal pervaporation predictions given by using the RSM models demonstrate a total flux of $953g/m^2{\cdot}h$ and separation factor of 1458, and are excellently verified by experimental results. As reflected by these results, PVA MMMs embedded with hydrophilic $H-{\beta}$ zeolite entities have performed considerably better than its pure counterpart and indicated great potential for isopropanol dehydration applications.

Recent Advances on Ionic Liquid based Mixed Matrix Membrane for CO2 Separation (CO2 분리를 위한 이온성 액체 기반 혼합 매트릭스 멤브레인의 최근 발전)

  • Wang, Chaerim;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.31 no.1
    • /
    • pp.1-15
    • /
    • 2021
  • The membrane-based CO2 capture is a fast-growing branch in gas separating field. Ionic liquid assisted mixed matrix membrane (MMM), which consists of organic fillers with dispersed ionic liquid, shows high potentiality as a candidate for CO2 separation medium. In MMM, various kinds of ionic liquid and inorganic filler are incorporated into polymer to enhance gas separating performance. Especially, the strong interaction between ionic liquid and organic filler gives huge influence on enhancing the separating performance by increasing affinity, selectivity and adsorption of CO2 into the framework. Also the mechanical properties of metal organic framework are positively tuned by input of ionic liquid to improve CO2 permeability and selectivity. In this review, study of various combinations of ionic liquid and metal organic framework (MOF) in the polymeric membrane for carbon dioxide separation is discussed.

Construction of Probability Identification Matrix and Selective Medium for Acidophilic Actinomycetes Using Numerical Classification Data

  • Seong, Chi-Nam;Park, Seok-Kyu;Michael Goodfellow;Kim, Seung-Bum;Hah, Yung-Chil
    • Journal of Microbiology
    • /
    • v.33 no.2
    • /
    • pp.95-102
    • /
    • 1995
  • A probability identification matrix of acidophilic Streptomyces was constructed. The phenetic data of the strains were derived from numerical classification described by Seong et al. The minimum number of diagnostic characters was determined using computer programs for calculation of different separation indices. The resulting matrix consisted of 25 clusters versus 53 characters. Theoretical evaluation of this matrix was achieved by estimating the chuster overlap and the identification scores for the Hypothetical Median Organisms (HMO) and for the representatives of each cluster. Cluster overlap was found to be relatively small. Identification scores for the HMO and the randomly selected representatives of each cluster were satisfactory. The matrix was assessed practically by applying the matrix to the identification of unknown isolates. Of the unknown isolates, 71.9% were clearly identified to one of eight clusters. The numerical classification data was also used to design a selective isolation medium for antibiotic-producing organisms. Four chemical substances including 2 antibiotics were determined by the DLACHAR program as diagnostic for the isolation of target organisms which have antimicrobial activity against Micrococcus luteus. It was possible to detect the increased rate of selective isolation on the synthesized medium. Theresults show that the numerical phenetic data can be applied to a variety of purposes, such as construction of identification matrix and selective isolation medium for acidophilic antinomycetes.

  • PDF

On the Error Bound of the Approximate Solution of a Nonclassically Damped Linear System under Periodic Excitations

  • Hwang, Jai-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.4E
    • /
    • pp.45-52
    • /
    • 1996
  • One common procedure in the approximate solution of a nonclassically damped linear system is to neglect the off-diagonal elements of the normalized damping matrix. A tight error bound, which can be computed with relative ease, is given for this method of solution. The role that modal coupling plays in the control of error is clarified. If the normalized damping matrix is strongly diagonally dominant, it is shown that adequate frequency separation is not necessary to ensure small errors.

  • PDF